Longitudinal joint construction quality is critical to the life of flexible pavements.Maintaining deteriorated longitudinal joints has become a challenge for many highway agencies.Improving the joint's quality thr...Longitudinal joint construction quality is critical to the life of flexible pavements.Maintaining deteriorated longitudinal joints has become a challenge for many highway agencies.Improving the joint's quality through better compaction during construction can help achieve flexible pavements with longer service lives and less maintenance.Current quality control(QC)and quality assurance(QA)plans provide limited coverage.Consequently,the risk of missing areas with poor joint compaction is significant.A density profiling system(DPS)is a non-destructive alternative to conventional destructive evaluation methods.It can provide quick and continuous real-time coverage of the compaction during construction in dielectrics.The paper presents several case studies comparing various types of longitudinal joints and demonstrating the use of DPS to evaluate the joint's compaction quality.The paper shows that dielectric measurements can provide valuable insight into the ability of various construction techniques to achieve adequate levels of compaction at the longitudinal joint.The paper proposes a dielectric-based longitudinal joint quality index(LJQI)to evaluate the relative compaction of the joint during construction.It also shows that adopting DPS for assessing the compaction of longitudinal joints can minimize the risk of agencies accepting poorly constructed joints,identify locations of poor quality during construction,and achieve better-performing flexible pavements.展开更多
This article takes the actual construction project of a certain concrete bridge project as an example to analyze the application of acoustic non-destructive testing technology in its detection.It includes an overview ...This article takes the actual construction project of a certain concrete bridge project as an example to analyze the application of acoustic non-destructive testing technology in its detection.It includes an overview of a certain bridge construction project studied and acoustic non-destructive testing technology and the application of acoustic non-destructive testing technology in actual testing.This analysis hopes to provide some guidelines for acoustic non-destructive testing of modern concrete bridge projects.展开更多
Non-destructive tests have been increasingly used in historic buildings not only for pre-restoration investigation but also as useful tools to evaluate the effectiveness of eventual interventions.These tests can compl...Non-destructive tests have been increasingly used in historic buildings not only for pre-restoration investigation but also as useful tools to evaluate the effectiveness of eventual interventions.These tests can complement and supplement destructive tests like laboratory analysis of extracted samples as long as a sound sampling plan has been put in place to commensurate with the pattern and extent of dilapidation and materials distribution.Common methods employed in projects in Singapore and Malaysia include the infrared thermography,ground penetrating radar,microwave moisture tomography and ultrasonic pulse echo tomography.The paper discusses about a selection of case studies,demonstrating the application of various techniques for the identification of hidden details,defects and deterioration,and moisture detection.展开更多
In situ inflow and outflow permeability tests with the BAT probe at SarapuíII soft clay test site are presented.A description of the BAT permeability test is provided,discussing its advantages and shortcomings,es...In situ inflow and outflow permeability tests with the BAT probe at SarapuíII soft clay test site are presented.A description of the BAT permeability test is provided,discussing its advantages and shortcomings,especially in the case of very soft clays under low stresses.Pore pressures were monitored during probe installation and were found to be slightly lower than piezocone u2 pore pressures,consistent with the position of the filter.The role of filter tip saturation was investigated after the usual saturation procedure provided an unsatisfactory pore pressure response during probe installation.Results show that the vacuum saturation procedure provides adequate response during installation and increases the reliability of the coefficient of permeability determination in early measurements.Both inflow and outflow tests yielded similar results,indicating that careful execution of the test can lead to good test repeatability regardless of the loading condition.Various sequences of alternated inflow and outflow tests have yielded similar results,indicating that soil reconsolidation and filter clogging were negligible in the tests performed.Data are presented concerning the relationship between index parameters and the in situ coefficient of permeability for SarapuíII clay,which plot outside the range of existing databases.展开更多
Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult p...Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult patients with suspected scrub typhus who visited a tertiary care hospital in the Republic of Korea from September to December from 2019 to 2021.The included patients had an acute fever and at least one of the following ten secondary findings:myalgia,skin rash,eschar,headache,thrombocytopenia,increased liver enzyme levels,lymphadenopathy,hepatomegaly,splenomegaly,and pleural effusion.The diagnoses were grouped as scrub typhus or other diseases by two infectious disease physicians.Results:Among 136 patients who met the eligibility criteria,109 had scrub typhus and 27 had different diseases.Single and paired total antibodies using immunofluorescence assay(IFA),and total antibodies using immunochromatography-based rapid diagnostic testing(ICT)were measured in 98%,22%,and 75%of all patients,respectively.Confirmation using paired samples for scrub typhus was established at a median of 11[interquartile range(IQR)10-16]days following the first visit.Among the 82 admitted patients,the median admission time was 9(IQR 7-13)days.According to IFA,58(55%)patients with scrub typhus had total immunoglobulin titers≥1:320,while 23(85%)patients with other disease had titers<1:320.Positive ICT results were observed in 64(74%)patients with scrub typhus and 10(67%)patients with other diseases showed negative ICT results.Conclusions:Serological testing for scrub typhus is currently insufficient for decision-making in clinical practice.展开更多
The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction ...The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction fuse actuator.The impact point easily deviates from the target,and thus the correction result cannot be readily evaluated.However,the cost of shooting tests is considerably high to conduct many tests for data collection.To address this issue,this study proposes an aiming method for shooting tests based on small sample size.The proposed method uses the Bootstrap method to expand the test data;repeatedly iterates and corrects the position of the simulated theoretical impact points through an improved compatibility test method;and dynamically adjusts the weight of the prior distribution of simulation results based on Kullback-Leibler divergence,which to some extent avoids the real data being"submerged"by the simulation data and achieves the fusion Bayesian estimation of the dispersion center.The experimental results show that when the simulation accuracy is sufficiently high,the proposed method yields a smaller mean-square deviation in estimating the dispersion center and higher shooting accuracy than those of the three comparison methods,which is more conducive to reflecting the effect of the control algorithm and facilitating test personnel to iterate their proposed structures and algorithms.;in addition,this study provides a knowledge base for further comprehensive studies in the future.展开更多
