期刊文献+
共找到32,640篇文章
< 1 2 250 >
每页显示 20 50 100
On-Site Calibration Method of Dosimeter Based on X-Ray Source
1
作者 Wenhui Lv Huiping Guo +4 位作者 Ning Lv Chenyang Tian Kuo Zhao Xiaotian Wang Yijie Hou 《World Journal of Nuclear Science and Technology》 2017年第2期93-102,共10页
The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nu... The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary &gamma;-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation. 展开更多
关键词 X RAY SOURCE on-site calibration Energy Response GAMMA RADIATION DOSIMETER
下载PDF
A dual-RPA based lateral flow strip for sensitive,on-site detection of CP4-EPSPS and Cry1Ab/Ac genes in genetically modified crops 被引量:1
2
作者 Jinbin Wang Yu Wang +7 位作者 Xiuwen Hu Yifan Chen Wei Jiang Xiaofeng Liu Juan Liu Lemei Zhu Haijuan Zeng Hua Liu 《Food Science and Human Wellness》 SCIE CSCD 2024年第1期183-190,共8页
Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSP... Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSPS and Cry1Ab/Ac was proposed and combined with a lateral flow immunochromatographic assay,named“Dual-RPA-LFD”,to visualize the dual detection of genetically modified(GM)crops.In which,the herbicide tolerance gene CP4-EPSPS and the insect resistance gene Cry1Ab/Ac were selected as targets taking into account the current status of the most widespread application of insect resistance and herbicide tolerance traits and their stacked traits.Gradient diluted plasmids,transgenic standards,and actual samples were used as templates to conduct sensitivity,specificity,and practicality assays,respectively.The constructed method achieved the visual detection of plasmid at levels as low as 100 copies,demonstrating its high sensitivity.In addition,good applicability to transgenic samples was observed,with no cross-interference between two test lines and no influence from other genes.In conclusion,this strategy achieved the expected purpose of simultaneous detection of the two popular targets in GM crops within 20 min at 37°C in a rapid,equipmentfree field manner,providing a new alternative for rapid screening for transgenic assays in the field. 展开更多
关键词 Genetically modifi ed crops on-site detection Lateral fl ow test strips Dual recombinase polymerase amplification (RPA)
下载PDF
A Weakly-Supervised Crowd Density Estimation Method Based on Two-Stage Linear Feature Calibration
3
作者 Yong-Chao Li Rui-Sheng Jia +1 位作者 Ying-Xiang Hu Hong-Mei Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第4期965-981,共17页
In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd dat... In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd datasets,and propose a crowd density estimation method based on weakly-supervised learning,in the absence of crowd position supervision information,which directly reduces the number of crowds by using the number of pedestrians in the image as the supervised information.For this purpose,we design a new training method,which exploits the correlation between global and local image features by incremental learning to train the network.Specifically,we design a parent-child network(PC-Net)focusing on the global and local image respectively,and propose a linear feature calibration structure to train the PC-Net simultaneously,and the child network learns feature transfer factors and feature bias weights,and uses the transfer factors and bias weights to linearly feature calibrate the features extracted from the Parent network,to improve the convergence of the network by using local features hidden in the crowd images.In addition,we use the pyramid vision transformer as the backbone of the PC-Net to extract crowd features at different levels,and design a global-local feature loss function(L2).We combine it with a crowd counting loss(LC)to enhance the sensitivity of the network to crowd features during the training process,which effectively improves the accuracy of crowd density estimation.The experimental results show that the PC-Net significantly reduces the gap between fullysupervised and weakly-supervised crowd density estimation,and outperforms the comparison methods on five datasets of Shanghai Tech Part A,ShanghaiTech Part B,UCF_CC_50,UCF_QNRF and JHU-CROWD++. 展开更多
关键词 Crowd density estimation linear feature calibration vision transformer weakly-supervision learning
下载PDF
Calibration of CO and CO2 Monitors Used in Periodic Inspection of Vehicles at Fixed Stations for Environmental Control
4
作者 Adel Bassuoni Shehata Abdulrahman Rashed Al Askar +2 位作者 Najjy Hamad Al Yami Abdullah Suleiman Al Owaysi Sultan K. Alharbi 《Green and Sustainable Chemistry》 2024年第2期29-41,共13页
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri... Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment. 展开更多
关键词 MONITORS Periodic Inspection CO/CO2 calibration LINEARITY Precision Accuracy
下载PDF
Parameter calibration of the tensile-shear interactive damage constitutive model for sandstone failure
5
