BACKGROUND Gustilo III fractures have a high incidence and are difficult to treat.Patients often experience difficulty in wound healing.Negative pressure drainage technology can help shorten wound healing time and has...BACKGROUND Gustilo III fractures have a high incidence and are difficult to treat.Patients often experience difficulty in wound healing.Negative pressure drainage technology can help shorten wound healing time and has positive value in improving patient prognosis.AIM To explore the clinical value of the negative pressure sealing drainage technique in wound healing of Gustilo IIIB and IIIC open fractures.METHODS Eighty patients with Gustilo IIIB and IIIC open fractures with skin and soft tissue injuries who were treated in the Second People’s Hospital of Dalian from March 2019 to December 2021 were selected as the research subjects.They were divided into a study group(n=40,healed with negative pressure closed drainage)and a control group(n=40,healed with conventional dressing changes)according to the variation in the healing they received.The efficacy of the clinical interventions,the variations in the regression indicators(time to wound healing,time to fracture healing,time to hospitalization),and the conversion and healing of bacterial wounds were compared 1-3 mo after the intervention.RESULTS The total effective rate of patients among the study group was 95.00%(38/40),which was notably higher than 75.00%(30/40)among the control group(P<0.05).The wound healing time,fracture healing time,and hospital stay of the patients in the study group was shorter than the control group(P<0.05).After the intervention,the negative bacterial culture at the wound site rate and wound healing rate of the patients among the study group increased compared to the control group(P<0.05).CONCLUSION Negative pressure sealing and drainage technology has a good therapeutic effect on patients with Gustilo IIIB and IIIC open fracture wounds with skin and soft tissue injury.It can notably enhance the wound healing rate and the negative rate of bacteria on the wound surface and help to speed up the recovery process of patients.展开更多
BACKGROUND Necrotizing fasciitis(NF)of the upper extremities is a severe surgical pathology,and the incidence of this disease has been steadily increasing in recent decades.Surgical treatment is accompanied by the for...BACKGROUND Necrotizing fasciitis(NF)of the upper extremities is a severe surgical pathology,and the incidence of this disease has been steadily increasing in recent decades.Surgical treatment is accompanied by the formation of extensive wounds,which can be treated with significant difficulties.In recent years,negative pressure wound therapy(NPWT)has proven to be highly effective.It is also promising for the treatment of NF.AIM To explore the effectiveness of NPWT in the treatment of NF of the upper extremities.METHODS The results of the treatment of 36 patients with NF of the upper extremities in two groups(NPWT group and control group;2022−2023)were retrospectively analyzed.In the NPWT group,the NPWT method(120 mmHg;constant mode)was used after surgical treatment.The number of vacuum-assisted dressings in patients ranged from 1 to 3,depending on the dynamics of the wound process.The duration of fixation of one bandage was up to 2−3 d.In the control group,conventional methods of local wound treatment were used.The following indicators were analyzed:The treatment delay,the prevalence of inflammation,the microbial landscape,the number of debridements,the duration of wound preparation for surgical closure,and the nature of skin plastic surgery.RESULTS Most patients experienced a significant treatment delay[4 d,interquartile range(IQR):2–7 d],which led to the spread of the pathological process to the forearm and shoulder.The most common pathogens were Staphylococcus aureus(14;38.9%)and Streptococcus pyogenes(22;61.1%).The average number of debridements per patient was 5(IQR:3–7),with no difference between groups.The average time to prepare wounds for surgical closure was 11±4 d in the NPWT group and 29±10 d(P=0.00001)in the control group.In the NPWT group,the wounds were more often closed with local tissues(15;83.3%),and in the control group,split-thickness skin grafts were more often used(4;50%).CONCLUSION The predominant isolation of Staphylococcus aureus and/or Streptococcus pyogenes from the lesions allowed us to classify these patients as NF type II.Multiple debridement procedures have become a feature of this disease treatment.The use of NPWT has significantly reduced the time required to prepare wounds for surgical closure.Early closure of wounds allows for more frequent use of local tissue repair,which ensures better results.NPWT is a highly effective way to prepare wounds for early surgical closure in patients with upper extremity NF.展开更多
BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complic...BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complication after ileostomy closure.AIM To evaluate the efficacy and safety of the micro-power negative pressure wound technique(MPNPWT)in preventing incisional SSI.METHODS This was a prospective,randomized controlled clinical trial conducted at a single center.A total of 101 consecutive patients who underwent ileostomy closure after rectal cancer surgery with a prophylactic ileostomy were enrolled from January 2019 to December 2021.Patients were randomly allocated into an MPNPWT group and a control group.The MPNPWT group underwent intermittent suturing of the surgical incision with 2-0 Prolene and was covered with a micro-power negative pressure dressing.The surgical outcomes were compared between the MPNPWT(n=50)and control(n=51)groups.Risk factors for incisional SSI were identified using logistic regression.RESULTS There were no differences in baseline characteristics between the MPNPWT(n=50)and control groups(n=51).The incisional SSI rate was significantly higher in the control group than in the MPNPWT group(15.7%vs 2.0%,P=0.031).However,MPNPWT did not affect other surgical outcomes,including intra-abdominal complications,operative time,and blood loss.Postoperative hospital stay length and hospitalization costs did not differ significantly between the two groups(P=0.069 and 0.843,respectively).None of the patients experienced adverse effects of MPNPWT,including skin allergy,dermatitis,and pain.MPNPWT also helped heal the infected incision.Our study indicated that MPNPWT was an independent protective factor[odds ratio(OR)=0.005,P=0.025)]and diabetes was a risk factor(OR=26.575,P=0.029)for incisional SSI.CONCLUSION MPNPWT is an effective and safe way to prevent incisional SSI after loop ileostomy closure.展开更多
This report describes a novel technique for improving depressed scars using negative pressure suction-assisted autologous fat grafting.A 35-year-old woman presented with a 20-year history of bilateral central buttock ...This report describes a novel technique for improving depressed scars using negative pressure suction-assisted autologous fat grafting.A 35-year-old woman presented with a 20-year history of bilateral central buttock con-cavities,causing aesthetic concerns.To maximize fat graft survival and enhance tissue volume,we implemented intermittent negative pressure suction on the recipient area for one month preoperatively.The patient expressed satisfaction with the cosmetic outcome,and a three-month follow-up confirmed a significantly improved fat graft survival rate.This minimally invasive,cost-effective,and easily reproducible technique offers a promising clinical strategy for treating depressed scars.展开更多
