Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the gallopin...Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the galloping mechanism, this paper proposes an online monitoring system for tracking galloping profile of power transmission lines based on wireless inertial measurement units (WIMUs). The system is composed of three modules: wireless inertial measurement nodes, monitoring base station, and remote monitoring station. After detailing the hardware system, the corresponding software which positions and displays galloping profile of the transmission line in real-time is outlined. The feasibility of the proposed on-line monitoring system is demonstrated through a series of experiments at the State Grid Key Laboratory of Power Overhead Transmission Line Galloping (Zhengzhou, China) by taking into account different vibration patterns.展开更多
Aiming at that the successive test data set of the strapdown inertial measurement unit is always small,a Bayesian method is used to study its statistical characteristics.Its prior and posterior distributions are set u...Aiming at that the successive test data set of the strapdown inertial measurement unit is always small,a Bayesian method is used to study its statistical characteristics.Its prior and posterior distributions are set up by the method and the pretest,sample and population information.Some statistical inferences can be made based on the posterior distribution.It can reduce the statistical analysis error in the case of small sample set.展开更多
Reliable and accurate calibration for camera,inertial measurement unit(IMU)and robot is a critical prerequisite for visual-inertial based robot pose estimation and surrounding environment perception.However,traditiona...Reliable and accurate calibration for camera,inertial measurement unit(IMU)and robot is a critical prerequisite for visual-inertial based robot pose estimation and surrounding environment perception.However,traditional calibrations suffer inaccuracy and inconsistency.To address these problems,this paper proposes a monocular visual-inertial and robotic-arm calibration in a unifying framework.In our method,the spatial relationship is geometrically correlated between the sensing units and robotic arm.The decoupled estimations on rotation and translation could reduce the coupled errors during the optimization.Additionally,the robotic calibration moving trajectory has been designed in a spiral pattern that enables full excitations on 6 DOF motions repeatably and consistently.The calibration has been evaluated on our developed platform.In the experiments,the calibration achieves the accuracy with rotation and translation RMSEs less than 0.7°and 0.01 m,respectively.The comparisons with state-of-the-art results prove our calibration consistency,accuracy and effectiveness.展开更多
The purpose of this paper is to design a DVL-RPM based VKF (Velocity Kalman Filter) design for a performance improvement underwater integrated navigation system. The integrated navigation sensor using DVL (Doppler Vel...The purpose of this paper is to design a DVL-RPM based VKF (Velocity Kalman Filter) design for a performance improvement underwater integrated navigation system. The integrated navigation sensor using DVL (Doppler Velocity Log) is widely used to improve the underwater navigation performance. However, the DVL’s range of measuring varied depending on the characteristics of sensor. So, if the sea gets too deep suddenly, it cannot measure the velocity. To complement such a weak point, the VKF was additionally designed, which was made of DVL, RPM (Revolve Per Minutes) of motor, and ES (Echo Sounder). The proposed approach relies on a VKF, augmented by an altitude from ES based switching architecture to yield robust performance, even when DVL exceeds the measurement range and the measured value is unable to be valid. The proposed approach relies on two parts: 1) indirect feedback navigation Kalman filter design, 2) VKF design. To evaluate the proposed method, we compare the VKF aided navigation system with PINS (Pure Inertial Navigation System) and conventional INS-DVL navigation system through simulation results. Simulations illustrate the effectiveness of the underwater navigation system assisted by the additional DVL-RPM based VKF in underwater environment.展开更多
As low cost and highly portable sensors, inertial measurements units (IMU) have become increas-ingly used in gait analysis, embodying an efficient alternative to motion capture systems. Mean-while, being able to compu...As low cost and highly portable sensors, inertial measurements units (IMU) have become increas-ingly used in gait analysis, embodying an efficient alternative to motion capture systems. Mean-while, being able to compute reliably accurate spatial gait parameters using few sensors remains a relatively complex problematic. Providing a clinical oriented solution, our study presents a gy-rometer and accelerometer based algorithm for stride length estimation. Compared to most of the numerous existing works where only an averaged stride length is computed from several IMU, or where the use of the magnetometer is incompatible with everyday use, our challenge here has been to extract each individual stride length in an easy-to-use algorithm requiring only one inertial sensor attached to the subject shank. Our results were validated on healthy subjects and patients suffering from Parkinson’s disease (PD). Estimated stride lengths were compared to GAITRite? walkway system data: the mean error over all the strides was less than 6% for healthy group and 10.3% for PD group. This method provides a reliable portable solution for monitoring the in-stantaneous stride length and opens the way to promising applications.展开更多
