期刊文献+
共找到36,953篇文章
< 1 2 250 >
每页显示 20 50 100
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:7
1
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 Liquid chromatography–tandem mass spectrometry on-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
Tracking gassing behavior in pouch cell by operando on-line electrochemical mass spectrometry
2
作者 Haitang Zhang Jianken Chen +10 位作者 Baodan Zhang Xiaohong Wu Zhengang Li Leiyu Chen Junhao Wang Xiaoyu Yu Haiyan Luo Jiyuan Xue Yu-Hao Hong Yu Qiao Shi-Gang Sun 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第9期286-291,共6页
As the rapid development of more powerful and safer lithiumion batteries, the mechanism study of gases evolution is attacking more and more attention in recent years. Especially under overcharge/discharge and/or high-... As the rapid development of more powerful and safer lithiumion batteries, the mechanism study of gases evolution is attacking more and more attention in recent years. Especially under overcharge/discharge and/or high-temperature working condition. 展开更多
关键词 Pouch cell Operando characterization mass spectrometry Lithium-ion batteries Gassing behavior
下载PDF
On-Line Photoionization Mass Spectrometric Study on Behavior of Ammonia Poisoning on H-Form Ultra Stable Y Zeolite for Catalytic Pyrolysis of Polypropylene
3
作者 Yi-zun Wang Jiu-zhong Yang +3 位作者 Yang Pan Hao Ma Yu-yang Li Fei Qi 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第6期681-686,I0001,共7页
In this work, pyrolysis photoionization time-of-flight mass spectrometry (Py-PI-TOFMS) was applied to study the behavior of ammonia poisoning on H-form ultra stable Y (HUSY) zeolite for the catalytic pyrolysis of ... In this work, pyrolysis photoionization time-of-flight mass spectrometry (Py-PI-TOFMS) was applied to study the behavior of ammonia poisoning on H-form ultra stable Y (HUSY) zeolite for the catalytic pyrolysis of polypropylene (PP). Firstly, ammonia poisoning on HUSY was performed to obtain the suitable catalysts with different strength and amounts of acid sites. Secondly, online photoionization mass spectra for the pyrolysis products of PP and HUSY with various acid strength were recorded at different pyrolysis temperatures. Finally, the formation curves of various pyrolysates of PP/HUSY with the increase of temperature were determined. Our results indicate that the formation temperatures, yields and selectivity of the pyrolysis products of PP demonstrate obvious relationship with the acid strength of HUSY. 展开更多
关键词 H-form ultra stable Y zeolite zeolites POLYPROPYLENE Catalytic pyrolysis Ammonia poisoning Photoionization mass spectrometry
下载PDF
Use of a TG-Bridge/Mass Spectrometry Method for On-line Monitoring the Emissions of Pine Needles Combustion
4
作者 M. Statheropoulos N. Tzamtzis +2 位作者 A. Pappa S. Karma Naian Liu 《火灾科学》 CSCD 2004年第3期135-144,共10页
森林火灾排放物主要包含气体、挥发性有机化合物(VOCs)、和半挥发性有机化合物(SVOCs),这些物质会严重威胁消防队员和居民的健康。森林火灾烟气是一种包含固体颗粒、液体和气体化合物的复杂混合物。在火前锋附近(靠近消防队员)或者离火... 森林火灾排放物主要包含气体、挥发性有机化合物(VOCs)、和半挥发性有机化合物(SVOCs),这些物质会严重威胁消防队员和居民的健康。森林火灾烟气是一种包含固体颗粒、液体和气体化合物的复杂混合物。在火前锋附近(靠近消防队员)或者离火前锋很远(但靠近居民)的地方,当苯、甲苯、烯烃等有机化合物的浓度超过各健康安全组织规定的极限值,就可能对健康产生影响。本文给出了一种使用室内热重桥 质谱联用对炉内松针燃烧实验进行火前锋排放物在线监测的新方法。该燃烧实验被认为含氧量较低,这是真实森林火灾中通常的情形。使用这种方法测量得到的苯和甲苯的最大浓度分别是1050和2050ppm。CO2的最大浓度超过10.000ppm。 展开更多
关键词 松针燃烧排放物 热重桥/质谱监测方法 挥发性有机化合物 VOCs 森林火灾 大气检测技术
下载PDF
Stepped-up development of accelerator mass spectrometry method for the detection of ^(60)Fe with the HI-13 tandem accelerator 被引量:1
5
作者 Yang Zhang Sheng-Quan Yan +36 位作者 Ming He Qing-Zhang Zhao Wen-Hui Zhang Chao-Xin Kan Jian-Ming Zhou Kang-Ning Li Xiao-Fei Wang Jian-Cheng Liu Zhao-Hua Peng Zhuo Liang Ai-Ling Li Jian Zheng Qi-Wen Fan Yun-Ju Li You-Bao Wang Zhi-Hong Li Yang-Ping Shen Ding Nan Wei Nan Yu-Qiang Zhang Jia-Ying-Hao Li Jun-Wen Tian Jiang-Lin Hou Chang-Xin Guo Zhi-Cheng Zhang Ming-Hao Zhu Yu-Wen Chen Yu-Chen Jiang Tao Tian Jin-Long Ma Yi-Hui Liu Jing-Yu Dong Run-Long Liu Mei-Yue-Nan Ma Yong-Shou Chen Wei-Ping Liu Bing Guo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期136-143,共8页