Basic magnesium sulfate cement coral aggregate concrete(MCAC)is a new type of concrete consisting of basic magnesium sulfate cement,coarse coral aggregate,coral reef sand and seawater.The rebound hammer(RH),the ultras...Basic magnesium sulfate cement coral aggregate concrete(MCAC)is a new type of concrete consisting of basic magnesium sulfate cement,coarse coral aggregate,coral reef sand and seawater.The rebound hammer(RH),the ultrasonic pulse velocity(UPV)and the compressive strength(fcu)tests of 14 sets of cube specimens of the MCAC after 28 d of aging were conducted.The impact of the content and length of sisal fiber on the relationship between the fcu-RH and the fcu-UPV was determined.A mathematical model was established to predict the strength of the MCAC using the UPV,RH,and comprehensive UPV/RH methods and to obtain the curves of test strength.The applicability of the test strength curves of ordinary portland concrete(OPC),light-weight aggregate concrete(LAC),and coral aggregate concrete(CAC)to MCAC was assessed.The results showed that the test strength curves of OPC,LAC and CAC were inappropriate to determine the strength of MCAC using non-destructive method.The relative standard error of the curves of test strength of the RH method and the comprehensive method met the specifications,whereas that of the UPV method did not.展开更多
This paper explores the performances of a finite element simulation including four concrete models applied to a full-scale reinforced concrete beam subjected to blast loading. Field test data has been used to compare ...This paper explores the performances of a finite element simulation including four concrete models applied to a full-scale reinforced concrete beam subjected to blast loading. Field test data has been used to compare model results for each case. The numerical modelling has been, carried out using the suitable code LS-DYNA. This code integrates blast load routine(CONWEP) for the explosive description and four different material models for the concrete including: Karagozian & Case Concrete, Winfrith, Continuous Surface Cap Model and Riedel-Hiermaier-Thoma models, with concrete meshing based on 10, 15, and 20 mm. Six full-scale beams were tested: four of them used for the initial calibration of the numerical model and two more tests at lower scaled distances. For calibration, field data obtained employing pressure and accelerometers transducers were compared with the results derived from the numerical simulation. Damage surfaces and the shape of rupture in the beams have been used as references for comparison. Influence of the meshing on accelerations has been put in evidence and for some models the shape and size of the damage in the beams produced maximum differences around 15%. In all cases, the variations between material and mesh models are shown and discussed.展开更多
BACKGROUND A reliable test is essential for diagnosing Helicobacter pylori(H.pylori)infection,and crucial for managing H.pylori-related diseases.Serving as an excellent method for detecting H.pylori infection,histolog...BACKGROUND A reliable test is essential for diagnosing Helicobacter pylori(H.pylori)infection,and crucial for managing H.pylori-related diseases.Serving as an excellent method for detecting H.pylori infection,histologic examination is a test that clinicians heavily rely on,especially when complemented with immunohistochemistry(IHC).Additionally,other diagnostic tests for H.pylori,such as the rapid urease test(CLO test)and stool antigen test(SA),are also highly sensitive and specific.Typically,the results of histology and other tests align with each other.However,on rare occasions,discrepancy between histopathology and other H.pylori diagnostic tests occurs.AIM To investigate the discordance between histology and other H.pylori tests,the underlying causes,and the impact on clinical management.METHODS Pathology reports of gastric biopsies were retrieved spanning August 2013 and July 2018.Reports were included in the study only if there were other H.pylori tests within seven days of the biopsy.These additional tests include CLO test,SA,and H.pylori culture.Concordance between histopathology and other tests was determined based on the consistency of results.In instances where histology results were negative while other tests were positive,the slides were retrieved for re-assessment,and the clinical chart was reviewed.RESULTS Of 1396 pathology reports were identified,each accompanied by one additional H.pylori test.The concordance rates in detecting H.pylori infection between biopsy and other tests did not exhibit significant differences based on the number of biopsy fragments.117 discrepant cases were identified.Only 20 cases(9 with CLO test and 11 with SA)had negative biopsy but positive results in other tests.Four cases initially stained with Warthin-Starry turned out to be positive for H.pylori with subsequent IHC staining.Among the remaining 16 true discrepant cases,10 patients were on proton pump inhibitors before the biopsy and/or other tests.Most patients underwent treatment,except for two who were untreated,and two patients who were lost to follow-up.CONCLUSION There are rare discrepant cases with negative biopsy but positive in SA or CLO test.Various factors may contribute to this inconsistency.Most patients in such cases had undergone treatment.展开更多
To investigate the influence of structural parameters on the performances and internal flow characteristics of partial flow pumps at a low specific speed of 10000 rpm,special attention was paid to the first and second...To investigate the influence of structural parameters on the performances and internal flow characteristics of partial flow pumps at a low specific speed of 10000 rpm,special attention was paid to the first and second stage impeller guide vanes.Moreover,the impeller blade outlet width,impeller inlet diameter,blade inclination angle,and number of blades were considered for orthogonal tests.Accordingly,nine groups of design solutions were formed,and then used as a basis for the execution of numerical simulations(CFD)aimed at obtaining the efficiency values and heads for each design solution group.The influence of impeller geometric parameters on the efficiency and head was explored,and the“weight”of each factor was obtained via a range analysis.Optimal structural parameters were finally chosen on the basis of the numerical simulation results,and the performances of the optimized model were verified accordingly(yet by means of CFD).Evidence is provided that the increase in the efficiency and head of the optimized model was 12.11%and 23.5 m,respectively,compared with those of the original model.展开更多
The Sichuan-Tibet transportation corridor is prone to numerous active faults and frequent strong earthquakes.While extensive studies have individually explored the effect of active faults and strong earthquakes on dif...The Sichuan-Tibet transportation corridor is prone to numerous active faults and frequent strong earthquakes.While extensive studies have individually explored the effect of active faults and strong earthquakes on different engineering structures,their combined effect remains unclear.This research employed multiple physical model tests to investigate the dynamic response of various engineering structures,including tunnels,bridges,and embankments,under the simultaneous influence of cumulative earthquakes and stick-slip misalignment of an active fault.The prototype selected for this study was the Kanding No.2 tunnel,which crosses the Yunongxi fault zone within the Sichuan-Tibet transportation corridor.The results demonstrated that the tunnel,bridge,and embankment exhibited amplification in response to the input seismic wave,with the amplification effect gradually decreasing as the input peak ground acceleration(PGA)increased.The PGAs of different engineering structures were weakened by the fault rupture zone.Nevertheless,the misalignment of the active fault may decrease the overall stiffness of the engineering structure,leading to more severe damage,with a small contribution from seismic vibration.Additionally,the seismic vibration effect might be enlarged with the height of the engineering structure,and the tunnel is supposed to have a smaller PGA and lower dynamic earth pressure compared to bridges and embankments in strong earthquake zones crossing active faults.The findings contribute valuable insights for evaluating the dynamic response of various engineering structures crossing an active fault and provide an experimental reference for secure engineering design in the challenging conditions of the Sichuan-Tibet transportation corridor.展开更多
