Due to rapid advancements in power electronics, the utilization of electronically switched loads and nonlinear loads is increasing gradually in the electrical power system. These loads create problems of measuring ins...Due to rapid advancements in power electronics, the utilization of electronically switched loads and nonlinear loads is increasing gradually in the electrical power system. These loads create problems of measuring instruments, when connected to the power distribution systems. In this paper, an experimental investigation has been carried out to analyze the performance of single-phase watt-hour(induction and electronic types) energy meters that are being used in Pakistan. The accuracy of the energy meters has been tested under different household nonlinear loads, at various power factors and also at different supply voltage levels. Power factor and total harmonic distortion(THD) of different household loads are also recorded in the experimental work.A hardware based experimental setup has been designed to perform the experimental work. The experimental results have been compared to Water and Power Development Authority(WAPDA) standards for energy meters.展开更多
In this paper, a set of variational formulas of solving nonlinear instability critical loads are established from the viewpoint of variational principle. The paper shows that it is very convenient to solve nonlinear i...In this paper, a set of variational formulas of solving nonlinear instability critical loads are established from the viewpoint of variational principle. The paper shows that it is very convenient to solve nonlinear instability critical load by using the variational formulas suggested in this paper.展开更多
In this paper,we propose an finite element approach based on classical plate theory to investigate the dynamic stability of a layered composite plate subject to nonlinear aerodynamic load.This study considers the infl...In this paper,we propose an finite element approach based on classical plate theory to investigate the dynamic stability of a layered composite plate subject to nonlinear aerodynamic load.This study considers the influence of temperature,nonlinear geometry,and nonlinear aerodynamic load on composite plate structures simultaneously.Specifically,the present work conduct comparison the results of the critical pressure value between the nonlinear aerodynamic load and the linear aerodynamic load,thereby pointing out some necessary cases which must consider the nonlinearity of aerodynamic load for calculating the aerospace structures.We determine the critical pressure value and vibrational amplitude response of the plate by means of calculation.The outcomes of our calculations can be useful in designing and repairing body shells and wings of aircraft equipment.展开更多
Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast d...Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink.展开更多
The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominat...The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominator.These outliers can result in inaccuracy and unreliability of harmonic source location.To address this issue,this paper proposes an innovative method of equivalent impedance parameter calculation of three-phase symmetrical loads that avoid outliers.The correctness and effectiveness of the proposed method are verified by simulations on Simulink using actual monitoring data.The results show that the proposed method is not only simple and easy to implement but also highly accurate.展开更多
The increasing use of power electronic devices can deteriorate the power quality by introducing voltage and current harmonics.In islanded microgrids,the presence of nonlinear loads can distort the point of common coup...The increasing use of power electronic devices can deteriorate the power quality by introducing voltage and current harmonics.In islanded microgrids,the presence of nonlinear loads can distort the point of common coupling(PCC)voltage,while the dead-time effect can also bring additional circulating current harmonics among parallel inverters.To simultaneously attenuate the PCC voltage harmonics and suppress the dead-time induced circulating current harmonics,this paper proposes a coordinated control strategy for harmonic mitigation of parallel inverters.The proposed control strategy allows inverter impedances to be properly reshaped at selective harmonic frequencies.As a consequence,the PCC voltage harmonics are filtered by the inverter operating in the harmonic compensation mode(HCM),whereas the dead-time induced circulating current harmonics are suppressed by the inverter operating in the harmonic rejection mode(HRM).Experimental results from an islanded microgrid prototype with two parallel inverters are provided to validate the effectiveness of the proposed control strategy.展开更多
It is demonstrated that when tension leg platform (TLP) moves with finite amplitude in waves, the inertia force, the drag force and the buoyancy acting on the platform are nonlinear functions of the response of TLP,...It is demonstrated that when tension leg platform (TLP) moves with finite amplitude in waves, the inertia force, the drag force and the buoyancy acting on the platform are nonlinear functions of the response of TLP, The tensions of the tethers are also nonlinear functions of the displacement of TLP. Then the displacement, the velocity and the acceleration of TLP should be taken into account when loads are calculated. In addition, equations of motions should be set up on the instantaneous position. A theo- retical model for analyzing the nonlinear behavior of a TLP with finite displacement is developed, in which multifold nonlinearities are taken into account, i.e., finite displace- ment, coupling of the six degrees of freedom, instantaneous position, instantaneous wet surface, free surface effects and viscous drag force, Based on the theoretical model, the comprehensive nonlinear differential equations are deduced. Then the nonlinear dynamic analysis of ISSC TLP in regular waves is performed in the time domain. The degenerative linear solution of the proposed nonlinear model is verified with existing published one. Furthermore, numerical results are presented, which illustrate that nonlinearities exert a significant influence on the dynamic responses of the TLP.展开更多
