Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and...Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and analyze their application values.Methods:Fifty patients with suspected occupational noise-induced hearing loss were randomly selected from the Department of Otolaryngology at the hospital as the research target.The collection period for the research cases spanned from January 2022 to November 2023,and all patients had a history of noise exposure.The DIN test and HHIA-S were used for hearing examinations,with clinical,comprehensive diagnosis serving as the gold standard to study their diagnostic performance.Results:The compliance rate of the DIN test was 88.00%,the HHIA-S’s compliance rate was 80.00%,and the combined compliance rate was 94.00%.The compliance rate of the DIN test and the combined compliance rates of the patients were statistically significant compared to the clinical gold standard data(P<0.05),while there was no difference between the compliance rate of the HHIA-S and the gold standard(P>0.05).The data shows that the sensitivity of the combined diagnosis is significantly higher than the sensitivity data of the DIN test and HHIA-S examination alone(P<0.05).Its specificity is 100.00%,and the accuracy data of the joint diagnosis in the degree were higher than those of the DIN test alone(P>0.05)and the HHIA-S alone(P<0.05).Conclusion:For patients with occupational noise-induced hearing loss,the joint evaluation of the DIN test and HHIA-S can significantly improve their diagnostic value with high sensitivity and accuracy.展开更多
Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-freque...Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-frequency-hearing- threshold-weighted values (HFTWVs). Methods: A retrospective study was conducted to evaluate the diagnosis of patients with ONID from January 2016 to January 2017 in Guangdong province, China. Based on 3 hearing tests (each interval between the tests was greater than 3 days), the minimum threshold value of each frequency was obtained using the 2007 edition’s diagnostic criteria for ONID. The speech frequency and the HFTWVs were analyzed based on age, noise exposure, and diagnostic classi-fication using SPSS21.0. Results: 168 patients in total were involved in this study, 154 males and 14 females, and the average age was 41.18 ± 6.07. The diagnosis rate was increased by the weighted value of the high frequencies and was more than the mean value of the pure speech frequency (MVPSF). The diagnosis rate for the weighted 4 kHz frequency level increased by 13.69% (χ2 = 9.880, P = 0.002), the weighted 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002), and the weighted 4 kHz + 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002). The differences were all statistically significant. The diagnostic rate of the different thresholds showed no obvious difference between the genders. The age groups were divided into less than or equal to 40 years old (group A) and 40 - 50 years old (group B). There were several groups with a high frequency: high frequency weighted 4 kHz ( group A χ2 = 3.380, P = 0.050;group B χ2 = 4.054, P = 0.032), high frequency weighted 6 kHz (group A χ2 = 6.362, P = 0.012;group B χ2 = 4.054, P = 0.032), weighted 4 kHz + 6 kHz (group A χ2 = 6.362 P = 0.012;B χ2 = 4.054, P = 0.032) than those of MVPSF in the same group on ONID diagnosis rate. The differences between the groups were statistically significant. There was no significant difference between the age groups (χ2 = 2.265, P = 0.944). The better ear’s (the smaller hearing threshold weighted value) MVPSF and the weighted values for the different high frequencies were examined in light of the number of working years;the group that was exposed to noise for more than 10 years had significantly higher values than those of the average thresholds of each frequency band in the groups with 3 - 5 years of exposure (F = 2.271, P = 0.001) and 6 - 10 years of exposure (F = 1.563, P = 0.046). The differences were statistically significant. The different HFTWVs were higher than those of the MVPSF values, and the high frequency weighted 4 kHz + 6 kHz level showed the greatest difference, with an average increase of 2.83 dB. The diagnostic rate that included the weighted high frequency values was higher for the mild, moderate, and severe cases than those patients who were only screened with the pure frequency tests. The results of the comparisons of the diagnosis rates for mild ONID were as follows: the weighted 3 kHz high frequency level (χ2 = 3.117, P = 0.077) had no significant difference, but the weighted 4 kHz level (χ2 = 10.835, P = 0.001), 6 kHz level (χ2 = 9.985, P = 0.002), 3 kHz + 4 kHz level (χ2 = 6.315, P = 0.012), 3 kHz + 6 kHz level (χ2 = 6.315, P = 0.012), 4 kHz + 6 kHz level (χ2 = 9.985, P = 0.002), and 3 kHz + 4 kHz + 6 kHz level (χ2 = 7.667, P = 0.002) were significantly higher than the diagnosis rate of the mean value of the PSF. There was no significant difference between the 2 groups for the moderate and severe grades (P > 0.05). Conclusion: Different HFTWVs increase the diagnostic rate of ONID. The weighted 4 kHz, 6 kHz, and 4 kHz + 6 kHz high frequency values greatly affected the diagnostic results, and the weighted 4 kHz + 6 kHz high frequency hearing threshold value has the maximum the effect on the ONID diagnosis results.展开更多
Noise is known that the physical risk factors defined as any unwanted sound. It can induce the health problems such as hearing loss or annoyance. The objective of this study was to assess the occupational noise exposu...Noise is known that the physical risk factors defined as any unwanted sound. It can induce the health problems such as hearing loss or annoyance. The objective of this study was to assess the occupational noise exposure of nine groups for twenty peoples according to job characteristics and to compare the noise level by different variables. Personal noise levels were measured for three times using by dosimeters for each participant in Korea. The mean time weighted average noise level (TWA) of total was 73.2 ± 11.5 dBA by American conference of governmental industrial hygienists (ACGIH) standard. Especially, Korean classical music students were highly exposed to 93.2 ± 6.2 dBA but, office workers were 63.2 ± 6.6 dBA. In case of peak sound pressure level (Lpeak), Korean classical music students and firefighters were exposed to the highest level of 151.8 dBC and 145.8 dBC during playing and dispatching, respectively. The analysis of noise level showed that Leq had positive correlations between TWA by ministry of employment and labour (MOEL) (r = 0.98, p < 0.01) and TWA by ACGIH (r = 0.98, p < 0.01). Unlikely other groups, the noise exposure level of the Korean classical music students were exceeded the ACGIH standard. These results suggest that Korean classical music students were exposed high noise level and some solutions are need to reduce the noise exposure level such as using hearing protect device.展开更多