Objective: This study aims to compare the effects of different drainage tube diameters (22F vs. 26F) combined with negative pressure suction on patients after valve replacement surgery, including postoperative indicat...Objective: This study aims to compare the effects of different drainage tube diameters (22F vs. 26F) combined with negative pressure suction on patients after valve replacement surgery, including postoperative indicators and complications. Methods: A total of 104 patients undergoing valve replacement surgery were included and divided into a 22F group (45 patients) and a 26F group (59 patients). The basic characteristics, postoperative ICU stay duration, drainage duration, postoperative complications, and pain scores were compared between the two groups. All data were analyzed using SPSS statistical software, with p Results: There were no significant differences between the two groups in terms of age, sex, and underlying diseases. The ICU stay duration and drainage duration showed no significant differences (p > 0.05). The total drainage volume in the 22F group was significantly lower than that in the 26F group (225 vs. 380 ml, p = 0.035), and the pain scores on the third postoperative day were also significantly lower in the 22F group (p Conclusion: Compared to the 26F group, patients in the 22F group exhibited less postoperative drainage volume and lower pain scores, suggesting that the 22F drainage tube may have better clinical outcomes after valve replacement surgery.展开更多
The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonline...The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mecha- nisms employing the error and change in error of the controlled variable as input parameters, the current cham- ber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the pro- posed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consis- tent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.展开更多
Unloading induces negative excess porewater pressure in soil mass around a foundation pit during excavation. In this work, the dissipation rule of negative excess porewater pressure after excavation was studied. Analy...Unloading induces negative excess porewater pressure in soil mass around a foundation pit during excavation. In this work, the dissipation rule of negative excess porewater pressure after excavation was studied. Analytical formulas for calculating the negative excess porewater pressures and the effective stresses were derived based on one-dimensional consolidation theory and Terzaghi’s effective stress principle. The influence of the dissipation of negative excess porewater pressure on earth pressure inside and outside a foundation pit and the stability of the retaining structure were analyzed through a numerical example. It was indicated that the dissipation of negative excess porewater pressure is harmful to the stability of the retaining structure and that rapid construction can make full use of the negative porewater pressure.展开更多
Under the optimal condition of copper ions adsorption on yeast,we found some different effects among static adsorption, shaking adsorption and negative pressure cavitation adsorption, and the methods of yeast with dif...Under the optimal condition of copper ions adsorption on yeast,we found some different effects among static adsorption, shaking adsorption and negative pressure cavitation adsorption, and the methods of yeast with different pretreatments also affect adsorption of copper ions. At the same time, the change of intercellular pH before and after adsorption of copper with BCECF was studied. The copper distribution was located by using PhenGreen (dipotassium salt and diacetate), and the surface of yeast was observed by an atomic force microscope. The results showed that negative pressure cavitation can improve bioadsorption capacity of copper ions on yeast. However, the yeasts' pretreatment has a higher effect on bioadsorption. It indicates that heavy metal bioadsorption on yeast has much relation with its cellular molecule basis. With the adsorping, the intercellular pH of yeast increased gradually and changed from acidity to alkalescence. These results may suggest that negative pressure cavitation can compel heavy metals to transfer from the cell surface into inside cell and make the surface of yeast coarse.展开更多
Effects of continuous negative pressure water supply on water consumption, growth and development, as well as physiological mechanism and quality of Capsicum annuum L. were investigated in this paper. Meanwhile, the o...Effects of continuous negative pressure water supply on water consumption, growth and development, as well as physiological mechanism and quality of Capsicum annuum L. were investigated in this paper. Meanwhile, the optimal negative pressure water supply conditions for growth of C. annuum L. were screened out to achieve the goals of water conservation, high yield and high quality, thus providing theoretical foundation for its field production. The pot experiment within the greenhouse was utilized; the continuous negative pressure water supply was adopted; the four treatments, artificial watering(CK), –5 k Pa(T1), –10 k Pa(T2), and –15 k Pa(T3) were set; and the daily water consumption, yield, as well as the biomass, nitrate reductase, root activity, vitamin C, capsaicin, and nutrient uptakes of nitrogen(N), phosphorus(P) and potassium(K) during various stages of its growth were determined. Compared with CK, when the water supply pressure was controlled at –5 to –15 k Pa in the experiment, the total water consumption of C. annuum L. reduced by 53.42 to 67.75%, the total water consumption intensity reduced by 54.29 to 67.14%, and the water use efficiency increased by 12.66 to 124.67%. The N accumulation in a single strain of C. annuum L. from the color turning stage to the red ripe stage increased by 15.99 to 100.55%, respectively, compared with that of CK; the P accumulation increased by 20.47 to 154.00% relative to that of CK, and the K accumulation increased by 64.92 to 144.9% compared with that of CK. Compared with CK, C. annuum L. yield was remarkably improved by 13.79% at T1, and contents of vitamin C, capsaicin as well as carotenoids at all growth stages were enhanced by 13.42–147.01%, 11.54–71.01%, and 41.1–568.06%, respectively. Nitrate reductase activity, root activity and chlorophyll(a+b) were markedly increased by 335.78–500%, 79.6–140.68% and 114.95–676.19%, respectively, from immature stage to full ripe stage. Adopting the continuous negative pressure water supply for C. annuum L. has a significant water-saving effect, and the water supply pressure being stable at –5 k Pa contributes to its growth and development, improves yield, enhances root activity, promotes nutrient uptake, and improves its quality, thus achieving the effects of water conservation, high yield, high quality and high efficiency.展开更多