作者 Yun Shu Zheming Zhu +4 位作者 Meng Wang Weiting Gao Fei Wang Duanying Wan Yuntao Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第4期1153-1174,共22页
The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The bas... The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The basic parameters of sandstone are determined through a series of static and dynamic tests,including uniaxial compression,Brazilian disc,triaxial compression under varying confining pressures,hydrostatic compression,and dynamic compression and tensile tests with a split Hopkinson pressure bar.Based on the sandstone test results from this study and previous research,a step-by-step procedure for parameter calibration is outlined,which accounts for the categories of the strength surface,equation of state(EOS),strain rate effect,and damage.The calibrated parameters are verified through numerical tests that correspond to the experimental loading conditions.Consistency between numerical results and experimental data indicates the precision and reliability of the calibrated parameters.The methodology presented in this study is scientifically sound,straightforward,and essential for improving the TSID model.Furthermore,it has the potential to contribute to other rock constitutive models,particularly new user-defined models. 展开更多
关键词 Damage constitutive model Parameter calibration Rock modeling SANDSTONE Dynamic impact load Tensile-shear interactive damage(TSID)model
下载PDF
Global Calibration Method for Monocular Multi-View System Using Rotational Dual-Target
6
作者 Kun He Hongwei He 《Open Journal of Applied Sciences》 2024年第5期1192-1203,共12页
To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calib... To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calibration method is proposed for the geometric properties of rotational correlation motion and the absolute orientation of the field of view without over lap. Firstly, a dual-camera system is constructed for photographing and collecting the rotating image sequence of two flat targets rigidly connected by a long rod at different positions, and based on the known parameters, such as, target feature image, world coordinates, camera internal parameters and so on, then the global PnP optimization method is used to solve the rotation axis and the reference point at different positions;Then, the absolute orientation matrix is constructed based on the parameters of rotation axis, reference point and connecting rod length obtained by this method. In the end, the singular value decomposition method is used to find the optimal rotation matrix, and then get the translation matrix. It’s shown based on simulation and actual tests that in comparison with the existing methods, the maximum attitude and pose errors is 0.0083˚ and 0.3657 mm, respectively, which improves the accuracy by 27.8% and 24.4%, respectively. The calibration device in this paper is simple, and there are no parallel, vertical and coplanar requirements between multiple rotating positions. At the same time, in view of the calibration accuracy, the accuracy requirements of most application scenarios can be met. 展开更多
关键词 Machine Vision Accurate Demarcating Global calibration Absolute Orientation
下载PDF
On the calibration and verification of Voronoi-based discontinuous deformation analysis for modeling rock fracture 被引量:2
7
作者 Kaiyu Zhang Feng Liu +3 位作者 Kaiwen Xia Ying Xu Peng Dong Changyi Yu 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第8期2025-2038,共14页
Since its introduction,discontinuous deformation analysis(DDA)has been widely used in different areas of rock mechanics.By dividing large blocks into subblocks and introducing artificial joints,DDA can be applied to r... Since its introduction,discontinuous deformation analysis(DDA)has been widely used in different areas of rock mechanics.By dividing large blocks into subblocks and introducing artificial joints,DDA can be applied to rock fracture simulation.However,parameter calibration,a fundamental issue in discontinuum methods,has not received enough attention in DDA.In this study,the parameter calibration of DDA for intact rock is carefully studied.To this end,a subblock DDA with Voronoi tessellation is presented first.Then,a modified contact constitutive law is introduced,in which the tensile and shear meso-strengths are modified to be independent of the bond lengths.This improvement can prevent the unjustified preferential failure of short edges.A method for imposing confining pressure is also introduced.Thereafter,sensitivity analysis is performed to investigate the influence of the calculated parameters and meso-parameters on the mechanical properties of modeled rock.Based on the sensitivity analysis,a unified calibration procedure is suggested for both cases with and without confining pressure.Finally,the calibration procedure is applied to two examples,including a biaxial compression test.The results show that the proposed Voronoi-based DDA can simulate rock fracture with and without confining pressure very well after careful parameter calibration. 展开更多
