The development of interstate electric ties ISETs and grids(ISGs) is a global process; recently, countries of Northeast Asia(NEA) that were previously very poorly connected have started to study the possibility of con...The development of interstate electric ties ISETs and grids(ISGs) is a global process; recently, countries of Northeast Asia(NEA) that were previously very poorly connected have started to study the possibility of constructing ISETs and ISGs. This paper describes the current state of the interstate transmissions in the NEA region, considering the prospective projects of ISETs in NEA. The results of the system optimization study on prospective NEA ISGs are provided. The proposals on the development of electric power cooperation in NEA are formulated.展开更多
东北与华北联网后东北电网动态特性明显恶化、稳定水平大幅度下降,不同发电机和负荷模型对稳定计算的结果影响很大。虽然采取了计及励磁系统动态行为的详细发电机模型的仿真方法、在东北电网重要发电机组上加装电力系统稳定器(power sys...东北与华北联网后东北电网动态特性明显恶化、稳定水平大幅度下降,不同发电机和负荷模型对稳定计算的结果影响很大。虽然采取了计及励磁系统动态行为的详细发电机模型的仿真方法、在东北电网重要发电机组上加装电力系统稳定器(power system stabilizer,PSS)等措施,但PSS参数整定的合理性及整体匹配效果无法得到有效验证,选择电力系统模型尤其是负荷模型还缺乏足够科学依据,对所选模型与电网运行实际的贴近程度也很难做出准确的定量甚至定性的分析。为此东北电网有限公司提出了大区电网联网模式下东北电网稳定水平研究的工作思路,并于2004年3月25日和2005年3月29日在500kV电压等级运行电网上分别实施了2次人工三相完全金属性接地短路试验。试验达到了预期效果,表明根据大扰动试验的实测数据,进行电网负荷模型的校核和修正,建立适用于我国电网的负荷模型的技术路线和研究方法在工程上是可行的和有效的。展开更多
东北–华北联网后的计算分析表明,选择不同的发电机和负荷模型对稳定计算结果的影响较大,东北电网负荷模型的建模或校核需要以大扰动试验数据为依据,分析了实时动态监测系统(wide area measurement system,WAMS)在东北电网基于大扰动事...东北–华北联网后的计算分析表明,选择不同的发电机和负荷模型对稳定计算结果的影响较大,东北电网负荷模型的建模或校核需要以大扰动试验数据为依据,分析了实时动态监测系统(wide area measurement system,WAMS)在东北电网基于大扰动事件的负荷建模过程中的作用,WAMS是大扰动试验风险可观测、试验出现异常情况可控制的基本保障,为基于大扰动事件负荷建模研究提供了电网动态测试数据,其实测的相量数据同时也是建立仿真计算运行方式的重要数据源。运行经验表明,开展东北电网负荷建模的可持续研究需要基于WAMS的扰动数据收集、处理和分析制度的保障。展开更多
以2004年东北电网冬腰方式为例,对考虑配电网络的综合负荷模型(synthetic load model considering distribution network,SLM)以及各种常用的负荷模型进行了适应性分析。吉黑断面稳定极限和辽吉断面稳定极限的计算结果表明,采用考虑配...以2004年东北电网冬腰方式为例,对考虑配电网络的综合负荷模型(synthetic load model considering distribution network,SLM)以及各种常用的负荷模型进行了适应性分析。吉黑断面稳定极限和辽吉断面稳定极限的计算结果表明,采用考虑配电网络的综合负荷模型与II型马达、40%恒阻抗+60%恒功率的静态负荷模型以及30%恒阻抗+30%恒电流+40%恒功率的静态负荷模型计算结果比较接近。最后对考虑配电网络的综合负荷模型进行了参数灵敏度分析。展开更多
文摘The development of interstate electric ties ISETs and grids(ISGs) is a global process; recently, countries of Northeast Asia(NEA) that were previously very poorly connected have started to study the possibility of constructing ISETs and ISGs. This paper describes the current state of the interstate transmissions in the NEA region, considering the prospective projects of ISETs in NEA. The results of the system optimization study on prospective NEA ISGs are provided. The proposals on the development of electric power cooperation in NEA are formulated.
文摘东北与华北联网后东北电网动态特性明显恶化、稳定水平大幅度下降,不同发电机和负荷模型对稳定计算的结果影响很大。虽然采取了计及励磁系统动态行为的详细发电机模型的仿真方法、在东北电网重要发电机组上加装电力系统稳定器(power system stabilizer,PSS)等措施,但PSS参数整定的合理性及整体匹配效果无法得到有效验证,选择电力系统模型尤其是负荷模型还缺乏足够科学依据,对所选模型与电网运行实际的贴近程度也很难做出准确的定量甚至定性的分析。为此东北电网有限公司提出了大区电网联网模式下东北电网稳定水平研究的工作思路,并于2004年3月25日和2005年3月29日在500kV电压等级运行电网上分别实施了2次人工三相完全金属性接地短路试验。试验达到了预期效果,表明根据大扰动试验的实测数据,进行电网负荷模型的校核和修正,建立适用于我国电网的负荷模型的技术路线和研究方法在工程上是可行的和有效的。
文摘东北–华北联网后的计算分析表明,选择不同的发电机和负荷模型对稳定计算结果的影响较大,东北电网负荷模型的建模或校核需要以大扰动试验数据为依据,分析了实时动态监测系统(wide area measurement system,WAMS)在东北电网基于大扰动事件的负荷建模过程中的作用,WAMS是大扰动试验风险可观测、试验出现异常情况可控制的基本保障,为基于大扰动事件负荷建模研究提供了电网动态测试数据,其实测的相量数据同时也是建立仿真计算运行方式的重要数据源。运行经验表明,开展东北电网负荷建模的可持续研究需要基于WAMS的扰动数据收集、处理和分析制度的保障。
文摘以2004年东北电网冬腰方式为例,对考虑配电网络的综合负荷模型(synthetic load model considering distribution network,SLM)以及各种常用的负荷模型进行了适应性分析。吉黑断面稳定极限和辽吉断面稳定极限的计算结果表明,采用考虑配电网络的综合负荷模型与II型马达、40%恒阻抗+60%恒功率的静态负荷模型以及30%恒阻抗+30%恒电流+40%恒功率的静态负荷模型计算结果比较接近。最后对考虑配电网络的综合负荷模型进行了参数灵敏度分析。