This paper reports that the detection to the protein in microarray format is carried out by oblique-incidence reflectivity difference (OI-RD) analysis without any labelling agents. The OI-RD intensities not only dep...This paper reports that the detection to the protein in microarray format is carried out by oblique-incidence reflectivity difference (OI-RD) analysis without any labelling agents. The OI-RD intensities not only depend on the protein structure, but also vary with the protein concentration. The results indicate that this method should have potential application in detection of biochemical processes. The high throughout and in situ detection can be achieved by this method with further improving of the experimental system.展开更多
We successfully conduct the label-free and real-time detection of the interactions between epoxy groups and rabbit IgG and 5' CTT CAG GTC ATG AGC CTG AT 3' oligonucleotide, and between the hybridization of 5' CTT C...We successfully conduct the label-free and real-time detection of the interactions between epoxy groups and rabbit IgG and 5' CTT CAG GTC ATG AGC CTG AT 3' oligonucleotide, and between the hybridization of 5' CTT CAG GTC ATG AGC CTG AT 3' and its complementary 3' GAA GTC CAC TAC TCG GAC TA 5' oligonucleotide, by the oblique-incidence reflectivity difference (OI-RD) method. The dynamic curves of OI-RD signals, corresponding to the kinetic processes of biomolecular combination or hybridization, are acquired. In our case, the combination of epoxy groups with rabbit IgG and 5' CTT CAC CTC ATG AGC CTG AT 3' oligonucleotide need almost one and a half hours and about two hundred seconds, respectively; and the hybridization of the two oligonucleotides needs about five hundred seconds. The experimental results show that the OI-RD is a promising method for the real-time and label-free detection of biomolecular interactions.展开更多
Mouse-Immunoglobulin G(mouse-IgG) with different concentrations in a range from 1000 to 0.0128 μg/mL and a specific hybridization with goat anti-mouse IgG were detected successfully by using an oblique-incidence refl...Mouse-Immunoglobulin G(mouse-IgG) with different concentrations in a range from 1000 to 0.0128 μg/mL and a specific hybridization with goat anti-mouse IgG were detected successfully by using an oblique-incidence reflectivity difference(OI-RD) method.Two detection signals,consisting of an imaginary part(Im{Δp-Δs}) and a real part(Re{Δp-Δs}) of OI-RD,were obtained simultaneously.The detection results of hybridization by OI-RD were in accord with that of traditional fluorescent scans.In particular,we label-freely detected the washed mouse-IgG microarray with a series of concentrations and acquired a linear correlation between OI-RD intensities and the protein concentrations in logarithmic coordinates.The detection sensitivity of OI-RD can reach 14 fg.These experimental results suggest that the OI-RD method has potential applications in proteomics and clinical diagnosis.展开更多
基金Project supported by the Chinese Academy of Sciences for Key Topics in Innovation Engineering (Grant No L3FX051W)
文摘This paper reports that the detection to the protein in microarray format is carried out by oblique-incidence reflectivity difference (OI-RD) analysis without any labelling agents. The OI-RD intensities not only depend on the protein structure, but also vary with the protein concentration. The results indicate that this method should have potential application in detection of biochemical processes. The high throughout and in situ detection can be achieved by this method with further improving of the experimental system.
基金Project supported by the National Basic Research Program in China(Grant No.2007CB935700)
文摘We successfully conduct the label-free and real-time detection of the interactions between epoxy groups and rabbit IgG and 5' CTT CAG GTC ATG AGC CTG AT 3' oligonucleotide, and between the hybridization of 5' CTT CAG GTC ATG AGC CTG AT 3' and its complementary 3' GAA GTC CAC TAC TCG GAC TA 5' oligonucleotide, by the oblique-incidence reflectivity difference (OI-RD) method. The dynamic curves of OI-RD signals, corresponding to the kinetic processes of biomolecular combination or hybridization, are acquired. In our case, the combination of epoxy groups with rabbit IgG and 5' CTT CAC CTC ATG AGC CTG AT 3' oligonucleotide need almost one and a half hours and about two hundred seconds, respectively; and the hybridization of the two oligonucleotides needs about five hundred seconds. The experimental results show that the OI-RD is a promising method for the real-time and label-free detection of biomolecular interactions.
基金supported by the National Basic Research Program of China (Grant No. 2007CB935700)
文摘Mouse-Immunoglobulin G(mouse-IgG) with different concentrations in a range from 1000 to 0.0128 μg/mL and a specific hybridization with goat anti-mouse IgG were detected successfully by using an oblique-incidence reflectivity difference(OI-RD) method.Two detection signals,consisting of an imaginary part(Im{Δp-Δs}) and a real part(Re{Δp-Δs}) of OI-RD,were obtained simultaneously.The detection results of hybridization by OI-RD were in accord with that of traditional fluorescent scans.In particular,we label-freely detected the washed mouse-IgG microarray with a series of concentrations and acquired a linear correlation between OI-RD intensities and the protein concentrations in logarithmic coordinates.The detection sensitivity of OI-RD can reach 14 fg.These experimental results suggest that the OI-RD method has potential applications in proteomics and clinical diagnosis.