Heavy metal pollution is a negative effect generated in the process of utilizing non-ferrous mineral. Studies about heavy metal migration detection are very important. A new method for rapid detection of heavy metal m...Heavy metal pollution is a negative effect generated in the process of utilizing non-ferrous mineral. Studies about heavy metal migration detection are very important. A new method for rapid detection of heavy metal migration based on ground penetrating radar (GPR) was provided. Comparative tests were studied from field to lab with GPR and X-ray fluorescence analysis (XRF). A tailings reservoir in the Xiangjiang River basin at Hunan Province was taken as experimental site. The downward transfer rule of heavy metal migration was confirmed through tests on systematically arranged survey lines and sampling points in tailings site. Results showed: 1) Through GPR image recognition, tailings reservoir had 3 layers. Reclaimed soil layer (the first layer) and tailings layer (the second layer) had a clear interface. However, tailings layer (the second layer) and subsoil layer (the third layer) had an obscure interface on radar images. It was concluded that heavy metal component had migrated downwards. 2) Chemical component analysis verified image recognition conclusions. Concentrations of As, Cd and Pb were significantly out of limit, while concentration of Cr was under limit according to analysis results on samples from different depths. 3) Pollution degree was evaluated. Downward migration was the main form of heavy metal migration in tailings site, upward migration occurred through adsorption at the same time.展开更多
This study aimed to examine the performance of the Siegel-Tukey and Savage tests on data sets with heterogeneous variances. The analysis, considering Normal, Platykurtic, and Skewed distributions and a standard deviat...This study aimed to examine the performance of the Siegel-Tukey and Savage tests on data sets with heterogeneous variances. The analysis, considering Normal, Platykurtic, and Skewed distributions and a standard deviation ratio of 1, was conducted for both small and large sample sizes. For small sample sizes, two main categories were established: equal and different sample sizes. Analyses were performed using Monte Carlo simulations with 20,000 repetitions for each scenario, and the simulations were evaluated using SAS software. For small sample sizes, the I. type error rate of the Siegel-Tukey test generally ranged from 0.045 to 0.055, while the I. type error rate of the Savage test was observed to range from 0.016 to 0.041. Similar trends were observed for Platykurtic and Skewed distributions. In scenarios with different sample sizes, the Savage test generally exhibited lower I. type error rates. For large sample sizes, two main categories were established: equal and different sample sizes. For large sample sizes, the I. type error rate of the Siegel-Tukey test ranged from 0.047 to 0.052, while the I. type error rate of the Savage test ranged from 0.043 to 0.051. In cases of equal sample sizes, both tests generally had lower error rates, with the Savage test providing more consistent results for large sample sizes. In conclusion, it was determined that the Savage test provides lower I. type error rates for small sample sizes and that both tests have similar error rates for large sample sizes. These findings suggest that the Savage test could be a more reliable option when analyzing variance differences.展开更多
The hydraulic testing of pre-existing fractures(HTPF)is one of the most promising in situ stress measurement methods,particularly for three-dimensional stress tensor determination.However,the stress tensor determinati...The hydraulic testing of pre-existing fractures(HTPF)is one of the most promising in situ stress measurement methods,particularly for three-dimensional stress tensor determination.However,the stress tensor determination based on the HTPF method requires at least six tests or a minimum of 14-15 tests(under different conditions)for reliable results.In this study,we modified the HTPF method by considering the shear stress on each pre-existing fracture,which increased the number of equations for the stress tensor determination and decreased the number of tests required.Different shear stresses were attributed to different fractures by random sampling;therefore,the stress tensors were obtained by searching for the optimal solution using the least squares criterion based on the Monte Carlo method.Thereafter,we constrained the stress tensor based on the tensile strength criterion,compressive strength criterion,and vertical stress constraints.The inverted stress tensors were presented and analyzed based on the tensorial nature of the stress using the Euclidean mean stress tensor.Two stress-measurement campaigns in Weifang(Shandong Province,China)and Mercantour road tunnel(France)were implemented to highlight the validity and efficiency of the modified HTPF(M-HTPF)method.The results showed that the M-HTPF method can be applied for stress tensor inversion using only three to four tests on pre-existing fractures,neglecting the stress gradient.The inversion results were confined to relatively small distribution dispersions and were significantly reliable and stable due to the shear stresses on the fractures and the stress constraints employed.The M-HTPF method is highly feasible and efficient for complete stress tensor determination in a single borehole.展开更多
Aviation turbine engine oils require excellent thermal-oxidative stability because of their high-temperature environments.High-temperature bearing deposit testing is a mandatory method for measuring the thermal-oxidat...Aviation turbine engine oils require excellent thermal-oxidative stability because of their high-temperature environments.High-temperature bearing deposit testing is a mandatory method for measuring the thermal-oxidative performance of aviation lubricant oils,and the relevant apparatus was improved in the present study.Two different commercial aviation turbine engine oils were tested,one with standard performance(known as the SL oil)and the other with high thermal stability,and their thermal-oxidative stability characteristics were evaluated.After 100 h of high-temperature bearing testing,the SL oil was analyzed by using various analytical techniques to investigate its thermal-oxidative process in the bearing test,with its thermal-oxidative degradation mechanism also being discussed.The results indicate that the developed high-temperature bearing apparatus easily meets the test requirements of method 3410.1 in standard FED-STD-791D.The viscosity and total acid number(TAN)of the SL oil increased with the bearing test time,and various deposits were produced in the bearing test,with the micro-particles of the carbon deposits being sphere-like,rod-like,and sheet-like in appearance.The antioxidant additives in the oil were consumed very rapidly in the first 30 h of the bearing test,with N-phenyl-1-naphthylamine being consumed faster than dioctyldiphenylamine.Overall,the oil thermal-oxidative process involves very complex physical and chemical mechanisms.展开更多
