期刊文献+
共找到33,425篇文章
< 1 2 250 >
每页显示 20 50 100
A rapid on-site calibration method for measuring dynamic envelope curve of high-speed trains
1
作者 LIU Chang-jie YANG Du-juan +1 位作者 FU Lu-hua WANG Zhong 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第3期205-214,共10页
Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve... Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve of a train,the speed of which is over200km/h.Nevertheless the method has two limitations,one is large field-〇f-view(FO V),the other is calibration time.Hence portable calibration equipment,easy-t〇-build target and rapid calibration algorithm are required to complete the calibration.In this paper,a new rapid on-site calibration method with large FOV based on binocular stereo vision is proposed.To address these issues,a light target has been designed,the rail coordinate system(RCS)is represented by40fixed retroreflective points on the target,and they are utilized to calibrate the parameters of two cameras.In addition,two cameras merely capture a single image of the target simultaneously,and the intrinsic and extrinsic parameters of the cameras can be calculated rapidly.To testify the proposed method,the experiments have been conducted and the results reveal that the accuracy can reach+1mm,which can meet the measurement requirement. 展开更多
关键词 high-speed train dynamic envelope curve on-site calibration field-〇f-view (FOV)
下载PDF
On-Site Calibration Method of Dosimeter Based on X-Ray Source
2
作者 Wenhui Lv Huiping Guo +4 位作者 Ning Lv Chenyang Tian Kuo Zhao Xiaotian Wang Yijie Hou 《World Journal of Nuclear Science and Technology》 2017年第2期93-102,共10页
The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nu... The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary &gamma;-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation. 展开更多
关键词 X RAY SOURCE on-site calibration Energy Response GAMMA RADIATION DOSIMETER
下载PDF
A dual-RPA based lateral flow strip for sensitive,on-site detection of CP4-EPSPS and Cry1Ab/Ac genes in genetically modified crops 被引量:1
3
作者 Jinbin Wang Yu Wang +7 位作者 Xiuwen Hu Yifan Chen Wei Jiang Xiaofeng Liu Juan Liu Lemei Zhu Haijuan Zeng Hua Liu 《Food Science and Human Wellness》 SCIE CSCD 2024年第1期183-190,共8页
Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSP... Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSPS and Cry1Ab/Ac was proposed and combined with a lateral flow immunochromatographic assay,named“Dual-RPA-LFD”,to visualize the dual detection of genetically modified(GM)crops.In which,the herbicide tolerance gene CP4-EPSPS and the insect resistance gene Cry1Ab/Ac were selected as targets taking into account the current status of the most widespread application of insect resistance and herbicide tolerance traits and their stacked traits.Gradient diluted plasmids,transgenic standards,and actual samples were used as templates to conduct sensitivity,specificity,and practicality assays,respectively.The constructed method achieved the visual detection of plasmid at levels as low as 100 copies,demonstrating its high sensitivity.In addition,good applicability to transgenic samples was observed,with no cross-interference between two test lines and no influence from other genes.In conclusion,this strategy achieved the expected purpose of simultaneous detection of the two popular targets in GM crops within 20 min at 37°C in a rapid,equipmentfree field manner,providing a new alternative for rapid screening for transgenic assays in the field. 展开更多
关键词 Genetically modifi ed crops on-site detection Lateral fl ow test strips Dual recombinase polymerase amplification (RPA)
下载PDF
Non-crossing Quantile Regression Neural Network as a Calibration Tool for Ensemble Weather Forecasts 被引量:1
4
作者 Mengmeng SONG Dazhi YANG +7 位作者 Sebastian LERCH Xiang'ao XIA Gokhan Mert YAGLI Jamie M.BRIGHT Yanbo SHEN Bai LIU Xingli LIU Martin Janos MAYER 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第7期1417-1437,共21页
Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantil... Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantile regression(QR)is highly competitive in terms of both flexibility and predictive performance.Nevertheless,a long-standing problem of QR is quantile crossing,which greatly limits the interpretability of QR-calibrated forecasts.On this point,this study proposes a non-crossing quantile regression neural network(NCQRNN),for calibrating ensemble NWP forecasts into a set of reliable quantile forecasts without crossing.The overarching design principle of NCQRNN is to add on top of the conventional QRNN structure another hidden layer,which imposes a non-decreasing mapping between the combined output from nodes of the last hidden layer to the nodes of the output layer,through a triangular weight matrix with positive entries.The empirical part of the work considers a solar irradiance case study,in which four years of ensemble irradiance forecasts at seven locations,issued by the European Centre for Medium-Range Weather Forecasts,are calibrated via NCQRNN,as well as via an eclectic mix of benchmarking models,ranging from the naïve climatology to the state-of-the-art deep-learning and other non-crossing models.Formal and stringent forecast verification suggests that the forecasts post-processed via NCQRNN attain the maximum sharpness subject to calibration,amongst all competitors.Furthermore,the proposed conception to resolve quantile crossing is remarkably simple yet general,and thus has broad applicability as it can be integrated with many shallow-and deep-learning-based neural networks. 展开更多