For the past few years, noise pollution has been more and more serious, and it may lead to several diseases. While the humans expose to noise in quantity for a long time, their blood pressure will change, and even cau...For the past few years, noise pollution has been more and more serious, and it may lead to several diseases. While the humans expose to noise in quantity for a long time, their blood pressure will change, and even cause changes in cardiac function. In our study, we attempt to find the relationship between occupational noise and hypertension and impaired hearing, cardiac function. It may be helpful to obtain some useful information on occupational noise exposure of humans. The participants were divided into noisy group ≥90 dB (A) and non-noisy group ≤70 dB (A). We performed this research in an automobile manufacturing company of Chongqing, China during 2011-2012. Our study showed that there may be positive associations between?occupational noise and hypertension and impaired hearing, but no conclusion can be drawn between occupational noise and ECG.展开更多
The main objectives of this study was measuring levels of noise generated by machinery that workers at metal industrial facilities in the Kingdom of Saudi Arabia (KSA) are exposed to as well as to determine if these...The main objectives of this study was measuring levels of noise generated by machinery that workers at metal industrial facilities in the Kingdom of Saudi Arabia (KSA) are exposed to as well as to determine if these levels were in conformity with adopted standards. To achieve the objectives of this study the following six metal industrial facilities were selected: a foundry plant, a building-metal production factory, a cold processing steel manufacturing plant, a hollow-metal door and doorframe manufacturer, a car-exhaust-system factory and a metal-can producer. The study found that workers operating machinery without any kind of protection were exposed to unacceptably high levels of noise that exceeded the internationally acceptable values as per occupational noise exposure-1910.95 regulations adopted standard. It was founded that 73% of work site investigated have noise level over 85 dB. A level of 116 dB was recorded at steel plant fiat section product with continuous occupation and 115.2 dB in metal product factory with labor continuous occupation. Based on the results obtained in this study, it is evident that a competent environmental and health agency needs to be established and that stricter noise-level standards ought to be enforced in order to protect employee health.展开更多
Purpose: To investigate whether long-term noise exposure affects the cognitive ability of grinders. Methods: Cumulative noise exposure (CNE) and LAeq.8h determination were used to characterize the level of individual ...Purpose: To investigate whether long-term noise exposure affects the cognitive ability of grinders. Methods: Cumulative noise exposure (CNE) and LAeq.8h determination were used to characterize the level of individual noise exposure;the Montreal Cognitive Assessment (MoCA) test (Beijing version) was used to evaluate cognitive function. Results: We compared the basic situation of workers in different groups and individual noise exposure intensity of grinders was monitored. Multiple linear-regression analysis was made and score of MoCA in different group was finally drawn. Conclusion: CNE and total score of MoCA have the relationship of negative correlation (r = -0.303, p < 0.05) which means long-term occupational noise exposure can affect the cognitive ability of grinders.展开更多
Noise is one of the most common occupational hazards worldwide[1], and millions of workers are exposed to harmful levels of noise in the workplace[2]. Noise-induced hearing loss(NIHL) is a leading cause of occupationa...Noise is one of the most common occupational hazards worldwide[1], and millions of workers are exposed to harmful levels of noise in the workplace[2]. Noise-induced hearing loss(NIHL) is a leading cause of occupational and recreational injury and disease[3]. There is evidence that occupational noise exposure is also associated with other health effects, such as hypertension and cardiovascular diseases, digestive disorders, behavioral disorders.展开更多
Objective: To define difference scores between PTA, ASSR and CERA thresholds in subjects with occupational NIHL.Design: 44 subjects undergoing a medico-legal expert assessment for occupational NIHL and fulfillingcrite...Objective: To define difference scores between PTA, ASSR and CERA thresholds in subjects with occupational NIHL.Design: 44 subjects undergoing a medico-legal expert assessment for occupational NIHL and fulfillingcriteria of reliability were considered. Assessment included: PTA, 40 Hz binaural multiple ASSR and CERA(1-2-3 kHz).Results: The respective average difference scores (ASSR - PTA) for 1, 2 and 3 kHz are 13.01 (SD 10.19) dB,12.72 (SD 8.81) dB and 10.38 (SD 8.19) dB. The average (CERA - ASSR) difference scores are 1.25 (SD 14.63)dB for 1 kHz (NS), 2.73 (SD 13.03) dB for 2 kHz (NS) and 4.51 (SD 12.18) dB for 3 kHz. The correlationbetween PTA and ASSR (0.82) is significantly stronger than that between PTA and CERA (0.71). In a givensubject, PTA thresholds are nearly always lower (i.e., better) than ASSR thresholds, whatever the frequency (1-2-3 kHz) and the side (right e left). A significant negative correlation is found between thedifference score (ASSR e PTA) and the degree of hearing loss.Conclusion: ASSR outperforms CERA in a medicolegal context, although overestimating the behavioralthresholds by 10e13 dB.展开更多
Background: Occupational noise can induce hearing impairment. Work-related hearing impairment has become a growing threat to medical practitioners who feel anxious about occupational noise exposure and its health outc...Background: Occupational noise can induce hearing impairment. Work-related hearing impairment has become a growing threat to medical practitioners who feel anxious about occupational noise exposure and its health outcomes or even experience auditory dysesthesia (including drumming, distending pain in the ears, and otalgia) after long-term exposure to a noisy work environment. Objective: To investigate the effects of occupational noise on the hearing ability of outpatient clinic nurses in Grade III, Level A and Grade II, Level A hospitals in Guangzhou. Methods: During June 2019, noise monitoring was performed by quantifying the noise levels at four measuring points (reception, waiting area, hallway, blood-sampling room) in five Grade III, Level A and five Grade II, Level A hospitals, in Guangzhou, four times a day (8 AM, 10 AM, 2 PM, and 4 PM) for 19 working days, using a professional noise measuring application for smartphones. The measurements were verified and used to create a database in Excel. Data analysis was conducted using SPSS22.0, and questionnaires were distributed to nurses who had been working at outpatient clinics for five years and above to assess the impacts of occupational noise exposure on the hearing ability. Results: In the Grade III, Level A hospitals, the sound levels at the four measuring points during the specific time periods were 4.92 - 6.75 dB above the permissible limit of 55 dB and were all significantly higher than the sound levels at the outpatient clinics of the Grade II, Level A hospitals (P Conclusions: Exposure to excess noise can lead to auditory dysesthesia in outpatient clinic nurses. Compared to those from Grade II, Level A hospitals, outpatient clinic nurses from Grade III, Level A hospitals are at higher risk of auditory dysesthesia. The noise levels at outpatient clinics should be closely monitored, and effective measures should be taken to reduce occupational noise exposure. Outpatient clinic nurses should enhance protective measures and receive preventive health exams on a regular basis.展开更多
