期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Reliability of Chinese web-based ocular surface disease index questionnaire in dry eye patients:a randomized,crossover study 被引量:2
1
作者 Xin-Mei Zhang Lan-Ting Yang +10 位作者 Qing Zhang Qing-Xia Fan Can Zhang Yue You Chen-Guang Zhang Tie-Zhu Lin Ling Xu Salissou Moutari Jonathan E.Moore Emmanuel E.Pazo Wei He 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第6期834-843,共10页
AIM:To assess the reliability of web-based version of ocular surface disease index in Chinese(C-OSDI)on clinically diagnosed dry eye disease(DE)patients.METHODS:A total of 254 Chinese participants(51%male,129/254;mean... AIM:To assess the reliability of web-based version of ocular surface disease index in Chinese(C-OSDI)on clinically diagnosed dry eye disease(DE)patients.METHODS:A total of 254 Chinese participants(51%male,129/254;mean age:27.90±9.06 y)with DED completed paper-and web-based versions of C-OSDI questionnaires in a randomized crossover design.Ophthalmology examination and DED diagnosis were performed prior to the participants being invited to join the study.Participants were randomly designated to either group A(paper-based first and webbased second)or group B(web-based first and paper-based second).Final data analysis included participants that had successfully completed both versions of the C-OSDI.Demographic characteristics,test-retest reliability,and agreement of individual items,subscales,and total score were evaluated with intraclass correlation coefficients(ICC),Spearman rank correlation,Wilcoxon test and Rasch analysis.RESULTS:Reliability indexes were adequate,Pearson correlation was greater than 0.8 and ICCs range was 0.827 to 0.982;total C-OSDI score was not statistically different between the two versions.The values of mean-squares fit statistics were very low compared to 1,indicating that the responses to the items by the model had a high degree of predictability.While comparing the favorability 72%(182/254)of the participants preferred web-based assessment.CONCLUSION:Web-based C-OSDI is reliable in assessing DED and correlation with the paper-based version is significant in all subscales and overall total score.Webbased C-OSDI can be administered to assess individuals with DED as participants predominantly favored online assessment. 展开更多
关键词 dry eye disease ocular surface disease index Rasch analysis test-retest reliability web-based questionnaire
下载PDF
Changes in Tear-Film Status and Ocular Surface Disease Index Score Following Prolonged Use of Face Mask
2
作者 Nawreen Binte Anwar Basil Anwar +2 位作者 Arup Krishna Choudhury Mahfuza Rahman Khan Md. Anisur Rahman 《Open Journal of Ophthalmology》 2021年第4期253-265,共13页
<strong>Background:</strong> Dry eye is characterized by tear film instability, decreased tear volume and a high Ocular Surface Disease Index (OSDI) score. Face masks have been linked to dry eye complaints... <strong>Background:</strong> Dry eye is characterized by tear film instability, decreased tear volume and a high Ocular Surface Disease Index (OSDI) score. Face masks have been linked to dry eye complaints in recent studies. <strong>Purpose:</strong> To evaluate the changes in tear-film status and Ocular Surface Disease Index (OSDI) score following prolonged use of face mask. <strong>Design:</strong> Cross-sectional study. <strong>Method:</strong> Patients between 18 to 70 years using masks regularly for at least 2 hours/day for at least 5 days/week from different eye-care centres in Dhaka were included. All subjects were divided into 4 groups. Mask use lasted approximately 2 hours/day in Group 1, 4 hours/day in Group 2, 6 hours/day in Group 3 and 8 hours or more/day in Group 4. Evaluation of symptoms, tear- film stability and tear volume was done by Ocular Surface Disease Index (OSDI) scores, Tear-film Break-Up Time (TBUT) and Schirmer-1 test. Average of right & left eye’s Tear-film Break Up time (TBUT) and Schirmer-1 value were noted. <strong>Results:</strong> Total 100 patients were enrolled (n = 100). The TBUT (p < 0.001) and Schirmer-1 measurement (p = 0.01) were significantly lesser and Ocular Surface Disease Index (OSDI) score were significantly higher in patients using face-masks for longer time (p < 0.001). <strong>Conclusion:</strong> Patients who wore masks for prolonged time had tear film instability, reduced tear volume and higher Ocular Surface Disease Index (OSDI) score. 展开更多
关键词 Tear-Film Break up Time Schirmer-1 ocular surface Disease index (OSDI) Face-Mask
下载PDF
Ocular manifestations and quality of life in patients after hematopoietic stem cell transplantation
3
作者 Shu-Xian Fan Wen-Hui Wang +5 位作者 Peng Zeng Ke-Zhi Huang Yu-Xin Hu Jing Wang Yi-Qing Li Jian-Hui Xiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1138-1144,共7页