关键词 Discontinuous deformation analysis(DDA) Voronoi tessellation Parameter calibration Confining pressure Rock fracture
下载PDF
Design and development of the deep-rock in-situ condition-preserved coring calibration platform 被引量:1
8
作者 Yihang Li Heping Xie +8 位作者 Ru Zhang Zetian Zhang Zhilong Zhang Heng Gao Wei Huang Jixun Zhang Jiming Gao Xin Ma Ruibing Xu 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2023年第11期1377-1395,共19页
To systematically validate and calibrate the theory and technology of the deep in-situ conditionpreserved coring, the in-situ conditions at different depths should be simulated, and the full-size coring tests should b... To systematically validate and calibrate the theory and technology of the deep in-situ conditionpreserved coring, the in-situ conditions at different depths should be simulated, and the full-size coring tests should be carried out in this simulated environment. Therefore, a deep-rock in-situ conditionpreserved coring calibration platform was designed and developed. The self-tightening sealing structure and the quick-disassembly structure were designed on the basis of an innovative segmented nonuniformdiameter structure, which was a breakthrough from the traditional high-pressure vessel frame and was verified by finite element simulation and actual testing under extreme working conditions, respectively.To simulate the actual deep in-situ environment with a temperature of 150℃ and pressure of 140 MPa for a large Φ450 mm×H1400 mm core, temperature and pressure control systems were designed by coupling, and a pre-embedded high-pressure-resistant temperature sensor was designed. Finally, highprecision assembly automation, complex movement coordination of the coring device with the platform,and rotary dynamic sealing were achieved by utilizing the combination of adaptive cabin body servo control and an adaptive mechanical structure in a limited space, laying a solid foundation for the calibration of in-situ condition-preserved coring. 展开更多
关键词 In-situ condition-preserved coring calibration Deep Earth science Coring simulation Rotary dynamic seal
下载PDF
Easy to Calibrate:Marker-Less Calibration of Multiview Azure Kinect
9
作者 Sunyoung Bu Suwon Lee 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第9期3083-3096,共14页
Reconstructing a three-dimensional(3D)environment is an indispensable technique to make augmented reality and augmented virtuality feasible.A Kinect device is an efficient tool for reconstructing 3D environments,and u... Reconstructing a three-dimensional(3D)environment is an indispensable technique to make augmented reality and augmented virtuality feasible.A Kinect device is an efficient tool for reconstructing 3D environments,and using multiple Kinect devices enables the enhancement of reconstruction density and expansion of virtual spaces.To employ multiple devices simultaneously,Kinect devices need to be calibrated with respect to each other.There are several schemes available that calibrate 3D images generated frommultiple Kinect devices,including themarker detection method.In this study,we introduce a markerless calibration technique for Azure Kinect devices that avoids the drawbacks of marker detection,which directly affects calibration accuracy;it offers superior userfriendliness,efficiency,and accuracy.Further,we applied a joint tracking algorithm to approximate the calibration.Traditional methods require the information of multiple joints for calibration;however,Azure Kinect,the latest version of Kinect,requires the information of only one joint.The obtained result was further refined using the iterative closest point algorithm.We conducted several experimental tests that confirmed the enhanced efficiency and accuracy of the proposed method for multiple Kinect devices when compared to the conventional markerbased calibration. 展开更多
关键词 Azure Kinect Kinect calibration marker-less calibration 3D reconstruction iterative closest point
下载PDF
On-orbit Geometric Calibration and Preliminary Accuracy Evaluation of GF-14 Satellite
10
作者 Xueliang LU Jianrong WANG +4 位作者 Xiuce YANG Yuan LYU Yan HU Bincai CAO Junming ZHOU 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期62-70,共9页
GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Poi... GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Points(GCPs).In fact,space-based high-precision mapping without GCPs is a challenging task that depends on the close cooperation of several payloads and links,of which on-orbit geometric calibration is one of the most critical links.In this paper,the on-orbit geometric calibration of the dual-line array cameras of GF-14 satellite was performed using the control points collected in the high-precision digital calibration field,and the calibration parameters of the dual-line array cameras were solved as a whole by alternate iterations of forward and backward intersection.On this basis,the location accuracy of the stereo images using the calibration parameters was preliminarily evaluated by using several test fields around the world.The evaluation result shows that the direct forward intersection accuracy of GF-14 satellite images without GCPs after on-orbit geometric calibration reaches 2.34 meters(RMS)in plane and 1.97 meters(RMS)in elevation. 展开更多