Occupational noise is commonly encountered during aquaculture. This study documented noise levels in two buildings at a production fish hatchery, a tank room with 32, 1.8-m diameter tanks, and a rearing pavilion with ...Occupational noise is commonly encountered during aquaculture. This study documented noise levels in two buildings at a production fish hatchery, a tank room with 32, 1.8-m diameter tanks, and a rearing pavilion with 32, 6.1-m diameter tanks. With water flowing to all of the tanks in the tank room, mean noise levels were 68.4 dB, and significantly increased to 73.0 dB during tank cleaning and 73.2 dB when intermittent automatic feeders were running. The highest tank room values of 77.1 dB were recorded directly next to individual tanks during cleaning. With water flowing to all of the tanks in the rearing pavilion, mean noise levels were 70.2 dB. A significant increase to 76.1 dB was observed when the pavilion tanks were being power washed, with the highest value of 83.2 dB recorded immediately adjacent to the power washer. Although none of the noise levels exceeded regulatory limits, the use of techniques to reduce occupational noise in aquaculture environments is recommended.展开更多
Acoustic performance of dissipative silencer was evaluated to determine the effectiveness of perforated duct porosity and absorbent material density in reducing occupational noise exposure propagated from centrifugal...Acoustic performance of dissipative silencer was evaluated to determine the effectiveness of perforated duct porosity and absorbent material density in reducing occupational noise exposure propagated from centrifugal fan.Design charts were applied to predict noise reduction and length of a dissipative silencer.Dissipative silencers with various punched duct porosity(14%,30%and 40%)and sound absorbent density(80 Kg/m^(3),120 Kg/m^(3),and 140 Kg/m^(3))were designed and fabricated.According to ISO9612 and ISO11820,noise level was measured before and after installing all nine test silencers at fixed workstations around the discharge side of a centrifugal fan in a manufacturing plant.On average,the noise level at the discharge side of a fan without silencer was measured to be 93.6 dBA,whereas it was significantly mitigated by 67.4 dBA to 70.1 dBA after installing all silencers.Dynamic insertion loss for a dissipative silencer with 100 cm length was predicted to be 27.9 dB,which was in agreement with experimental ones.Although,there was no significant differences between insertion loss of silencers,the one with 30%porosity and 120 Kg/m^(3)rock wool density had the highest insertion loss of 26.2 dBA.Dissipative silencers noticeably reduced centrifugal fan noise exposures.Increasing sound absorbent density and duct porosity up to a certain limit could probably be effective in noise reduction of dissipative silencers.展开更多
Weak signal reception is a very important and challenging problem for communication systems especially in the presence of non-Gaussian noise,and in which case the performance of optimal linear correlated receiver degr...Weak signal reception is a very important and challenging problem for communication systems especially in the presence of non-Gaussian noise,and in which case the performance of optimal linear correlated receiver degrades dramatically.Aiming at this,a novel uncorrelated reception scheme based on adaptive bistable stochastic resonance(ABSR)for a weak signal in additive Laplacian noise is investigated.By analyzing the key issue that the quantitative cooperative resonance matching relationship between the characteristics of the noisy signal and the nonlinear bistable system,an analytical expression of the bistable system parameters is derived.On this basis,by means of bistable system parameters self-adaptive adjustment,the counterintuitive stochastic resonance(SR)phenomenon can be easily generated at which the random noise is changed into a benefit to assist signal transmission.Finally,it is demonstrated that approximately 8dB bit error ratio(BER)performance improvement for the ABSR-based uncorrelated receiver when compared with the traditional uncorrelated receiver at low signal to noise ratio(SNR)conditions varying from-30dB to-5dB.展开更多
This paper outlines a plan for the effective reduction of the audible sound level produced by aerodynamic noise from the power-generating turbine blades. The contribution of aerodynamic noise can be divided into two c...This paper outlines a plan for the effective reduction of the audible sound level produced by aerodynamic noise from the power-generating turbine blades. The contribution of aerodynamic noise can be divided into two categories: inflow turbulence and airfoil self-noise. The base model and retrofit blade designs were modeled in SolidWorks. Subsequently, noise prediction simulations were conducted and compared to the base blade model to determine which modification provided the greatest benefit using SolidWorks Flow Simulation. The result of this project is a series of blade retrofit recommendations that produce a more acoustically efficient design and reduce noise complaints while enabling turbines to be placed in locations that require quieter operations.展开更多
Reducing the aerodynamic drag and noise levels of high-speed pantographs is important for promoting environmentally friendly,energy efficient and rapid advances in train technology.Using computational fluid dynamics t...Reducing the aerodynamic drag and noise levels of high-speed pantographs is important for promoting environmentally friendly,energy efficient and rapid advances in train technology.Using computational fluid dynamics theory and the K-FWH acoustic equation,a numerical simulation is conducted to investigate the aerodynamic characteristics of high-speed pantographs.A component optimization method is proposed as a possible solution to the problemof aerodynamic drag and noise in high-speed pantographs.The results of the study indicate that the panhead,base and insulator are the main contributors to aerodynamic drag and noise in high-speed pantographs.Therefore,a gradual optimization process is implemented to improve the most significant components that cause aerodynamic drag and noise.By optimizing the cross-sectional shape of the strips and insulators,the drag and noise caused by airflow separation and vortex shedding can be reduced.The aerodynamic drag of insulator with circular cross section and strips with rectangular cross section is the largest.Ellipsifying insulators and optimizing the chamfer angle and height of the windward surface of the strips can improve the aerodynamic performance of the pantograph.In addition,the streamlined fairing attached to the base can eliminate the complex flow and shield the radiated noise.In contrast to the original pantograph design,the improved pantograph shows a 21.1%reduction in aerodynamic drag and a 1.65 dBA reduction in aerodynamic noise.展开更多