关键词 ensemble weather forecasting forecast calibration non-crossing quantile regression neural network CORP reliability diagram POST-PROCESSING
下载PDF
A real-time calibration method based on time-to-digital converter for accelerator timing system
5
作者 Qi-Hao Duan Liang Ge +2 位作者 Yan-Hao Jia Jie-Yu Zhu Wei Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期127-140,共14页
The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed ov... The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF. 展开更多
关键词 HIAF White rabbit calibration system Time-to-digital converter(TDC)
下载PDF
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
6
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
下载PDF
A Weakly-Supervised Crowd Density Estimation Method Based on Two-Stage Linear Feature Calibration
7
作者 Yong-Chao Li Rui-Sheng Jia +1 位作者 Ying-Xiang Hu Hong-Mei Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第4期965-981,共17页
In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd dat... In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd datasets,and propose a crowd density estimation method based on weakly-supervised learning,in the absence of crowd position supervision information,which directly reduces the number of crowds by using the number of pedestrians in the image as the supervised information.For this purpose,we design a new training method,which exploits the correlation between global and local image features by incremental learning to train the network.Specifically,we design a parent-child network(PC-Net)focusing on the global and local image respectively,and propose a linear feature calibration structure to train the PC-Net simultaneously,and the child network learns feature transfer factors and feature bias weights,and uses the transfer factors and bias weights to linearly feature calibrate the features extracted from the Parent network,to improve the convergence of the network by using local features hidden in the crowd images.In addition,we use the pyramid vision transformer as the backbone of the PC-Net to extract crowd features at different levels,and design a global-local feature loss function(L2).We combine it with a crowd counting loss(LC)to enhance the sensitivity of the network to crowd features during the training process,which effectively improves the accuracy of crowd density estimation.The experimental results show that the PC-Net significantly reduces the gap between fullysupervised and weakly-supervised crowd density estimation,and outperforms the comparison methods on five datasets of Shanghai Tech Part A,ShanghaiTech Part B,UCF_CC_50,UCF_QNRF and JHU-CROWD++. 展开更多
关键词 Crowd density estimation linear feature calibration vision transformer weakly-supervision learning
下载PDF
A new calibration method for radon detector in seismic systems
8
作者 Hongwei Ren Yaowei Liu 《Earthquake Science》 2024年第5期445-458,共14页
Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector ... Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector calibration in seismic systems in China is faced with a series of bottleneck problems,such as aging and scrap,acquisition difficulties,high supervision costs,and transportation limitations of radon sources.As a result,a large number of radon detectors cannot be accurately calibrated regularly,seriously affecting the accuracy and reliability of radon observation data in China.To solve this problem,a new calibration method for radon detectors was established.The advantage of this method is that the dangerous radioactive substance,i.e.,the radon source,can be avoided,but only“standard instruments”and water samples with certain dissolved radon concentrations can be used to realize radon detector calibration.This method avoids the risk of radioactive leakage and solves the current widespread difficulties and bottleneck of radon detector calibration in seismic systems in China.The comparison experiment with the traditional calibration method shows that the error of the calibration coefficient obtained by the new method is less than 5%compared with that by the traditional method,which meets the requirements of seismic observation systems,confirming the reliability of the new method.This new method can completely replace the traditional calibration method of using a radon source in seismic systems. 展开更多
关键词 radon detector calibration “standard instrument” scintillation chamber radon source
下载PDF
Kinematic calibration under the expectation maximization framework for exoskeletal inertial motion capture system
9