The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The ma...The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The macro phenomena of the two different foundation models are described and analyzed.The effects of the replacement of EPS composite soil on seismic-induced liquefaction of backfill and the dynamic performance of a caisson structure are evaluated in detail.The results show that the excess pore water pressure generation in the CES is significantly slower than that in the CSS during the shaking.The dynamic earth pressure acting on the caisson has a triangular shape.The response of horizontal acceleration,displacement,settlement,and rotation angle of the caisson in the CES is smaller than that in the CSS,which means the caisson in the CES has a better seismic performance.Furthermore,the out-of-phase phenomenon between dynamic earth thrust and inertial force in the CES is more obvious than that in the CSS,which is beneficial to reduce the lateral force and improve the stability of the caisson structure.展开更多
The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the t...The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels.展开更多
BACKGROUND Premature ovarian insufficiency(POI)is a condition that causes secondary amenorrhea owing to ovarian hypofunction at an early stage.Early follicular depletion results in intractable infertility,thereby cons...BACKGROUND Premature ovarian insufficiency(POI)is a condition that causes secondary amenorrhea owing to ovarian hypofunction at an early stage.Early follicular depletion results in intractable infertility,thereby considerably reducing the quality of life of females.Given the continuum in weakened ovarian function,progressing from incipient ovarian failure(IOF)to transitional ovarian failure and further to POI,it is necessary to develop biomarkers for predicting POI.The oxidative stress states in IOF and POI were comprehensively evaluated via oxidative stress[diacron-reactive oxygen metabolites(d-ROMs)]test and anti-oxidant capacity[biological antioxidant potential(BAP)].METHODS Females presenting with secondary amenorrhea over 4 mo and a follicle stimulating hormone level of>40 mIU/mL were categorized into the POI group.Females presenting with a normal menstrual cycle and a follicle stimulating hormone level of>10.2 mIU/mL were categorized into the IOF group.Healthy females without ovarian hypofunction were categorized into the control group.Among females aged<40 years who visited our hospital from January 2021 to June 2022,we recruited 11 patients into both POI and IOF groups.For the potential antioxidant capacity,the relative oxidative stress index(BAP/d-ROMs×100)was calculated,and the oxidative stress defense system was comprehensively evaluated.RESULTS d-ROMs were significantly higher in the POI and IOF groups than in the control group,(478.2±58.7 U.CARR,434.5±60.6 U.CARR,and 341.1±35.1 U.CARR,respectively)(U.CARR is equivalent to 0.08 mg/dL of hydrogen peroxide).However,no significant difference was found between the POI and IOF groups.Regarding BAP,no significant difference was found between the control,IOF,and POI groups(2078.5±157.4μmol/L,2116.2±240.2μmol/L,and 2029.0±186.4μmol/L,respectively).The oxidative stress index was significantly higher in the POI and IOF groups than in the control group(23.7±3.3,20.7±3.6,and 16.5±2.1,respectively).However,no significant difference was found between the POI and IOF groups.CONCLUSION High levels of oxidative stress suggest that evaluating the oxidative stress state may be a useful indicator for the early detection of POI.展开更多
Little is known about how the assessment modality,i.e.,computer-based(CB)and paper-based(PB)tests,affects language teachers’scorings,perceptions,and preferences and,therefore,the validity and fairness of classroom wr...Little is known about how the assessment modality,i.e.,computer-based(CB)and paper-based(PB)tests,affects language teachers’scorings,perceptions,and preferences and,therefore,the validity and fairness of classroom writing assessments.The present mixed-methods study used Shaw and Weir’s(2007)sociocognitive writing test validation framework to examine the scoring and consequential validity evidence of CB and PB writing tests in EFL classroom assessment in higher education.Original handwritten and word-processed texts of 38 EFL university students were transcribed to their opposite format and assessed by three language lecturers(N=456 texts,152 per teacher)to examine the scoring validity of CB and PB tests.The teachers’perceptions of text quality and preferences for assessment modality accounted for the consequential validity evidence of both tests.Findings revealed that the assessment modality impacted teachers’scorings,perceptions,and preferences.The teachers awarded higher scores to original and transcribed handwritten texts,particularly text organization and language use.The teachers’perceptions of text quality differed from their ratings,and physical,psychological,and experiential characteristics influenced their preferences for assessment modality.The results have implications for the validity and fairness of CB and PB writing tests and teachers’assessment practices.展开更多
Pipeline transport of hydrogen is one of today’s economic and environmental challenges.In order to find safe and reliable application of both existing gas and build new pipelines,it is essential to carry out tests on...Pipeline transport of hydrogen is one of today’s economic and environmental challenges.In order to find safe and reliable application of both existing gas and build new pipelines,it is essential to carry out tests on full-scale pipeline section,including the potentially more dangerous places than the main pipe,the girth welds.For the investigations,pipeline sections of P355NH steel with girth welds were prepared and exposed to pure hydrogen at twice the maximum allowable operating pressure for 41 days.Subsequently,full-scale burst tests were carried out and specimens were cut and prepared from the typical locations of the failed pipeline sections for mechanical,and macro-and microstructural investigations.The results obtained were evaluated and compared with data from previous full-scale tests on pipeline sections without hydrogen exposure.The results showed differences in the behavior of pipeline sections loaded in different ways,with different characteristics of the materials and the welded joints,both in the cases without hydrogen exposure and in the cases exposed to hydrogen.展开更多
文摘Longitudinal joint construction quality is critical to the life of flexible pavements.Maintaining deteriorated longitudinal joints has become a challenge for many highway agencies.Improving the joint's quality through better compaction during construction can help achieve flexible pavements with longer service lives and less maintenance.Current quality control(QC)and quality assurance(QA)plans provide limited coverage.Consequently,the risk of missing areas with poor joint compaction is significant.A density profiling system(DPS)is a non-destructive alternative to conventional destructive evaluation methods.It can provide quick and continuous real-time coverage of the compaction during construction in dielectrics.The paper presents several case studies comparing various types of longitudinal joints and demonstrating the use of DPS to evaluate the joint's compaction quality.The paper shows that dielectric measurements can provide valuable insight into the ability of various construction techniques to achieve adequate levels of compaction at the longitudinal joint.The paper proposes a dielectric-based longitudinal joint quality index(LJQI)to evaluate the relative compaction of the joint during construction.It also shows that adopting DPS for assessing the compaction of longitudinal joints can minimize the risk of agencies accepting poorly constructed joints,identify locations of poor quality during construction,and achieve better-performing flexible pavements.