The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides... The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides such as^(60)Fe.In this work,we stepped up the development of an accelerator mass spectrometry(AMS)method for detecting^(60)Fe using the HI-13tandem accelerator at the China Institute of Atomic Energy(CIAE).Since interferences could not be sufficiently removed solely with the existing magnetic systems of the tandem accelerator and the following Q3D magnetic spectrograph,a Wien filter with a maximum voltage of±60 kV and a maximum magnetic field of 0.3 T was installed after the accelerator magnetic systems to lower the detection background for the low abundance nuclide^(60)Fe.A 1μm thick Si_(3)N_(4) foil was installed in front of the Q3D as an energy degrader.For particle detection,a multi-anode gas ionization chamber was mounted at the center of the focal plane of the spectrograph.Finally,an^(60)Fe sample with an abundance of 1.125×10^(-10)was used to test the new AMS system.These results indicate that^(60)Fe can be clearly distinguished from the isobar^(60)Ni.The sensitivity was assessed to be better than 4.3×10^(-14)based on blank sample measurements lasting 5.8 h,and the sensitivity could,in principle,be expected to be approximately 2.5×10^(-15)when the data were accumulated for 100 h,which is feasible for future lunar sample measurements because the main contaminants were sufficiently separated. 展开更多
关键词 Accelerator mass spectrometry Wien filter Isobar separation SUPERNOVAE Chang'e-5 lunar samples
下载PDF
Improved isochronous mass spectrometry with tune measurement
6
作者 Han-Yu Deng Yuan-Ming Xing +5 位作者 Xu Zhou Yu-Hu Zhang Xin-Liang Yan Jin-Yang Shi Ting Liao Meng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第11期174-181,共8页
In conventional isochronous mass spectrometry(IMS)performed on a storage ring,the precision of mass measurements for short-lived nuclei depends on the accurate determination of the revolution times(T)of stored ions.Ho... In conventional isochronous mass spectrometry(IMS)performed on a storage ring,the precision of mass measurements for short-lived nuclei depends on the accurate determination of the revolution times(T)of stored ions.However,the resolution of T inevitably deteriorates due to the magnetic rigidity spread of the ions,limiting the mass-resolving power.In this study,we used the betatron tunes Q(the number of betatron oscillations per revolution)of the ions and established a correlation between T and Q.From this correlation,T was transformed to correspond to a fixed Q with higher resolution.Using these transformed T values,the masses of ^(63)Ge,^(65)As,^(67)Se,and ^(71)Kr agreed well with the mass values measured using the newly developed IMS(Bρ-IMS).We also studied the systematics of Coulomb displacement energies(CDEs)and found that anomalous staggering in CDEs was eliminated using new mass values.This method of T transformation is highly effective for conventional IMS equipped with a single time-of-flight detector. 展开更多
关键词 Isochronous mass spectrometry Storage ring TUNE Natural chromaticity Nuclear mass measurement
下载PDF
Mass Spectrometry-based Deep Coverage Proteome:Evaluation of Cellular Protein Extraction Methods
7
作者 XU Xia QIN Weida +3 位作者 LI Ruomeng WANG Qianqian LIU Ning LI Gongyu 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2024年第11期98-107,共10页
