期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol
1
作者 Ezekiel O. Agbalagba Mebougna L. Drabo +5 位作者 Stephen U. Egarievwe Utpal N. Roy Amir H. Davis Mordecai B. Israel Parion L. Alexander Ralph B. James 《Materials Sciences and Applications》 2021年第8期363-373,共11页
Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of gr... Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10<sup>10</sup> Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of <sup>241</sup>Am. 展开更多
关键词 CdZnTeSe Chemical Etching Energy Resolution Gamma-Ray Spectroscopy Infrared Imaging nuclear detectors
下载PDF
Measurement of Radon Gas Concentrations in Tap Water Samples for Thi-Qar Governorate Using Nuclear Track Detector (CR-39)
2
作者 Liath Ahmed Najam Hazim Louis Mansour +1 位作者 Nada Fadhil Tawfiq Mahmood Salim Karim 《Detection》 2016年第1期1-8,共8页
In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (... In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (CR-39). The results of measurements have shown that the highest average radon concentration in water samples is found in AL-Refai region which is equal to (0.223 ± 0.03 Bq/L), while the lowest average radon gas concentration is found in AL-Fajr region which is equal to (0.108 ± 0.01 Bq/L), with an average value of (0.175 ± 0.03 Bq/L). The highest value of annual effective dose (AED) in tap water samples is found in AL-Refai region, which is equal to (0.814 μSv/y), while the lowest value of (AED) is found in AL-Fajr region which is equal to (0.394 μSv/y), with an average value of (0.640 ± 0.1 μSv/y). The present results have shown that radon gas concentrations in tap water samples are less than the recommended international value (11.1 Bq/L). There for tap water in all the studied sites in Thi-Qar governorate is safe as for as radon concentration being concerned. 展开更多
关键词 RADON Solid State nuclear Track detectors CR-39 Radon in Water
下载PDF
Study of CdZnTeSe Gamma-Ray Detector under Various Bias Voltages
3
作者 Mebougna L. Drabo Stephen U. Egarievwe +4 位作者 Utpal N. Roy Benicia A. Harrison Carmella A. Goree Emmanuel K. Savage Ralph B. James 《Materials Sciences and Applications》 2020年第8期553-559,共7页
Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such... Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of <sup>241</sup>Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time. 展开更多
关键词 CdZnTeSe Energy Resolution Energy-Peak Stability Gamma-Ray Spectroscopy nuclear detectors
下载PDF
Measurement of cross sections for charge pickup by 84Kr on Al, C and CH2 targets at 400 MeV/u 被引量:1
4
作者 Rong Li Dong-Hai Zhang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第6期60-66,共7页
The nuclear charge pickup cross sections of 84Kr on CH2,C,and Al targets are investigated using CR-39 nuclear track detector at the highest energy of 395 MeV/u.The cross sections for H are calculated from those measur... The nuclear charge pickup cross sections of 84Kr on CH2,C,and Al targets are investigated using CR-39 nuclear track detector at the highest energy of 395 MeV/u.The cross sections for H are calculated from those measured on C and CH2 targets.The dependence of the charge pickup cross section on target mass is studied. 展开更多
关键词 Charge pickup reaction Cross section CR-39 nuclear track detector
下载PDF
Indoor^(222)Rn Levels and Effective Dose Estimation of Academic Staff in izmir-Turkey
5
作者 TURKAN ALKAN OZLEM KARADENIZ 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第4期259-267,共9页
Objective To investigate the annual effective doses from indoor radon received by academic staff in the Faculty building. Methods Measurements of indoor radon concentrations were performed in the Arts and Sciences Fac... Objective To investigate the annual effective doses from indoor radon received by academic staff in the Faculty building. Methods Measurements of indoor radon concentrations were performed in the Arts and Sciences Faculty of Dokuz Eylul University for two surveys of about 1 month duration respectively using the SSNTD (Solid State Nuclear Track Detectors) method with LR115 detectors. Time integrated measurements comprised different locations inside the faculty building: classrooms, toilets, canteen and offices. Homes of academic staff were also tested for radon. Results The aritthmetic mean radon concentration is 161 Bq m-3 with a range between 40 and 335 Bq m-3 in the Faculty. Six offices and three classrooms have a radon concentration above 200 Bq m-3. The results show that the radon concentration in classrooms is generally higher than in offices. Based on the measured indoor radon data, the annual effective doses received by staff in the Faculty were estimated to range from 0.79 to 4.27 mSv, according to UNSCEAR methodology. The annual effective doses received by staff ranged from 0.78 to 4.20 mSv in homes. On average, the Faculty contributed 56% to the annual effective dose. Conclusion Reported values for radon concentrations and corresponding doses are within the ICRP recommended limits for workplaces. 展开更多
关键词 Indoor radon Solid state nuclear track detectors SCHOOL Annual effective dose
下载PDF
Neutron activation analysis of ceramic tiles and its component and radon exhalation rate
6
作者 A.El-Shershaby A.Sroor +2 位作者 F.Ahmed A.S.Abdel-Haleem Z.Abdel 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第1期94-99,共6页
