期刊文献+
共找到5,084篇文章
< 1 2 250 >
每页显示 20 50 100
添加H_(2)对NH_(3)/空气旋流火焰OH^(*)化学发光的影响
1
作者 陈达南 李军 +4 位作者 李兴 郭怡君 赖诗妮 黄宏宇 小林敬幸 《燃烧科学与技术》 CAS CSCD 北大核心 2024年第5期466-472,共7页
火焰的化学发光特性是了解氨作为无碳替代燃料时的火焰结构和反应机理的基本方法.本研究通过实验获得了不同当量比和H_(2)添加量的NH_(3)/空气旋流火焰中的OH^(*)化学发光分布和形成特征,比较了不同条件下OH^(*)层分布特性及火焰燃烧现... 火焰的化学发光特性是了解氨作为无碳替代燃料时的火焰结构和反应机理的基本方法.本研究通过实验获得了不同当量比和H_(2)添加量的NH_(3)/空气旋流火焰中的OH^(*)化学发光分布和形成特征,比较了不同条件下OH^(*)层分布特性及火焰燃烧现象的影响.结果表明,随着当量比的增加,OH^(*)辐射峰增加,且当量比的增加显著增强了OH^(*)的整体化学发光强度.在贫燃料火焰中,当量比效应大于NH_(3)稀释效应,而在当量和富燃料条件下,这两种效应相当.随着掺氢比例的增加,OH^(*)化学发光强度逐渐增加,OH^(*)峰值位置逐渐从下游火焰向上游移动. 展开更多
关键词 OH^(*)化学发光 氨燃烧 当量比 加氢比例 旋流火焰
下载PDF
Clinical value of chemiluminescence method for detection of antinuclear antibody profiles 被引量:1
2
作者 Hui-Yao Xiang Xi-Ying Xiang +3 位作者 Ting-Bo Ten Xie Ding Yu-Wen Liu Chun-Hua Luo 《World Journal of Clinical Cases》 SCIE 2023年第28期6688-6697,共10页
BACKGROUND Antinuclear antibodies(ANAs)are crucial in diagnosing autoimmune diseases,mainly systemic lupus erythematosus(SLE).This study aimed to compare the performance of chemiluminescence assay(CLIA)and line immuno... BACKGROUND Antinuclear antibodies(ANAs)are crucial in diagnosing autoimmune diseases,mainly systemic lupus erythematosus(SLE).This study aimed to compare the performance of chemiluminescence assay(CLIA)and line immunoassay(LIA)in detecting ANAs in patients with autoimmune diseases,evaluate their diagnostic accuracy for SLE,and develop a novel diagnostic model using CLIA-detected antibodies for SLE.Specimens from patients with autoimmune diseases and physical examination specimens were collected to parallel detect specific antibodies.Individual antibodies'diagnostic performance and a model combining multiple antibodies were assessed.The findings provide valuable insights into improving the diagnosis of SLE through innovative approaches.AIM To compare the performance of CLIA and LIA in detecting ANAs in patients with autoimmune diseases,assess their accuracy for SLE,and develop a novel diagnostic model using CLIA-detected antibodies for SLE.METHODS Specimens have been obtained from 270 patients with clinically diagnosed autoimmune disorders,as well as 130 physical examination specimens.After that,parallel detection of anti-double-stranded DNA(dsDNA)antibody,anti-histone(Histone)antibody,anti-nucleosome(Nuc)antibody,anti-Smith(Sm)antibody,anti-ribosomal P protein(Rib-P)antibody,anti-sicca syndrome A(Ro60)antibody,anti-sicca syndrome A(Ro52)antibody,anti-sicca syndrome(SSB)antibody,anticentromere protein B(Cenp-B)antibody,anti-DNA topoisomerase 1(Scl-70)antibody,anti-histidyl tRNA synthetase(Jo-1)antibody,and anti-mitochondrial M2(AMA-M2)antibody was performed using CLIA and LIA.The detection rates,compliance rates,and diagnostic performance for SLE were compared between the two methodologies,followed by developing a novel diagnostic model for SLE.RESULTS CLIA and LIA exhibited essentially comparable detection rates