Presented a new coal dust control program that was airtight negative pressure dust-control technology at the transpersite,combining with analysis with the movement of air currents and numerical simulation of gas-solid...Presented a new coal dust control program that was airtight negative pressure dust-control technology at the transpersite,combining with analysis with the movement of air currents and numerical simulation of gas-solid flow at the transpersite,and proved the mechanism of precipitation and proliferation for coal dust-controlt in theory.The technol- ogy has made good economic results at the Heidaigou Clean Plant,not only dust concen- tration control within 10 mg/m^3 to the work site,but also substantial energy savings and cost savings.展开更多
The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass an...The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass and particle size.The pressure fluctuation signals are analyzed by the time and the frequency domain methods.A method for absolutely characterizing the degree of the energy concentration at the main frequency is proposed,where the calculation is to divide the original power spectrum by the average signal power.A phenomenon where the gas velocity curve temporarily stops growing is observed when the material mass is light,and the particle size is small.The standard deviation and kurtosis both rapidly change at the minimum fluidization velocity and thus can be used to determine the flow regime,and the variation rule of the kurtosis is independent of both the material mass and particle size.In the initial fluidization stage,the dominant pressure signal comes from the material movement;with the increase in the gas velocity,the power of a 2.5 Hz signal continues to increase.A method of dividing the main frequency by the average cycle frequency can conveniently determine the fluidized state,and a novel concept called stable fluidized zone proposed in this paper can be obtained.Controlling the gas velocity within the stable fluidized zone ensures that the fluidized bed consistently remains in a stable fluidized state.展开更多
The relationship between the cavitation and acoustic peak negative pressure in the high-intensity focused ultrasound (HIFU) field is analyzed in water and tissue phantom. The peak negative pressure at the focus is d...The relationship between the cavitation and acoustic peak negative pressure in the high-intensity focused ultrasound (HIFU) field is analyzed in water and tissue phantom. The peak negative pressure at the focus is determined by a hybrid approach combining the measurement with the simulation. The spheroidal beam equation is utilized to describe the nonlinear acoustic propagation. The waveform at the focus is measured by a fiber optic probe hydrophone in water. The relationship between the source pressure amplitude and the excitation voltage is determined by fitting the measured ratio of the second harmonic to the fundamental component at the focus, based on the model simulation. Then the focal negative pressure is calculated for arbitrary voltage excita- tion in water and tissue phantom. A portable B-mode ultrasound scanner is applied to monitor HIFU-indueed cavitation in real time, and a passive cavitation detection (PCD) system is used to acquire the bubble scattering signals in the HIFU focal volume for the cavitation quantification. The results show that: (1) unstable cavitation starts to appear in degassed water when the peak negative pressure of HIFU signals reaches 13.5 MPa; and (2) the cavitation activity can be detected in tissue phantom by B-mode images and in the PCD system with HIFU peak negative pressures of 9.0 MPa and 7.8 MPa, respectively, which suggests that real-time B-mode images could be used to monitor the cavitation activity in two dimensions, while PCD systems are more sensitive to detect scattering and emission signals from cavitation bubbles.展开更多
BACKGROUND Thermal injuries on free transferred or replanted tissues resulting from loss of sensibility are an infrequent occurrence.They require immediate and appropriate management before they progress to an irrever...BACKGROUND Thermal injuries on free transferred or replanted tissues resulting from loss of sensibility are an infrequent occurrence.They require immediate and appropriate management before they progress to an irreversible condition.Although negative pressure wound therapy(NPWT)can prevent wound progression by increasing microcirculation,the inappropriate application of NPWT on complicationthreatened transferred and replanted tissues can induce an adverse effect.CASE SUMMARY A 48-year-old woman who underwent immediate breast reconstruction with a deep inferior epigastric artery perforator free flap.While applying a heating pad directly to the flap site,she sustained a deep second to third-degree contact burn over 30%of the transferred flap on postoperative 7 d.As the necrotic changes had progressed,we applied an NPWT dressing over the burned area after en-bloc debridement of the transferred tissues on postoperative 21 d.After 4 d of NPWT application,the exposed fatty tissues of the flap changed to dry and browncolored necrotic tissues.Upon further debridement,we noted that the wound gradually reached total necrosis with a collapsed vascular pedicle of deep inferior epigastric artery.CONCLUSION Although NPWT has been shown to be successful for treating various wound types,the significant risk of NPWT application in short-lasting reconstructed flap wounds after thermal injury should be reminded.展开更多
A series of experiments on a solid feed system was performed to investigate the effect of negative pressure gradient on the gas-solid flow pattern and hydrodynamic characteristics.Based on the non-fluidized gas-solid ...A series of experiments on a solid feed system was performed to investigate the effect of negative pressure gradient on the gas-solid flow pattern and hydrodynamic characteristics.Based on the non-fluidized gas-solid two phase flow and particulate mechanics in the standpipe,a method for predicting the pressure of the air passing through the recycle chamber and the pressure drop through the loop seal slit in these systems is also presented.The predicted pressure profile along the negative pressure gradient from the proposed model exhibits a good agreement with the experimental data.The experimental data show that the gas flow in the standpipe is always upward in the negative pressure gradients,while the direction ofthe superficial gas velocity through the recycle chamber of the loop seal does not affect the pressure drop in standpipe.It increases with an increasing negative pressure gradient.展开更多