作者 QIN Weiwei GUO Wenxin +2 位作者 HU Chen LIU Gang SONG Tainian 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期769-779,共11页
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ... This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method. 展开更多
关键词 human motion capture kinematic calibration EXOSKELETON gyroscopic drift expectation maximization(EM)
下载PDF
Role of macroscopic on-site evaluation of endoscopic ultrasoundguided fine-needle aspiration/biopsy:Results of a multicentric prospective study
10
作者 Hussein H Okasha Hiwa A Hussein +24 位作者 Khaled M Ragab Omar Abdallah Fedoua Rouibaa Borahma Mohamed Fahd Ghalim Mahmoud Farouk Mohamed Lasheen Mohamed A Elbasiony Ahmed E Alzamzamy Ahmed El Deeb Hassan Atalla Mahmoud El-Ansary Sahar Mohamed Moaz Elshair Wafaa Khannoussi Mohamed Z Abu-Amer Amine Elmekkaoui Mohammed S Naguib Adil Ait Errami Ahmed El-Meligui Ahmed H El-Habashi Mahmoud G Ameen Dalia Abdelfatah Mona Kaddah Hanane Delsa 《World Journal of Gastrointestinal Endoscopy》 2024年第11期595-606,共12页
BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent stud... BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent studies suggest that MOSE by the endoscopist may be an excellent alternative to rapid on-site evaluation,and some classi-fications have been published.Few studies have assessed the adequacy of histologic cores in MOSE during endoscopic ultrasound-guided fine-needle aspiration/biopsy(EUS-FNA/FNB).AIM To evaluate the performance of MOSE during EUS-FNA/FNB.METHODS This multicentric prospective study was conducted in 16 centers in 3 countries(Egypt,Iraq,and Morocco)and included 1108 patients with pancreatic,biliary,or gastrointestinal pathology who were referred for EUS examination.We prospectively analyzed the MOSE in 1008 patients with available histopathological reports according to 2 classifications to determine the adequacy of the histological core samples.Data management and analysis were performed using a Statistical Package for Social Sciences(SPSS)version 27.RESULTS A total of 1074 solid lesions were biopsied in 1008 patients with available cytopathological reports.Mean age was 59 years,and 509 patients(50.5%)were male.The mean lesion size was 38 mm.The most frequently utilized needles were FNB-Franseen(74.5%)and 22 G(93.4%),with a median of 2 passes.According to 2 classifications,618 non-bloody cores(61.3%)and 964 good samples(95.6%)were adequate for histological evaluation.The overall diagnostic yield of cytopathology was 95.5%.The cytological examination confirmed the diagnosis of malignancy in 861 patients(85.4%),while 45 samples(4.5%)were inconclusive.Post-procedural adverse events occurred in 33 patients(3.3%).Statistical analysis showed a difference between needle types(P=0.035)with a high sensitivity of FNB(97%).The analysis of the relationship between the MOSE-score and the final diagnosis showed a significant difference between the different scores of the MOSE(P<0.001).CONCLUSION MOSE is a simple method that allows endoscopists to increase needle passes to improve sample quality.There is significantly higher FNB sensitivity and cytopathology diagnostic yield with good MOSE cores. 展开更多
关键词 Macroscopic on-site evaluation Fine-needle aspiration Fine-needle biopsy Endoscopic ultrasound SPECIMEN
下载PDF
Calibration of CO and CO2 Monitors Used in Periodic Inspection of Vehicles at Fixed Stations for Environmental Control
11
作者 Adel Bassuoni Shehata Abdulrahman Rashed Al Askar +2 位作者 Najjy Hamad Al Yami Abdullah Suleiman Al Owaysi Sultan K. Alharbi 《Green and Sustainable Chemistry》 2024年第2期29-41,共13页
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri... Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment. 展开更多
关键词 MONITORS Periodic Inspection CO/CO2 calibration LINEARITY Precision Accuracy
下载PDF
Parameter calibration of the tensile-shear interactive damage constitutive model for sandstone failure
12
作者 Yun Shu Zheming Zhu +4 位作者 Meng Wang Weiting Gao Fei Wang Duanying Wan Yuntao Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第4期1153-1174,共22页
The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The bas... The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The basic parameters of sandstone are determined through a series of static and dynamic tests,including uniaxial compression,Brazilian disc,triaxial compression under varying confining pressures,hydrostatic compression,and dynamic compression and tensile tests with a split Hopkinson pressure bar.Based on the sandstone test results from this study and previous research,a step-by-step procedure for parameter calibration is outlined,which accounts for the categories of the strength surface,equation of state(EOS),strain rate effect,and damage.The calibrated parameters are verified through numerical tests that correspond to the experimental loading conditions.Consistency between numerical results and experimental data indicates the precision and reliability of the calibrated parameters.The methodology presented in this study is scientifically sound,straightforward,and essential for improving the TSID model.Furthermore,it has the potential to contribute to other rock constitutive models,particularly new user-defined models. 展开更多