for anti-dsDNA antibody,anti-Histone antibody,anti-Nuc antibody,anti-Sm antibody,anti-Rib-P antibody,anti-Ro60 antibody,anti-Ro52 antibody,anti-SSB antibody,anti-Cenp-B antibody,anti-DNAScl-70 antibody,anti-Jo-1 antibody and anti-AMA-M2 antibody(P>0.05).The two methods displayed identical results for the detection of anti-dsDNA antibody,anti-Histone antibody,anti-Nuc antibody,anti-Sm antibody,anti-Ro60 antibody,anti-Ro52 antibody,anti-SSB antibody,anti-Cenp-B antibody,anti-Scl-70 antibody,and anti-AMA-M2 antibody(Kappa>0.7,P<0.05),but showed a moderate agreement for the detection of anti-Rib-P antibody and anti-Jo-1 antibody(Kappa=0.671 and 0.665;P<0.05).In addition,the diagnostic performance of these antibodies detected by both methods was similar for SLE.The diagnostic model's area under the curve values,sensitivity,and specificity,including an anti-dsDNA antibody and an anti-Ro60 antibody detected by CLIA,were 0.997,0.962,and 0.978,respectively.These values were higher than the diagnostic performance of individual antibodies.CONCLUSION CLIA and LIA demonstrated excellent overall consistency in detecting ANA profiles.A diagnostic model based on CLIA-detected antibodies can successfully contribute to developing a novel technique for detecting SLE. 展开更多
关键词 chemiluminescence assay Immunoblotting Antinuclear antibody profile Autoimmune diseases Systemic lupus erythematosus Diagnostic model
下载PDF
Determination the Vigor of Rice Seed with Different Degrees of Aging with Ultraweak Chemiluminescence During Early Imbibition 被引量:11
3
作者 陈文利 邢达 何永红 《Acta Botanica Sinica》 CSCD 2002年第11期1376-1379,共4页
用高灵敏度的单光子计数系统探测人工老化 (40℃ ,相对湿度 90 % ) 0、7、14和 2 1d的水稻种子吸胀初期的超弱化学发光强度变化 ,首次观测到水稻 (OryzasativaL .)种子吸胀初期超弱化学发光强度与其老化程度有关。加水激活水稻种子的超... 用高灵敏度的单光子计数系统探测人工老化 (40℃ ,相对湿度 90 % ) 0、7、14和 2 1d的水稻种子吸胀初期的超弱化学发光强度变化 ,首次观测到水稻 (OryzasativaL .)种子吸胀初期超弱化学发光强度与其老化程度有关。加水激活水稻种子的超弱化学发光 ,其强度依赖于种子的老化程度。实验结果表明水稻种子的人工老化时间越短 ,则吸胀初期 (2 0~ 30min)超弱化学发光的强度越强 ,萌发率越高。水稻种子萌发率与超弱化学发光强度呈显著正相关。观测水稻种子吸胀初期超弱化学发光强度的变化可望成为检测种子老化程度的一种快速、简便、无损伤的新方法。 展开更多
关键词 rice seeds ultraweak chemiluminescence early imbibition accelerated aging
下载PDF
Chemiluminescence Determination of Benzoic Acid Using A Solid-Phase Verdigris Reactor 被引量:1
4
作者 王晓妮 张洁 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第3期283-286,共4页
A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that t... A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that the unsaturated complex of Cu(II) and benzoic acid (1:1) has strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The calibration graph is linear over the range of 0.025 ~ 60 g/mL of benzoic acid, with a relative standard deviation of less than 3.0 %, and the detection limit is 0.01礸穖L-1. The proposed method was applied to the determination of benzoic acid content in different pharmaceutical formulations. 展开更多
关键词 Benzoic acid chemiluminescence solid-phase reactor pharmaceutical formulations.