The current study comprehensively evaluates four different protein extraction methods based on urea,sodium dodecyl sulfate(SDS),anionic surfactants(BT),and total RNA extractor(Trizol),aiming to optimize the sample pre... The current study comprehensively evaluates four different protein extraction methods based on urea,sodium dodecyl sulfate(SDS),anionic surfactants(BT),and total RNA extractor(Trizol),aiming to optimize the sample preparation workflow for mass spectrometry-based proteomics.Using HeLa cells as an example,we found that the method employing the mass spectrometry-compatible surfactant BT reagent significantly reduces the total time consumed for protein extraction and minimizes protein losses during the sample preparation process.Further integrating the four protein extraction methods,we identified over 7000 proteins from HeLa cells without relying on pre-fractionation techniques,and 2990 of them were quantified using label-free quantification.It is worth noting that the BT and SDS methods demonstrate higher efficiency in extracting membrane proteins,while the Urea and Trizol methods are more effective in extracting proteins from nuclear and cytoplasmic fractions.In summary,this study provides a novel solution for deep proteome coverage,particularly in the context of cellular protein extraction,by integrating mass spectrometry-compatible surfactants with traditional extraction methods to effectively enhance protein identification numbers. 展开更多
关键词 SURFACTANT Protein extraction PROTEOMICS mass spectrometry
下载PDF
Bacterial Protein Profiling——Comparison of Three Mass Spectrometry Methodologies
8
作者 JIANG Yan CHEN Yanlin +4 位作者 SONG Gaoyu CHEN Yanyan BAI Jing ZHU Yingdi LI Juan 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2024年第11期158-173,共16页
Profiling the protein composition of bacteria is essential for understanding their biology,physiology and interaction with environment.Mass spectrometry has become a pivotal tool for protein analysis,facilitating the ... Profiling the protein composition of bacteria is essential for understanding their biology,physiology and interaction with environment.Mass spectrometry has become a pivotal tool for protein analysis,facilitating the examination of expression levels,molecular masses and structural modifications.In this study,we compared the performance of three widely-used mass spectrometry methods,i.e.,matrix-assisted laser desorption/ionization(MALDI)protein fingerprinting,top-down proteomics and bottom-up proteomics,in the profiling of bacterial protein composition.It was revealed that bottom-up proteomics provided the highest protein coverage and exhibited the greatest protein profile overlap between bacterial species.In contrast,MALDI protein fingerprinting demonstrated superior detection reproducibility and effectiveness in distinguishing between bacterial species.Although top-down proteomics identified fewer proteins than bottom-up approach,it complemented MALDI fingerprinting in the discovery of bacterial protein markers,both favoring abundant,stable,and hydrophilic bacterial ribosomal proteins.This study represents the most systematic and comprehensive comparison of mass spectrometry-based protein profiling methodologies to date.It provides valuable guidelines for the selection of appropriate profiling strategies for specific analytical purposes.This will facilitate studies across various fields,including infection diagnosis,antimicrobial resistance detection and pharmaceutical target discovery. 展开更多
关键词 BACTERIA Protein profiling mass spectrometry
下载PDF
Determination of Ten Kinds of Alpha-2 Agonists Residues in Animal Derived Food by UHPLC-Triple Quadrupole/Composite Linear Ion Trap Mass Spectrometry
9
作者 Fang LI Xuemei LI +3 位作者 Xiangang LI Sining LIU Sha LIU Ying WANG 《Plant Diseases and Pests》 2024年第1期28-32,共5页
[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f... [Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food. 展开更多
关键词 Animal derived food α_(2)-receptor agonist Solid-phase extraction Ultra-high performance liquid phase-triple quadrupole/linear ion trap composite mass spectrometry