Cover-bearing-type bucket foundation for offshore wind turbines has been paid more and more attention due to its low cost and great bearing capacity. In order to ensure the cover-bearing mode, the muddy soil inside th...Cover-bearing-type bucket foundation for offshore wind turbines has been paid more and more attention due to its low cost and great bearing capacity. In order to ensure the cover-bearing mode, the muddy soil inside the bucket foundation should be reinforced by some soil consolidation methods, such as negative pressure and electro-osmosis. Firstly, tests were conducted to obtain the reasonable current density. Meanwhile, to improve the electro-osmotic speed and effectiveness, other factors such as intermittent power and layout of electrode, were also studied in the tests. Then, the soil reinforcing tests by negative pressure combined with electro-osmosis were performed for the muddy soil consolidation inside the bucket foundation. The results showed that soil reinforcement by negative pressure was quicker and more obvious during the early phase, and electro-osmotic method can affect more range of soil by rational arrangement of electrodes. Compared with negative pressure, the electro-osmotic method was a continuous and relatively slow process of reinforcement, which was complementary to the negative pressure method. The voltage value of electro-osmosis had little effect on the muddy soil reinforcement inside the bucket foundation, and 1.5 A was chosen as the most reasonable current value for scale model testing in the electro-osmotic method.展开更多
Background: Septic open abdomens occur in trauma, burn and surgery. Currently, multiple concentrations of hypochlorous acid solutions have effectively decreased the microbiotic burden in wounds. We hypothesized that V...Background: Septic open abdomens occur in trauma, burn and surgery. Currently, multiple concentrations of hypochlorous acid solutions have effectively decreased the microbiotic burden in wounds. We hypothesized that Vashe?, a neutral hypochlorous acid solution (V-HOCL), would be safe as an intraperitoneal irrigation or washout disinfectant for septic open abdomens utilizing negative pressure wound therapy. Methods: This is a retrospective observational review of patients who required delayed abdominal closures after exploratory laparotomies. Group A (n = 8) had cyclical V-HOCL irrigation to their open abdomens combining AbtheraTM and V.A.C. Dressing System for negative pressure wound therapy with irrigation (NPWT-i) and Group B (n = 9) had intra-abdominal V-HOCL washouts. Results: Fifty percent of both groups had either septic or hemorrhagic shock on admission. Compared to Group B, Group A patients were older (median 50 vs 37 years), and had a median hospitalization of 28 vs 8 days, 4 times as many operations, more acute renal failure and co-morbidities. No statistically significant differences were detected be-tween the two treatment methods with the V-HOCL delivery and removal. Conclusion: There were no episodes of electrolyte imbalance, hypotension, hypertension, anaphylaxis, hemorrhage, visceral injury or systemic toxicity. V-HOCL with/without NPWT-i irrigation was a safe modality and tolerated well in this study.展开更多
In this paper we would like to give a brief review about the extensibility of the liquid-liquid locus into the negativepressure region. Negative pressure states are hardly explored; most researchers believe that the p...In this paper we would like to give a brief review about the extensibility of the liquid-liquid locus into the negativepressure region. Negative pressure states are hardly explored; most researchers believe that the pressure scale ends at p = 0.We would like to show that this is not true, the p = 0 point is not a special point for liquids, it can be 'easily' crossed. We aregoing to give a few example, where the extension of liquid-liquid locus for polymer blends and solutions below p = 0 givesus some interesting results, like the merging of UCST and LCST branches in weakly interacting polymer solutions or thereason why most UCST blends exhibit pressure induced immiscibility. Also, we will see what happens with the immiscibilityisland of aqueous polymer solutions when -- reaching the critical molar mass -- it 'disappears'.展开更多
Mechanical properties, such as the deformation and stress distributions for venous walls under the combined load of transmural pressure and axial stretch, are examined within the framework of nonlinear elasticity with...Mechanical properties, such as the deformation and stress distributions for venous walls under the combined load of transmural pressure and axial stretch, are examined within the framework of nonlinear elasticity with one kind of hyper-elastic strain energy functions. The negative pressure instability problem of the venous wall is explained through energy comparison. First, the deformation equation of the venous wall under the combined loads is obtained with a thin-walled circular cylindrical tube. The deformation curves and the stress distributions for the venous wall are given under the normal transmural pressure, and the regulations are discussed. Then, the deformation curves of the venous wall under the negative transmural pressure or the internal pressure less than the external pressure are given. Finally, the negative pressure instability problem is discussed through energy comparison.展开更多
BACKGROUND Postoperative unobstructed drainage is an important measure for avoiding hematoma formation and preventing complications from anterior cervical surgery.AIM To discuss the characteristics and key points of c...BACKGROUND Postoperative unobstructed drainage is an important measure for avoiding hematoma formation and preventing complications from anterior cervical surgery.AIM To discuss the characteristics and key points of clinical management of two types of commonly used negative pressure drainage systems in clinical settings.METHODS Two types of commonly used silica gel negative pressure drainage balls and a type of gastrointestinal decompression apparatus were fully emptied and then injected with different amounts of water and air.Following this,the negative pressure values of the three devices were measured.Meanwhile,we undertook a retrospective analysis of the clinical data of 1328 patients who had been treated with different negative pressure drainage apparatuses during their anterior cervical surgery in our department between January 2007 and January 2018.RESULTS As the amount of injected air or water increased,the negative pressure of the silica gel negative pressure drainage ball decreased rapidly,dropping to zero when 150 mL of water or air was injected.In contrast,the negative pressure of gastrointestinal decompression apparatus decreased slowly,maintaining an ideal value even when 300 mL of water or air was injected.And statistical analysis demonstrated that patients who had been treated with the gastrointestinal decompression apparatus were less likely to develop severe complications than those who had been treated with the silica gel negative pressure drainage ball(P<0.05).CONCLUSION This study showed that the gastrointestinal decompression apparatus has the advantages of large suction capacity,long duration of continuous negative pressure,and good drainage effect,all of which are the favorable factors for the use of this apparatus for negative pressure drainage in anterior cervical surgery.展开更多
基金the Review Committee of Fuzhou Medical College of Nanchang University(Approval No.4445644).