Pavement horizontal curve is designed to serve as a transition between straight segments, and its presence may cause a series of driving-related safety issues to motorists and drivers. As is recognized that traditiona...Pavement horizontal curve is designed to serve as a transition between straight segments, and its presence may cause a series of driving-related safety issues to motorists and drivers. As is recognized that traditional methods for curve geometry investigation are time consuming, labor intensive, and inaccurate, this study attempts to develop a method that can automatically conduct horizontal curve identification and measurement at network level. The digital highway data vehicle (DHDV) was utilized for data collection, in which three Euler angles, driving speed, and acceleration of survey vehicle were measured with an inertial measurement unit (IMU). The 3D profiling data used for cross slope calibration was obtained with PaveVision3D Ultra technology at 1 mm resolution. In this study, the curve identification was based on the variation of heading angle, and the curve radius was calculated with ki- nematic method, geometry method, and lateral acceleration method. In order to verify the accuracy of the three methods, the analysis of variance (ANOVA) test was applied by using the control variable of curve radius measured by field test. Based on the measured curve radius, a curve safety analysis model was used to predict the crash rates and safe driving speeds at horizontal curves. Finally, a case study on 4.35 km road segment demonstrated that the proposed method could efficiently conduct network level analysis.展开更多
Total knee arthroplasty is highly successful,in part due to range of motion(RoM)recovery.This is typically estimated goniometrically/visually by physical therapists(PTs)in the clinic,which is imprecise.Accordingly,a v...Total knee arthroplasty is highly successful,in part due to range of motion(RoM)recovery.This is typically estimated goniometrically/visually by physical therapists(PTs)in the clinic,which is imprecise.Accordingly,a validated inertial measurement unit(IMU)method for capturing knee RoM was deployed assessing postoperative RoM both in and outside of the clinical setting.The study's objectives were to evaluate the feasibility of continuously capturing knee RoM pre-/post-op via IMUs,dividing data into PT/non-PT portions of each day,and comparing PT/non-PT metrics.We hypothesized IMU-based clinical knee RoM would differ from IMU-based knee RoM captured outside clinical settings.10 patients(3 M,69±13 years)completed informed consent documents following ethics board approval.A validated IMU method captured long duration(8–12 h/day,~50 days)knee RoM pre-/post-op.Post-op metrics were subdivided(PT versus non-PT).Clinical RoM and patient reported outcome measures were also captured.Compliance and clinical disruption were evaluated.ANOVA compared post-op PT and non-PT means and change scores.Maximum flexion during PT was less than outside PT.PT stance/swing RoM and activity level were greater than outside PT.No temporal variable differences were found PT versus non-PT.IMU RoM measurements capture richer information than clinical measures.Maximum PT flexion was likely less than non-PT due to the exercises completed(i.e.high passive RoM vs.low RoM gait).PT gait flexion likely exceed non-PT because of‘white coat effects’wherein patients are closely monitored clinically.This implies data captured clinically represents optimum performance whereas data captured non-clinically represents realistic performance.展开更多
针对商用低精度惯性测量单元具有高成本、制造工艺复杂、废弃后污染环境、不能生物降解等缺点,提出一种低成本、可生物降解的木制惯性测量单元。该设计包含平衡振子和非平衡振子单元,分别用于测量3轴加速度和3轴角加速度。采用激光诱导...针对商用低精度惯性测量单元具有高成本、制造工艺复杂、废弃后污染环境、不能生物降解等缺点,提出一种低成本、可生物降解的木制惯性测量单元。该设计包含平衡振子和非平衡振子单元,分别用于测量3轴加速度和3轴角加速度。采用激光诱导石墨烯的工艺在木梁上制备应变传感器阵列,并形成多组惠斯顿电桥测量电路。结果表明:加速度方面,X轴灵敏度为0.006 m V/g,Y轴灵敏度为8.695×10^(-4)m V/g,Z轴灵敏度为0.200 m V/g;角加速度方面,X轴灵敏度为0.285 m V/(rad/s^(2)),绕Y轴旋转的灵敏度为0.305 m V/(rad/s^(2)),绕Z轴旋转的灵敏度为0.765 m V/(rad/s^(2))。与有限单元法仿真结果对比,实验测量误差在10%以内,且具有良好的重复测量精度。该惯性测量单元在木制船舶、木制载具、木制家具等方面具有潜在的应用前景。展开更多
文摘Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the galloping mechanism, this paper proposes an online monitoring system for tracking galloping profile of power transmission lines based on wireless inertial measurement units (WIMUs). The system is composed of three modules: wireless inertial measurement nodes, monitoring base station, and remote monitoring station. After detailing the hardware system, the corresponding software which positions and displays galloping profile of the transmission line in real-time is outlined. The feasibility of the proposed on-line monitoring system is demonstrated through a series of experiments at the State Grid Key Laboratory of Power Overhead Transmission Line Galloping (Zhengzhou, China) by taking into account different vibration patterns.