关键词 Damage constitutive model Parameter calibration Rock modeling SANDSTONE Dynamic impact load Tensile-shear interactive damage(TSID)model
下载PDF
Global Calibration Method for Monocular Multi-View System Using Rotational Dual-Target
13
作者 Kun He Hongwei He 《Open Journal of Applied Sciences》 2024年第5期1192-1203,共12页
To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calib... To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calibration method is proposed for the geometric properties of rotational correlation motion and the absolute orientation of the field of view without over lap. Firstly, a dual-camera system is constructed for photographing and collecting the rotating image sequence of two flat targets rigidly connected by a long rod at different positions, and based on the known parameters, such as, target feature image, world coordinates, camera internal parameters and so on, then the global PnP optimization method is used to solve the rotation axis and the reference point at different positions;Then, the absolute orientation matrix is constructed based on the parameters of rotation axis, reference point and connecting rod length obtained by this method. In the end, the singular value decomposition method is used to find the optimal rotation matrix, and then get the translation matrix. It’s shown based on simulation and actual tests that in comparison with the existing methods, the maximum attitude and pose errors is 0.0083˚ and 0.3657 mm, respectively, which improves the accuracy by 27.8% and 24.4%, respectively. The calibration device in this paper is simple, and there are no parallel, vertical and coplanar requirements between multiple rotating positions. At the same time, in view of the calibration accuracy, the accuracy requirements of most application scenarios can be met. 展开更多
关键词 Machine Vision Accurate Demarcating Global calibration Absolute Orientation
下载PDF
On the calibration and verification of Voronoi-based discontinuous deformation analysis for modeling rock fracture 被引量:2
14
作者 Kaiyu Zhang Feng Liu +3 位作者 Kaiwen Xia Ying Xu Peng Dong Changyi Yu 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第8期2025-2038,共14页
Since its introduction,discontinuous deformation analysis(DDA)has been widely used in different areas of rock mechanics.By dividing large blocks into subblocks and introducing artificial joints,DDA can be applied to r... Since its introduction,discontinuous deformation analysis(DDA)has been widely used in different areas of rock mechanics.By dividing large blocks into subblocks and introducing artificial joints,DDA can be applied to rock fracture simulation.However,parameter calibration,a fundamental issue in discontinuum methods,has not received enough attention in DDA.In this study,the parameter calibration of DDA for intact rock is carefully studied.To this end,a subblock DDA with Voronoi tessellation is presented first.Then,a modified contact constitutive law is introduced,in which the tensile and shear meso-strengths are modified to be independent of the bond lengths.This improvement can prevent the unjustified preferential failure of short edges.A method for imposing confining pressure is also introduced.Thereafter,sensitivity analysis is performed to investigate the influence of the calculated parameters and meso-parameters on the mechanical properties of modeled rock.Based on the sensitivity analysis,a unified calibration procedure is suggested for both cases with and without confining pressure.Finally,the calibration procedure is applied to two examples,including a biaxial compression test.The results show that the proposed Voronoi-based DDA can simulate rock fracture with and without confining pressure very well after careful parameter calibration. 展开更多
关键词 Discontinuous deformation analysis(DDA) Voronoi tessellation Parameter calibration Confining pressure Rock fracture
下载PDF
A machine learning approach to TCAD model calibration for MOSFET 被引量:1
15
作者 Bai‑Chuan Wang Chuan‑Xiang Tang +4 位作者 Meng‑Tong Qiu Wei Chen Tan Wang Jing‑Yan Xu Li‑Li Ding 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期133-145,共13页