下载PDF
Flow injection chemiluminescence determination of meloxicam using potassium permanganate and formaldehyde system 被引量:1
5
作者 贾宝秀 曹明亮 +3 位作者 刘彩红 李玉琴 李珂 齐永秀 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第1期35-40,共6页
A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium pe... A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium permanganate in a hydrochloric acid medium, enhanced by formaldehyde (HCHO). Under optimum conditions, calibration curve over the range of 1.0-20.0μg/mL was obtained. The proposed method was successfully applied to the determination of meloxicam in capsules with no evi- dence of interference from common excipients. The detection limit of this method was 25.6 ng/mL. The relative standard deviation was 2.1% for 10.0 μg/mL meloxicam. The sample throughput was found to be 120 samples/h. 展开更多
关键词 MELOXICAM Flow injection chemiluminescence FORMALDEHYDE Pharmaceutical analysis
下载PDF
Chemiluminescence detection of permanganate index (COD_(Mn)) by a luminol-KMnO_4 based reaction 被引量:15
6
作者 TIAN Jinjun HU Yonggang ZHANG Jie 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第2期252-256,共5页
A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol... A novel chemiluminescence (CL) system for determination of permanganate index (CODMn) combined with flow injection analysis has been proposed in this study. On the basis of the chemiluminescent reaction of luminol-KMnO4 system, light emission caused by luminol-KMnO4 system was detected by the photomultiplier tube, and its intensity caused by the appearance of KMnO4 after sample digestion was inversely proportional to CODMn. Effects for CODMn determining such as pH, concentrations and interference were investigated in detail. A detection limit of 0.3 mg/L CODMn with a linear range of 0.3-200 mg/L for its theoretical CODMn was obtained under the optimized experimental conditions. The relative standard deviation was 4.3% for 5.0 mg/L CODMn (n = 11). This CL flow system for determining CODMn was simple, rapid, and suitable for automatic analysis. The data obtained by the present method were fairly in good agreement with those obtained by the standard titrimetric method. It has been applied to determine real samples with satisfactory results. 展开更多
关键词 FLOW-INJECTION chemiluminescence permanganate index (CODMn) luminol-KMnO4
下载PDF
Recent advances in electrogenerated chemiluminescence biosensing methods for pharmaceuticals 被引量:8
7
作者 Yu Zhang Rui Zhang +2 位作者 Xiaolin Yang Honglan Qi Chengxiao Zhang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第1期9-19,共11页
Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very power... Electrogenerated chemiluminescence(electrochemiluminescence, ECL) generates species at electrode surfaces, which undergoes electron-transfer reactions and forms excited states to emit light. It has become a very powerful analytical technique and has been widely used in such as clinical testing, biowarfare agent detection, and pharmaceutical analysis. This review focuses on the current trends of molecular recognition-based biosensing methods for pharmaceutical analysis since 2010. It introduces a background of ECL and presents the recent ECL developments in ECL immunoassay(ECLIA), immunosensors, enzyme-based biosensors, aptamer-based biosensors, and molecularly imprinted polymers(MIP)-based sensors. At last, the future perspective for these analytical methods is briefly discussed. 展开更多
关键词 Electrogenerated chemiluminescence PHARMACEUTICAL ANALYSIS IMMUNOASSAY Biosensors
下载PDF
Determination of resveratrol in red wine by solid phase extraction-flow injection chemiluminescence method 被引量:7
8
作者 Juan Juan Ren Hai Yan Liu +2 位作者 Yu Hong Hao Pin Gang He Yu Zhi Fang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第8期985-988,共4页
A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and H... A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C18 solid-phase extraction cartridges). Under the optimum conditions, the proposed method allows the measurement of resveratrol over the range of 1.32 × 10^-8 to 1.32 × 10^-5 mol/L with a detection limit of 3.30 ×10^-9 mol/L, and the relative standard deviation for 1.32 ×10^-5 mol/L resveratrol (n = 11) is 3.8%. This method has been successfully applied for the determination of the resveratrol in red wine. Furthermore, the possible reaction mechanism was also discussed. 展开更多
关键词 RESVERATROL Solid phase extraction How-injection chemiluminescence Potassium permanganate FORMALDEHYDE
下载PDF
Chemiluminescence Determination of Molybdenum by on-Line Reduction with a Flow Injection System 被引量:4
9