关键词 GF-14 satellite high-precision digital calibration field on-orbit geometric calibration without ground control points accuracy evaluation
下载PDF
Cross-satellite calibration of high-energy electron fluxes measured by FengYun-4A based on Arase observations
11
作者 XiaoYu Wang Xing Cao +5 位作者 Xin Ma XiaoXin Zhang AnQin Chen JunHu Dong BinBin Ni XianKang Dou 《Earth and Planetary Physics》 CAS CSCD 2023年第5期565-575,共11页
We use the High-energy Electron Experiments(HEP)instrument onboard Arase(ERG)to conduct an energy-dependent cross-satellite calibration of electron fluxes measured by the High Energy Particle Detector(HEPD)onboard Fen... We use the High-energy Electron Experiments(HEP)instrument onboard Arase(ERG)to conduct an energy-dependent cross-satellite calibration of electron fluxes measured by the High Energy Particle Detector(HEPD)onboard FengYun-4A(FY-4A)spanning from April 1,2017,to September 30,2019.By tracing the two-dimensional magnetic positions(L,magnetic local time[MLT])of FY-4A at each time,we compare the datasets of the conjugate electron fluxes over the range of 245–894 keV in 6 energy channels for the satellite pair within different sets of L×MLT.The variations in the electron fluxes observed by FY-4A generally agree with the Arase measurements,and the percentages of the ratios of electron flux conjunctions within a factor of 2 are larger than 50%.Compared with Arase,FY-4A systematically overestimates electron fluxes at all 6 energy channels,with the corresponding calibration factors ranging from 0.67 to 0.81.After the cross-satellite calibration,the electron flux conjunctions between FY-4A and Arase show better agreement,with much smaller normalized root mean square errors.Our results provide a valuable reference for the application of FY-4A high-energy electron datasets to in-depth investigations of the Earth’s radiation belt electron dynamics. 展开更多
关键词 cross-satellite calibration high-energy electron flux FengYun-4A Arase
下载PDF
Cheesy material on macroscopic on-site evaluation after endoscopic ultrasound-guided fine-needle biopsy:Don't miss the tuberculosis
12
作者 Hanane Delsa Khadija Bellahammou +1 位作者 Hussein Hassan Okasha Fahd Ghalim 《World Journal of Clinical Cases》 SCIE 2023年第10期2181-2188,共8页
Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluat... Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluation(MOSE)performed by an endoscopist was introduced as an alternative to rapid on-site cytologic evaluation to increase the diagnostic yield of EUS-FNB.The MOSE of the biopsy can estimate the adequacy of the sample directly by the macroscopic evaluation of the core tissue obtained from EUS-FNB.Isolated pancreatic tuberculosis is extremely rare and difficult to diagnose because of its non-specific signs and symptoms.Therefore,this challenging diagnosis is based on endoscopy,imaging,and the bacteriological and histological examination of tissue biopsies.This uncommon presentation of tuberculosis can be revealed as pancreatic mass mimicking cancer.EUS-FNB can be very useful in providing a valuable histopathological diagnosis.A calcified lesion with a cheesy core in MOSE must be suggestive of tuberculosis,leading to the request of the GeneXpert,which can detect Mycobacterium tuberculosis deoxyribonucleic acid and resistance to rifampicin.A decent diagnostic strategy is crucial to prevent unnecessary surgical resection and to supply conservative management with antitubercular therapy. 展开更多
关键词 Pancreatic tuberculosis Endoscopic ultrasound Fine-needle biopsy Macroscopic on-site evaluation Cheesy material GeneXpert
下载PDF
A machine learning approach to TCAD model calibration for MOSFET
13
作者 Bai‑Chuan Wang Chuan‑Xiang Tang +4 位作者 Meng‑Tong Qiu Wei Chen Tan Wang Jing‑Yan Xu Li‑Li Ding 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期133-145,共13页