With the rapid development of power electronic technology,many linear single-phase loads in low voltage systems are replaced by those equipped with a single-phase diode rectifier.Therefore,most of single-phase loads b...With the rapid development of power electronic technology,many linear single-phase loads in low voltage systems are replaced by those equipped with a single-phase diode rectifier.Therefore,most of single-phase loads become harmonic producers due to their nonlinear characteristics.The nonlinear loads may have different damping characteristics at harmonic frequencies,which could cause potential power quality problems.This paper studies the harmonic damping characteristics of such nonlinear loads.The harmonic damping index is defined to quantify the damping effect of nonlinear loads of harmonic frequencies by analyzing the harmonic model.Then,the harmonic damping index of different harmonic frequencies is compared through simulations and experiments.The results show that the nonlinear load has a constant damping effect for the fundamental frequency,but a stronger damping for the harmonic frequencies.The harmonic damping of such nonlinear loads varies with the harmonic phase angle of supply voltage,and becomes stronger with the increase of the harmonic order.It implies that this type of nonlinear load may be beneficial to the suppression of harmonic resonance.展开更多
Low-voltage(LV) distribution networks are unbalanced and present loads with nonlinear behavior, which introduce harmonics in the networks. The predictable increase in photovoltaic microgeneration(PV μG) accentuates t...Low-voltage(LV) distribution networks are unbalanced and present loads with nonlinear behavior, which introduce harmonics in the networks. The predictable increase in photovoltaic microgeneration(PV μG) accentuates this unbalanced characteristic, as well as poses new technical problems,namely voltage rise and reverse power flow. To accurately account for the distributed PV and loads in the LV network, unbalanced three-phase power flow algorithms should be utilized,where different approaches may be used to represent lines with various degrees of accuracy. The more accurate algorithm considers the electromagnetic coupling between the line conductors,whereas the simpler algorithm represents each conductor of the line as a single-phase line with pure resistive behavior. This paper aims to analyze the influence of the line model on the load flow in a highly unbalanced LV network with a high penetration of PV production, and considers the impact of the harmonics produced by nonlinear loads. Based on the results obtained,it is possible to identify the most suitable model to be used, depending on the study to be performed. Different scenarios of PV generation and loads are addressed in this paper.展开更多
Among incidents on grids,the sag/swell voltage is considered as the most frequent incident.To solve this problem,custom power devices are used.In particular,the dynamic voltage restorer(DVR)is a modern and efficient c...Among incidents on grids,the sag/swell voltage is considered as the most frequent incident.To solve this problem,custom power devices are used.In particular,the dynamic voltage restorer(DVR)is a modern and efficient customer device.DVRs are used to mitigate voltage sag/swells and harmonics on the load bus,thus protecting the sensitive loads.The DVR is a serial compensator that applies a voltage to the point of common coupling to maintain the voltage of sensitive load at the nominal value.To improve the performance of DVRs,in this study,the control strategy of the two-stage loop circuit is implemented.The external voltage control loop uses a sequence-decoupled resonant(SDR)controller,and the inner current-control loop uses the proportional resonant(PR)controller implemented in the stationary frameαβ.展开更多
文摘Due to rapid advancements in power electronics, the utilization of electronically switched loads and nonlinear loads is increasing gradually in the electrical power system. These loads create problems of measuring instruments, when connected to the power distribution systems. In this paper, an experimental investigation has been carried out to analyze the performance of single-phase watt-hour(induction and electronic types) energy meters that are being used in Pakistan. The accuracy of the energy meters has been tested under different household nonlinear loads, at various power factors and also at different supply voltage levels. Power factor and total harmonic distortion(THD) of different household loads are also recorded in the experimental work.A hardware based experimental setup has been designed to perform the experimental work. The experimental results have been compared to Water and Power Development Authority(WAPDA) standards for energy meters.
文摘In this paper, a set of variational formulas of solving nonlinear instability critical loads are established from the viewpoint of variational principle. The paper shows that it is very convenient to solve nonlinear instability critical load by using the variational formulas suggested in this paper.
文摘In this paper,we propose an finite element approach based on classical plate theory to investigate the dynamic stability of a layered composite plate subject to nonlinear aerodynamic load.This study considers the influence of temperature,nonlinear geometry,and nonlinear aerodynamic load on composite plate structures simultaneously.Specifically,the present work conduct comparison the results of the critical pressure value between the nonlinear aerodynamic load and the linear aerodynamic load,thereby pointing out some necessary cases which must consider the nonlinearity of aerodynamic load for calculating the aerospace structures.We determine the critical pressure value and vibrational amplitude response of the plate by means of calculation.The outcomes of our calculations can be useful in designing and repairing body shells and wings of aircraft equipment.
基金funded by Geran Galakan Penyelidik Muda GGPM-2020-004 Universiti Kebangsaan Malaysia.
文摘Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink.
基金supported by the National Natural Science Foundation of China(No.51777035).
文摘The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominator.These outliers can result in inaccuracy and unreliability of harmonic source location.To address this issue,this paper proposes an innovative method of equivalent impedance parameter calculation of three-phase symmetrical loads that avoid outliers.The correctness and effectiveness of the proposed method are verified by simulations on Simulink using actual monitoring data.The results show that the proposed method is not only simple and easy to implement but also highly accurate.