Orthogonal frequency division multiplexing passive optical network(OFDM-PON) has superior anti-dispersion property to operate in the C-band of fiber for increased optical power budget. However,the downlink broadcast e...Orthogonal frequency division multiplexing passive optical network(OFDM-PON) has superior anti-dispersion property to operate in the C-band of fiber for increased optical power budget. However,the downlink broadcast exposes the physical layer vulnerable to the threat of illegal eavesdropping. Quantum noise stream cipher(QNSC) is a classic physical layer encryption method and well compatible with the OFDM-PON. Meanwhile, it is indispensable to exploit forward error correction(FEC) to control errors in data transmission. However, when QNSC and FEC are jointly coded, the redundant information becomes heavier and thus the code rate of the transmitted signal will be largely reduced. In this work, we propose a physical layer encryption scheme based on polar-code-assisted QNSC. In order to improve the code rate and security of the transmitted signal, we exploit chaotic sequences to yield the redundant bits and utilize the redundant information of the polar code to generate the higher-order encrypted signal in the QNSC scheme with the operation of the interleaver.We experimentally demonstrate the encrypted 16/64-QAM, 16/256-QAM, 16/1024-QAM, 16/4096-QAM QNSC signals transmitted over 30-km standard single mode fiber. For the transmitted 16/4096-QAM QNSC signal, compared with the conventional QNSC method, the proposed method increases the code rate from 0.1 to 0.32 with enhanced security.展开更多
With the rapid development of emergency medicine,emergency physicians are working around the clock,[1]including additional workloads due to sudden public health emergencies and disasters.Occupational risks for emergen...With the rapid development of emergency medicine,emergency physicians are working around the clock,[1]including additional workloads due to sudden public health emergencies and disasters.Occupational risks for emergency physicians are significantly high due to an increasing number of patients with acute and severe diseases,an increased workload.展开更多
Global energy and environmental issues are becoming increasingly problematic,and the vibration and noise problem of 110 kV transformers,which are the most widely distributed,have attracted widespread attention from bo...Global energy and environmental issues are becoming increasingly problematic,and the vibration and noise problem of 110 kV transformers,which are the most widely distributed,have attracted widespread attention from both inside and outside the industry.DC bias is one of the main contributing factors to vibration noise during the normal operation of transformers.To clarify the vibration and noise mechanism of a 110 kV transformer under a DC bias,a multi-field coupling model of a 110 kV transformer was established using the finite element method.The electromagnetic,vibration,and noise characteristics during the DC bias process were compared and quantified through field circuit coupling in parallel with the power frequency of AC,harmonic,and DC power sources.It was found that a DC bias can cause significant distortions in the magnetic flux density,force,and displacement distributions of the core and winding.The contributions of the DC bias effect to the core and winding are different at Kdc=0.85.At this point,the core approached saturation,and the increase in the core force and displacement slowed.However,the saturation of the core increased the leakage flux,and the stress and displacement of the winding increased faster.The sound field distribution characteristics of the 110 kV transformer under a DC bias are related to the force characteristics.When the DC bias coefficient was 1.25,the noise sound pressure level reached 73.6 dB.展开更多
Background: Occupational dermatitis is considered as the second most common occupational disease. It accounts for 25% of all lost workdays. Several international studies reported a prevalence of occupational dermatiti...Background: Occupational dermatitis is considered as the second most common occupational disease. It accounts for 25% of all lost workdays. Several international studies reported a prevalence of occupational dermatitis in healthcare workers between 17% and 55%. This study aims to identify factors that affect the professional outcome of nurses suffering from occupational dermatitis. Methods: This was a multicenter cross-sectional study concerning nurses declared having occupational dermatitis in the central region of Tunisia. A synoptic sheet related to socio-professional and administrative data was completed. A self-administered Questionnaire going over medical and occupational characteristics was completed during a direct interview. Results: The study involved forty nurses working in four public hospitals in the center of Tunisia. Only 37 workers were included in the study. A professional reclassification was introduced among 19 workers (51% of study population). Work-station adaptation was requested in 14 cases (38%). Exposure to allergens in the workplace was eliminated in 20 cases. Two study participants were transferred to other departments (5.4%) and three people retired (8.1%). A statistically significant association was found between professional reclassification and a history of allergic manifestations (p = 0.003). Similarly, a significant association was found between professional reclassification and the allergic agent (p = 0.014). Workstation layout was significantly associated with a history of allergic manifestations (p = 0.039), the palm hand location (p = 0.04), professional eviction (p Conclusion: This study identified the main factors influencing the occupational outcome of nurses suffering from occupational dermatitis. This outcome depended on a history of atopy (especially allergic rhinitis) and sensitization to allergens (thiuram mix).展开更多
This paper presents a comprehensive framework for analyzing phase transitions in collective models such as theVicsek model under various noise types. The Vicsek model, focusing on understanding the collective behavior...This paper presents a comprehensive framework for analyzing phase transitions in collective models such as theVicsek model under various noise types. The Vicsek model, focusing on understanding the collective behaviors of socialanimals, is known due to its discontinuous phase transitions under vector noise. However, its behavior under scalar noiseremains less conclusive. Renowned for its efficacy in the analysis of complex systems under both equilibrium and nonequilibriumstates, the eigen microstate method is employed here for a quantitative examination of the phase transitions inthe Vicsek model under both vector and scalar noises. The study finds that the Vicsek model exhibits discontinuous phasetransitions regardless of noise type. Furthermore, the dichotomy method is utilized to identify the critical points for thesephase transitions. A significant finding is the observed increase in the critical point for discontinuous phase transitions withescalation of population density.展开更多
