BACKGROUND Cardiac arrest(CA)induced by electric shock is a rare occurrence,particularly in cases of prolonged CA.Currently,there is limited literature on similar incidents,and we present a relevant case report.CASE S...BACKGROUND Cardiac arrest(CA)induced by electric shock is a rare occurrence,particularly in cases of prolonged CA.Currently,there is limited literature on similar incidents,and we present a relevant case report.CASE SUMMARY A 27-year-old Asian male man,experiencing respiratory CA due to electric shock,was successfully restored to sinus rhythm after 50 min of cardiopulmonary resuscitation and 8 electrical defibrillation sessions.In the subsequent stages,the patient received multiple organ function protection measures,leading to a successful recovery and eventual discharge from the hospital.CONCLUSION Prolonging resuscitation time can enhance the chances of survival for patients,this study provide valuable insights into the management of electric shock-induced CA.展开更多
The twin-tube shock absorber was studied and the relevant factors of thermal equilibrium were simulated. The dynamic model of the shock absorber was constructed and simulation curves of force-displacement and force-ve...The twin-tube shock absorber was studied and the relevant factors of thermal equilibrium were simulated. The dynamic model of the shock absorber was constructed and simulation curves of force-displacement and force-velocity were output. The experiment of the twin-tube shock absorber was carried out, and the results were compared with the modeling resultss. Further, the vibration energy regeneration model was established, and the bench simulation study was carried out. The re- sults showed that the energy regeneration model not only absorbed shock energy but also converted vibration energy into electricity energy.展开更多
Filth adhering to metal pipes can be cleaned by shock wave generated by electrical discharge under water. The mechanism of shock wave effect of electrical discharge under water on filth cleaning is analyzed by buildin...Filth adhering to metal pipes can be cleaned by shock wave generated by electrical discharge under water. The mechanism of shock wave effect of electrical discharge under water on filth cleaning is analyzed by building a mechanical model. A metal pipe coated with cement to simulate real filth is cleaned by using electrical discharge under water. The experimental results confirm the mechanical analysis and also show the technology of electrical discharge under water is an very effective method for filth cleaning.展开更多
This article focuses on the aggression of lightning overload on the equipment of the electrical network of sites where storm activity is very dense;and the electrocution of people located in the direct environment of ...This article focuses on the aggression of lightning overload on the equipment of the electrical network of sites where storm activity is very dense;and the electrocution of people located in the direct environment of the high-voltage substation during the flow of lightning current to the ground through the ground socket. The modeling of the flow circuit of the shock wave consisting of guard wire, lightning arrester and ground socket couple to the transformer of the high voltage substations, thanks to the approach of a servo block, led to the synthesis of a PID regulator (corrector) whose action is to reject the effects of the overvoltage on the network equipment and to significantly reduce or even cancel the effects of the step or touch voltage due to the distribution of the potential around the ground socket;and thus improve the quality of service of the high-voltage transmission and distribution electricity network, especially in stormy times.展开更多
Dear Editor,We present a case of 'Rhegmatogenous retinal detachment following electrical shock injury' for evaluation for publication in your journal. To our knowledge,this is the first case of retinal tears a...Dear Editor,We present a case of 'Rhegmatogenous retinal detachment following electrical shock injury' for evaluation for publication in your journal. To our knowledge,this is the first case of retinal tears and retinal detachment caused by an electrical shock reported in the literature. That展开更多
According to the composition and the principle of the liquid-electric energy-sensing damper, the corresponding hydraulic regenerative model is designed. In this paper, an advanced type of shock absorber combined with ...According to the composition and the principle of the liquid-electric energy-sensing damper, the corresponding hydraulic regenerative model is designed. In this paper, an advanced type of shock absorber combined with the mechanical and electromagnetic hydraulic structure has been proposed that recycles the energy dissipated by shock absorber in the driving process. In addition, the damping characteristics of the conventional mechanical vehicle and the advanced hydraulic regenerative mechanical vehicle have?been analyzed by using AMESim simulation. The regenerative suspension is reformed from the traditional hydraulic and pneumatic suspension. The suspension absorbs kinetic energy converts it into hydraulic potential and pneumatic power to be stored in the accumulator. The kinetic energy is then converted into electricity instead of heat by using the hydraulic suspension and Power-Generating Shock Absorber (PGSA). The AMESim simulation results have efficiently verified the displacement characteristics curves and flow rate of hydraulic fluid in the body. Finally the conversion of energy produced by advanced hydraulic regenerative mechanical vehicle transferred into electrical energy. The designed hydraulic shock absorber allows a significant fuel saving of 1.5% to 4% depending on the vehicle and driving conditions.展开更多