文摘Aiming at that the successive test data set of the strapdown inertial measurement unit is always small,a Bayesian method is used to study its statistical characteristics.Its prior and posterior distributions are set up by the method and the pretest,sample and population information.Some statistical inferences can be made based on the posterior distribution.It can reduce the statistical analysis error in the case of small sample set.
基金This work was supported by the International Partnership Program of Chinese Academy of Sciences(173321KYSB20180020,173321KYSB20200002)the National Natural Science Foundation of China(61903357,62022088)+3 种基金Liaoning Provincial Natural Science Foundation of China(2020-MS-032,2019-YQ-09,2020JH2/10500002,2021JH6/10500114)LiaoNing Revitalization Talents Program(XLYC1902110)China Postdoctoral Science Foundation(2020M672600)the Swedish Foundation for Strategic Research(APR20-0023).
文摘Reliable and accurate calibration for camera,inertial measurement unit(IMU)and robot is a critical prerequisite for visual-inertial based robot pose estimation and surrounding environment perception.However,traditional calibrations suffer inaccuracy and inconsistency.To address these problems,this paper proposes a monocular visual-inertial and robotic-arm calibration in a unifying framework.In our method,the spatial relationship is geometrically correlated between the sensing units and robotic arm.The decoupled estimations on rotation and translation could reduce the coupled errors during the optimization.Additionally,the robotic calibration moving trajectory has been designed in a spiral pattern that enables full excitations on 6 DOF motions repeatably and consistently.The calibration has been evaluated on our developed platform.In the experiments,the calibration achieves the accuracy with rotation and translation RMSEs less than 0.7°and 0.01 m,respectively.The comparisons with state-of-the-art results prove our calibration consistency,accuracy and effectiveness.
文摘The purpose of this paper is to design a DVL-RPM based VKF (Velocity Kalman Filter) design for a performance improvement underwater integrated navigation system. The integrated navigation sensor using DVL (Doppler Velocity Log) is widely used to improve the underwater navigation performance. However, the DVL’s range of measuring varied depending on the characteristics of sensor. So, if the sea gets too deep suddenly, it cannot measure the velocity. To complement such a weak point, the VKF was additionally designed, which was made of DVL, RPM (Revolve Per Minutes) of motor, and ES (Echo Sounder). The proposed approach relies on a VKF, augmented by an altitude from ES based switching architecture to yield robust performance, even when DVL exceeds the measurement range and the measured value is unable to be valid. The proposed approach relies on two parts: 1) indirect feedback navigation Kalman filter design, 2) VKF design. To evaluate the proposed method, we compare the VKF aided navigation system with PINS (Pure Inertial Navigation System) and conventional INS-DVL navigation system through simulation results. Simulations illustrate the effectiveness of the underwater navigation system assisted by the additional DVL-RPM based VKF in underwater environment.
基金supported by an INRIA internal financial support:ADT SENSBIO and a Montpellier Hospital internal financial support(AOI PARKDEMAR CHU Montpellier).