Machine learning-based surrogate models have significant advantages in terms of computing efficiency. In this paper, we present a pilot study on fast calibration using machine learning techniques. Technology computer-... Machine learning-based surrogate models have significant advantages in terms of computing efficiency. In this paper, we present a pilot study on fast calibration using machine learning techniques. Technology computer-aided design(TCAD) is a powerful simulation tool for electronic devices. This simulation tool has been widely used in the research of radiation effects.However, calibration of TCAD models is time-consuming. In this study, we introduce a fast calibration approach for TCAD model calibration of metal–oxide–semiconductor field-effect transistors(MOSFETs). This approach utilized a machine learning-based surrogate model that was several orders of magnitude faster than the original TCAD simulation. The desired calibration results were obtained within several seconds. In this study, a fundamental model containing 26 parameters is introduced to represent the typical structure of a MOSFET. Classifications were developed to improve the efficiency of the training sample generation. Feature selection techniques were employed to identify important parameters. A surrogate model consisting of a classifier and a regressor was built. A calibration procedure based on the surrogate model was proposed and tested with three calibration goals. Our work demonstrates the feasibility of machine learning-based fast model calibrations for MOSFET. In addition, this study shows that these machine learning techniques learn patterns and correlations from data instead of employing domain expertise. This indicates that machine learning could be an alternative research approach to complement classical physics-based research. 展开更多
关键词 Machine learning Radiation effects Surrogate model TCAD model calibration
下载PDF
Ground calibration of the Mars orbiter magnetometer onboard Tianwen-1
14
作者 ManMing Chen Kai Liu +3 位作者 XiaoWen Hu YiRen Li XinJun Hao ZongHao Pan 《Earth and Planetary Physics》 EI CSCD 2023年第3期371-377,共7页
Ground calibration experiments of the Mars orbiter magnetometer(MOMAG)onboard the orbiter of Tianwen-1 were performed to determine the sensitivity,misalignment angle,and offset of the sensors.The linearity of the appl... Ground calibration experiments of the Mars orbiter magnetometer(MOMAG)onboard the orbiter of Tianwen-1 were performed to determine the sensitivity,misalignment angle,and offset of the sensors.The linearity of the applied calibrated magnetic fields and the output from the sensors were confirmed to be better than 10^(-4),and the sensor axes were orthogonal to each other within 0.5 degrees.The temperature dependencies of the sensitivity and misalignment angle were examined,but no clear signatures of temperature dependencies could be seen.Sensor offset and the stability of sensor offset drift with a temperature change were also determined by the rotation method.The stability of the sensor offset drift was less than 0.01 nT/℃.The ground calibration of MOMAG determines all the calibration parameters of the sensors for accurate magnetic field measurements in orbit with the appropriate corrections. 展开更多
关键词 Mars orbiter magnetometer Tianwen-1 ground calibration
下载PDF
Novel camera calibration method based on invariance of collinear points and pole-polar constraint
15
作者 WEI Liang ZHANG Guiyang +1 位作者 HUO Ju XUE Muyao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2023年第3期744-753,共10页
To address the eccentric error of circular marks in camera calibration,a circle location method based on the invariance of collinear points and pole–polar constraint is proposed in this paper.Firstly,the centers of t... To address the eccentric error of circular marks in camera calibration,a circle location method based on the invariance of collinear points and pole–polar constraint is proposed in this paper.Firstly,the centers of the ellipses are extracted,and the real concentric circle center projection equation is established by exploiting the cross ratio invariance of the collinear points.Subsequently,since the infinite lines passing through the centers of the marks are parallel,the other center projection coordinates are expressed as the solution problem of linear equations.The problem of projection deviation caused by using the center of the ellipse as the real circle center projection is addressed,and the results are utilized as the true image points to achieve the high precision camera calibration.As demonstrated by the simulations and practical experiments,the proposed method performs a better location and calibration performance by achieving the actual center projection of circular marks.The relevant results confirm the precision and robustness of the proposed approach. 展开更多
关键词 camera calibration cross ratio invariance infinite lines eccentricity error compensate
下载PDF
An Improved Calibration Method of Grating Projection Measurement System
16
作者 Qiucheng Sun Weiyu Dai +2 位作者 Mingyu Sun Zeming Ren Mingze Wang 《Computers, Materials & Continua》 SCIE EI 2023年第5期3957-3970,共14页