As a crucial component of terrestrial ecosystems,urban forests play a pivotal role in protecting urban biodiversity by providing suitable habitats for acoustic spaces.Previous studies note that vegetation structure is...As a crucial component of terrestrial ecosystems,urban forests play a pivotal role in protecting urban biodiversity by providing suitable habitats for acoustic spaces.Previous studies note that vegetation structure is a key factor influencing bird sounds in urban forests;hence,adjusting the frequency composition may be a strategy for birds to avoid anthropogenic noise to mask their songs.However,it is unknown whether the response mechanisms of bird vocalizations to vegetation structure remain consistent despite being impacted by anthropogenic noise.It was hypothesized that anthropogenic noise in urban forests occupies the low-frequency space of bird songs,leading to a possible reshaping of the acoustic niches of forests,and the vegetation structure of urban forests is the critical factor that shapes the acoustic space for bird vocalization.Passive acoustic monitoring in various urban forests was used to monitor natural and anthropogenic noises,and sounds were classified into three acoustic scenes(bird sounds,human sounds,and bird-human sounds)to determine interconnections between bird sounds,anthropogenic noise,and vegetation structure.Anthropogenic noise altered the acoustic niche of urban forests by intruding into the low-frequency space used by birds,and vegetation structures related to volume(trunk volume and branch volume)and density(number of branches and leaf area index)significantly impact the diversity of bird sounds.Our findings indicate that the response to low and high frequency signals to vegetation structure is distinct.By clarifying this relationship,our results contribute to understanding of how vegetation structure influences bird sounds in urban forests impacted by anthropogenic noise.展开更多
文摘Objective:To explore the clinical evaluation role of the Digits-in-Noise(DIN)test and Hearing Handicap Inventory for Adults Screening(HHIA-S)for patients with occupational noise-induced hearing loss and to observe and analyze their application values.Methods:Fifty patients with suspected occupational noise-induced hearing loss were randomly selected from the Department of Otolaryngology at the hospital as the research target.The collection period for the research cases spanned from January 2022 to November 2023,and all patients had a history of noise exposure.The DIN test and HHIA-S were used for hearing examinations,with clinical,comprehensive diagnosis serving as the gold standard to study their diagnostic performance.Results:The compliance rate of the DIN test was 88.00%,the HHIA-S’s compliance rate was 80.00%,and the combined compliance rate was 94.00%.The compliance rate of the DIN test and the combined compliance rates of the patients were statistically significant compared to the clinical gold standard data(P<0.05),while there was no difference between the compliance rate of the HHIA-S and the gold standard(P>0.05).The data shows that the sensitivity of the combined diagnosis is significantly higher than the sensitivity data of the DIN test and HHIA-S examination alone(P<0.05).Its specificity is 100.00%,and the accuracy data of the joint diagnosis in the degree were higher than those of the DIN test alone(P>0.05)and the HHIA-S alone(P<0.05).Conclusion:For patients with occupational noise-induced hearing loss,the joint evaluation of the DIN test and HHIA-S can significantly improve their diagnostic value with high sensitivity and accuracy.
文摘Objective: In order to provide a theoretical basis for the revision of the current diagnostic criteria for occupational noise-induced deafness (ONID), we evaluated the degree of ONID by analyzing different high-frequency-hearing- threshold-weighted values (HFTWVs). Methods: A retrospective study was conducted to evaluate the diagnosis of patients with ONID from January 2016 to January 2017 in Guangdong province, China. Based on 3 hearing tests (each interval between the tests was greater than 3 days), the minimum threshold value of each frequency was obtained using the 2007 edition’s diagnostic criteria for ONID. The speech frequency and the HFTWVs were analyzed based on age, noise exposure, and diagnostic classi-fication using SPSS21.0. Results: 168 patients in total were involved in this study, 154 males and 14 females, and the average age was 41.18 ± 6.07. The diagnosis rate was increased by the weighted value of the high frequencies and was more than the mean value of the pure speech frequency (MVPSF). The diagnosis rate for the weighted 4 kHz frequency level increased by 13.69% (χ2 = 9.880, P = 0.002), the weighted 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002), and the weighted 4 kHz + 6 kHz level increased by 15.47% (χ2 = 9.985, P = 0.002). The differences were all statistically significant. The diagnostic rate of the different thresholds showed no obvious difference between the genders. The age groups were divided into less than or equal to 40 years old (group A) and 40 - 50 years old (group B). There were several groups with a high frequency: high frequency weighted 4 kHz ( group A χ2 = 3.380, P = 0.050;group B χ2 = 4.054, P = 0.032), high frequency weighted 6 kHz (group A χ2 = 6.362, P = 0.012;group B χ2 = 4.054, P = 0.032), weighted 4 kHz + 6 kHz (group A χ2 = 6.362 P = 0.012;B χ2 = 4.054, P = 0.032) than those of MVPSF in the same group on ONID diagnosis rate. The differences between the groups were statistically significant. There was no significant difference between the age groups (χ2 = 2.265, P = 0.944). The better ear’s (the smaller hearing threshold weighted value) MVPSF and the weighted values for the different high frequencies were examined in light of the number of working years;the group that was exposed to noise for more than 10 years had significantly higher values than those of the average thresholds of each frequency band in the groups with 3 - 5 years of exposure (F = 2.271, P = 0.001) and 6 - 10 years of exposure (F = 1.563, P = 0.046). The differences were statistically significant. The different HFTWVs were higher than those of the MVPSF values, and the high frequency weighted 4 kHz + 6 kHz level showed the greatest difference, with an average increase of 2.83 dB. The diagnostic rate that included the weighted high frequency values was higher for the mild, moderate, and severe cases than those patients who were only screened with the pure frequency tests. The results of the comparisons of the diagnosis rates for mild ONID were as follows: the weighted 3 kHz high frequency level (χ2 = 3.117, P = 0.077) had no significant difference, but the weighted 4 kHz level (χ2 = 10.835, P = 0.001), 6 kHz level (χ2 = 9.985, P = 0.002), 3 kHz + 4 kHz level (χ2 = 6.315, P = 0.012), 3 kHz + 6 kHz level (χ2 = 6.315, P = 0.012), 4 kHz + 6 kHz level (χ2 = 9.985, P = 0.002), and 3 kHz + 4 kHz + 6 kHz level (χ2 = 7.667, P = 0.002) were significantly higher than the diagnosis rate of the mean value of the PSF. There was no significant difference between the 2 groups for the moderate and severe grades (P > 0.05). Conclusion: Different HFTWVs increase the diagnostic rate of ONID. The weighted 4 kHz, 6 kHz, and 4 kHz + 6 kHz high frequency values greatly affected the diagnostic results, and the weighted 4 kHz + 6 kHz high frequency hearing threshold value has the maximum the effect on the ONID diagnosis results.