文摘BACKGROUND Gustilo III fractures have a high incidence and are difficult to treat.Patients often experience difficulty in wound healing.Negative pressure drainage technology can help shorten wound healing time and has positive value in improving patient prognosis.AIM To explore the clinical value of the negative pressure sealing drainage technique in wound healing of Gustilo IIIB and IIIC open fractures.METHODS Eighty patients with Gustilo IIIB and IIIC open fractures with skin and soft tissue injuries who were treated in the Second People’s Hospital of Dalian from March 2019 to December 2021 were selected as the research subjects.They were divided into a study group(n=40,healed with negative pressure closed drainage)and a control group(n=40,healed with conventional dressing changes)according to the variation in the healing they received.The efficacy of the clinical interventions,the variations in the regression indicators(time to wound healing,time to fracture healing,time to hospitalization),and the conversion and healing of bacterial wounds were compared 1-3 mo after the intervention.RESULTS The total effective rate of patients among the study group was 95.00%(38/40),which was notably higher than 75.00%(30/40)among the control group(P<0.05).The wound healing time,fracture healing time,and hospital stay of the patients in the study group was shorter than the control group(P<0.05).After the intervention,the negative bacterial culture at the wound site rate and wound healing rate of the patients among the study group increased compared to the control group(P<0.05).CONCLUSION Negative pressure sealing and drainage technology has a good therapeutic effect on patients with Gustilo IIIB and IIIC open fracture wounds with skin and soft tissue injury.It can notably enhance the wound healing rate and the negative rate of bacteria on the wound surface and help to speed up the recovery process of patients.
文摘BACKGROUND Necrotizing fasciitis(NF)of the upper extremities is a severe surgical pathology,and the incidence of this disease has been steadily increasing in recent decades.Surgical treatment is accompanied by the formation of extensive wounds,which can be treated with significant difficulties.In recent years,negative pressure wound therapy(NPWT)has proven to be highly effective.It is also promising for the treatment of NF.AIM To explore the effectiveness of NPWT in the treatment of NF of the upper extremities.METHODS The results of the treatment of 36 patients with NF of the upper extremities in two groups(NPWT group and control group;2022−2023)were retrospectively analyzed.In the NPWT group,the NPWT method(120 mmHg;constant mode)was used after surgical treatment.The number of vacuum-assisted dressings in patients ranged from 1 to 3,depending on the dynamics of the wound process.The duration of fixation of one bandage was up to 2−3 d.In the control group,conventional methods of local wound treatment were used.The following indicators were analyzed:The treatment delay,the prevalence of inflammation,the microbial landscape,the number of debridements,the duration of wound preparation for surgical closure,and the nature of skin plastic surgery.RESULTS Most patients experienced a significant treatment delay[4 d,interquartile range(IQR):2–7 d],which led to the spread of the pathological process to the forearm and shoulder.The most common pathogens were Staphylococcus aureus(14;38.9%)and Streptococcus pyogenes(22;61.1%).The average number of debridements per patient was 5(IQR:3–7),with no difference between groups.The average time to prepare wounds for surgical closure was 11±4 d in the NPWT group and 29±10 d(P=0.00001)in the control group.In the NPWT group,the wounds were more often closed with local tissues(15;83.3%),and in the control group,split-thickness skin grafts were more often used(4;50%).CONCLUSION The predominant isolation of Staphylococcus aureus and/or Streptococcus pyogenes from the lesions allowed us to classify these patients as NF type II.Multiple debridement procedures have become a feature of this disease treatment.The use of NPWT has significantly reduced the time required to prepare wounds for surgical closure.Early closure of wounds allows for more frequent use of local tissue repair,which ensures better results.NPWT is a highly effective way to prepare wounds for early surgical closure in patients with upper extremity NF.
基金Supported by the Zhejiang Provincial Natural Science Foundation of China,No.LQ20H260002.
文摘BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complication after ileostomy closure.AIM To evaluate the efficacy and safety of the micro-power negative pressure wound technique(MPNPWT)in preventing incisional SSI.METHODS This was a prospective,randomized controlled clinical trial conducted at a single center.A total of 101 consecutive patients who underwent ileostomy closure after rectal cancer surgery with a prophylactic ileostomy were enrolled from January 2019 to December 2021.Patients were randomly allocated into an MPNPWT group and a control group.The MPNPWT group underwent intermittent suturing of the surgical incision with 2-0 Prolene and was covered with a micro-power negative pressure dressing.The surgical outcomes were compared between the MPNPWT(n=50)and control(n=51)groups.Risk factors for incisional SSI were identified using logistic regression.RESULTS There were no differences in baseline characteristics between the MPNPWT(n=50)and control groups(n=51).The incisional SSI rate was significantly higher in the control group than in the MPNPWT group(15.7%vs 2.0%,P=0.031).However,MPNPWT did not affect other surgical outcomes,including intra-abdominal complications,operative time,and blood loss.Postoperative hospital stay length and hospitalization costs did not differ significantly between the two groups(P=0.069 and 0.843,respectively).None of the patients experienced adverse effects of MPNPWT,including skin allergy,dermatitis,and pain.MPNPWT also helped heal the infected incision.Our study indicated that MPNPWT was an independent protective factor[odds ratio(OR)=0.005,P=0.025)]and diabetes was a risk factor(OR=26.575,P=0.029)for incisional SSI.CONCLUSION MPNPWT is an effective and safe way to prevent incisional SSI after loop ileostomy closure.
