期刊文献+
共找到312,384篇文章
< 1 2 250 >
每页显示 20 50 100
On-Line Measurement of the Chemical Oxygen Demand in Wastewater in a Pulp and Paper Mill Using Near Infrared Spectroscopy 被引量:5
1
作者 John Dahlbacka Josefina Nystrom +2 位作者 Torgny Mossing Paul Geladi Tom Lillhonga 《Spectral Analysis Review》 2014年第4期19-25,共7页
Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts... Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy. 展开更多
关键词 Chemical Oxygen Demand (COD) Industrial Wastewater Near Infrared Spectroscopy (NIR) Multivariate Calibration on-line measurement
下载PDF
On-line Measurement of Water-Soluble Ions in Ambient Particles 被引量:5
2
作者 温天雪 王跃思 +1 位作者 张士昱 刘广仁 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2006年第4期586-592,共7页
Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-lin... Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-line the concentrations of water-soluble ions in ambient particles. Here, the general scheme of RCFP-IC is described and its basic performance is tested. The detection limit of RCFP-IC for SO4^2-, NO3^-, NO2^-, Cl^- and F- is below 0.3μg m^-3. The collection efficiency of RCFP-IC increases rapidly with increasing sized particles. For particles larger than 300 nm, the collection efficiency approaches 100%. The precision of RCFP-IC is more than 90% over 28 repetitions. The response of RCFP-IC is very sensitive and no obvious cross-pollution is found during measurement. A comparison of RCFP-IC with an integrated filter measurement indicates that the measurement of RCFP-IC is comparable in both laboratory experiments and field observations. The results of the field experiment prove that RCFP-IC is an effective on-line monitoring system and is helpful in source apportionment and pollution episode monitoring. 展开更多
关键词 RCFP-IC water-soluble ions on-line basic performance field observation
下载PDF
A METHOD OF ON-LINE MEASUREMENT FOR THE FREQUENCY RESPONSE AND IMPULSE RESPONSE FUNCTIONS OF MULTIVARIATE SYSTEM
3
作者 汪凤泉 韩晓林 吴慧新 《Journal of Southeast University(English Edition)》 EI CAS 1993年第1期95-101,共7页
In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capa... In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capacity of therestraint to the identification error caused by the non-random D.C.drift of the mul-ti-input excitation with the ORRS in the multivariate system is also discussed.Thevalidity of the method described in this paper is proved by the modelling tests of themulti-plate rotor system. 展开更多
关键词 on-line identification multi-point EXCITATION ORTHOGONAL reciprocal repeated SEQUENCE VIBRATION measurement
下载PDF
On-line measurement of electrical variables of the transducer during ultrasonic welding and cutting
4
作者 闫久春 刘井权 杨士勤 《China Welding》 EI CAS 2002年第2期133-137,共5页
A measurement system for high power electrical variables with ultrasonic frequency was established. It can measure the effective values of the voltage and the current, the active power, the phase difference of voltage... A measurement system for high power electrical variables with ultrasonic frequency was established. It can measure the effective values of the voltage and the current, the active power, the phase difference of voltage and current, the frequency of the transducer during ultrasonic welding and cutting. In sampling circuits of the system, the measured current is sensed by using a no capacitance and no inductance precision resistor and is treated with a difference amplifier, the measured voltage is processed by using a proportional amplifier. For achieving good amplitude frequency characteristics and rapid measurement of high frequency signals, the resistors, capacitors and amplifiers used in the system are rationally selected. Calibrating experiments show that relative errors are less than 1% for voltage and current effective values and less than 2.5% for active power, and absolute errors are ±1 Hz for frequency and ±1.7° for phase difference of voltage and current in the range of 17~23 kHz . 展开更多
关键词 ultrasonic welding ultrasonic cutting on line measurement electrical variables
下载PDF
Novel Optical Fiber Gas Sensor for On-line Measurement of Methane
5
作者 WANGShu-tao CHERen-sheng +1 位作者 LIUJin WANGYu-tian 《Semiconductor Photonics and Technology》 CAS 2004年第2期141-144,共4页
Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measu... Based on analysis of near infrared spectral absorption of methane,absorption type optical fiber methane gas sensor with high sensitivity using DFB LD as a source is demonstrated. Light source modulation harmonic measurement is presented in this paper. In order to eliminate the noise, the ratio of the fundamental and second-harmonic signals is used. The mathematical model of gas concentration harmonic measurement is built up.The detection result of methane concentration is also shown. Experiments have proved a sensitivity of 28×10-6. 展开更多
关键词 气敏传感器 在线测量 甲烷 光纤
下载PDF
Development of an on-line measurement system for water-soluble organic matter in PM_(2.5) and its application in China 被引量:5
6
作者 Huiying Li Xiaofeng Huang +3 位作者 Liming Cao Yuhong Zhai Liwu Zeng Lingyan He 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第7期33-40,共8页
Water-soluble organic matter(WSOM) represents a critical fraction of fine particles(PM2.5)in the air, but its changing behaviors and formation mechanisms are not well understood yet, partly due to the lack of fast... Water-soluble organic matter(WSOM) represents a critical fraction of fine particles(PM2.5)in the air, but its changing behaviors and formation mechanisms are not well understood yet, partly due to the lack of fast techniques for the ambient measurements. In this study,a novel system for the on-line measurement of water-soluble components in PM2.5, the particle-into-liquid sampler(PILS)–Nebulizer–aerosol chemical speciation monitor(ACSM), was developed by combining a PILS, a nebulizer, and an ACSM. High time resolution concentrations of WSOM, sulfate, nitrate, ammonium, and chloride, as well as mass spectra, can be obtained with satisfied quality control results. The system was firstly applied in China for field measurement of WSOM. The mass spectrum of WSOM was found to resemble that of oxygenated organic aerosol, and WSOM agreed well with secondary inorganic ions. All evidence collected in the field campaign demonstrated that WSOM could be a good surrogate of secondary organic aerosol(SOA). The PILS–Nebulizer–ACSM system can thus be a useful tool for intensive study of WSOM and SOA in PM2.5. 展开更多
关键词 PM2.5 Water-soluble organic matter Secondary organic matter on-line measurement Mass spectrum
原文传递
On-Line Measurement Method for Diameter and Roundness Error of Balls 被引量:4
7
作者 Yindi Cai Bo Xie +1 位作者 Siying Ling Kuang-Chao Fan 《Nanomanufacturing and Metrology》 2020年第3期218-227,共10页
This paper presents an on-line measurement method for the diameter and roundness error of balls.An easy-installation rotary scanning system,which integrates the principles of the diameter and the roundness measurement... This paper presents an on-line measurement method for the diameter and roundness error of balls.An easy-installation rotary scanning system,which integrates the principles of the diameter and the roundness measurements,is constructed.The rotary scanning system consists of a rotary stage,a linear stage,and two sensors with a什at probe.Two sensors are initially installed on the linear stage and contact each other.The outputs of two sensors are reset to zero at first.The ball is then mounted on the rotary stage and positioned between two flat probes.The variations of the diameter and the roundness error of the ball at each angular position can be directly recorded by two sensors when the ball is rotated by the rotary stage.Substituting the outputs of two sensors into the proposed mathematical models,the diameter and roundness error can be evaluated.The effects of the alignment error induced by the spindle error of the rotary stage and the titling error and the eccentric error of the ball on the measurement accuracy can be self-separated in the proposed on-line measurement method.A series of experiments are carried out to verify the effectiveness and the capability of the proposed on-line measurement method and the designed rotary scanning system.The designed system is easy to construct both in the laboratory environment and the factory field. 展开更多
关键词 on-line measurement DIAMETER Roundness error Alignment error
原文传递
STRONGLY CONVERGENT INERTIAL FORWARD-BACKWARD-FORWARD ALGORITHM WITHOUT ON-LINE RULE FOR VARIATIONAL INEQUALITIES
8
作者 姚永红 Abubakar ADAMU Yekini SHEHU 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期551-566,共16页
This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti... This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature. 展开更多
关键词 forward-backward-forward algorithm inertial extrapolation variational inequality on-line rule
下载PDF
Bunch-length measurement at a bunch-by-bunch rate based on time–frequency-domain joint analysis techniques and its application
9