AIM:To explore the relationship between ocular and systemic conditions and the impact of ocular complications on the quality of life(QOL)in patients after allogeneic hematopoietic stem cell transplantation(ALLO-HSCT).... AIM:To explore the relationship between ocular and systemic conditions and the impact of ocular complications on the quality of life(QOL)in patients after allogeneic hematopoietic stem cell transplantation(ALLO-HSCT).METHODS:Forty-four patients with severe hematopoietic disease were enrolled after ALLO-HSCT at our center from July 2018 to October 2020.They completed two questionnaires:the Ocular Surface Disease Index(OSDI)and the quality-of-life scale for Chinese patients with visual impairment(SQOL-DV1).Ocular conditions and systemic conditions were also assessed.RESULTS:Eye damage was correlated with total bilirubin(P=0.005),and gamma-glutamyl transferase(GGT)(P=0.021).There was no significant correlation between the overall QOL score and OSDI(P=0.8226)or SQOLDV1(P=0.9526)scores.The OSDI and the overall QOL score were not correlated with ocular conditions,including best-corrected visual acuity(BCVA),intraocular pressure,Schirmer tear test II,sodium fluorescein staining,tear film breakup time,and tear meniscus height.SQOLDV1 was correlated with BCVA(P=0.0007),sodium fluorescein staining(P=0.007),and tear film breakup time(P=0.0146).CONCLUSION:In some patients,early ocular symptoms are not evident after ALLO-HSCT,while ocular surface complications can be observed after a comprehensive ophthalmological examination.Especially for those with elevated total bilirubin or GGT,regular ophthalmic follow-up visits are essential to diagnose and treat ocular graft versus host disease(o GVHD),especially for patients with elevated total bilirubin or GGT. 展开更多
关键词 allogeneic stem cell transplantation ocular graft versus host disease ocular surface disease quality of life quality-of-life scale for Chinese patients with visual impairment ocular surface Disease index
下载PDF
Eye reflux:an ocular extraesophageal manifestation of gastric reflux 被引量:2
4
作者 Danilo Mazzacane Valerio Damiani +2 位作者 Michela Silvestri Giorgio Ciprandi Pierfranco Marino 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第9期1503-1507,共5页
AIM: To suspect laryngopharyngeal reflux(LPR) in patients with ocular surface disease(OSD). METHODS: The present study evaluated a group of subjects with OSD assessing the Ocular Surface Disease Index(OSDI) an... AIM: To suspect laryngopharyngeal reflux(LPR) in patients with ocular surface disease(OSD). METHODS: The present study evaluated a group of subjects with OSD assessing the Ocular Surface Disease Index(OSDI) and the Reflux Symptom Index(RSI) to detect patients with suspected LPR and define a possible relationship between tests.RESULTS: Two hundred and ninety subjects(175 females, mean age: 60.41±15.68y) were consecutively visited at ophthalmologist offices. One hundred and one(34%) patients had pathological RSI(〉13) and consequently a suspected LPR.CONCLUSION: The current study shows that suspected LPR may be common(34%) in patients with OSD and a suspected LPR may be considered in OSD patients when RSI score is 〉13 and OSDI score is 〉42. 展开更多
关键词 gastric reflux eye reflux ocular surface disease index reflux symptom score
下载PDF
Topographic tear film trend and new parameters for noninvasive break up time test
5
作者 Yakup Acet 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第12期1932-1939,共8页
AIM:To evaluate the quantitative and qualitative results of the noninvasive tear film break-up time(NI-BUT)test and investigate the predictive ability of the new NIBUT parameter in discriminating between normal Ocular... AIM:To evaluate the quantitative and qualitative results of the noninvasive tear film break-up time(NI-BUT)test and investigate the predictive ability of the new NIBUT parameter in discriminating between normal Ocular Surface Disease Index(OSDI;scores≤12)and abnormal OSDI(scores≥13).METHODS:A total of 341 eyes of 341 volunteers who applied for routine eye outpatient control were included in the prospective study.All participants'noninvasive first tear film break-up time(NIF-BUT),noninvasive average tear film break-up time(NIAvg-BUT)and average value of the first three break-up time(A3F-BUT)were analyzed.A3F-BUT,the new NI-BUT parameter,is calculated by adding the NIF-BUT value to the 2^(nd )break-up time value that has a difference of at most 1 second from the NIF-BUT value and to the 3^(rd) break-up time and then dividing the respective sum by 3.Receiver operating characteristic(ROC)curve and forward logistic regression analyses were performed to determine the parameter that had the best predictive ability between the OSDI groups.RESULTS:The NI-BUT values of 255 eyes of 255 volunteers included in the study were analyzed statistically.The mean NIF-BUT,NIAvg-BUT,and A3F-BUT values were calculated as 5.3±3.0,8±3.1,and 5.8±3.0 seconds,respectively.All three parameters were found to be significantly lower in the abnormal OSDI group(P=0.014,0.034,and 0.011,respectively).The area under the curve(AUC)of the A3F-BUT to predict abnormal OSDI was AUC=0.625(0.529-0.720),P=0.011 and NIF-BUT was AUC=0.599(0.502-0.696),P=0.043.The A3F-BUT parameter and NIF-BUT parameters were found to be significantly efficient in discriminating abnormal OSDI.CONCLUSION:The new parameter for the NI-BUT test has more predictive ability in the discrimination of OSDI groups. 展开更多
关键词 noninvasive break-up time ocular surface Disease index tear film topographic break-up time test
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部