基金supported by the Clinical Research Program of Shanghai Ninth People’s Hospital,Shanghai Jiao Tong University School of Medicine(grant no.JYLJ202103)Two-Hundred Talent(grant no.20191916)Shanghai Clinical Research Center of Plastic and Reconstructive Surgery supported by Science and Technology Commission of Shanghai Municipality(grant no.22MC1940300)。
文摘This report describes a novel technique for improving depressed scars using negative pressure suction-assisted autologous fat grafting.A 35-year-old woman presented with a 20-year history of bilateral central buttock con-cavities,causing aesthetic concerns.To maximize fat graft survival and enhance tissue volume,we implemented intermittent negative pressure suction on the recipient area for one month preoperatively.The patient expressed satisfaction with the cosmetic outcome,and a three-month follow-up confirmed a significantly improved fat graft survival rate.This minimally invasive,cost-effective,and easily reproducible technique offers a promising clinical strategy for treating depressed scars.
文摘Objective: This study aims to compare the effects of different drainage tube diameters (22F vs. 26F) combined with negative pressure suction on patients after valve replacement surgery, including postoperative indicators and complications. Methods: A total of 104 patients undergoing valve replacement surgery were included and divided into a 22F group (45 patients) and a 26F group (59 patients). The basic characteristics, postoperative ICU stay duration, drainage duration, postoperative complications, and pain scores were compared between the two groups. All data were analyzed using SPSS statistical software, with p Results: There were no significant differences between the two groups in terms of age, sex, and underlying diseases. The ICU stay duration and drainage duration showed no significant differences (p > 0.05). The total drainage volume in the 22F group was significantly lower than that in the 26F group (225 vs. 380 ml, p = 0.035), and the pain scores on the third postoperative day were also significantly lower in the 22F group (p Conclusion: Compared to the 26F group, patients in the 22F group exhibited less postoperative drainage volume and lower pain scores, suggesting that the 22F drainage tube may have better clinical outcomes after valve replacement surgery.
基金Supported by National Natural Science Foundation of China(Grant No.51575199)
文摘The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mecha- nisms employing the error and change in error of the controlled variable as input parameters, the current cham- ber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the pro- posed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consis- tent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.
基金Project (No. 20030335027) supported by the National ResearchFoundation for the Doctoral Program of Higher Education of China
文摘Unloading induces negative excess porewater pressure in soil mass around a foundation pit during excavation. In this work, the dissipation rule of negative excess porewater pressure after excavation was studied. Analytical formulas for calculating the negative excess porewater pressures and the effective stresses were derived based on one-dimensional consolidation theory and Terzaghi’s effective stress principle. The influence of the dissipation of negative excess porewater pressure on earth pressure inside and outside a foundation pit and the stability of the retaining structure were analyzed through a numerical example. It was indicated that the dissipation of negative excess porewater pressure is harmful to the stability of the retaining structure and that rapid construction can make full use of the negative porewater pressure.
基金The National Basic Research Program (973) of China (No. 2004CB418505)
文摘Under the optimal condition of copper ions adsorption on yeast,we found some different effects among static adsorption, shaking adsorption and negative pressure cavitation adsorption, and the methods of yeast with different pretreatments also affect adsorption of copper ions. At the same time, the change of intercellular pH before and after adsorption of copper with BCECF was studied. The copper distribution was located by using PhenGreen (dipotassium salt and diacetate), and the surface of yeast was observed by an atomic force microscope. The results showed that negative pressure cavitation can improve bioadsorption capacity of copper ions on yeast. However, the yeasts' pretreatment has a higher effect on bioadsorption. It indicates that heavy metal bioadsorption on yeast has much relation with its cellular molecule basis. With the adsorping, the intercellular pH of yeast increased gradually and changed from acidity to alkalescence. These results may suggest that negative pressure cavitation can compel heavy metals to transfer from the cell surface into inside cell and make the surface of yeast coarse.
基金supported by the National High-Technology Research and Development Program of China (863 Program, 2013AA102900-3)
文摘Effects of continuous negative pressure water supply on water consumption, growth and development, as well as physiological mechanism and quality of Capsicum annuum L. were investigated in this paper. Meanwhile, the optimal negative pressure water supply conditions for growth of C. annuum L. were screened out to achieve the goals of water conservation, high yield and high quality, thus providing theoretical foundation for its field production. The pot experiment within the greenhouse was utilized; the continuous negative pressure water supply was adopted; the four treatments, artificial watering(CK), –5 k Pa(T1), –10 k Pa(T2), and –15 k Pa(T3) were set; and the daily water consumption, yield, as well as the biomass, nitrate reductase, root activity, vitamin C, capsaicin, and nutrient uptakes of nitrogen(N), phosphorus(P) and potassium(K) during various stages of its growth were determined. Compared with CK, when the water supply pressure was controlled at –5 to –15 k Pa in the experiment, the total water consumption of C. annuum L. reduced by 53.42 to 67.75%, the total water consumption intensity reduced by 54.29 to 67.14%, and the water use efficiency increased by 12.66 to 124.67%. The N accumulation in a single strain of C. annuum L. from the color turning stage to the red ripe stage increased by 15.99 to 100.55%, respectively, compared with that of CK; the P accumulation increased by 20.47 to 154.00% relative to that of CK, and the K accumulation increased by 64.92 to 144.9% compared with that of CK. Compared with CK, C. annuum L. yield was remarkably improved by 13.79% at T1, and contents of vitamin C, capsaicin as well as carotenoids at all growth stages were enhanced by 13.42–147.01%, 11.54–71.01%, and 41.1–568.06%, respectively. Nitrate reductase activity, root activity and chlorophyll(a+b) were markedly increased by 335.78–500%, 79.6–140.68% and 114.95–676.19%, respectively, from immature stage to full ripe stage. Adopting the continuous negative pressure water supply for C. annuum L. has a significant water-saving effect, and the water supply pressure being stable at –5 k Pa contributes to its growth and development, improves yield, enhances root activity, promotes nutrient uptake, and improves its quality, thus achieving the effects of water conservation, high yield, high quality and high efficiency.