下载PDF
Research on the Upper Limit of Accuracy for Predicting Theoretical Tandem Mass Spectrometry
10
作者 Changjiu He Xiaoyu Wang +1 位作者 Mingming Lyu Xinye Bian 《Journal of Computer and Communications》 2024年第3期184-195,共12页
In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy... In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy of current methods approaches this limit, further exploration of new prediction techniques may become redundant. Conversely, a need for more precise prediction methods or models may be indicated. In this study, we have experimentally analyzed the limits of accuracy at different numbers of ions and parameters using repeated spectral pairs and integrating various similarity metrics. Results show significant achievements in accuracy for backbone ion methods with room for improvement. In contrast, full-spectrum prediction methods exhibit greater potential relative to the theoretical accuracy limit. Additionally, findings highlight the significant impact of normalized collision energy and instrument type on prediction accuracy, underscoring the importance of considering these factors in future theoretical tandem mass spectrometry predictions. 展开更多
关键词 Tandem mass spectrometry Spectral Prediction Theoretical Limit
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
11
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION spectrometry WITH on-line ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
Chemical Selectivity of Laser Ion Source for on-Line Mass Separator
12
作者 Zhao, Zhizheng Yang, Yongfeng +1 位作者 Cai, Xicheng Somerville, L.P. 《Chinese journal of nuclear physics》 EI 1997年第1期48-52,共5页
Thulium(Tm)atoms are resonantly ionized in a hot tube by stepwise excitations us-ing three dye lasers pumped by a series of copper vapor pulsed at a 10 kHz rate.The chemicalselectivity of the laser ion source is measu... Thulium(Tm)atoms are resonantly ionized in a hot tube by stepwise excitations us-ing three dye lasers pumped by a series of copper vapor pulsed at a 10 kHz rate.The chemicalselectivity of the laser ion source is measured as a function of temperature of the tubes made ofTa,Nb-Zr and TaC.The chemical selectivity rises from 50 to 10000 with decreasing tube temp-erature and strongly depends on the tube material.A chemical selectivity of about 10000 withhigh efficiencies is obtained with the Nb-Zr and TaC tubes.Such a laser ion source can be usedin on-line mass separator to obtain isobarically pure ion beams. 展开更多
关键词 Laser ION SOURCE Chemical SELECTIVITY on-line mass SEPARATOR
下载PDF
Determination on Heavy Metals Content of Achyranthes bidentata Blume. through Inductively Coupled Plasma Mass Spectrometry (ICP-MS) 被引量:4
13
作者 李宇伟 王新民 +3 位作者 连瑞丽 魏志华 介晓磊 陈士林 《Agricultural Science & Technology》 CAS 2008年第5期145-149,共5页
[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con... [Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places. 展开更多
关键词 MICROWAVE DIGESTION Inductively coupled plasma mass spectrometry(ICP-MS) Achyranthes bidentata Blume. HEAVY metal
下载PDF
Photoionization Mass Spectrometric and Kinetic Modeling of Low-pressure Pyrolysis of Benzene 被引量:2
14
作者 杨玖重 赵龙 +2 位作者 蔡江淮 齐飞 李玉阳 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2013年第3期245-251,I0003,共8页