文摘This article takes the actual construction project of a certain concrete bridge project as an example to analyze the application of acoustic non-destructive testing technology in its detection.It includes an overview of a certain bridge construction project studied and acoustic non-destructive testing technology and the application of acoustic non-destructive testing technology in actual testing.This analysis hopes to provide some guidelines for acoustic non-destructive testing of modern concrete bridge projects.
文摘Non-destructive tests have been increasingly used in historic buildings not only for pre-restoration investigation but also as useful tools to evaluate the effectiveness of eventual interventions.These tests can complement and supplement destructive tests like laboratory analysis of extracted samples as long as a sound sampling plan has been put in place to commensurate with the pattern and extent of dilapidation and materials distribution.Common methods employed in projects in Singapore and Malaysia include the infrared thermography,ground penetrating radar,microwave moisture tomography and ultrasonic pulse echo tomography.The paper discusses about a selection of case studies,demonstrating the application of various techniques for the identification of hidden details,defects and deterioration,and moisture detection.
文摘In situ inflow and outflow permeability tests with the BAT probe at SarapuíII soft clay test site are presented.A description of the BAT permeability test is provided,discussing its advantages and shortcomings,especially in the case of very soft clays under low stresses.Pore pressures were monitored during probe installation and were found to be slightly lower than piezocone u2 pore pressures,consistent with the position of the filter.The role of filter tip saturation was investigated after the usual saturation procedure provided an unsatisfactory pore pressure response during probe installation.Results show that the vacuum saturation procedure provides adequate response during installation and increases the reliability of the coefficient of permeability determination in early measurements.Both inflow and outflow tests yielded similar results,indicating that careful execution of the test can lead to good test repeatability regardless of the loading condition.Various sequences of alternated inflow and outflow tests have yielded similar results,indicating that soil reconsolidation and filter clogging were negligible in the tests performed.Data are presented concerning the relationship between index parameters and the in situ coefficient of permeability for SarapuíII clay,which plot outside the range of existing databases.
基金the Korea Health Technology R&D Project through the Korea Health Industry Development Institute(KHIDI),funded by the Ministry of Health&Welfare,Republic of Korea(grant no.HI22C0306).
文摘Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult patients with suspected scrub typhus who visited a tertiary care hospital in the Republic of Korea from September to December from 2019 to 2021.The included patients had an acute fever and at least one of the following ten secondary findings:myalgia,skin rash,eschar,headache,thrombocytopenia,increased liver enzyme levels,lymphadenopathy,hepatomegaly,splenomegaly,and pleural effusion.The diagnoses were grouped as scrub typhus or other diseases by two infectious disease physicians.Results:Among 136 patients who met the eligibility criteria,109 had scrub typhus and 27 had different diseases.Single and paired total antibodies using immunofluorescence assay(IFA),and total antibodies using immunochromatography-based rapid diagnostic testing(ICT)were measured in 98%,22%,and 75%of all patients,respectively.Confirmation using paired samples for scrub typhus was established at a median of 11[interquartile range(IQR)10-16]days following the first visit.Among the 82 admitted patients,the median admission time was 9(IQR 7-13)days.According to IFA,58(55%)patients with scrub typhus had total immunoglobulin titers≥1:320,while 23(85%)patients with other disease had titers<1:320.Positive ICT results were observed in 64(74%)patients with scrub typhus and 10(67%)patients with other diseases showed negative ICT results.Conclusions:Serological testing for scrub typhus is currently insufficient for decision-making in clinical practice.
基金the National Natural Science Foundation of China(Grant No.61973033)Preliminary Research of Equipment(Grant No.9090102010305)for funding the experiments。
文摘The longitudinal dispersion of the projectile in shooting tests of two-dimensional trajectory corrections fused with fixed canards is extremely large that it sometimes exceeds the correction ability of the correction fuse actuator.The impact point easily deviates from the target,and thus the correction result cannot be readily evaluated.However,the cost of shooting tests is considerably high to conduct many tests for data collection.To address this issue,this study proposes an aiming method for shooting tests based on small sample size.The proposed method uses the Bootstrap method to expand the test data;repeatedly iterates and corrects the position of the simulated theoretical impact points through an improved compatibility test method;and dynamically adjusts the weight of the prior distribution of simulation results based on Kullback-Leibler divergence,which to some extent avoids the real data being"submerged"by the simulation data and achieves the fusion Bayesian estimation of the dispersion center.The experimental results show that when the simulation accuracy is sufficiently high,the proposed method yields a smaller mean-square deviation in estimating the dispersion center and higher shooting accuracy than those of the three comparison methods,which is more conducive to reflecting the effect of the control algorithm and facilitating test personnel to iterate their proposed structures and algorithms.;in addition,this study provides a knowledge base for further comprehensive studies in the future.