基金This research was supported by the National Research Foundation,Prime Minister’s Office,Singapore under the Energy Programme and administrated by the Energy Market Authority(EP Award No.NRF2015EWT-EIRP002-007)。
文摘The increasing use of power electronic devices can deteriorate the power quality by introducing voltage and current harmonics.In islanded microgrids,the presence of nonlinear loads can distort the point of common coupling(PCC)voltage,while the dead-time effect can also bring additional circulating current harmonics among parallel inverters.To simultaneously attenuate the PCC voltage harmonics and suppress the dead-time induced circulating current harmonics,this paper proposes a coordinated control strategy for harmonic mitigation of parallel inverters.The proposed control strategy allows inverter impedances to be properly reshaped at selective harmonic frequencies.As a consequence,the PCC voltage harmonics are filtered by the inverter operating in the harmonic compensation mode(HCM),whereas the dead-time induced circulating current harmonics are suppressed by the inverter operating in the harmonic rejection mode(HRM).Experimental results from an islanded microgrid prototype with two parallel inverters are provided to validate the effectiveness of the proposed control strategy.
基金Project supported by "Creativeness Project of the Tenth Five-Year Plan" of Chinese Academy of Sciences (No.KJCX2-SW-L03)the National High-Tech Research and Development Program of China (863 Program) (No.2004AA617010)
文摘It is demonstrated that when tension leg platform (TLP) moves with finite amplitude in waves, the inertia force, the drag force and the buoyancy acting on the platform are nonlinear functions of the response of TLP, The tensions of the tethers are also nonlinear functions of the displacement of TLP. Then the displacement, the velocity and the acceleration of TLP should be taken into account when loads are calculated. In addition, equations of motions should be set up on the instantaneous position. A theo- retical model for analyzing the nonlinear behavior of a TLP with finite displacement is developed, in which multifold nonlinearities are taken into account, i.e., finite displace- ment, coupling of the six degrees of freedom, instantaneous position, instantaneous wet surface, free surface effects and viscous drag force, Based on the theoretical model, the comprehensive nonlinear differential equations are deduced. Then the nonlinear dynamic analysis of ISSC TLP in regular waves is performed in the time domain. The degenerative linear solution of the proposed nonlinear model is verified with existing published one. Furthermore, numerical results are presented, which illustrate that nonlinearities exert a significant influence on the dynamic responses of the TLP.
基金This work was supported by the National Natural Science Foundation of China(No.51777021).
文摘With the rapid development of power electronic technology,many linear single-phase loads in low voltage systems are replaced by those equipped with a single-phase diode rectifier.Therefore,most of single-phase loads become harmonic producers due to their nonlinear characteristics.The nonlinear loads may have different damping characteristics at harmonic frequencies,which could cause potential power quality problems.This paper studies the harmonic damping characteristics of such nonlinear loads.The harmonic damping index is defined to quantify the damping effect of nonlinear loads of harmonic frequencies by analyzing the harmonic model.Then,the harmonic damping index of different harmonic frequencies is compared through simulations and experiments.The results show that the nonlinear load has a constant damping effect for the fundamental frequency,but a stronger damping for the harmonic frequencies.The harmonic damping of such nonlinear loads varies with the harmonic phase angle of supply voltage,and becomes stronger with the increase of the harmonic order.It implies that this type of nonlinear load may be beneficial to the suppression of harmonic resonance.
基金supported by national funds through Funda??o para a Ciência e a Tecnologia (FCT)(No. UIDB/50021/2020)。
文摘Low-voltage(LV) distribution networks are unbalanced and present loads with nonlinear behavior, which introduce harmonics in the networks. The predictable increase in photovoltaic microgeneration(PV μG) accentuates this unbalanced characteristic, as well as poses new technical problems,namely voltage rise and reverse power flow. To accurately account for the distributed PV and loads in the LV network, unbalanced three-phase power flow algorithms should be utilized,where different approaches may be used to represent lines with various degrees of accuracy. The more accurate algorithm considers the electromagnetic coupling between the line conductors,whereas the simpler algorithm represents each conductor of the line as a single-phase line with pure resistive behavior. This paper aims to analyze the influence of the line model on the load flow in a highly unbalanced LV network with a high penetration of PV production, and considers the impact of the harmonics produced by nonlinear loads. Based on the results obtained,it is possible to identify the most suitable model to be used, depending on the study to be performed. Different scenarios of PV generation and loads are addressed in this paper.
文摘Among incidents on grids,the sag/swell voltage is considered as the most frequent incident.To solve this problem,custom power devices are used.In particular,the dynamic voltage restorer(DVR)is a modern and efficient customer device.DVRs are used to mitigate voltage sag/swells and harmonics on the load bus,thus protecting the sensitive loads.The DVR is a serial compensator that applies a voltage to the point of common coupling to maintain the voltage of sensitive load at the nominal value.To improve the performance of DVRs,in this study,the control strategy of the two-stage loop circuit is implemented.The external voltage control loop uses a sequence-decoupled resonant(SDR)controller,and the inner current-control loop uses the proportional resonant(PR)controller implemented in the stationary frameαβ.