Pyrolysis of benzene at 30 Torr was studied from 1360 K to 1820 K in this work. Synchrotron vacuum ultraviolet photoionization mass spectrometry was employed to detect the pyroly- sis products such as radicals, isomer... Pyrolysis of benzene at 30 Torr was studied from 1360 K to 1820 K in this work. Synchrotron vacuum ultraviolet photoionization mass spectrometry was employed to detect the pyroly- sis products such as radicals, isomers and polycyclic aromatic hydrocarbons, and measure their mole fraction profiles versus temperature. A low-pressure pyrolysis model of benzene was developed and validated by the experimental results. Rate of production analysis was performed to reveal the major reaction networks in both fuel decomposition and aromatic growth processes. It is concluded that benzene is mainly decomposed via H-abstraction reaction to produce phenyl and partly decomposed via unimolecular decomposition reac- tions to produce propargyl or phenyl. The decomposition process stops at the formation of acetylene and polyyne species like diacetylene and 1,3,5-hexatriyne due to their high thermal stabilities. Besides, the aromatic growth process in the low-pressure pyrolysis of benzene is concluded to initiate from benzene and phenyl, and is controlled by the even carbon growth mechanism due to the inhibited formation of C5 and C7 species which play important roles in the odd carbon growth mechanism. 展开更多
关键词 BENZENE Low-pressure pyrolysis PAH formation Synchrotron vacuum ultra-violet photoionization mass spectrometry Kinetic model
下载PDF
Separation of Ions from Volatile Organic Compounds Using High-Field Asymmetric Waveform Ion Mobility Spectrometry-Mass Spectrometer 被引量:2
15
作者 李华 王晓浩 +2 位作者 唐飞 杨吉 丁力 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第2期125-132,I0001,共9页
A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filte... A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized. 展开更多
关键词 High-field asymmetric waveform ion mobility spectrometry mass spectrometer Ion-filter Ion-molecular reaction Proton transfer
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
16
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 High performance liquid chromatography Electrospray ionization mass spectrometry Ginkgo terpene lactones
下载PDF
Study on Methanol Oxidation at Pt and PtRu Electrodes by Combining in situ Infrared Spectroscopy and Differential Electrochemical Mass Spectrometry 被引量:1
17
作者 陶骞 陈微 +2 位作者 姚瑶 Ammar Bin Yousaf 陈艳霞 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2014年第5期541-547,I0003,共8页
Methanol oxidation reaction (MOR) at Pt and Pt electrode surface deposited with various amounts of Ru (denoted as PtxRuy, nominal coverage y is 0.17, 0.27, and 0.44 ML) in 0.1 mol/L HClO4+0.5 mol/L MeOH has been ... Methanol oxidation reaction (MOR) at Pt and Pt electrode surface deposited with various amounts of Ru (denoted as PtxRuy, nominal coverage y is 0.17, 0.27, and 0.44 ML) in 0.1 mol/L HClO4+0.5 mol/L MeOH has been studied under potentiostatic conditions by in situ FTIR spectroscopy in attenuated-total-reflection con guration and di erential electro-chemical mass spectrometry under controlled flow conditions. Results reveal that (i) CO is the only methanol-related adsorbate observed by IR spectroscopy at all the Pt and PtRu electrodes examined at potentials from 0.3 V to 0.6 V (vs. RHE); (ii) at Pt0.56Ru0.44, two IR bands, one from CO adsorbed at Ru islands and the other from COL at Pt substrate are detected, while at other electrodes, only a single band for COL adsorbed at Pt is observed; (iii) MOR activity decreases in the order of Pt0.73Ru0.27〉Pt0.56Ru0.44〉Pt0.83Ru0.17〉Pt; (iv) at 0.5 V, MOR at Pt0.73Ru0.27 reaches a current e ciency of 50% for CO2 production, the turn-over frequency from CH3OH to CO2 is ca. 0.1 molecule/(site sec). Suggestions for further improving of PtRu catalysts for MOR are provided. 展开更多
关键词 Differential electrochemical mass spectrometry Electrochemical in situ infrared spectroscopy Methanol oxidation PtRu electrode Current efficiency
下载PDF
Oxidation of Carbon Supports at Fuel Cell Cathodes: Differential Electrochemical Mass Spectrometric Study
18
作者 李明芳 陶骞 +3 位作者 廖玲文 徐杰 蔡俊 陈艳霞 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第4期442-446,I0002,共6页