文摘Presented a new coal dust control program that was airtight negative pressure dust-control technology at the transpersite,combining with analysis with the movement of air currents and numerical simulation of gas-solid flow at the transpersite,and proved the mechanism of precipitation and proliferation for coal dust-controlt in theory.The technol- ogy has made good economic results at the Heidaigou Clean Plant,not only dust concen- tration control within 10 mg/m^3 to the work site,but also substantial energy savings and cost savings.
基金the National Standardization Project of TCM(ZYBZH-C-TJ-55)and National Science and Technology Major Project(2018ZX09201011-002).
文摘The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass and particle size.The pressure fluctuation signals are analyzed by the time and the frequency domain methods.A method for absolutely characterizing the degree of the energy concentration at the main frequency is proposed,where the calculation is to divide the original power spectrum by the average signal power.A phenomenon where the gas velocity curve temporarily stops growing is observed when the material mass is light,and the particle size is small.The standard deviation and kurtosis both rapidly change at the minimum fluidization velocity and thus can be used to determine the flow regime,and the variation rule of the kurtosis is independent of both the material mass and particle size.In the initial fluidization stage,the dominant pressure signal comes from the material movement;with the increase in the gas velocity,the power of a 2.5 Hz signal continues to increase.A method of dividing the main frequency by the average cycle frequency can conveniently determine the fluidized state,and a novel concept called stable fluidized zone proposed in this paper can be obtained.Controlling the gas velocity within the stable fluidized zone ensures that the fluidized bed consistently remains in a stable fluidized state.
基金Supported by the National Natural Science Foundation of China under Grant Nos 81127901,81420108018,81527803,81227004 and 11374155the Natural Science Foundation of Jiangsu Province under Grant No BK20131017+3 种基金the Main Scientific and Technological Project of Zhejiang Province under Grant No 2013C03044-1the Chinese Postdoctoral Science Foundation under Grant No134238the Postdoctoral Foundation of Jiangsu Province under Grant No 1401001Bthe Qing Lan Project
文摘The relationship between the cavitation and acoustic peak negative pressure in the high-intensity focused ultrasound (HIFU) field is analyzed in water and tissue phantom. The peak negative pressure at the focus is determined by a hybrid approach combining the measurement with the simulation. The spheroidal beam equation is utilized to describe the nonlinear acoustic propagation. The waveform at the focus is measured by a fiber optic probe hydrophone in water. The relationship between the source pressure amplitude and the excitation voltage is determined by fitting the measured ratio of the second harmonic to the fundamental component at the focus, based on the model simulation. Then the focal negative pressure is calculated for arbitrary voltage excita- tion in water and tissue phantom. A portable B-mode ultrasound scanner is applied to monitor HIFU-indueed cavitation in real time, and a passive cavitation detection (PCD) system is used to acquire the bubble scattering signals in the HIFU focal volume for the cavitation quantification. The results show that: (1) unstable cavitation starts to appear in degassed water when the peak negative pressure of HIFU signals reaches 13.5 MPa; and (2) the cavitation activity can be detected in tissue phantom by B-mode images and in the PCD system with HIFU peak negative pressures of 9.0 MPa and 7.8 MPa, respectively, which suggests that real-time B-mode images could be used to monitor the cavitation activity in two dimensions, while PCD systems are more sensitive to detect scattering and emission signals from cavitation bubbles.
文摘BACKGROUND Thermal injuries on free transferred or replanted tissues resulting from loss of sensibility are an infrequent occurrence.They require immediate and appropriate management before they progress to an irreversible condition.Although negative pressure wound therapy(NPWT)can prevent wound progression by increasing microcirculation,the inappropriate application of NPWT on complicationthreatened transferred and replanted tissues can induce an adverse effect.CASE SUMMARY A 48-year-old woman who underwent immediate breast reconstruction with a deep inferior epigastric artery perforator free flap.While applying a heating pad directly to the flap site,she sustained a deep second to third-degree contact burn over 30%of the transferred flap on postoperative 7 d.As the necrotic changes had progressed,we applied an NPWT dressing over the burned area after en-bloc debridement of the transferred tissues on postoperative 21 d.After 4 d of NPWT application,the exposed fatty tissues of the flap changed to dry and browncolored necrotic tissues.Upon further debridement,we noted that the wound gradually reached total necrosis with a collapsed vascular pedicle of deep inferior epigastric artery.CONCLUSION Although NPWT has been shown to be successful for treating various wound types,the significant risk of NPWT application in short-lasting reconstructed flap wounds after thermal injury should be reminded.
文摘A series of experiments on a solid feed system was performed to investigate the effect of negative pressure gradient on the gas-solid flow pattern and hydrodynamic characteristics.Based on the non-fluidized gas-solid two phase flow and particulate mechanics in the standpipe,a method for predicting the pressure of the air passing through the recycle chamber and the pressure drop through the loop seal slit in these systems is also presented.The predicted pressure profile along the negative pressure gradient from the proposed model exhibits a good agreement with the experimental data.The experimental data show that the gas flow in the standpipe is always upward in the negative pressure gradients,while the direction ofthe superficial gas velocity through the recycle chamber of the loop seal does not affect the pressure drop in standpipe.It increases with an increasing negative pressure gradient.
