It is a known fact that the epileptic power situation in Nigeria has become a recurring decimal. In the light of this stark reality of a country like Nigeria which is constantly plunged into pitch darkness all year ro...It is a known fact that the epileptic power situation in Nigeria has become a recurring decimal. In the light of this stark reality of a country like Nigeria which is constantly plunged into pitch darkness all year round, it has become expedient for a sustainable and urgent remedy to be sought if our country will ever think of rubbing shoulders with the economies of the world. It is this pathetic scenario, we find ourselves in that it has given rise to this paper which tends to review possible ways and means of redressing the ugly trend. This paper examines the prospects and possible applications of Smart Grid Technology (SGT) to the Nigeria Power System. Nigeria Power System consists of 28 buses, 32 Transmission lines and 10 generating stations, with a view to reduce the high active and reactive transmission losses. The study shows that smart grid system will make the present network more efficient and reliable by connecting different sources of distributed generators into the existing grid. Basic requirements necessary for the application of SGT using the Nigeria Power System as a case study were discussed.展开更多
The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the oc...The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the occurrence of a disturbance or fault cannot be completely avoided, hence, when it occurs, control measures need to be put in place to limit the fault current, which invariably limit the level of the disturbances. This paper explores the use of Superconductor Fault Current Limiter (SFCL) to improve the transient stability of the Nigeria 330 kV Transmission Network. During a large disturbance, the rotor angle of the generator is enhanced by connecting a Fault Current Limiter (FCL) which reduces the fault current and hence, increases transient stability of the power network. In this study, the most affected generator was taken into consideration in locating the SFCL. The result obtained reveals that the Swing Curve of the generator without FCL increases monotonically which indicates instability, while the Swing Curve of the System with FCL reaches steady state.展开更多
文摘It is a known fact that the epileptic power situation in Nigeria has become a recurring decimal. In the light of this stark reality of a country like Nigeria which is constantly plunged into pitch darkness all year round, it has become expedient for a sustainable and urgent remedy to be sought if our country will ever think of rubbing shoulders with the economies of the world. It is this pathetic scenario, we find ourselves in that it has given rise to this paper which tends to review possible ways and means of redressing the ugly trend. This paper examines the prospects and possible applications of Smart Grid Technology (SGT) to the Nigeria Power System. Nigeria Power System consists of 28 buses, 32 Transmission lines and 10 generating stations, with a view to reduce the high active and reactive transmission losses. The study shows that smart grid system will make the present network more efficient and reliable by connecting different sources of distributed generators into the existing grid. Basic requirements necessary for the application of SGT using the Nigeria Power System as a case study were discussed.
文摘The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the occurrence of a disturbance or fault cannot be completely avoided, hence, when it occurs, control measures need to be put in place to limit the fault current, which invariably limit the level of the disturbances. This paper explores the use of Superconductor Fault Current Limiter (SFCL) to improve the transient stability of the Nigeria 330 kV Transmission Network. During a large disturbance, the rotor angle of the generator is enhanced by connecting a Fault Current Limiter (FCL) which reduces the fault current and hence, increases transient stability of the power network. In this study, the most affected generator was taken into consideration in locating the SFCL. The result obtained reveals that the Swing Curve of the generator without FCL increases monotonically which indicates instability, while the Swing Curve of the System with FCL reaches steady state.