To take advantage of micelle to solvent stacking (MSS) to achieve more sensitivity enhancement with enough selectivity, the application of capillary electrophoretic online sequential concentration based on the MSS was...To take advantage of micelle to solvent stacking (MSS) to achieve more sensitivity enhancement with enough selectivity, the application of capillary electrophoretic online sequential concentration based on the MSS was reviewed. MSS has been coupled to sweeping FASS, FASI and normal EKI. Furthermore, multiple stacking by coupling MSS with more than one stacking method has also been reported. It is more sensitive and selective than solely used of one or two stacking methods and is very suitable for complex and trace sample analysis.展开更多
The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been propos...The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described..An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm^3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4 85.7 aM, and the LOD (3a) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.展开更多
A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in micellar electrokinetic chromatography (MEKC) was developed. Various parameters ...A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in micellar electrokinetic chromatography (MEKC) was developed. Various parameters affecting sample enrichment and separation efficiency were systematically studied. Compared with the conventional MEKC method, up to 60-200-fold improvement in concentration sensitivity was achieved in terms of peak height by using this sweeping injection technique. The compound strychnine was used as the internal standard for the improvement of the experimental reproducibility. The limits of detection (S/ N = 3:1) for atrazine, simazine and prometryn were 9, 10 and 0.5 ng mL-1, respectively. This method has been successfully applied to the analysis of atrazine, simazine and prometryn in lake, steam and ground water.展开更多
A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodio...A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodiode array detection. Under the optimal conditions, the calibration curve was linear over a range of 0.5-40μg·mL^-1 for CBZ with a correlation coefficient of 0.998. The detection limit (S/N = 3:1) of CBZ was 0.10 μg·mL^-1. The sweeping-MEKC method has been successfully applied to the analysis of CBZ in human serum.展开更多
Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their d...Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+).展开更多
An on-line forecasting model based on self-tuning support vectors regression for zinc output was put forward to maximize zinc output by adjusting operational parameters in the process of imperial smelting furnace. In ...An on-line forecasting model based on self-tuning support vectors regression for zinc output was put forward to maximize zinc output by adjusting operational parameters in the process of imperial smelting furnace. In this model, the mathematical model of support vector regression was converted into the same format as support vector machine for classification. Then a simplified sequential minimal optimization for classification was applied to train the regression coefficient vector α- α* and threshold b. Sequentially penalty parameter C was tuned dynamically through forecasting result during the training process. Finally, an on-line forecasting algorithm for zinc output was proposed. The simulation result shows that in spite of a relatively small industrial data set, the effective error is less than 10% with a remarkable performance of real time. The model was applied to the optimization operation and fault diagnosis system for imperial smelting furnace.展开更多
为提升家用雾化制氧机的用户体验及满意度,提出结合用户体验模型,采用半结构化访谈方式归纳用户需求并建立评价层级体系;采用序关系分析法进行需求指标权重计算及优度排序;通过功能分析系统技术(Function Analysis System Technique,FA...为提升家用雾化制氧机的用户体验及满意度,提出结合用户体验模型,采用半结构化访谈方式归纳用户需求并建立评价层级体系;采用序关系分析法进行需求指标权重计算及优度排序;通过功能分析系统技术(Function Analysis System Technique,FAST)功能树获取产品功能要素,指导设计方案输出;采用模糊综合评价(Fuzzy Comprehensive Evaluation,FCE)法对产品设计方案进行用户满意度评价。研究结果表明:基于序关系分析法和FCE法设计的家用雾化制氧机具有较高的用户满意度,设计方法的集成提升了用户需求获取与方案评价环节的效率及科学性,可为同类产品的创新设计提供参考。展开更多
Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection samp...Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection sampling technology. The determination is based on the color reaction of Pb(Ⅱ) with iodide and crystal violet to form an ionic association complex in the presence of polyvinyl alcohol and hydrochloric acid. The use of the microcolumn can prevent the interference of most familiar metal ions, and therefore improve the selectivity and sensitivity of this analytical technique. The proposed method was used for the determination of Pb(Ⅱ) in environmental samples and wastewater. No statistically significant difference was observed between the results determined by the present method and atomic absorption spectrometry.展开更多
文摘To take advantage of micelle to solvent stacking (MSS) to achieve more sensitivity enhancement with enough selectivity, the application of capillary electrophoretic online sequential concentration based on the MSS was reviewed. MSS has been coupled to sweeping FASS, FASI and normal EKI. Furthermore, multiple stacking by coupling MSS with more than one stacking method has also been reported. It is more sensitive and selective than solely used of one or two stacking methods and is very suitable for complex and trace sample analysis.