基金Supported by National Natural Science Foundation of China(No. 51109160)National High Technology Research and Development Program of China ("863" Program, No. 2012AA051705)International Science and Technology Cooperation Program of China (No. 2012DFA70490)
文摘Cover-bearing-type bucket foundation for offshore wind turbines has been paid more and more attention due to its low cost and great bearing capacity. In order to ensure the cover-bearing mode, the muddy soil inside the bucket foundation should be reinforced by some soil consolidation methods, such as negative pressure and electro-osmosis. Firstly, tests were conducted to obtain the reasonable current density. Meanwhile, to improve the electro-osmotic speed and effectiveness, other factors such as intermittent power and layout of electrode, were also studied in the tests. Then, the soil reinforcing tests by negative pressure combined with electro-osmosis were performed for the muddy soil consolidation inside the bucket foundation. The results showed that soil reinforcement by negative pressure was quicker and more obvious during the early phase, and electro-osmotic method can affect more range of soil by rational arrangement of electrodes. Compared with negative pressure, the electro-osmotic method was a continuous and relatively slow process of reinforcement, which was complementary to the negative pressure method. The voltage value of electro-osmosis had little effect on the muddy soil reinforcement inside the bucket foundation, and 1.5 A was chosen as the most reasonable current value for scale model testing in the electro-osmotic method.
文摘Background: Septic open abdomens occur in trauma, burn and surgery. Currently, multiple concentrations of hypochlorous acid solutions have effectively decreased the microbiotic burden in wounds. We hypothesized that Vashe?, a neutral hypochlorous acid solution (V-HOCL), would be safe as an intraperitoneal irrigation or washout disinfectant for septic open abdomens utilizing negative pressure wound therapy. Methods: This is a retrospective observational review of patients who required delayed abdominal closures after exploratory laparotomies. Group A (n = 8) had cyclical V-HOCL irrigation to their open abdomens combining AbtheraTM and V.A.C. Dressing System for negative pressure wound therapy with irrigation (NPWT-i) and Group B (n = 9) had intra-abdominal V-HOCL washouts. Results: Fifty percent of both groups had either septic or hemorrhagic shock on admission. Compared to Group B, Group A patients were older (median 50 vs 37 years), and had a median hospitalization of 28 vs 8 days, 4 times as many operations, more acute renal failure and co-morbidities. No statistically significant differences were detected be-tween the two treatment methods with the V-HOCL delivery and removal. Conclusion: There were no episodes of electrolyte imbalance, hypotension, hypertension, anaphylaxis, hemorrhage, visceral injury or systemic toxicity. V-HOCL with/without NPWT-i irrigation was a safe modality and tolerated well in this study.
基金This work was partially supported by the Hungarian Science Foundation (OTKA F034333). The author was also supported by the Bolyai Research Fellowship.
文摘In this paper we would like to give a brief review about the extensibility of the liquid-liquid locus into the negativepressure region. Negative pressure states are hardly explored; most researchers believe that the pressure scale ends at p = 0.We would like to show that this is not true, the p = 0 point is not a special point for liquids, it can be 'easily' crossed. We aregoing to give a few example, where the extension of liquid-liquid locus for polymer blends and solutions below p = 0 givesus some interesting results, like the merging of UCST and LCST branches in weakly interacting polymer solutions or thereason why most UCST blends exhibit pressure induced immiscibility. Also, we will see what happens with the immiscibilityisland of aqueous polymer solutions when -- reaching the critical molar mass -- it 'disappears'.
基金Project supported by the National Natural Science Foundation of China (Nos. 10772104 and 10872045)the Innovation Project of Shanghai Municipal Education Commission (No. 09YZ12)the Shanghai Leading Academic Discipline Project (No. S30106)
文摘Mechanical properties, such as the deformation and stress distributions for venous walls under the combined load of transmural pressure and axial stretch, are examined within the framework of nonlinear elasticity with one kind of hyper-elastic strain energy functions. The negative pressure instability problem of the venous wall is explained through energy comparison. First, the deformation equation of the venous wall under the combined loads is obtained with a thin-walled circular cylindrical tube. The deformation curves and the stress distributions for the venous wall are given under the normal transmural pressure, and the regulations are discussed. Then, the deformation curves of the venous wall under the negative transmural pressure or the internal pressure less than the external pressure are given. Finally, the negative pressure instability problem is discussed through energy comparison.
基金Supported by the Multicenter Clinical Trial of hUC-MSCs in the Treatment of Late Chronic Spinal Cord Injury,No.2017YFA0105404the Key Discipline Construction Project of Pudong Health Bureau of Shanghai,No.PWZxk2017-08.
文摘BACKGROUND Postoperative unobstructed drainage is an important measure for avoiding hematoma formation and preventing complications from anterior cervical surgery.AIM To discuss the characteristics and key points of clinical management of two types of commonly used negative pressure drainage systems in clinical settings.METHODS Two types of commonly used silica gel negative pressure drainage balls and a type of gastrointestinal decompression apparatus were fully emptied and then injected with different amounts of water and air.Following this,the negative pressure values of the three devices were measured.Meanwhile,we undertook a retrospective analysis of the clinical data of 1328 patients who had been treated with different negative pressure drainage apparatuses during their anterior cervical surgery in our department between January 2007 and January 2018.RESULTS As the amount of injected air or water increased,the negative pressure of the silica gel negative pressure drainage ball decreased rapidly,dropping to zero when 150 mL of water or air was injected.In contrast,the negative pressure of gastrointestinal decompression apparatus decreased slowly,maintaining an ideal value even when 300 mL of water or air was injected.And statistical analysis demonstrated that patients who had been treated with the gastrointestinal decompression apparatus were less likely to develop severe complications than those who had been treated with the silica gel negative pressure drainage ball(P<0.05).CONCLUSION This study showed that the gastrointestinal decompression apparatus has the advantages of large suction capacity,long duration of continuous negative pressure,and good drainage effect,all of which are the favorable factors for the use of this apparatus for negative pressure drainage in anterior cervical surgery.