作者 Zhi Jia ZHU (Experimental Center, Hebei Normal University, Shijiazhuang 050016) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第5期427-430,共4页
The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination o... The chemiluminescence (CL) reaction between lucigenin (Lu) and molybdenum (III) produced by a Jones reductor was investigated using a flow injection system. On the basis of this, a novel method for the determination of trace amount of molybdenum has been established. The emission intensity was linear with molybdenum concentration in the range of 0.1-1000 ng/mL; the detection limit was 0.02 ng/mL molybdenum; the relative standard deviation was less than 2% for the determination of 0.1 ng/mL molybdenum (n=11). The method has been applied successfully to the analysis of trace molybdenum in water and steel samples. 展开更多
关键词 chemiluminescence analysis reductant FLOW-INJECTION MOLYBDENUM LUCIGENIN
下载PDF
Solid Phase Extraction Chemiluminescence Determination of Methamidaphos on Vegetables 被引量:5
10
作者 LI Xiao-zhou GUAN Ting-ting +2 位作者 ZHOU Chi YIN Ji-qiu ZHANG Yi-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2006年第1期21-24,共4页
The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing e... The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing effect of methamidaphos on the CL reaction of luminol with hydrogen peroxide in an alkaline solution. Under the optimal conditions, the CL intensity is linear to the methamidaphos mass concentration in a range of 0. 2-13μg/mL ( r= 0. 9992). The detection limit(3σ) is 0. 047μg/mL. The relative standard deviations for the analysis of three samples are 1.8%, 2.5% and 3.7% ( n = 5 ), respectively. The recovery is in a range of 90%-109% by the method. In this work, this method was successfully applied to the determination of the methamidaphos residue on some vegetable samples. 展开更多
关键词 chemiluminescence Flow injection Solid phase extraction Methamidaphos
下载PDF
Simultaneous determination of captopril and hydrochlorothiazide by time-resolved chemiluminescence with artificial neural network calibration 被引量:5
11
作者 Han-Chun Yao Min Sun +2 位作者 Xiao-Feng Yang Zhen-Zhong Zhang Hua Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期32-38,共7页
The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CP... The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation. 展开更多
关键词 time-resolved chemiluminescence artificial neural network CAPTOPRIL HYDROCHLOROTHIAZIDE
下载PDF
Highly sensitive chemiluminescence technology for protein detection using aptamer-based rolling circle amplification platform 被引量:3
12
作者 Zhi-Juan Cao Qian-Wen Peng Xue Qiu Cai-Yun Liu Jian-Zhong Lu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第3期159-165,共7页
A robust, selective and highly sensitive chemiluminescent (CL) platform for protein assay was presented in this paper. This novel CL approach utilized rolling circle amplification (RCA) as a signal enhancement tec... A robust, selective and highly sensitive chemiluminescent (CL) platform for protein assay was presented in this paper. This novel CL approach utilized rolling circle amplification (RCA) as a signal enhancement technique and the 96-well plate as the immobilization and separation carrier. Typically, the antibody immobilized on the surface of 96-well plate was sandwiched with the protein target and the aptamer-primer sequence. This aptamer-primer sequence was then employed as the primer of RCA. Based on this design, a number of the biotinylated probes and streptavidin-horseradish peroxidase (SA-HRP) were captured on the plate, and the CL signal was amplified. In summary, our results demonstrated a robust biosensor with a detection limit of 10 fM that is easy to be established and utilized, and devoid of light source. Therefore, this new technique .will broaden the perspective for future development of DNA-based biosensors for the detection of other protein biomarkers related to clinical diseases, by taking advantages of high sensitivity and selectivity. 展开更多
关键词 PROTEIN APTAMER chemiluminescence Rolling circleamplification
下载PDF
Diagnosis of Toxoplasma gondii infection in pregnant women using automated chemiluminescence and quantitative real time PCR 被引量:3
13
作者 Ehsan Ahmadpour Elmira Zargami +9 位作者 Mahmoud Mahami-Oskouei Adel Spotin Abbas Shahbazi Hossein Samadi Kafil Saba Rajabi Paria Alizadeh Yagoob Azadi Reza Bahaj Firouz Shahrivar Aleksandra Barac 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2019年第1期26-31,共6页
