期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Leukocyte immunoglobulin-like receptor B2 overexpression as a promising therapeutic target and noninvasive screening biomarker for colorectal cancer 被引量:2
1
作者 Qian-Qian Wang Lei Zhou +3 位作者 Geng Qin Chang Tan Yuan-Chen Zhou Shu-Kun Yao 《World Journal of Gastroenterology》 SCIE CAS 2023年第37期5313-5326,共14页
BACKGROUND Colorectal cancer(CRC)has become the second most deadly malignancy in the world,and the exploration of screening markers and precise therapeutic targets is urgent.Our previous research identified leukocyte ... BACKGROUND Colorectal cancer(CRC)has become the second most deadly malignancy in the world,and the exploration of screening markers and precise therapeutic targets is urgent.Our previous research identified leukocyte immunoglobulin-like receptor B2(LILRB2)protein as a characteristic protein of CRC,but the association between LILRB2 expression and clinicopathological features,the internal mechanism related to CRC progression,and screening diagnostic efficacy are not clear.Therefore,we hypothesized that LILRB2 is significantly highly expressed in CRC tissues,correlated with advanced stage and a poor prognosis,and could be used as a therapeutic target and potential screening biomarker for CRC.AIM To explore whether LILRB2 can be used as a potential therapeutic target and noninvasive screening biomarker for CRC.METHODS Patients who underwent radical surgery for CRC at China-Japan Friendship Hospital between February 2021 and October 2022 were included.Cancer and paracancerous tissues were collected to verify LILRB2 expression,and the association between LILRB2 expression and clinicopathological features was analysed.Serum was collected from CRC patients,adenoma patients and healthy controls during the same period to assess the diagnostic value of LILRB2 as a noninvasive screening biomarker,and its diagnostic value was further compared with that of the traditional markers carcinoembryonic antigen(CEA)and carbohydrate antigen 19-9(CA19-9).RESULTS A total of 58 CRC patients were included,and LILRB2 protein was significantly overexpressed in cancer tissues compared with paracancerous tissues(P<0.001).Angiopoietin-like protein 2(ANGPTL2)protein,as the ligand of LILRB2,was synergistically overexpressed in CRC tissues(P<0.001),and overexpression of LILRB2 and ANGPTL2 protein was significantly correlated with poor to moderate differentiation,vascular involvement,lymph node metastasis,distant metastasis,advanced tumor-node-metastasis stage and a poor prognosis(P<0.05),which suggested that LILRB2 and ANGPTL2 are closely associated with CRC progression.In addition,serum LILRB2 concentrations increased stepwise in healthy individuals,adenoma patients and CRC patients with statistically significant differences.The sensitivity of serum LILRB2 for the diagnosis of CRC was 89.74%,the specificity was 88.89%,the area under the curve was 0.95,and the diagnostic efficacy was better than that of conventional CEA and CA19-9.CONCLUSION LILRB2 protein can be used as a potential novel therapeutic target and noninvasive screening biomarker for CRC,which is beneficial for early screening and precise treatment. 展开更多
关键词 Colorectal cancer Leukocyte immunoglobulin-like receptor B2 Angiopoietin-like protein 2 Therapeutic target noninvasive screening biomarker
下载PDF
Study on a noninvasive method for rapid screening Human Serum albumin injectables by Raman spectroscopy 被引量:2
2
作者 Yu Zhao Nan Ji +7 位作者 Xiuji Li Jifeng Hou Min Li Yongjian Yang Ping Tian Xinmei Sun Xinyue Xiao Lihui Yin 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第1期34-42,共9页
Human serum albumin(HSA)injectable product is a severely afflicted area on drug safety due to its high price and restricted supply.Raman spectroscopy performances high specificity on HSA detection and it is even possi... Human serum albumin(HSA)injectable product is a severely afflicted area on drug safety due to its high price and restricted supply.Raman spectroscopy performances high specificity on HSA detection and it is even possible to determine HSA injectable products noninvasively.In this study,we developed a noninvasive rapid screening method for of HSA injectable products by using portable Raman spectrometer.Qualitative models were established by using principal component analysis combined with classical least squares(PCA-CLS)algorithm,while quanti-tative model was established by using partial least squares(PLS)algorithm.Model transfer in different instruments of both the same and different apparatus modules was further discussed in this paper.A total of 34 HSA injectable samples collected from markets were used for verification.The identification results showed 100%accuracy and the predicted concentrations of those identified as true HSA were consistent with their labeled concentrations.The quantitative results also indicated that model transfer was excellent in the same apparatus modules of Raman spectrometer at all concentration levels,and still good enough in the different apparatus modules although the relative standard deviation(RSD)value showed a little increasing trend at low HSA concentration level.In conclusion,the method was proved to be feasible and efficient for screening HSA injections,especially on its screening speed and the consideration of glass containers.Moreover,with inspiring results on the model transfer,the method could be used as a universal screening mean to different Raman instruments. 展开更多
关键词 Human serum albumin Raman noninvasive rapid screening method principal component analysis combined with classical least squares partial least squares model transfer.