基金Funded by National Natural Science Foundation of China(Nos.51878350,11832013,52078250)the Postgraduate Research&Practice Innovation Program of Jiangsu Province(No.KYCX21_0236)。
文摘Basic magnesium sulfate cement coral aggregate concrete(MCAC)is a new type of concrete consisting of basic magnesium sulfate cement,coarse coral aggregate,coral reef sand and seawater.The rebound hammer(RH),the ultrasonic pulse velocity(UPV)and the compressive strength(fcu)tests of 14 sets of cube specimens of the MCAC after 28 d of aging were conducted.The impact of the content and length of sisal fiber on the relationship between the fcu-RH and the fcu-UPV was determined.A mathematical model was established to predict the strength of the MCAC using the UPV,RH,and comprehensive UPV/RH methods and to obtain the curves of test strength.The applicability of the test strength curves of ordinary portland concrete(OPC),light-weight aggregate concrete(LAC),and coral aggregate concrete(CAC)to MCAC was assessed.The results showed that the test strength curves of OPC,LAC and CAC were inappropriate to determine the strength of MCAC using non-destructive method.The relative standard error of the curves of test strength of the RH method and the comprehensive method met the specifications,whereas that of the UPV method did not.
基金This research has been conducted under SEGTRANS project,funded by the Centre for Industrial Technological Development(CDTI,Government of Spain).
文摘This paper explores the performances of a finite element simulation including four concrete models applied to a full-scale reinforced concrete beam subjected to blast loading. Field test data has been used to compare model results for each case. The numerical modelling has been, carried out using the suitable code LS-DYNA. This code integrates blast load routine(CONWEP) for the explosive description and four different material models for the concrete including: Karagozian & Case Concrete, Winfrith, Continuous Surface Cap Model and Riedel-Hiermaier-Thoma models, with concrete meshing based on 10, 15, and 20 mm. Six full-scale beams were tested: four of them used for the initial calibration of the numerical model and two more tests at lower scaled distances. For calibration, field data obtained employing pressure and accelerometers transducers were compared with the results derived from the numerical simulation. Damage surfaces and the shape of rupture in the beams have been used as references for comparison. Influence of the meshing on accelerations has been put in evidence and for some models the shape and size of the damage in the beams produced maximum differences around 15%. In all cases, the variations between material and mesh models are shown and discussed.
文摘BACKGROUND A reliable test is essential for diagnosing Helicobacter pylori(H.pylori)infection,and crucial for managing H.pylori-related diseases.Serving as an excellent method for detecting H.pylori infection,histologic examination is a test that clinicians heavily rely on,especially when complemented with immunohistochemistry(IHC).Additionally,other diagnostic tests for H.pylori,such as the rapid urease test(CLO test)and stool antigen test(SA),are also highly sensitive and specific.Typically,the results of histology and other tests align with each other.However,on rare occasions,discrepancy between histopathology and other H.pylori diagnostic tests occurs.AIM To investigate the discordance between histology and other H.pylori tests,the underlying causes,and the impact on clinical management.METHODS Pathology reports of gastric biopsies were retrieved spanning August 2013 and July 2018.Reports were included in the study only if there were other H.pylori tests within seven days of the biopsy.These additional tests include CLO test,SA,and H.pylori culture.Concordance between histopathology and other tests was determined based on the consistency of results.In instances where histology results were negative while other tests were positive,the slides were retrieved for re-assessment,and the clinical chart was reviewed.RESULTS Of 1396 pathology reports were identified,each accompanied by one additional H.pylori test.The concordance rates in detecting H.pylori infection between biopsy and other tests did not exhibit significant differences based on the number of biopsy fragments.117 discrepant cases were identified.Only 20 cases(9 with CLO test and 11 with SA)had negative biopsy but positive results in other tests.Four cases initially stained with Warthin-Starry turned out to be positive for H.pylori with subsequent IHC staining.Among the remaining 16 true discrepant cases,10 patients were on proton pump inhibitors before the biopsy and/or other tests.Most patients underwent treatment,except for two who were untreated,and two patients who were lost to follow-up.CONCLUSION There are rare discrepant cases with negative biopsy but positive in SA or CLO test.Various factors may contribute to this inconsistency.Most patients in such cases had undergone treatment.
基金National Key R&D Program of China(Grant No.2020YFC1512404).
文摘To investigate the influence of structural parameters on the performances and internal flow characteristics of partial flow pumps at a low specific speed of 10000 rpm,special attention was paid to the first and second stage impeller guide vanes.Moreover,the impeller blade outlet width,impeller inlet diameter,blade inclination angle,and number of blades were considered for orthogonal tests.Accordingly,nine groups of design solutions were formed,and then used as a basis for the execution of numerical simulations(CFD)aimed at obtaining the efficiency values and heads for each design solution group.The influence of impeller geometric parameters on the efficiency and head was explored,and the“weight”of each factor was obtained via a range analysis.Optimal structural parameters were finally chosen on the basis of the numerical simulation results,and the performances of the optimized model were verified accordingly(yet by means of CFD).Evidence is provided that the increase in the efficiency and head of the optimized model was 12.11%and 23.5 m,respectively,compared with those of the original model.