Machine learning-based surrogate models have significant advantages in terms of computing efficiency. In this paper, we present a pilot study on fast calibration using machine learning techniques. Technology computer-... Machine learning-based surrogate models have significant advantages in terms of computing efficiency. In this paper, we present a pilot study on fast calibration using machine learning techniques. Technology computer-aided design(TCAD) is a powerful simulation tool for electronic devices. This simulation tool has been widely used in the research of radiation effects.However, calibration of TCAD models is time-consuming. In this study, we introduce a fast calibration approach for TCAD model calibration of metal–oxide–semiconductor field-effect transistors(MOSFETs). This approach utilized a machine learning-based surrogate model that was several orders of magnitude faster than the original TCAD simulation. The desired calibration results were obtained within several seconds. In this study, a fundamental model containing 26 parameters is introduced to represent the typical structure of a MOSFET. Classifications were developed to improve the efficiency of the training sample generation. Feature selection techniques were employed to identify important parameters. A surrogate model consisting of a classifier and a regressor was built. A calibration procedure based on the surrogate model was proposed and tested with three calibration goals. Our work demonstrates the feasibility of machine learning-based fast model calibrations for MOSFET. In addition, this study shows that these machine learning techniques learn patterns and correlations from data instead of employing domain expertise. This indicates that machine learning could be an alternative research approach to complement classical physics-based research. 展开更多
关键词 Machine learning Radiation effects Surrogate model TCAD model calibration
下载PDF
Design and development of the deep-rock in-situ condition-preserved coring calibration platform 被引量:1
16
作者 Yihang Li Heping Xie +8 位作者 Ru Zhang Zetian Zhang Zhilong Zhang Heng Gao Wei Huang Jixun Zhang Jiming Gao Xin Ma Ruibing Xu 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2023年第11期1377-1395,共19页
To systematically validate and calibrate the theory and technology of the deep in-situ conditionpreserved coring, the in-situ conditions at different depths should be simulated, and the full-size coring tests should b... To systematically validate and calibrate the theory and technology of the deep in-situ conditionpreserved coring, the in-situ conditions at different depths should be simulated, and the full-size coring tests should be carried out in this simulated environment. Therefore, a deep-rock in-situ conditionpreserved coring calibration platform was designed and developed. The self-tightening sealing structure and the quick-disassembly structure were designed on the basis of an innovative segmented nonuniformdiameter structure, which was a breakthrough from the traditional high-pressure vessel frame and was verified by finite element simulation and actual testing under extreme working conditions, respectively.To simulate the actual deep in-situ environment with a temperature of 150℃ and pressure of 140 MPa for a large Φ450 mm×H1400 mm core, temperature and pressure control systems were designed by coupling, and a pre-embedded high-pressure-resistant temperature sensor was designed. Finally, highprecision assembly automation, complex movement coordination of the coring device with the platform,and rotary dynamic sealing were achieved by utilizing the combination of adaptive cabin body servo control and an adaptive mechanical structure in a limited space, laying a solid foundation for the calibration of in-situ condition-preserved coring. 展开更多
关键词 In-situ condition-preserved coring calibration Deep Earth science Coring simulation Rotary dynamic seal
下载PDF
Model-Free Adaptive Frequency Calibration for Voltage-Controlled Oscillators 被引量:1
17
作者 Lianghui Xie Zhi Quan +1 位作者 Osama Elnaha Qinglin Zhao 《China Communications》 SCIE CSCD 2023年第1期199-208,共10页
The operating frequency accuracy of the local oscillators is critical for the overall system performance in the communication systems.However,the high-precision oscillators could be too expensive for civil application... The operating frequency accuracy of the local oscillators is critical for the overall system performance in the communication systems.However,the high-precision oscillators could be too expensive for civil applications.In this paper,we propose a model-free adaptive frequency calibration framework for a voltage-controlled crystal oscillator(VCO)equipped with a time to digital converter(TDC),which can significantly improve the frequency accuracy of the VCO thus calibrated.The idea is to utilize a high-precision TDC to directly measure the VCO period which is then passed to a model-free method for working frequency calibration.One advantage of this method is that the working frequency calibration employs the system history of input/output(I/O)data,instead of establishing an accurate VCO voltagecontrolled oscillator model.Another advantage is the lightweight calibration method with low complexity such that it can be implemented on an MCU with limited computation capabilities.Experimental results show that the proposed calibration method can improve the frequency accuracy of a VCO from±20 ppm to±10 ppb,which indicates the promise of the modelfree adaptive frequency calibrator for VCOs. 展开更多
关键词 frequency calibration carrier frequency offset MODEL-FREE adaptive control wireless communication systems
下载PDF
Easy to Calibrate:Marker-Less Calibration of Multiview Azure Kinect
18
作者 Sunyoung Bu Suwon Lee 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第9期3083-3096,共14页