文摘Noise is known that the physical risk factors defined as any unwanted sound. It can induce the health problems such as hearing loss or annoyance. The objective of this study was to assess the occupational noise exposure of nine groups for twenty peoples according to job characteristics and to compare the noise level by different variables. Personal noise levels were measured for three times using by dosimeters for each participant in Korea. The mean time weighted average noise level (TWA) of total was 73.2 ± 11.5 dBA by American conference of governmental industrial hygienists (ACGIH) standard. Especially, Korean classical music students were highly exposed to 93.2 ± 6.2 dBA but, office workers were 63.2 ± 6.6 dBA. In case of peak sound pressure level (Lpeak), Korean classical music students and firefighters were exposed to the highest level of 151.8 dBC and 145.8 dBC during playing and dispatching, respectively. The analysis of noise level showed that Leq had positive correlations between TWA by ministry of employment and labour (MOEL) (r = 0.98, p < 0.01) and TWA by ACGIH (r = 0.98, p < 0.01). Unlikely other groups, the noise exposure level of the Korean classical music students were exceeded the ACGIH standard. These results suggest that Korean classical music students were exposed high noise level and some solutions are need to reduce the noise exposure level such as using hearing protect device.
文摘For the past few years, noise pollution has been more and more serious, and it may lead to several diseases. While the humans expose to noise in quantity for a long time, their blood pressure will change, and even cause changes in cardiac function. In our study, we attempt to find the relationship between occupational noise and hypertension and impaired hearing, cardiac function. It may be helpful to obtain some useful information on occupational noise exposure of humans. The participants were divided into noisy group ≥90 dB (A) and non-noisy group ≤70 dB (A). We performed this research in an automobile manufacturing company of Chongqing, China during 2011-2012. Our study showed that there may be positive associations between?occupational noise and hypertension and impaired hearing, but no conclusion can be drawn between occupational noise and ECG.
文摘The main objectives of this study was measuring levels of noise generated by machinery that workers at metal industrial facilities in the Kingdom of Saudi Arabia (KSA) are exposed to as well as to determine if these levels were in conformity with adopted standards. To achieve the objectives of this study the following six metal industrial facilities were selected: a foundry plant, a building-metal production factory, a cold processing steel manufacturing plant, a hollow-metal door and doorframe manufacturer, a car-exhaust-system factory and a metal-can producer. The study found that workers operating machinery without any kind of protection were exposed to unacceptably high levels of noise that exceeded the internationally acceptable values as per occupational noise exposure-1910.95 regulations adopted standard. It was founded that 73% of work site investigated have noise level over 85 dB. A level of 116 dB was recorded at steel plant fiat section product with continuous occupation and 115.2 dB in metal product factory with labor continuous occupation. Based on the results obtained in this study, it is evident that a competent environmental and health agency needs to be established and that stricter noise-level standards ought to be enforced in order to protect employee health.
文摘Purpose: To investigate whether long-term noise exposure affects the cognitive ability of grinders. Methods: Cumulative noise exposure (CNE) and LAeq.8h determination were used to characterize the level of individual noise exposure;the Montreal Cognitive Assessment (MoCA) test (Beijing version) was used to evaluate cognitive function. Results: We compared the basic situation of workers in different groups and individual noise exposure intensity of grinders was monitored. Multiple linear-regression analysis was made and score of MoCA in different group was finally drawn. Conclusion: CNE and total score of MoCA have the relationship of negative correlation (r = -0.303, p < 0.05) which means long-term occupational noise exposure can affect the cognitive ability of grinders.
文摘Noise is one of the most common occupational hazards worldwide[1], and millions of workers are exposed to harmful levels of noise in the workplace[2]. Noise-induced hearing loss(NIHL) is a leading cause of occupational and recreational injury and disease[3]. There is evidence that occupational noise exposure is also associated with other health effects, such as hypertension and cardiovascular diseases, digestive disorders, behavioral disorders.
文摘Objective: To define difference scores between PTA, ASSR and CERA thresholds in subjects with occupational NIHL.Design: 44 subjects undergoing a medico-legal expert assessment for occupational NIHL and fulfillingcriteria of reliability were considered. Assessment included: PTA, 40 Hz binaural multiple ASSR and CERA(1-2-3 kHz).Results: The respective average difference scores (ASSR - PTA) for 1, 2 and 3 kHz are 13.01 (SD 10.19) dB,12.72 (SD 8.81) dB and 10.38 (SD 8.19) dB. The average (CERA - ASSR) difference scores are 1.25 (SD 14.63)dB for 1 kHz (NS), 2.73 (SD 13.03) dB for 2 kHz (NS) and 4.51 (SD 12.18) dB for 3 kHz. The correlationbetween PTA and ASSR (0.82) is significantly stronger than that between PTA and CERA (0.71). In a givensubject, PTA thresholds are nearly always lower (i.e., better) than ASSR thresholds, whatever the frequency (1-2-3 kHz) and the side (right e left). A significant negative correlation is found between thedifference score (ASSR e PTA) and the degree of hearing loss.Conclusion: ASSR outperforms CERA in a medicolegal context, although overestimating the behavioralthresholds by 10e13 dB.
文摘Background: Occupational noise can induce hearing impairment. Work-related hearing impairment has become a growing threat to medical practitioners who feel anxious about occupational noise exposure and its health outcomes or even experience auditory dysesthesia (including drumming, distending pain in the ears, and otalgia) after long-term exposure to a noisy work environment. Objective: To investigate the effects of occupational noise on the hearing ability of outpatient clinic nurses in Grade III, Level A and Grade II, Level A hospitals in Guangzhou. Methods: During June 2019, noise monitoring was performed by quantifying the noise levels at four measuring points (reception, waiting area, hallway, blood-sampling room) in five Grade III, Level A and five Grade II, Level A hospitals, in Guangzhou, four times a day (8 AM, 10 AM, 2 PM, and 4 PM) for 19 working days, using a professional noise measuring application for smartphones. The measurements were verified and used to create a database in Excel. Data analysis was conducted using SPSS22.0, and questionnaires were distributed to nurses who had been working at outpatient clinics for five years and above to assess the impacts of occupational noise exposure on the hearing ability. Results: In the Grade III, Level A hospitals, the sound levels at the four measuring points during the specific time periods were 4.92 - 6.75 dB above the permissible limit of 55 dB and were all significantly higher than the sound levels at the outpatient clinics of the Grade II, Level A hospitals (P Conclusions: Exposure to excess noise can lead to auditory dysesthesia in outpatient clinic nurses. Compared to those from Grade II, Level A hospitals, outpatient clinic nurses from Grade III, Level A hospitals are at higher risk of auditory dysesthesia. The noise levels at outpatient clinics should be closely monitored, and effective measures should be taken to reduce occupational noise exposure. Outpatient clinic nurses should enhance protective measures and receive preventive health exams on a regular basis.