基金supported by the National Natural Science Foundation of China(Grant Nos.41825018,41977248,42207219)the Second Tibetan Plateau Scientific Expedition and Research Program(STEP)(Grant No.2019QZKK0904)。
文摘The Sichuan-Tibet transportation corridor is prone to numerous active faults and frequent strong earthquakes.While extensive studies have individually explored the effect of active faults and strong earthquakes on different engineering structures,their combined effect remains unclear.This research employed multiple physical model tests to investigate the dynamic response of various engineering structures,including tunnels,bridges,and embankments,under the simultaneous influence of cumulative earthquakes and stick-slip misalignment of an active fault.The prototype selected for this study was the Kanding No.2 tunnel,which crosses the Yunongxi fault zone within the Sichuan-Tibet transportation corridor.The results demonstrated that the tunnel,bridge,and embankment exhibited amplification in response to the input seismic wave,with the amplification effect gradually decreasing as the input peak ground acceleration(PGA)increased.The PGAs of different engineering structures were weakened by the fault rupture zone.Nevertheless,the misalignment of the active fault may decrease the overall stiffness of the engineering structure,leading to more severe damage,with a small contribution from seismic vibration.Additionally,the seismic vibration effect might be enlarged with the height of the engineering structure,and the tunnel is supposed to have a smaller PGA and lower dynamic earth pressure compared to bridges and embankments in strong earthquake zones crossing active faults.The findings contribute valuable insights for evaluating the dynamic response of various engineering structures crossing an active fault and provide an experimental reference for secure engineering design in the challenging conditions of the Sichuan-Tibet transportation corridor.
文摘Heavy metal pollution is a negative effect generated in the process of utilizing non-ferrous mineral. Studies about heavy metal migration detection are very important. A new method for rapid detection of heavy metal migration based on ground penetrating radar (GPR) was provided. Comparative tests were studied from field to lab with GPR and X-ray fluorescence analysis (XRF). A tailings reservoir in the Xiangjiang River basin at Hunan Province was taken as experimental site. The downward transfer rule of heavy metal migration was confirmed through tests on systematically arranged survey lines and sampling points in tailings site. Results showed: 1) Through GPR image recognition, tailings reservoir had 3 layers. Reclaimed soil layer (the first layer) and tailings layer (the second layer) had a clear interface. However, tailings layer (the second layer) and subsoil layer (the third layer) had an obscure interface on radar images. It was concluded that heavy metal component had migrated downwards. 2) Chemical component analysis verified image recognition conclusions. Concentrations of As, Cd and Pb were significantly out of limit, while concentration of Cr was under limit according to analysis results on samples from different depths. 3) Pollution degree was evaluated. Downward migration was the main form of heavy metal migration in tailings site, upward migration occurred through adsorption at the same time.
文摘This study aimed to examine the performance of the Siegel-Tukey and Savage tests on data sets with heterogeneous variances. The analysis, considering Normal, Platykurtic, and Skewed distributions and a standard deviation ratio of 1, was conducted for both small and large sample sizes. For small sample sizes, two main categories were established: equal and different sample sizes. Analyses were performed using Monte Carlo simulations with 20,000 repetitions for each scenario, and the simulations were evaluated using SAS software. For small sample sizes, the I. type error rate of the Siegel-Tukey test generally ranged from 0.045 to 0.055, while the I. type error rate of the Savage test was observed to range from 0.016 to 0.041. Similar trends were observed for Platykurtic and Skewed distributions. In scenarios with different sample sizes, the Savage test generally exhibited lower I. type error rates. For large sample sizes, two main categories were established: equal and different sample sizes. For large sample sizes, the I. type error rate of the Siegel-Tukey test ranged from 0.047 to 0.052, while the I. type error rate of the Savage test ranged from 0.043 to 0.051. In cases of equal sample sizes, both tests generally had lower error rates, with the Savage test providing more consistent results for large sample sizes. In conclusion, it was determined that the Savage test provides lower I. type error rates for small sample sizes and that both tests have similar error rates for large sample sizes. These findings suggest that the Savage test could be a more reliable option when analyzing variance differences.
基金supported by the National Natural Science Foundation of China(Grant No.42174118)a research grant(Grant No.ZDJ 2020-7)from the National Institute of Natural Hazards,Ministry of Emergency Management of China.
文摘The hydraulic testing of pre-existing fractures(HTPF)is one of the most promising in situ stress measurement methods,particularly for three-dimensional stress tensor determination.However,the stress tensor determination based on the HTPF method requires at least six tests or a minimum of 14-15 tests(under different conditions)for reliable results.In this study,we modified the HTPF method by considering the shear stress on each pre-existing fracture,which increased the number of equations for the stress tensor determination and decreased the number of tests required.Different shear stresses were attributed to different fractures by random sampling;therefore,the stress tensors were obtained by searching for the optimal solution using the least squares criterion based on the Monte Carlo method.Thereafter,we constrained the stress tensor based on the tensile strength criterion,compressive strength criterion,and vertical stress constraints.The inverted stress tensors were presented and analyzed based on the tensorial nature of the stress using the Euclidean mean stress tensor.Two stress-measurement campaigns in Weifang(Shandong Province,China)and Mercantour road tunnel(France)were implemented to highlight the validity and efficiency of the modified HTPF(M-HTPF)method.The results showed that the M-HTPF method can be applied for stress tensor inversion using only three to four tests on pre-existing fractures,neglecting the stress gradient.The inversion results were confined to relatively small distribution dispersions and were significantly reliable and stable due to the shear stresses on the fractures and the stress constraints employed.The M-HTPF method is highly feasible and efficient for complete stress tensor determination in a single borehole.
基金supported by the National Key Research and Development Program of China(2022YFB3809005)by SINOPEC(120060-6,121027,and 122042).
文摘Aviation turbine engine oils require excellent thermal-oxidative stability because of their high-temperature environments.High-temperature bearing deposit testing is a mandatory method for measuring the thermal-oxidative performance of aviation lubricant oils,and the relevant apparatus was improved in the present study.Two different commercial aviation turbine engine oils were tested,one with standard performance(known as the SL oil)and the other with high thermal stability,and their thermal-oxidative stability characteristics were evaluated.After 100 h of high-temperature bearing testing,the SL oil was analyzed by using various analytical techniques to investigate its thermal-oxidative process in the bearing test,with its thermal-oxidative degradation mechanism also being discussed.The results indicate that the developed high-temperature bearing apparatus easily meets the test requirements of method 3410.1 in standard FED-STD-791D.The viscosity and total acid number(TAN)of the SL oil increased with the bearing test time,and various deposits were produced in the bearing test,with the micro-particles of the carbon deposits being sphere-like,rod-like,and sheet-like in appearance.The antioxidant additives in the oil were consumed very rapidly in the first 30 h of the bearing test,with N-phenyl-1-naphthylamine being consumed faster than dioctyldiphenylamine.Overall,the oil thermal-oxidative process involves very complex physical and chemical mechanisms.