Objective: To identify serodiagnosis and quantification of Toxoplasma gondii(T. gondii) infection among pregnant women in Salmas, northwest of Iran. Methods: In this crosssectional study, 276 blood samples were collec... Objective: To identify serodiagnosis and quantification of Toxoplasma gondii(T. gondii) infection among pregnant women in Salmas, northwest of Iran. Methods: In this crosssectional study, 276 blood samples were collected from pregnant women referred to the health care centers in Salmas city. The demographic variables were also recorded. Titers of antiToxoplasma IgM and IgG antibodies(Ab) were determined using the chemiluminescence immunoassay. Quantitative real-time PCR targeting the T. gondii repeated element gene was also performed on the blood sample. Results: Out of all, 19.92%(55/276) and 2.17%(6/276) patients were seropositive for anti-Toxoplasma IgG and IgM Ab, respectively. Moreover, the presence of T. gondii DNA was observed in 12.31%(34/276) blood samples. A significant relationship was observed between the IgG Ab seropositivity and contact with the cat as a risk factor(P=0.022). Conclusions: The seroprevalence rate of T. gondii infection in pregnant women is relatively low. Consequently, the seronegative pregnant women are at risk, and a considerable rate of positive blood samples for the presence of parasite's DNA should not be ignored. Besides, quantitative real-time PCR could be considered as an accurate method for diagnosis of acute toxoplasmosis especially when the precise results are of the most importance in pregnancy. Limiting contact with cats is also suggested for pregnant women. 展开更多
关键词 TOXOPLASMOSIS TOXOPLASMA GONDII chemiluminescence IMMUNOASSAY Real time PCR PREGNANCY
下载PDF
Comparison of chemiluminescence enzyme immunoassay based on magnetic microparticles with traditional colorimetric ELISA for the detection of serum α-fetoprotein 被引量:5
14
作者 Qian-Yun Zhang a,b,Hui Chen a,Zhen Lin a,Jin-Ming Lin a a Beijing Key Laboratory of Microanalytical Methods and Instrumentation,Department of Chemistry,Tsinghua University,Beijing 100029,China b Institute of Biophysics,Chinese Academy of Sciences,Beijing 100101,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第2期130-135,共6页
A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELI... A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum a-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA).A systematic comparison between the MmPs-CLEIA and colorimetric ELISA concluded that the MPs-CLEIA exhibited fewer dosages of immunoreagents,less total assay time,and better linearity,recovery,precision,sensitivity and validity.AFP was detected in forty human serum samples by the proposed MPs-CLEIA and ELISA,and the results were compared with commercial electrochemiluminescence immunoassay (ECLIA) kit.The correlation coefficient between MPs-CLEIA and ELISA was obtained with R 2 0.6703;however,the correlation between MPs-CLEIA and ECLIA (R 2 0.9582) was obviously better than that between colorimetric ELISA and ECLIA (R 2 0.6866). 展开更多
关键词 a-Fetoprotein Hepatocellular carcinoma chemiluminescence enzyme immunoassay Magnetic microparticles Colorimetric enzyme-linked immunosorbent assay
下载PDF
A novel method for Co(Ⅱ) and Cu(Ⅱ) analysis by capillary electrophoresis with chemiluminescence detection 被引量:4
15
作者 Xiao Ming Guo Xiang Dong Xu +2 位作者 Hui Jing Zhang Yong Gang Hu Jie Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第9期1095-1098,共4页
Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The... Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/Lα-HIBA(adjusted to pH 4.8 by HAc solution).The post-capillary reagent was 2.0 mmol/L K_3Fe(CN)_6 which was adjusted to pH 13.0 by NaOH solution.Under the optimum conditions,the detection limits(S/N=3)for Co(Ⅱ)and Cu(Ⅱ)were 7.5×10^(-11)mol/L and 7.5×10^(-9)mol/L,with the linear range of 7.5×10^(-9)mol/L to 1.0×10^(-6)mol/L and 7.5×10^(-8)mol/L to 5.0×10^(-5)mol/L, respectively. 展开更多
关键词 Capillary electrophoresis chemiluminescence Co(Ⅱ) Cu(Ⅱ)
下载PDF
Determination of Gossypol in Trace Level by Flow Injection Analysis with Chemiluminescence Detection 被引量:3
16
作者 Bing Chun XUE Er Bao LIU 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第1期57-60,共4页
This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitiz... This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitized by gossypol. Under the optimum conditions, the CL intensity is proportional to the concentration of gossypol over the range of 1.11×10^-17-2.78×10^-16 mol/L in acid solution and 8.00×10^-11-7.39×10^-8mol/L in neutral solution with correlation coefficients 0.9983 and 0.9905, respectively. The detection limits is 1.60×10^-18 mol/L (S/N=3). The proposed method has been applied for the determination of the gossypol in cottonseeds and pharmaceutical formulations with satisfactory results. 展开更多
关键词 Single-molecule detection chemiluminescence flow injection gossypol.