文摘Occupational noise is commonly encountered during aquaculture. This study documented noise levels in two buildings at a production fish hatchery, a tank room with 32, 1.8-m diameter tanks, and a rearing pavilion with 32, 6.1-m diameter tanks. With water flowing to all of the tanks in the tank room, mean noise levels were 68.4 dB, and significantly increased to 73.0 dB during tank cleaning and 73.2 dB when intermittent automatic feeders were running. The highest tank room values of 77.1 dB were recorded directly next to individual tanks during cleaning. With water flowing to all of the tanks in the rearing pavilion, mean noise levels were 70.2 dB. A significant increase to 76.1 dB was observed when the pavilion tanks were being power washed, with the highest value of 83.2 dB recorded immediately adjacent to the power washer. Although none of the noise levels exceeded regulatory limits, the use of techniques to reduce occupational noise in aquaculture environments is recommended.
基金the framework of a faculty research project under the code of Ethics Committee of IR.QUMS.REC.1396.163.We also thank Mehrdad Keshavarz Siahposh and Mohammad Soleiman Abady for their technical assistance in all our experimental work.
文摘Acoustic performance of dissipative silencer was evaluated to determine the effectiveness of perforated duct porosity and absorbent material density in reducing occupational noise exposure propagated from centrifugal fan.Design charts were applied to predict noise reduction and length of a dissipative silencer.Dissipative silencers with various punched duct porosity(14%,30%and 40%)and sound absorbent density(80 Kg/m^(3),120 Kg/m^(3),and 140 Kg/m^(3))were designed and fabricated.According to ISO9612 and ISO11820,noise level was measured before and after installing all nine test silencers at fixed workstations around the discharge side of a centrifugal fan in a manufacturing plant.On average,the noise level at the discharge side of a fan without silencer was measured to be 93.6 dBA,whereas it was significantly mitigated by 67.4 dBA to 70.1 dBA after installing all silencers.Dynamic insertion loss for a dissipative silencer with 100 cm length was predicted to be 27.9 dB,which was in agreement with experimental ones.Although,there was no significant differences between insertion loss of silencers,the one with 30%porosity and 120 Kg/m^(3)rock wool density had the highest insertion loss of 26.2 dBA.Dissipative silencers noticeably reduced centrifugal fan noise exposures.Increasing sound absorbent density and duct porosity up to a certain limit could probably be effective in noise reduction of dissipative silencers.
基金supported in part by the National Natural Science Foundation of China(62001356)in part by the National Natural Science Foundation for Distinguished Young Scholar(61825104)+1 种基金in part by the National Key Research and Development Program of China(2022YFC3301300)in part by the Innovative Research Groups of the National Natural Science Foundation of China(62121001)。
文摘Weak signal reception is a very important and challenging problem for communication systems especially in the presence of non-Gaussian noise,and in which case the performance of optimal linear correlated receiver degrades dramatically.Aiming at this,a novel uncorrelated reception scheme based on adaptive bistable stochastic resonance(ABSR)for a weak signal in additive Laplacian noise is investigated.By analyzing the key issue that the quantitative cooperative resonance matching relationship between the characteristics of the noisy signal and the nonlinear bistable system,an analytical expression of the bistable system parameters is derived.On this basis,by means of bistable system parameters self-adaptive adjustment,the counterintuitive stochastic resonance(SR)phenomenon can be easily generated at which the random noise is changed into a benefit to assist signal transmission.Finally,it is demonstrated that approximately 8dB bit error ratio(BER)performance improvement for the ABSR-based uncorrelated receiver when compared with the traditional uncorrelated receiver at low signal to noise ratio(SNR)conditions varying from-30dB to-5dB.
文摘This paper outlines a plan for the effective reduction of the audible sound level produced by aerodynamic noise from the power-generating turbine blades. The contribution of aerodynamic noise can be divided into two categories: inflow turbulence and airfoil self-noise. The base model and retrofit blade designs were modeled in SolidWorks. Subsequently, noise prediction simulations were conducted and compared to the base blade model to determine which modification provided the greatest benefit using SolidWorks Flow Simulation. The result of this project is a series of blade retrofit recommendations that produce a more acoustically efficient design and reduce noise complaints while enabling turbines to be placed in locations that require quieter operations.
基金supported by National Natural Science Foundation of China(12372049)Science and Technology Program of China National Accreditation Service for Confor-mity Assessment(2022CNAS15)+1 种基金Sichuan Science and Technology Program(2023JDRC0062)Independent Project of State Key Laboratory of Rail Transit Vehicle System(2023TPL-T06).
文摘Reducing the aerodynamic drag and noise levels of high-speed pantographs is important for promoting environmentally friendly,energy efficient and rapid advances in train technology.Using computational fluid dynamics theory and the K-FWH acoustic equation,a numerical simulation is conducted to investigate the aerodynamic characteristics of high-speed pantographs.A component optimization method is proposed as a possible solution to the problemof aerodynamic drag and noise in high-speed pantographs.The results of the study indicate that the panhead,base and insulator are the main contributors to aerodynamic drag and noise in high-speed pantographs.Therefore,a gradual optimization process is implemented to improve the most significant components that cause aerodynamic drag and noise.By optimizing the cross-sectional shape of the strips and insulators,the drag and noise caused by airflow separation and vortex shedding can be reduced.The aerodynamic drag of insulator with circular cross section and strips with rectangular cross section is the largest.Ellipsifying insulators and optimizing the chamfer angle and height of the windward surface of the strips can improve the aerodynamic performance of the pantograph.In addition,the streamlined fairing attached to the base can eliminate the complex flow and shield the radiated noise.In contrast to the original pantograph design,the improved pantograph shows a 21.1%reduction in aerodynamic drag and a 1.65 dBA reduction in aerodynamic noise.
基金supported in part by the National Natural Science Foundation of China Project under Grant 62075147the Suzhou Industry Technological Innovation Projects under Grant SYG202348.