基金The National High Technology Research and Development Program of China under contract Nos 2006AA09Z174 and 2007AA061501the National Natural Science Foundation of China under contract No. 40521003
文摘The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described..An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm^3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4 85.7 aM, and the LOD (3a) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%-108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.
基金sponsored by the Natural Science Foundation of Hebei (Nos.B2006000413,B2008000210).
文摘A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in micellar electrokinetic chromatography (MEKC) was developed. Various parameters affecting sample enrichment and separation efficiency were systematically studied. Compared with the conventional MEKC method, up to 60-200-fold improvement in concentration sensitivity was achieved in terms of peak height by using this sweeping injection technique. The compound strychnine was used as the internal standard for the improvement of the experimental reproducibility. The limits of detection (S/ N = 3:1) for atrazine, simazine and prometryn were 9, 10 and 0.5 ng mL-1, respectively. This method has been successfully applied to the analysis of atrazine, simazine and prometryn in lake, steam and ground water.
文摘A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodiode array detection. Under the optimal conditions, the calibration curve was linear over a range of 0.5-40μg·mL^-1 for CBZ with a correlation coefficient of 0.998. The detection limit (S/N = 3:1) of CBZ was 0.10 μg·mL^-1. The sweeping-MEKC method has been successfully applied to the analysis of CBZ in human serum.
基金Projects(61533021,61321003,61273185)supported by the National Natural Science Foundation of ChinaProject(2015CX007)supported by the Innovation-driven Plan in Central South University,ChinaProject(13JJ8003)supported by the Joint Fund of Hunan Provincial Natural Science Foundation of China
文摘Reagents are optimized for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in zinc sulfate solution, which contains an extremely large excess of Zn^(2+). First, the reagents and their doses for the experiment are selected according to the characteristics of the zinc sulfate solution. Then, the reagent doses are optimized by analyzing the influence of reagent dose on the polarographic parameters(i.e. half-wave potential E_(1/2) and limiting diffusion current I_p). Finally, the optimization results are verified by simultaneously determining trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+). The determination results indicate that the optimized reagents exhibit wide linearity, low detection limits, high accuracy and good precision for the simultaneous determination of trace amounts of Cu^(2+), Cd^(2+) and Co^(2+) in the presence of an extremely large excess of Zn^(2+).
文摘An on-line forecasting model based on self-tuning support vectors regression for zinc output was put forward to maximize zinc output by adjusting operational parameters in the process of imperial smelting furnace. In this model, the mathematical model of support vector regression was converted into the same format as support vector machine for classification. Then a simplified sequential minimal optimization for classification was applied to train the regression coefficient vector α- α* and threshold b. Sequentially penalty parameter C was tuned dynamically through forecasting result during the training process. Finally, an on-line forecasting algorithm for zinc output was proposed. The simulation result shows that in spite of a relatively small industrial data set, the effective error is less than 10% with a remarkable performance of real time. The model was applied to the optimization operation and fault diagnosis system for imperial smelting furnace.
基金supported by the Science and Technology Department of Henan Province (082300423202 & 102300410194)
文摘Trace of Pb(Ⅱ) has been on-line separated and enriched from environmental samples and wastewater by using the self-made alizarin violet functionalized silica gel micro-column coupling with a sequential injection sampling technology. The determination is based on the color reaction of Pb(Ⅱ) with iodide and crystal violet to form an ionic association complex in the presence of polyvinyl alcohol and hydrochloric acid. The use of the microcolumn can prevent the interference of most familiar metal ions, and therefore improve the selectivity and sensitivity of this analytical technique. The proposed method was used for the determination of Pb(Ⅱ) in environmental samples and wastewater. No statistically significant difference was observed between the results determined by the present method and atomic absorption spectrometry.