In the traditional fringe projection profilometry system,the projector and the camera light center are both spatially virtual points.The spatial position relationships specified in the model are not easy to obtain,lea... In the traditional fringe projection profilometry system,the projector and the camera light center are both spatially virtual points.The spatial position relationships specified in the model are not easy to obtain,leading to inaccurate system parameters and affectingmeasurement accuracy.This paper proposes a method for solving the system parameters of the fringe projection profilometry system,and the spatial position of the camera and projector can be adjusted in accordance with the obtained calibration parameters.The steps are as follows:First,in accordance with the conversion relationship of the coordinate system in the calibration process,the calculation formula of the vertical distance from the camera light center to the reference plane and the calculation formula of the distance between the projector and the camera light center are given respectively.Secondly,according to the projector calibration principle,the position of the projector light axis perpendicular to the reference plane is gained by comparing the parallel relationship between the reference plane coordinate system and the projector coordinate system’s Z-axis.Then,in order to fulfill the position restriction that the line between the projector light center and the camera light center must be parallel to the reference plane,the camera’s spatial location is adjusted so that the vertical distance between it and the reference plane tends to that between the projector light center and the reference plane.And finally,the three-dimensional(3D)reconstruction of the target object can be finished using the phase height model’s system parameters once the aforementioned position limitations are put into practice.Experimental results demonstrate that the method improves the measurement accuracy,and verifies that it is effective and available in 3D shape measurement. 展开更多
关键词 3D measurement calibration phase shift phase height model
下载PDF
Feasibility of maintaining satellite altimetry calibration site based on qianliyan islet at the Yellow Sea
17
作者 Bin Guan Zhongmiao Sun +2 位作者 Lei Yang Zhenhe Zhai Jian Ma 《Geodesy and Geodynamics》 EI CSCD 2023年第3期223-230,共8页
The calibration of the sea surface height(SSH)measured by satellite altimeters is essential to understand altimeter biases.Many factors affects the construction and maintenance of a permanent calibration site.In order... The calibration of the sea surface height(SSH)measured by satellite altimeters is essential to understand altimeter biases.Many factors affects the construction and maintenance of a permanent calibration site.In order to calibrate Chinese satellite altimetry missions,the feasibility of maintaining a calibration site based on the Qianliyan islet in Yellow Sea of China is taken into account.The related calibration facilities,such as the permanent tide gauge,GNSS reference station and meteorological station,were already operated by the Ministry of Natural Resources of China.The data could be fully used for satellite altimeter calibration with small fiscal expenditure.In addition,the location and marine environments of Qianliyan were discussed.Finally,we used the Jason-3 mission to check the possibility of calibration works.The result indicates that the brightness temperatures of three channels measured by microwave radiometer(MWR)and the derived wet tropospheric correction varies smoothly,which means the land contamination to MWR could be ignored.The high frequency waveforms at the Qianliyan site present no obvious difference from the normal waveforms received by satellite radar altimeter over the open ocean.In conclusion,the Qianliyan islet will not influence satellite altimetry observation.Following these analyses,a possible layout and mechanism of the Qianliyan calibration site are proposed. 展开更多
关键词 Satellite altimetry Altimeter calibration Satellite radar altimeter Microwave radiometer JASON Tide gauge
下载PDF
Traceability Technology of DC Electric Energy Metering for On-Site Inspection of Chargers
18
作者 Hua Li Dezhi Xiong Zhi Wang 《Energy Engineering》 EI 2023年第3期715-727,共13页
The on-site inspection of high-power DC chargers results in new DC high-current measurement and DC energy traceability system requirements.This paper studies the traceability technology of electric energy value for au... The on-site inspection of high-power DC chargers results in new DC high-current measurement and DC energy traceability system requirements.This paper studies the traceability technology of electric energy value for automotive high-power DC chargers,including:(1)the traceability method of the built-in DC energy meter and shunt of the charger;(2)precision DC high current and small precision DC voltage output and measurement technology.This paper designs a 0.1 mA∼600 A DC high current measurement system and proposes a 0.005 level DC powermeasurement traceability system.The uncertainty evaluation experiment of theDC powermeasurement calibration system and the high-power DC charger’s on-site calibration experiment results verify the method’s effectiveness and feasibility in this paper.The experimental results show that the combined standard uncertainty of the DC power metering verification system can be 0.0451%. 展开更多