The effects of O2 and the supported Pt nano-particles on the mechanisms and kinetics of the carbon support corrosion are investigated by monitoring the CO2 production using differential electrochemical mass spectromet... The effects of O2 and the supported Pt nano-particles on the mechanisms and kinetics of the carbon support corrosion are investigated by monitoring the CO2 production using differential electrochemical mass spectrometry in a dual-thin layer flow cell. Carbon can be oxidized in different distinct potential regimes; O2 accelerates carbon oxidation, the rates of CO2 production from carbon oxidation in O2 saturated solution are two times of that in N2 saturated solution at the same potential; Pt can catalyze the carbon oxidation, with supported Pt nanoparticles, the overpotential for carbon oxidation is much smaller than that without loading in the carbon electrode. The mechanism for the enhanced carbon oxidation by Pt and O2 are discussed. 展开更多
关键词 Carbon corrosion Pt Fuel cell cathode Differential electrochemical mass spectrometry
下载PDF
Pyrolysis-Gas Chromatography/Mass Spectrometry for Microstructure and Pyrolysis Pathway of Polyester-Polyether Multiblock Copolymer
19
作者 罗爱芹 叶玲 +2 位作者 傅若农 谢桂阳 王显伦 《Journal of Beijing Institute of Technology》 EI CAS 2001年第1期45-50,共6页
The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/M... The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/MS). PGC was applied to study the F t curve of the multiblock copolymer and PGC/MS was used to separate and identify the pyrolyzates. DTA experiment was used to study the decomposition temperature. The results show that the beginning point of elastomer’s decomposition was about 300?℃ and the decomposition temperature of most of the sample was 550?℃. Many pyrolyzates were produced because of the breaking of weak bonds in the sample. The possible microstructure was verified and the pyrolysis pathway of the copolymer was investigated. 展开更多
关键词 thermoplastic elastomer polyester polyether multiblock copolymer pyrolysis gas chromatography/mass spectrometry copolymer pyrolysis pathway MICROSTRUCTURE pyrolyzates
下载PDF
Product Identification and Mass Spectrometric Analysis of n-Butane and i-Butane Pyrolysis at Low Pressure 被引量:1
20
作者 张义军 苑文浩 +3 位作者 蔡江淮 张李东 齐飞 李玉阳 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2013年第2期151-156,I0003,共7页
The pyrolysis of n-butane and i-butane at low pressure was investigated from 823-1823 K in an electrically heated flow reactor using synchrotron vacuum ultraviolet photoionization mass spectrometry. More than 20 speci... The pyrolysis of n-butane and i-butane at low pressure was investigated from 823-1823 K in an electrically heated flow reactor using synchrotron vacuum ultraviolet photoionization mass spectrometry. More than 20 species, especially several radicals and isomers, were detected and identified from the measurements of photoionization efficiency (PIE) spectra. Based on the mass spectrometric analysis, the characteristics of n-butane and i-butane pyrolysis were discussed, which provided experimental evidences for the discussion of decomposition pathways of butane isomers. It is concluded that the isomeric structures of n-butane and i-butane have strong influence on their main decomposition pathways, and lead to dramatic differences in their mass spectra and PIE spectra such as the different dominant products and isomeric structures of butene products. Furthermore, compared with n-butane,i-butane can produce strong signals of benzene at low temperature in its pyrolysis due to the enhanced formation of benzene precursors like propargyl and C4 species, which provides experimental clues to explain the higher sooting tendencies of iso-alkanes than n-alkanes. 展开更多
关键词 N-BUTANE /-Butane Flow reactor pyrolysis Synchrotron vacuum ultravioletphotoionization mass spectrometry Product identification mass spectrometric analysis
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部