Extensive studies based on partition curve of gravity separation have been investigated. All created models are merely used to simulate density distribution at the same size fraction. However, they cannot be used to p...Extensive studies based on partition curve of gravity separation have been investigated. All created models are merely used to simulate density distribution at the same size fraction. However, they cannot be used to predictive distribution of materials depending on compound feature of density and size. According to this situation, an improved model of partition curve based on accumulation normal distribution, which was distinguished from conventional model of accumulation normal distribution for partition curve, was proposed in this paper. It could simulate density distribution at different size fractions by using the density-size compound index and conflating the partition curves at different size fractions as one partition curve. The feasibility of three compound indexes, including mass index, settlement index and transformation index, were investigated. Specific forms of the improved model were also proposed. It is found that transformation index leads to the best fitting results, while the fitting error is only 1.75 according to the fitting partition curve.展开更多
The theory for measuring the time constant of thermocouple was introduced, and the method for measuring the time constant of NANMAC thermocouple by using dynamic calibration system of transient surface temperature sen...The theory for measuring the time constant of thermocouple was introduced, and the method for measuring the time constant of NANMAC thermocouple by using dynamic calibration system of transient surface temperature sensor was proposed. In this system, static and dynamic calibrations were conducted for infrared detectors and thermocouples, and then both temperature-time curves were obtained. Since the frequency response of infrared detector is superior to that of calibrat- ed thermocouple, the values measured by infrared detectors are taken as true values. Through dividing the values measured with thermocouples by those with infrared detectors, a normalized curve was obtained, based on which the time constant of thermocouple was measured. With this method, the experiments were carried out with NANMAC thermocouple to obtain its time constant. The results show that the method for measuring the time constant is feasible and the dynamic calibration of thermocouples can be achieved at microsecond and millisecond level. This research has a certain reference value for research and application of NANMAC thermocouple temperature sensor.展开更多
基金the financial support from the National Natural Science Foundation of China (No. 51221462)
文摘Extensive studies based on partition curve of gravity separation have been investigated. All created models are merely used to simulate density distribution at the same size fraction. However, they cannot be used to predictive distribution of materials depending on compound feature of density and size. According to this situation, an improved model of partition curve based on accumulation normal distribution, which was distinguished from conventional model of accumulation normal distribution for partition curve, was proposed in this paper. It could simulate density distribution at different size fractions by using the density-size compound index and conflating the partition curves at different size fractions as one partition curve. The feasibility of three compound indexes, including mass index, settlement index and transformation index, were investigated. Specific forms of the improved model were also proposed. It is found that transformation index leads to the best fitting results, while the fitting error is only 1.75 according to the fitting partition curve.
文摘The theory for measuring the time constant of thermocouple was introduced, and the method for measuring the time constant of NANMAC thermocouple by using dynamic calibration system of transient surface temperature sensor was proposed. In this system, static and dynamic calibrations were conducted for infrared detectors and thermocouples, and then both temperature-time curves were obtained. Since the frequency response of infrared detector is superior to that of calibrat- ed thermocouple, the values measured by infrared detectors are taken as true values. Through dividing the values measured with thermocouples by those with infrared detectors, a normalized curve was obtained, based on which the time constant of thermocouple was measured. With this method, the experiments were carried out with NANMAC thermocouple to obtain its time constant. The results show that the method for measuring the time constant is feasible and the dynamic calibration of thermocouples can be achieved at microsecond and millisecond level. This research has a certain reference value for research and application of NANMAC thermocouple temperature sensor.