文摘As low cost and highly portable sensors, inertial measurements units (IMU) have become increas-ingly used in gait analysis, embodying an efficient alternative to motion capture systems. Mean-while, being able to compute reliably accurate spatial gait parameters using few sensors remains a relatively complex problematic. Providing a clinical oriented solution, our study presents a gy-rometer and accelerometer based algorithm for stride length estimation. Compared to most of the numerous existing works where only an averaged stride length is computed from several IMU, or where the use of the magnetometer is incompatible with everyday use, our challenge here has been to extract each individual stride length in an easy-to-use algorithm requiring only one inertial sensor attached to the subject shank. Our results were validated on healthy subjects and patients suffering from Parkinson’s disease (PD). Estimated stride lengths were compared to GAITRite? walkway system data: the mean error over all the strides was less than 6% for healthy group and 10.3% for PD group. This method provides a reliable portable solution for monitoring the in-stantaneous stride length and opens the way to promising applications.
文摘Pavement horizontal curve is designed to serve as a transition between straight segments, and its presence may cause a series of driving-related safety issues to motorists and drivers. As is recognized that traditional methods for curve geometry investigation are time consuming, labor intensive, and inaccurate, this study attempts to develop a method that can automatically conduct horizontal curve identification and measurement at network level. The digital highway data vehicle (DHDV) was utilized for data collection, in which three Euler angles, driving speed, and acceleration of survey vehicle were measured with an inertial measurement unit (IMU). The 3D profiling data used for cross slope calibration was obtained with PaveVision3D Ultra technology at 1 mm resolution. In this study, the curve identification was based on the variation of heading angle, and the curve radius was calculated with ki- nematic method, geometry method, and lateral acceleration method. In order to verify the accuracy of the three methods, the analysis of variance (ANOVA) test was applied by using the control variable of curve radius measured by field test. Based on the measured curve radius, a curve safety analysis model was used to predict the crash rates and safe driving speeds at horizontal curves. Finally, a case study on 4.35 km road segment demonstrated that the proposed method could efficiently conduct network level analysis.
基金This was work supported by the National Center for Advancing Translational Sciences of the National Institutes of Health[UL1TR001086].
文摘Total knee arthroplasty is highly successful,in part due to range of motion(RoM)recovery.This is typically estimated goniometrically/visually by physical therapists(PTs)in the clinic,which is imprecise.Accordingly,a validated inertial measurement unit(IMU)method for capturing knee RoM was deployed assessing postoperative RoM both in and outside of the clinical setting.The study's objectives were to evaluate the feasibility of continuously capturing knee RoM pre-/post-op via IMUs,dividing data into PT/non-PT portions of each day,and comparing PT/non-PT metrics.We hypothesized IMU-based clinical knee RoM would differ from IMU-based knee RoM captured outside clinical settings.10 patients(3 M,69±13 years)completed informed consent documents following ethics board approval.A validated IMU method captured long duration(8–12 h/day,~50 days)knee RoM pre-/post-op.Post-op metrics were subdivided(PT versus non-PT).Clinical RoM and patient reported outcome measures were also captured.Compliance and clinical disruption were evaluated.ANOVA compared post-op PT and non-PT means and change scores.Maximum flexion during PT was less than outside PT.PT stance/swing RoM and activity level were greater than outside PT.No temporal variable differences were found PT versus non-PT.IMU RoM measurements capture richer information than clinical measures.Maximum PT flexion was likely less than non-PT due to the exercises completed(i.e.high passive RoM vs.low RoM gait).PT gait flexion likely exceed non-PT because of‘white coat effects’wherein patients are closely monitored clinically.This implies data captured clinically represents optimum performance whereas data captured non-clinically represents realistic performance.
文摘针对商用低精度惯性测量单元具有高成本、制造工艺复杂、废弃后污染环境、不能生物降解等缺点,提出一种低成本、可生物降解的木制惯性测量单元。该设计包含平衡振子和非平衡振子单元,分别用于测量3轴加速度和3轴角加速度。采用激光诱导石墨烯的工艺在木梁上制备应变传感器阵列,并形成多组惠斯顿电桥测量电路。结果表明:加速度方面,X轴灵敏度为0.006 m V/g,Y轴灵敏度为8.695×10^(-4)m V/g,Z轴灵敏度为0.200 m V/g;角加速度方面,X轴灵敏度为0.285 m V/(rad/s^(2)),绕Y轴旋转的灵敏度为0.305 m V/(rad/s^(2)),绕Z轴旋转的灵敏度为0.765 m V/(rad/s^(2))。与有限单元法仿真结果对比,实验测量误差在10%以内,且具有良好的重复测量精度。该惯性测量单元在木制船舶、木制载具、木制家具等方面具有潜在的应用前景。