期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
STUDY OF CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEW NEUTRAL CARRIER
1
作者 Wei XU Bin GUO You Rong NIE Zai Fu HUANG Department of Environmental Science,Wuhan University,430072 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第2期179-180,共2页
A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coeffic... A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coefficents are -2.3 Li(+),-3.5 Na(+),-4.0 K(+),-3.7NH_4(+),-4.5 Mg(2+) and -4.4Zn(2+). 展开更多
关键词 ETH ION STUDY OF calcium ion-selective electrode BASED ON A NEW neutral carrier PVC
下载PDF
Highly Selective Salicylate Membrane Electrode Based on N,N'- (Aminoethyl)ethylenediamide Bis(2-salicylideneimine) Binuclear Copper(Ⅱ) Complex as Neutral Carrier 被引量:1
2
作者 孙爱丽 柴雅琴 +1 位作者 袁若 归国风 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2006年第7期894-898,共5页
A new ion selective electrode for salicylate based on N,N'-(aminoethyl)ethylenediamide bis(2-salicylideneimine) binuclear copper(Ⅱ) complex [Cu(Ⅱ)2-AEBS] as an ionophore was developed. The electrode has a l... A new ion selective electrode for salicylate based on N,N'-(aminoethyl)ethylenediamide bis(2-salicylideneimine) binuclear copper(Ⅱ) complex [Cu(Ⅱ)2-AEBS] as an ionophore was developed. The electrode has a linear range from 1.0 × 10^-1 to 5.0 ×10^-7 mol·L^- 1 with a near-Nemstian slope of ( - 55 ±1 ) mV/decade and a detection limit of 2.0 × 10-7 mol·L^-1 in phosphorate buffer solution of pH 5.0 at 25 ℃. It shows good selectivity for Sal^- and displays anti-Hofmeister selectivity sequence: Sal^-〉SCN^-〉 ClO4^- 〉I^-〉 NO2^- 〉Br^-〉 NO3^- 〉Cl^-〉 SO3^2- 〉 SO4^2- The proposed sensor based on binuclear copper(Ⅱ)complex has a fast response time of 5-10 s and can be used for at least 2 months without any major deviation. The response mechanism is discussed in view of the alternating current (AC) impedance technique and the UV-vis spectroscopy technique. The effect of the electrode membrane compositions and the experimental conditions were studied. The electrode has been successfully used for the determination of salicylate ion in drug pharmaceutical preparations. 展开更多
关键词 N N'-(aminoethyl)ethylenediamide bis(2-salicylideneimine) binuclear copper(Ⅱ) neutral carrier SALICYLATE ion-selective electrode
原文传递
新型钙离子选择电极测定血清中总钙 被引量:1
3
作者 黄载福 徐伟 +4 位作者 郭斌 唐玉蓉 甘宗仁 王运程 万卉芳 《分析化学》 SCIE EI CAS CSCD 北大核心 1993年第9期1058-1060,共3页
本文研制成一种新型开链酰胺的PVC膜钙离子选择电极。应用于临床,测定了85个血清样品中的总钙,其结果与AAS法和比色法的测定结果相一致,该电极在对血清的测量中显示出良好的重现性、稳定性和准确性。
关键词 离子选择电极 血清 钙离子
下载PDF
开链酰胺冠醚PVC膜钙离子选择电极研究 被引量:1
4
作者 黄载福 郭斌 +3 位作者 徐伟 聂友蓉 胡凯 汪玉庭 《武汉大学学报(自然科学版)》 CSCD 1993年第4期35-40,共6页
以8个不同结构的开链酰胺型冠醚(Ⅰ~Ⅷ,其中Ⅷ为环酰胺)为传感活性物质,研制了钙离子选择电极,其中以 N,N,N′,N′,-四环己基-3,6-二氧辛二酰胺(即冠醚Ⅱ)PVC 膜钙电极的综合性能最好,在缓冲溶液中测定,响应斜率:28 mV·(dec... 以8个不同结构的开链酰胺型冠醚(Ⅰ~Ⅷ,其中Ⅷ为环酰胺)为传感活性物质,研制了钙离子选择电极,其中以 N,N,N′,N′,-四环己基-3,6-二氧辛二酰胺(即冠醚Ⅱ)PVC 膜钙电极的综合性能最好,在缓冲溶液中测定,响应斜率:28 mV·(dec)-1线性范围:6.3×10-~10-mol·L-1CaCl2;检测下限:2.5×10-9mol·L-1CaCl2;在非缓冲溶液中,斜率为29.d mV·(dec)-1,线性范围;1.4×10-6~1×10-1mol·L-1。CaCl2,检测下限:7.4×10-7mol·L-1 CaCl2,对 Li+,Na+,K+,NH4+,Mg2+,Zn2+等干扰离子的选择系数分别为4.7×10-3,3.0×10-4,1.1×10-4,1.7×10-4,2.8×10-5,4.5×10-4. 展开更多
关键词 冠醚 开链二酰胺 离子选择电极
下载PDF
冠醚化合物的合成(ⅩⅪ)——开链酰胺型冠醚的合成及其钙离子选择电极的性能 被引量:3
5
作者 郭斌 徐伟 +3 位作者 刘冬 黄载福 谌了蓉 罗宝生 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 1993年第5期630-633,共4页
本文以多甘醇为原料,经氧化、取代反应制备了多甘酰氯,再与仲胺反应,合成了7个开链酰胺型冠醚化合物和1个酰胺型大环化合物,除冠醚(Ⅰ)外,其余均未见文献报道。它们的结构经红外、核磁、质谱和元素分析数据确认,并用四圆单晶X射线衍射... 本文以多甘醇为原料,经氧化、取代反应制备了多甘酰氯,再与仲胺反应,合成了7个开链酰胺型冠醚化合物和1个酰胺型大环化合物,除冠醚(Ⅰ)外,其余均未见文献报道。它们的结构经红外、核磁、质谱和元素分析数据确认,并用四圆单晶X射线衍射仪测定了冠醚(Ⅱ)单晶的晶体结构,进一步从理论上说明了它是优良的钙离子选择电极的中性载体。 展开更多
关键词 冠醚 开链酰胺 离子选择电极
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部