This report was aimed to record the value of dynamic change of cardiac biomarkers in diagnosis of serious myocardial injury in electrical shock. One female patient was admitted to the emergency department, Cho Ray-Phn...This report was aimed to record the value of dynamic change of cardiac biomarkers in diagnosis of serious myocardial injury in electrical shock. One female patient was admitted to the emergency department, Cho Ray-Phnom Penh Hospital, Phnom Penh, Cambodia after electrical accident, in cardiopulmonary arrest status with no pulse, no breath. The cardiopulmonary resuscitation was done immediately as intra-tracheal ventilation, fluid replacement with NaCl 0.9%, urine alkalinization therapy with Natribicarbonate 4.2%, sympathomimetic agents as adrenaline and nor-adrenaline, and IV nutrition with glucose 30%. Cardiac biomarkers were repeated many times over 12 hours after admission. Troponin I increased 1000 times higher from 0.02 ng/mL on admission to 20.1 ng/mL within 12 hours. CK-MB increased from 55.4 to 227 U/L after 2 hours (normal value: <16 U/L). CPK (normal value: 90 - 140 U/L) changed quickly from 99 U/L on admission to a very high level as 9681 U/L after 12 hrs. The CK-MB/CPK index (defined as CK-MB × 100/CPK, unit as %) changed from 55.9% to 2.7%, respectively by time. In conclusion, the very quick dynamic change of cardiac biomarkers suggested the presence of serious myocardial injury among multiple organs injured in electric shock.展开更多
This work deals with an experimental study of a Cu planar wire array(PWA)in air and water under the stored energy 300-1200 J.A single Cu wire is adopted as a controlled trial.Four configurations of PWA and a wire with...This work deals with an experimental study of a Cu planar wire array(PWA)in air and water under the stored energy 300-1200 J.A single Cu wire is adopted as a controlled trial.Four configurations of PWA and a wire with the same mass(cross-section area)but the different specific surface areas(15-223 cm^(2)g^(-1))are exploded.The transient process is analyzed using high-speed photography in combination with the results of optical emission and discharge.Discharge characteristics revealed that PWA always has a higher electric power peak,early but higher voltage peak,as well as faster vaporization and ionization process than the single-wire case.Two to three times stronger optical emission could be obtained when replacing the single-wire with PWA,indicating a higher energy-density state is reached.Phenomenologically,in both air and water,single-wire load tends to develop a transverse stratified structure,while PWA is dominated by the uneven energy deposition among wires.Finally,the synchronism and uniformity of the PWA explosion are discussed.展开更多
This contribution shows an analysis of vibration measurement on large floor-mounted traction batteries of Battery Electric Vehicles(BEV).The focus lies on the requirements for a realistic replication of the mechanical...This contribution shows an analysis of vibration measurement on large floor-mounted traction batteries of Battery Electric Vehicles(BEV).The focus lies on the requirements for a realistic replication of the mechanical environments in a testing laboratory.Especially the analysis on global bending transfer functions and local corner bending coherence indicate that neither a fully stiff fixation of the battery nor a completely independent movement on the four corners yields a realistic and conservative test scenario.The contribution will further show what implication these findings have on future vibration&shock testing equipment for large traction batteries.Additionally,it will cover an outlook on how vibration behavior of highly integrated approaches(cell2car)changes the mechanical loads on the cells.展开更多
文摘BACKGROUND Cardiac arrest(CA)induced by electric shock is a rare occurrence,particularly in cases of prolonged CA.Currently,there is limited literature on similar incidents,and we present a relevant case report.CASE SUMMARY A 27-year-old Asian male man,experiencing respiratory CA due to electric shock,was successfully restored to sinus rhythm after 50 min of cardiopulmonary resuscitation and 8 electrical defibrillation sessions.In the subsequent stages,the patient received multiple organ function protection measures,leading to a successful recovery and eventual discharge from the hospital.CONCLUSION Prolonging resuscitation time can enhance the chances of survival for patients,this study provide valuable insights into the management of electric shock-induced CA.
基金Supported by the National High Technology Research and Development Program of China(2011AA11A223)
文摘The twin-tube shock absorber was studied and the relevant factors of thermal equilibrium were simulated. The dynamic model of the shock absorber was constructed and simulation curves of force-displacement and force-velocity were output. The experiment of the twin-tube shock absorber was carried out, and the results were compared with the modeling resultss. Further, the vibration energy regeneration model was established, and the bench simulation study was carried out. The re- sults showed that the energy regeneration model not only absorbed shock energy but also converted vibration energy into electricity energy.
文摘Filth adhering to metal pipes can be cleaned by shock wave generated by electrical discharge under water. The mechanism of shock wave effect of electrical discharge under water on filth cleaning is analyzed by building a mechanical model. A metal pipe coated with cement to simulate real filth is cleaned by using electrical discharge under water. The experimental results confirm the mechanical analysis and also show the technology of electrical discharge under water is an very effective method for filth cleaning.