文摘Orthogonal frequency division multiplexing passive optical network(OFDM-PON) has superior anti-dispersion property to operate in the C-band of fiber for increased optical power budget. However,the downlink broadcast exposes the physical layer vulnerable to the threat of illegal eavesdropping. Quantum noise stream cipher(QNSC) is a classic physical layer encryption method and well compatible with the OFDM-PON. Meanwhile, it is indispensable to exploit forward error correction(FEC) to control errors in data transmission. However, when QNSC and FEC are jointly coded, the redundant information becomes heavier and thus the code rate of the transmitted signal will be largely reduced. In this work, we propose a physical layer encryption scheme based on polar-code-assisted QNSC. In order to improve the code rate and security of the transmitted signal, we exploit chaotic sequences to yield the redundant bits and utilize the redundant information of the polar code to generate the higher-order encrypted signal in the QNSC scheme with the operation of the interleaver.We experimentally demonstrate the encrypted 16/64-QAM, 16/256-QAM, 16/1024-QAM, 16/4096-QAM QNSC signals transmitted over 30-km standard single mode fiber. For the transmitted 16/4096-QAM QNSC signal, compared with the conventional QNSC method, the proposed method increases the code rate from 0.1 to 0.32 with enhanced security.
基金Beijing Key Specialized Department for Major Epidemic Prevention and Control (Construction Project)National Major Science and Technology Projects (2017ZX10305501)Beijing Social Science Foundation Planning Project (17SRC019)。
文摘With the rapid development of emergency medicine,emergency physicians are working around the clock,[1]including additional workloads due to sudden public health emergencies and disasters.Occupational risks for emergency physicians are significantly high due to an increasing number of patients with acute and severe diseases,an increased workload.
基金supported by the Key R&D Program of Shandong Province(2021CXGC010210).
文摘Global energy and environmental issues are becoming increasingly problematic,and the vibration and noise problem of 110 kV transformers,which are the most widely distributed,have attracted widespread attention from both inside and outside the industry.DC bias is one of the main contributing factors to vibration noise during the normal operation of transformers.To clarify the vibration and noise mechanism of a 110 kV transformer under a DC bias,a multi-field coupling model of a 110 kV transformer was established using the finite element method.The electromagnetic,vibration,and noise characteristics during the DC bias process were compared and quantified through field circuit coupling in parallel with the power frequency of AC,harmonic,and DC power sources.It was found that a DC bias can cause significant distortions in the magnetic flux density,force,and displacement distributions of the core and winding.The contributions of the DC bias effect to the core and winding are different at Kdc=0.85.At this point,the core approached saturation,and the increase in the core force and displacement slowed.However,the saturation of the core increased the leakage flux,and the stress and displacement of the winding increased faster.The sound field distribution characteristics of the 110 kV transformer under a DC bias are related to the force characteristics.When the DC bias coefficient was 1.25,the noise sound pressure level reached 73.6 dB.
文摘Background: Occupational dermatitis is considered as the second most common occupational disease. It accounts for 25% of all lost workdays. Several international studies reported a prevalence of occupational dermatitis in healthcare workers between 17% and 55%. This study aims to identify factors that affect the professional outcome of nurses suffering from occupational dermatitis. Methods: This was a multicenter cross-sectional study concerning nurses declared having occupational dermatitis in the central region of Tunisia. A synoptic sheet related to socio-professional and administrative data was completed. A self-administered Questionnaire going over medical and occupational characteristics was completed during a direct interview. Results: The study involved forty nurses working in four public hospitals in the center of Tunisia. Only 37 workers were included in the study. A professional reclassification was introduced among 19 workers (51% of study population). Work-station adaptation was requested in 14 cases (38%). Exposure to allergens in the workplace was eliminated in 20 cases. Two study participants were transferred to other departments (5.4%) and three people retired (8.1%). A statistically significant association was found between professional reclassification and a history of allergic manifestations (p = 0.003). Similarly, a significant association was found between professional reclassification and the allergic agent (p = 0.014). Workstation layout was significantly associated with a history of allergic manifestations (p = 0.039), the palm hand location (p = 0.04), professional eviction (p Conclusion: This study identified the main factors influencing the occupational outcome of nurses suffering from occupational dermatitis. This outcome depended on a history of atopy (especially allergic rhinitis) and sensitization to allergens (thiuram mix).
基金the National Natural Science Foundation of China(Grant No.62273033).
文摘This paper presents a comprehensive framework for analyzing phase transitions in collective models such as theVicsek model under various noise types. The Vicsek model, focusing on understanding the collective behaviors of socialanimals, is known due to its discontinuous phase transitions under vector noise. However, its behavior under scalar noiseremains less conclusive. Renowned for its efficacy in the analysis of complex systems under both equilibrium and nonequilibriumstates, the eigen microstate method is employed here for a quantitative examination of the phase transitions inthe Vicsek model under both vector and scalar noises. The study finds that the Vicsek model exhibits discontinuous phasetransitions regardless of noise type. Furthermore, the dichotomy method is utilized to identify the critical points for thesephase transitions. A significant finding is the observed increase in the critical point for discontinuous phase transitions withescalation of population density.
基金the National Natural Science Foundation of China(32201338)Science Technology Program from the Forestry Administration of Guangdong Province(2021KJCX017)+1 种基金Guangzhou Municipal Science and Technology Bureau Program(2023A04J0086)Shenzhen Key Laboratory of Southern Subtropical Plant Diversity。
文摘As a crucial component of terrestrial ecosystems,urban forests play a pivotal role in protecting urban biodiversity by providing suitable habitats for acoustic spaces.Previous studies note that vegetation structure is a key factor influencing bird sounds in urban forests;hence,adjusting the frequency composition may be a strategy for birds to avoid anthropogenic noise to mask their songs.However,it is unknown whether the response mechanisms of bird vocalizations to vegetation structure remain consistent despite being impacted by anthropogenic noise.It was hypothesized that anthropogenic noise in urban forests occupies the low-frequency space of bird songs,leading to a possible reshaping of the acoustic niches of forests,and the vegetation structure of urban forests is the critical factor that shapes the acoustic space for bird vocalization.Passive acoustic monitoring in various urban forests was used to monitor natural and anthropogenic noises,and sounds were classified into three acoustic scenes(bird sounds,human sounds,and bird-human sounds)to determine interconnections between bird sounds,anthropogenic noise,and vegetation structure.Anthropogenic noise altered the acoustic niche of urban forests by intruding into the low-frequency space used by birds,and vegetation structures related to volume(trunk volume and branch volume)and density(number of branches and leaf area index)significantly impact the diversity of bird sounds.Our findings indicate that the response to low and high frequency signals to vegetation structure is distinct.By clarifying this relationship,our results contribute to understanding of how vegetation structure influences bird sounds in urban forests impacted by anthropogenic noise.