下载PDF
Study on superoxide and hydroxyl radicals generated in indirect electrochemical oxidation by chemiluminescence and UV-Visible spectra 被引量:3
17
作者 ZHANG, Bo-Tao ZHAO, Li-Xia LIN, Jin-Ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第8期1006-1011,共6页
The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the sep... The generation and transformation of radicals on the cathode of indirect electrochemical oxidation were studied by chemilumines- cence(CL)and UV-Visible spectra in the reactor with a salt bridge that connected the separated chambers.The CL intensity of 4×10^(-9)mol/L luminol on the cathode with bubbling oxygen was about seven times that of the intensity without it,which was because of the generation of reactive oxygen species(ROS).The existence of ROS,especially the generation of the superoxide radical,coul... 展开更多
关键词 chemiluminescence(CL) UV-VISIBLE RADICAL indirect electrochemical oxidation
下载PDF
A Quantitative DNA Methylation Assay Using Mismatch Hybridization and Chemiluminescence 被引量:3
18
作者 QUN-FENGYAO XIN-JIANGKANG QIAO-LINGHAO YI-KAIZHOU 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2005年第1期48-52,共5页
To develop a quantitative method for methylation analysis of the p16 gene based on mismatch hybridization and chemiluminescence. Methods Genomic DNA was modified by sodium bisulfite to convert all unmethylated but no... To develop a quantitative method for methylation analysis of the p16 gene based on mismatch hybridization and chemiluminescence. Methods Genomic DNA was modified by sodium bisulfite to convert all unmethylated but not methylated cytosines to uracil, and subsequently a pair of primer having no CpG sites was designed for amplification target DNA containing methylated or unmethylated CpG sites. The PCR product spanning CpG sites were hybridized with two oligonucleotide probes which perfectly matched the methylated and unmethylated CpG sequences respectively, and the hybrids were detected by chemiluminescent method. The percentage of methylated target sequences could be estimated by calculating the ratio of signals obtained with two probes. Results The percentage of methylation of artificial mixtures DNA showed a linear relation. There was a negative correlation between the methyaltion index with p16 transcriptional mRNA of p16 gene in tumor cell lines. Conclusion Compared with existing methods, this assay is nonisotopic, rapid, simple, and can be widely applied to the study of DNA methylation. 展开更多
关键词 METHYLATION chemiluminescence Mismatch hybridization p16 gene
下载PDF
Chemiluminescence determination of 20 amino acids and the mechanism study 被引量:3
19
作者 Yan Ming Liu Zhuan Li Liu 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第7期856-859,共4页
It was found that 20 amino acids could inhibit the intensity of the luminol-H_2O_2-CuSO_4 chemiluminescence system.Using this character,a rapid and sensitive method for the determination of 20 amino acids was develope... It was found that 20 amino acids could inhibit the intensity of the luminol-H_2O_2-CuSO_4 chemiluminescence system.Using this character,a rapid and sensitive method for the determination of 20 amino acids was developed with flow injection coupled with chemiluminescence detection.Under the optimal conditions,the detection limits of 20 amino acids were in the range of 4.5×10^(-7)- 4.3×10^(-10) mol/L,and the relative standard deviations were less than 3.2%.The proposed method was successfully applied to drug analysis.The possible mechanism was also discussed. 展开更多
关键词 chemiluminescence Flow injection Amino acid Mechanism study
下载PDF
Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system 被引量:2
20
作者 Li-Juan Wang Yu-Hai Tang Yang-Hao Liu 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期51-56,共6页
A novel flow injection chemiluminescence(CL)method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4 and Na2SO3 in acid media.The CL intensity of KMnO4-Na2SO3 was greatly ... A novel flow injection chemiluminescence(CL)method for the determination of loxoprofen and naproxen was proposed based on the CL system of KMnO4 and Na2SO3 in acid media.The CL intensity of KMnO4-Na2SO3 was greatly enhanced in the presence of loxoprofen and naproxen.The mechanism of the CL reaction was studied by the kinetic process and UV-vis absorption and the conditions were optimized.Under optimized conditions,the CL intensity was linear with loxoprofen and naproxen concentration in the range of 7.0×10^-8-1.0×10^-5g/mL and 2.0×10^-7-4.0×10^-6g/mL with the detection limit of 2.0×10-8g/mL and 3.0×10-8g/mL(S/N=3),respectively.The relative standard deviations were 2.39% and 1.37% for 5.0×10^-7g/mL naproxen and 5.0×10^-7g/mL loxoprofen(n=10),respectively.The proposed method was satisfactorily applied to the determination of loxoprofen and naproxen in pharmaceutical preparations. 展开更多
关键词 chemiluminescence KMNO4 LOXOPROFEN NAPROXEN
下载PDF