基金National Natural Science Foundation of China under Grant Nos. 52178336 and 52108324Natural Science Research Project of Colleges and Universities in Jiangsu Province of China under Grant No. 18KJA560002+1 种基金the Middle-Aged&Young Science Leaders of Qinglan Project of Universities in Jiangsu Province of ChinaPostgraduate Research&Practice Innovation Program in Jiangsu Province of China under Grant No. KYCX24_1585
文摘The seismic performance of a caisson structure under two types of models with a saturated sandy foundation(CSS)and an expanded polystyrene(EPS)composite soil foundation(CES)are studied using shaking table tests.The macro phenomena of the two different foundation models are described and analyzed.The effects of the replacement of EPS composite soil on seismic-induced liquefaction of backfill and the dynamic performance of a caisson structure are evaluated in detail.The results show that the excess pore water pressure generation in the CES is significantly slower than that in the CSS during the shaking.The dynamic earth pressure acting on the caisson has a triangular shape.The response of horizontal acceleration,displacement,settlement,and rotation angle of the caisson in the CES is smaller than that in the CSS,which means the caisson in the CES has a better seismic performance.Furthermore,the out-of-phase phenomenon between dynamic earth thrust and inertial force in the CES is more obvious than that in the CSS,which is beneficial to reduce the lateral force and improve the stability of the caisson structure.
基金National Natural Science Foundation of China,Grant/Award Numbers:72091512,52104198,52374210。
文摘The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels.
文摘BACKGROUND Premature ovarian insufficiency(POI)is a condition that causes secondary amenorrhea owing to ovarian hypofunction at an early stage.Early follicular depletion results in intractable infertility,thereby considerably reducing the quality of life of females.Given the continuum in weakened ovarian function,progressing from incipient ovarian failure(IOF)to transitional ovarian failure and further to POI,it is necessary to develop biomarkers for predicting POI.The oxidative stress states in IOF and POI were comprehensively evaluated via oxidative stress[diacron-reactive oxygen metabolites(d-ROMs)]test and anti-oxidant capacity[biological antioxidant potential(BAP)].METHODS Females presenting with secondary amenorrhea over 4 mo and a follicle stimulating hormone level of>40 mIU/mL were categorized into the POI group.Females presenting with a normal menstrual cycle and a follicle stimulating hormone level of>10.2 mIU/mL were categorized into the IOF group.Healthy females without ovarian hypofunction were categorized into the control group.Among females aged<40 years who visited our hospital from January 2021 to June 2022,we recruited 11 patients into both POI and IOF groups.For the potential antioxidant capacity,the relative oxidative stress index(BAP/d-ROMs×100)was calculated,and the oxidative stress defense system was comprehensively evaluated.RESULTS d-ROMs were significantly higher in the POI and IOF groups than in the control group,(478.2±58.7 U.CARR,434.5±60.6 U.CARR,and 341.1±35.1 U.CARR,respectively)(U.CARR is equivalent to 0.08 mg/dL of hydrogen peroxide).However,no significant difference was found between the POI and IOF groups.Regarding BAP,no significant difference was found between the control,IOF,and POI groups(2078.5±157.4μmol/L,2116.2±240.2μmol/L,and 2029.0±186.4μmol/L,respectively).The oxidative stress index was significantly higher in the POI and IOF groups than in the control group(23.7±3.3,20.7±3.6,and 16.5±2.1,respectively).However,no significant difference was found between the POI and IOF groups.CONCLUSION High levels of oxidative stress suggest that evaluating the oxidative stress state may be a useful indicator for the early detection of POI.
文摘Little is known about how the assessment modality,i.e.,computer-based(CB)and paper-based(PB)tests,affects language teachers’scorings,perceptions,and preferences and,therefore,the validity and fairness of classroom writing assessments.The present mixed-methods study used Shaw and Weir’s(2007)sociocognitive writing test validation framework to examine the scoring and consequential validity evidence of CB and PB writing tests in EFL classroom assessment in higher education.Original handwritten and word-processed texts of 38 EFL university students were transcribed to their opposite format and assessed by three language lecturers(N=456 texts,152 per teacher)to examine the scoring validity of CB and PB tests.The teachers’perceptions of text quality and preferences for assessment modality accounted for the consequential validity evidence of both tests.Findings revealed that the assessment modality impacted teachers’scorings,perceptions,and preferences.The teachers awarded higher scores to original and transcribed handwritten texts,particularly text organization and language use.The teachers’perceptions of text quality differed from their ratings,and physical,psychological,and experiential characteristics influenced their preferences for assessment modality.The results have implications for the validity and fairness of CB and PB writing tests and teachers’assessment practices.
基金supported by the European Union and the Hungarian State,co-financed by the European Structural and Investment Funds in the framework of the GINOP-2.3.4-15-2016-00004 project。
文摘Pipeline transport of hydrogen is one of today’s economic and environmental challenges.In order to find safe and reliable application of both existing gas and build new pipelines,it is essential to carry out tests on full-scale pipeline section,including the potentially more dangerous places than the main pipe,the girth welds.For the investigations,pipeline sections of P355NH steel with girth welds were prepared and exposed to pure hydrogen at twice the maximum allowable operating pressure for 41 days.Subsequently,full-scale burst tests were carried out and specimens were cut and prepared from the typical locations of the failed pipeline sections for mechanical,and macro-and microstructural investigations.The results obtained were evaluated and compared with data from previous full-scale tests on pipeline sections without hydrogen exposure.The results showed differences in the behavior of pipeline sections loaded in different ways,with different characteristics of the materials and the welded joints,both in the cases without hydrogen exposure and in the cases exposed to hydrogen.