关键词 DC electric energy measurement CHARGER TRACEABILITY calibration
下载PDF
A Comparative Study on Kinematic Calibration for a 3-DOF Parallel Manipulator Using the Complete-Minimal,Inverse-Kinematic and Geometric-Constraint Error Models
19
作者 Haiyu Wu Lingyu Kong +2 位作者 Qinchuan Li Hao Wang Genliang Chen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第5期206-230,共25页
Kinematic calibration is a reliable way to improve the accuracy of parallel manipulators, while the error model dramatically afects the accuracy, reliability, and stability of identifcation results. In this paper, a c... Kinematic calibration is a reliable way to improve the accuracy of parallel manipulators, while the error model dramatically afects the accuracy, reliability, and stability of identifcation results. In this paper, a comparison study on kinematic calibration for a 3-DOF parallel manipulator with three error models is presented to investigate the relative merits of diferent error modeling methods. The study takes into consideration the inverse-kinematic error model, which ignores all passive joint errors, the geometric-constraint error model, which is derived by special geometric constraints of the studied RPR-equivalent parallel manipulator, and the complete-minimal error model, which meets the complete, minimal, and continuous criteria. This comparison focuses on aspects such as modeling complexity, identifcation accuracy, the impact of noise uncertainty, and parameter identifability. To facilitate a more intuitive comparison, simulations are conducted to draw conclusions in certain aspects, including accuracy, the infuence of the S joint, identifcation with noises, and sensitivity indices. The simulations indicate that the complete-minimal error model exhibits the lowest residual values, and all error models demonstrate stability considering noises. Hereafter, an experiment is conducted on a prototype using a laser tracker, providing further insights into the diferences among the three error models. The results show that the residual errors of this machine tool are signifcantly improved according to the identifed parameters, and the complete-minimal error model can approach the measurements by nearly 90% compared to the inverse-kinematic error model. The fndings pertaining to the model process, complexity, and limitations are also instructive for other parallel manipulators. 展开更多
关键词 Kinematic calibration Parallel manipulator Error modeling Product of exponential(POE)
下载PDF
Prediction of Uncertainty Estimation and Confidence Calibration Using Fully Convolutional Neural Network
20
作者 Karim Gasmi Lassaad Ben Ammar +1 位作者 Hmoud Elshammari Fadwa Yahya 《Computers, Materials & Continua》 SCIE EI 2023年第5期2557-2573,共17页
Convolution neural networks(CNNs)have proven to be effective clinical imagingmethods.This study highlighted some of the key issues within these systems.It is difficult to train these systems in a limited clinical imag... Convolution neural networks(CNNs)have proven to be effective clinical imagingmethods.This study highlighted some of the key issues within these systems.It is difficult to train these systems in a limited clinical image databases,and many publications present strategies including such learning algorithm.Furthermore,these patterns are known formaking a highly reliable prognosis.In addition,normalization of volume and losses of dice have been used effectively to accelerate and stabilize the training.Furthermore,these systems are improperly regulated,resulting in more confident ratings for correct and incorrect classification,which are inaccurate and difficult to understand.This study examines the risk assessment of Fully Convolutional Neural Networks(FCNNs)for clinical image segmentation.Essential contributions have been made to this planned work:1)dice loss and cross-entropy loss are compared on the basis of segment quality and uncertain assessment of FCNNs;2)proposal for a group model for assurance measurement of full convolutional neural networks trained with dice loss and group normalization;And 3)the ability of the measured FCNs to evaluate the segment quality of the structures and to identify test examples outside the distribution.To evaluate the study’s contributions,it conducted a series of tests in three clinical image division applications such as heart,brain and prostate.The findings of the study provide significant insights into the predictive ambiguity assessment and a practical strategies for outside-distribution identification and reliable measurement in the clinical image segmentation.The approaches presented in this research significantly enhance the reliability and accuracy rating of CNNbased clinical imaging methods. 展开更多
关键词 Medical image SEGMENTATION confidence calibration uncertainty estimation fully convolutional neural network
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部