文摘This article focuses on the aggression of lightning overload on the equipment of the electrical network of sites where storm activity is very dense;and the electrocution of people located in the direct environment of the high-voltage substation during the flow of lightning current to the ground through the ground socket. The modeling of the flow circuit of the shock wave consisting of guard wire, lightning arrester and ground socket couple to the transformer of the high voltage substations, thanks to the approach of a servo block, led to the synthesis of a PID regulator (corrector) whose action is to reject the effects of the overvoltage on the network equipment and to significantly reduce or even cancel the effects of the step or touch voltage due to the distribution of the potential around the ground socket;and thus improve the quality of service of the high-voltage transmission and distribution electricity network, especially in stormy times.
文摘Dear Editor,We present a case of 'Rhegmatogenous retinal detachment following electrical shock injury' for evaluation for publication in your journal. To our knowledge,this is the first case of retinal tears and retinal detachment caused by an electrical shock reported in the literature. That
文摘According to the composition and the principle of the liquid-electric energy-sensing damper, the corresponding hydraulic regenerative model is designed. In this paper, an advanced type of shock absorber combined with the mechanical and electromagnetic hydraulic structure has been proposed that recycles the energy dissipated by shock absorber in the driving process. In addition, the damping characteristics of the conventional mechanical vehicle and the advanced hydraulic regenerative mechanical vehicle have?been analyzed by using AMESim simulation. The regenerative suspension is reformed from the traditional hydraulic and pneumatic suspension. The suspension absorbs kinetic energy converts it into hydraulic potential and pneumatic power to be stored in the accumulator. The kinetic energy is then converted into electricity instead of heat by using the hydraulic suspension and Power-Generating Shock Absorber (PGSA). The AMESim simulation results have efficiently verified the displacement characteristics curves and flow rate of hydraulic fluid in the body. Finally the conversion of energy produced by advanced hydraulic regenerative mechanical vehicle transferred into electrical energy. The designed hydraulic shock absorber allows a significant fuel saving of 1.5% to 4% depending on the vehicle and driving conditions.
文摘This report was aimed to record the value of dynamic change of cardiac biomarkers in diagnosis of serious myocardial injury in electrical shock. One female patient was admitted to the emergency department, Cho Ray-Phnom Penh Hospital, Phnom Penh, Cambodia after electrical accident, in cardiopulmonary arrest status with no pulse, no breath. The cardiopulmonary resuscitation was done immediately as intra-tracheal ventilation, fluid replacement with NaCl 0.9%, urine alkalinization therapy with Natribicarbonate 4.2%, sympathomimetic agents as adrenaline and nor-adrenaline, and IV nutrition with glucose 30%. Cardiac biomarkers were repeated many times over 12 hours after admission. Troponin I increased 1000 times higher from 0.02 ng/mL on admission to 20.1 ng/mL within 12 hours. CK-MB increased from 55.4 to 227 U/L after 2 hours (normal value: <16 U/L). CPK (normal value: 90 - 140 U/L) changed quickly from 99 U/L on admission to a very high level as 9681 U/L after 12 hrs. The CK-MB/CPK index (defined as CK-MB × 100/CPK, unit as %) changed from 55.9% to 2.7%, respectively by time. In conclusion, the very quick dynamic change of cardiac biomarkers suggested the presence of serious myocardial injury among multiple organs injured in electric shock.
基金supported in part by National Natural Science Foundation of China(No.51907007)Natural Science Foundation of Beijing(No.3212034)+1 种基金State Key Laboratory of Electrical Insulation and Power Equipment(No.EIPE20204)State Key Laboratory of Advanced Electromagnetic Engineering and Technology(No.AEET 2019KF006)。
文摘This work deals with an experimental study of a Cu planar wire array(PWA)in air and water under the stored energy 300-1200 J.A single Cu wire is adopted as a controlled trial.Four configurations of PWA and a wire with the same mass(cross-section area)but the different specific surface areas(15-223 cm^(2)g^(-1))are exploded.The transient process is analyzed using high-speed photography in combination with the results of optical emission and discharge.Discharge characteristics revealed that PWA always has a higher electric power peak,early but higher voltage peak,as well as faster vaporization and ionization process than the single-wire case.Two to three times stronger optical emission could be obtained when replacing the single-wire with PWA,indicating a higher energy-density state is reached.Phenomenologically,in both air and water,single-wire load tends to develop a transverse stratified structure,while PWA is dominated by the uneven energy deposition among wires.Finally,the synchronism and uniformity of the PWA explosion are discussed.
基金We acknowledge support for the article processing charge by the Open Access Publication Fund of Hamburg University of Applied Sciences.
文摘This contribution shows an analysis of vibration measurement on large floor-mounted traction batteries of Battery Electric Vehicles(BEV).The focus lies on the requirements for a realistic replication of the mechanical environments in a testing laboratory.Especially the analysis on global bending transfer functions and local corner bending coherence indicate that neither a fully stiff fixation of the battery nor a completely independent movement on the four corners yields a realistic and conservative test scenario.The contribution will further show what implication these findings have on future vibration&shock testing equipment for large traction batteries.Additionally,it will cover an outlook on how vibration behavior of highly integrated approaches(cell2car)changes the mechanical loads on the cells.