下载PDF
Leukocyte immunoglobulin-like receptor B2:A promising biomarker for colorectal cancer 被引量:1
3
作者 Wen-Zhuo Zhao Hong-Gang Wang Xiao-Zhong Yang 《World Journal of Gastroenterology》 SCIE CAS 2024年第4期421-423,共3页
According to the latest global cancer statistics,colorectal cancer(CRC)has emerged as the third most prevalent malignant tumor across the globe.In recent decades,the medical field has implemented several levels of CRC... According to the latest global cancer statistics,colorectal cancer(CRC)has emerged as the third most prevalent malignant tumor across the globe.In recent decades,the medical field has implemented several levels of CRC screening tests,encompassing fecal tests,endoscopic examinations,radiological examinations and blood tests.Previous studies have shown that leukocyte immunoglobulin-like receptor B2(LILRB2)is involved in inhibiting immune cell function,immune evasion,and promoting tumor progression in acute myeloid leukemia and nonsmall cell lung cancer.However,its interaction with CRC has not been reported yet.Recently,a study published in the World Journal of Gastroenterology revealed that LILRB2 and its ligand,angiopoietin-like protein 2,are markedly overexpressed in CRC.This overexpression is closely linked to tumor progression and is indicative of a poor prognosis.The study highlights the potential of utilizing the concentration of LILRB2 in serum as a promising biomarker for tumors.However,there is still room for discussion regarding the data processing and analysis in this research. 展开更多
关键词 Colorectal cancer Leukocyte immunoglobulin-like receptor B2 Angiopoietinlike protein 2 Therapeutic target noninvasive screening biomarker
下载PDF
CLASSIFICATION OF SKIN AUTOFLUORESCENCE SPECTRUM USING SUPPORT VECTOR MACHINE IN TYPE 2 DIABETES SCREENING 被引量:1
4
作者 YUANZHI ZHANG LING ZHU +4 位作者 YIKUN WANG LONG ZHANG SHANDONG YE YONG LIU GONG ZHANG 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2013年第4期42-48,共7页
Advanced glycation end products(AGEs)are a complex and heterogencous group of compounds that have been implicated in diabetes related complfcations.Sk in autofluorescence was recently introduced as an altemative tool ... Advanced glycation end products(AGEs)are a complex and heterogencous group of compounds that have been implicated in diabetes related complfcations.Sk in autofluorescence was recently introduced as an altemative tool for skin AGEs accumulation assessment in diabetes.Sucossful optical diagnosis of diabetes requires a rapid and accurate classification algorithm.In order to improve the performance of noninvasive and optical diagnosis of type 2 diabetes,support vector machines(SVM)algorithm was implemented for the clasification of skin autofluorescence from diabetics and control subjects.Cross-validation and grid optimization methods were employed to calculate the optimal parameters that ma ximize classification accuracy.Classification model was set up according to the training set and then veri fied by the testing set.The results show that radical basis fiunction is the best choice in the four common kernels in SVM.Moreover,a diagnostic accuracy of 82.61%,a sensitivity of 69.57%,and a specificity of 95.65%for discriminating diabetics from control subjects were achieved using a mixed kemel function,which is based on liner kernel function and radical basis function.In comparison with fasting plasma glucose and HbAue test,the clasifcation method of skin autofuorescence spectrum based on SVM shows great potential in screening of diabetes. 展开更多
关键词 Skin autofuorescence support vector machines algorithm type 2 diabetes noninvasive screening
下载PDF
Clinical application of oral contrast-enhanced ultrasound in evaluating the preoperative T staging of gastric cancer
5
作者 Yu Liang Wan-Yi Jing +6 位作者 Jun Song Qiu-Xin Wei Zhi-Qing Cai Juan Li Ping Wu Dong Wang Yi Ma 《World Journal of Gastroenterology》 SCIE CAS 2024年第41期4439-4448,共10页
BACKGROUND Oral contrast-enhanced ultrasound(OCEUS)is widely used in the noninvasive diagnosis and screening of gastric cancer(GC)in China.AIM To investigate the clinical application of OCEUS in evaluating the preoper... BACKGROUND Oral contrast-enhanced ultrasound(OCEUS)is widely used in the noninvasive diagnosis and screening of gastric cancer(GC)in China.AIM To investigate the clinical application of OCEUS in evaluating the preoperative T staging of gastric cancer.METHODS OCEUS was performed before the operation,and standard ultrasound images were retained.The depth of infiltration of GC(T-stage)was evaluated according to the American Joint Committee on Cancer 8th edition of the tumor-nodemetastasis staging criteria.Finally,with postoperative pathological staging as the gold standard reference,the sensitivity,specificity,negative predictive value,positive predictive value,and diagnostic value of OCEUS T staging were evaluated.RESULTS OCEUS achieved diagnostic accuracy rates of 76.6%(T1a),69.6%(T1b),62.7%(T2),60.8%(T3),88.0%(T4a),and 88.7%(T4b),with an average of 75.5%.Ultrasonic T staging sensitivity exceeded 62%,aside from T1b at 40.3%,while specificity was over 91%,except for T3 with 83.5%.The Youden index was above 60%,with T1b and T2 being exceptions.OCEUS T staging corresponded closely with pathology in T4b(kappa>0.75)and moderately in T1a,T1b,T2,T3,and T4a(kappa 0.40-0.75),registering a concordance rate exceeding 84%.CONCLUSION OCEUS was effective,reliable,and accurate in diagnosing the preoperative T staging of GC.As a noninvasive diagnostic technique,OCEUS merits clinical popularization. 展开更多
关键词 Gastric cancer Oral contrast-enhanced ultrasound Tumor-node-metastasis staging noninvasive diagnosis and screening Clinical value
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部