Reconstructing a three-dimensional(3D)environment is an indispensable technique to make augmented reality and augmented virtuality feasible.A Kinect device is an efficient tool for reconstructing 3D environments,and u... Reconstructing a three-dimensional(3D)environment is an indispensable technique to make augmented reality and augmented virtuality feasible.A Kinect device is an efficient tool for reconstructing 3D environments,and using multiple Kinect devices enables the enhancement of reconstruction density and expansion of virtual spaces.To employ multiple devices simultaneously,Kinect devices need to be calibrated with respect to each other.There are several schemes available that calibrate 3D images generated frommultiple Kinect devices,including themarker detection method.In this study,we introduce a markerless calibration technique for Azure Kinect devices that avoids the drawbacks of marker detection,which directly affects calibration accuracy;it offers superior userfriendliness,efficiency,and accuracy.Further,we applied a joint tracking algorithm to approximate the calibration.Traditional methods require the information of multiple joints for calibration;however,Azure Kinect,the latest version of Kinect,requires the information of only one joint.The obtained result was further refined using the iterative closest point algorithm.We conducted several experimental tests that confirmed the enhanced efficiency and accuracy of the proposed method for multiple Kinect devices when compared to the conventional markerbased calibration. 展开更多
关键词 Azure Kinect Kinect calibration marker-less calibration 3D reconstruction iterative closest point
下载PDF
On-orbit Geometric Calibration and Preliminary Accuracy Evaluation of GF-14 Satellite
19
作者 Xueliang LU Jianrong WANG +4 位作者 Xiuce YANG Yuan LYU Yan HU Bincai CAO Junming ZHOU 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期62-70,共9页
GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Poi... GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Points(GCPs).In fact,space-based high-precision mapping without GCPs is a challenging task that depends on the close cooperation of several payloads and links,of which on-orbit geometric calibration is one of the most critical links.In this paper,the on-orbit geometric calibration of the dual-line array cameras of GF-14 satellite was performed using the control points collected in the high-precision digital calibration field,and the calibration parameters of the dual-line array cameras were solved as a whole by alternate iterations of forward and backward intersection.On this basis,the location accuracy of the stereo images using the calibration parameters was preliminarily evaluated by using several test fields around the world.The evaluation result shows that the direct forward intersection accuracy of GF-14 satellite images without GCPs after on-orbit geometric calibration reaches 2.34 meters(RMS)in plane and 1.97 meters(RMS)in elevation. 展开更多
关键词 GF-14 satellite high-precision digital calibration field on-orbit geometric calibration without ground control points accuracy evaluation
下载PDF
Cross-satellite calibration of high-energy electron fluxes measured by FengYun-4A based on Arase observations
20
作者 XiaoYu Wang Xing Cao +5 位作者 Xin Ma XiaoXin Zhang AnQin Chen JunHu Dong BinBin Ni XianKang Dou 《Earth and Planetary Physics》 CAS CSCD 2023年第5期565-575,共11页
We use the High-energy Electron Experiments(HEP)instrument onboard Arase(ERG)to conduct an energy-dependent cross-satellite calibration of electron fluxes measured by the High Energy Particle Detector(HEPD)onboard Fen... We use the High-energy Electron Experiments(HEP)instrument onboard Arase(ERG)to conduct an energy-dependent cross-satellite calibration of electron fluxes measured by the High Energy Particle Detector(HEPD)onboard FengYun-4A(FY-4A)spanning from April 1,2017,to September 30,2019.By tracing the two-dimensional magnetic positions(L,magnetic local time[MLT])of FY-4A at each time,we compare the datasets of the conjugate electron fluxes over the range of 245–894 keV in 6 energy channels for the satellite pair within different sets of L×MLT.The variations in the electron fluxes observed by FY-4A generally agree with the Arase measurements,and the percentages of the ratios of electron flux conjunctions within a factor of 2 are larger than 50%.Compared with Arase,FY-4A systematically overestimates electron fluxes at all 6 energy channels,with the corresponding calibration factors ranging from 0.67 to 0.81.After the cross-satellite calibration,the electron flux conjunctions between FY-4A and Arase show better agreement,with much smaller normalized root mean square errors.Our results provide a valuable reference for the application of FY-4A high-energy electron datasets to in-depth investigations of the Earth’s radiation belt electron dynamics. 展开更多
关键词 cross-satellite calibration high-energy electron flux FengYun-4A Arase
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部