The concentrations of 20 trace elements in several ceramics tiles and ceramic composites used in Egypt were elementally analyzed by neutron activation analysis(NAA) technique. The samples and standard were irradiate... The concentrations of 20 trace elements in several ceramics tiles and ceramic composites used in Egypt were elementally analyzed by neutron activation analysis(NAA) technique. The samples and standard were irradiated with reactor for 4 h(in the Second Research Egyptian Reactor(Et-RR-2)) with thermal neutron flux 5.9×10 13 n/(cm 2·s).The gamma-ray spectra obtained were measured for several times by means of the hyper pure germanium detection system(HPGe). Also a solid state nuclear track detector(SSNTD) CR-39, was used to measure the emanation rate of radon for these samples. The radium concentrations were found to vary from 0.39—3.59 ppm and the emanation rates were found to vary from (0.728—5.688) × 10 -4 kg/(m 2· s).The elemental analysis of the ceramic tiles and ceramic composites have a great importance in assigning the physical properties and in turn the quality of the material. 展开更多
关键词 CERAMIC neutron activation analysis(NAA) radon emanation solid state nuclear track detector(SSNTD)
下载PDF
Characteristics of Ions Emitted from Laser-Induced Silver Plasma
7
作者 M.S.RAFIQUE M.KHALEEQ-UR-RAHMAN +1 位作者 Shakoor MUNAZZA K.A.BHATTI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第4期450-454,共5页
In this work, study of laser-induced ions is presented. The plasma was produced by focusing a Nd:YAG laser, with a wavelength of 1064 nm, a pulsed width of 9-14 ns, a power of 1.1 MW and energy of 10 mJ, on silver ta... In this work, study of laser-induced ions is presented. The plasma was produced by focusing a Nd:YAG laser, with a wavelength of 1064 nm, a pulsed width of 9-14 ns, a power of 1.1 MW and energy of 10 mJ, on silver target in vacuum (10-3 Torr= 1.3332 Pa). The characteristics of ion streams were investigated by CR-39 detectors located at angles of 0°, 30°, 60° and 90° with respect to normal of the target. The distance between the silver target and each detector was 11 cm. The energy of silver ions was found ranging from 1.5 eV to 1.06E4 eV. There was a high concentration of ions with low energy as compared to those with high energy, showing the energy distribution amongst the ions. The flux of ions was maximum in the axial direction which was decreasing with the angle increase with respect to normal of the target, and finally became minimum in the radial direction. Hence the silver ions have shown anisotropic behaviour. 展开更多
关键词 Nd: YAG laser flux of ions ANISOTROPIC solid state nuclear track detector (SSNTD)
下载PDF
Application of stratified implantation for silicon micro-strip detectors
8
作者 李海霞 李占奎 +9 位作者 王方聪 李荣华 陈翠红 王秀华 戎欣娟 刘凤琼 王柱生 李春艳 祖凯玲 卢子伟 《Chinese Physics C》 SCIE CAS CSCD 2015年第6期85-88,共4页
In the fabrication of a 48 mm×48 mm silicon micro-strip nuclear radiation detector with 96 strips on each side, a perfect P-N junction cannot be formed consistently by the one-step implantation process, and thus ... In the fabrication of a 48 mm×48 mm silicon micro-strip nuclear radiation detector with 96 strips on each side, a perfect P-N junction cannot be formed consistently by the one-step implantation process, and thus over 50% of strips produced do not meet application requirements. However, the method of stratified implantation not only avoids the P region between the surface of wafers and the P+ region, but also overcomes the shadow effect. With the help of the stratified implantation process, a perfect functional P-N junction can be formed, and over 95% of strips meet application requirements. 展开更多
关键词 nuclear radiation detectors stratified implantation P-N junction reverse body resistance
原文传递
Preparation of a silicon micro-strip nuclear radiation detector by a two-step annealing process
9
作者 李海霞 李占奎 +3 位作者 王方聪 王柱生 王秀华 李春艳 《Chinese Physics C》 SCIE CAS CSCD 2011年第7期635-637,共3页
The annealing process for boron implantation is a crucial step during large size nuclear radiation detector fabrication. It can reduce the lattice defects and the projection straggling. A two-step annealing process fo... The annealing process for boron implantation is a crucial step during large size nuclear radiation detector fabrication. It can reduce the lattice defects and the projection straggling. A two-step annealing process for boron implantation was developed instead of a one-step annealing process, and the reverse body resistance of a silicon micro-strip detector was significantly increased, which means that the performance of the detector was improved. 展开更多
关键词 nuclear radiation detector two-step annealing reverse body resistance
原文传递
Research Program of Determination of Geological Age by Thermal Analysis Method 被引量:1
10
作者 杨铜锁 辛督强 +3 位作者 王团部 王登武 史永谦 李义国 《Journal of Earth Science》 SCIE CAS CSCD 2013年第4期657-662,共6页
On the basis of previous research achievements of measuring the solid state nuclear track in apatite by thermal analysis method, the author further proposes the research program to measure the energy deposited by the ... On the basis of previous research achievements of measuring the solid state nuclear track in apatite by thermal analysis method, the author further proposes the research program to measure the energy deposited by the solid state nuclear track contained in zircon, sphene, epidote, apatite and other samples, in order to study the geological age and geothermal history. Compared with the measurement of nuclear track density by etching method, this one does not need to conduct so many processing programs for samples, but can improve the measurement accuracy. 展开更多
关键词 solid state nuclear track detector thermal analysis geological age annealing heat.
原文传递
上一页 1 下一页 到第