作者 Hong-Shuang Wang Xing Yang +2 位作者 Yong-Bin Leng Yi-Mei Zhou Ji-Gang Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期165-175,共11页
This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si... This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings. 展开更多
关键词 Bunch-by-bunch diagnostic Bunch-length measurement Synchronous phase measurement Joint time–frequency-domain analysis Longitudinal instability
下载PDF
Enhancing Energy Efficiency with a Dynamic Trust Measurement Scheme in Power Distribution Network
10
作者 Yilei Wang Xin Sun +4 位作者 Guiping Zheng Ahmar Rashid Sami Ullah Hisham Alasmary Muhammad Waqas 《Computers, Materials & Continua》 SCIE EI 2024年第3期3909-3927,共19页
The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the e... The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the edge convergence layer and the end sensing layer,with the former using intelligent fusion terminals for real-time data collection and processing.However,the influx of multiple low-voltage in the smart grid raises higher demands for the performance,energy efficiency,and response speed of the substation fusion terminals.Simultaneously,it brings significant security risks to the entire distribution substation,posing a major challenge to the smart grid.In response to these challenges,a proposed dynamic and energy-efficient trust measurement scheme for smart grids aims to address these issues.The scheme begins by establishing a hierarchical trust measurement model,elucidating the trust relationships among smart IoT terminals.It then incorporates multidimensional measurement factors,encompassing static environmental factors,dynamic behaviors,and energy states.This comprehensive approach reduces the impact of subjective factors on trust measurements.Additionally,the scheme incorporates a detection process designed for identifying malicious low-voltage end sensing units,ensuring the prompt identification and elimination of any malicious terminals.This,in turn,enhances the security and reliability of the smart grid environment.The effectiveness of the proposed scheme in pinpointing malicious nodes has been demonstrated through simulation experiments.Notably,the scheme outperforms established trust metric models in terms of energy efficiency,showcasing its significant contribution to the field. 展开更多
关键词 IIoT trusted measure energy efficient
下载PDF
Measuring small longitudinal phase shifts via weak measurement amplification
11
作者 徐凯 胡晓敏 +7 位作者 胡孟军 王宁宁 张超 黄运锋 柳必恒 李传锋 郭光灿 张永生 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期105-111,共7页
Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted ... Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection. 展开更多
关键词 weak measurement phase estimation quantum optics
下载PDF
Improved spatio-temporal alignment measurement method for hull deformation
12
作者 XU Dongsheng YU Yuanjin +1 位作者 ZHANG Xiaoli PENG Xiafu 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第2期485-494,共10页
In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Lar... In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Large misalignment angle and time delay often occur simultaneously and bring great challenges to the accurate measurement of hull deformation in space and time.The proposed method utilizes coarse alignment with large misalignment angle and time delay estimation of inertial measurement unit modeling to establish a brand-new spatiotemporal aligned hull deformation measurement model.In addition,two-step loop control is designed to ensure the accurate description of dynamic deformation angle and static deformation angle by the time-space alignment method of hull deformation.The experiments illustrate that the proposed method can effectively measure the hull deformation angle when time delay and large misalignment angle coexist. 展开更多
关键词 inertial measurement spatio-temporal alignment hull deformation
下载PDF
Design and application of thickness measurement calibration system based on laser displacement sensor
13
作者 SUN Jin YU Zijin 《Baosteel Technical Research》 CAS 2024年第2期39-46,共8页
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th... This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing. 展开更多
关键词 steel plate thickness high precision measurement noncontact thickness measurement laser displace-ment sensor
下载PDF
A seismic elastic moduli module for the measurements of low-frequency wave dispersion and attenuation of fluid-saturated rocks under different pressures
14
作者 Yan-Xiao He Shang-Xu Wang +9 位作者 Gen-Yang Tang Chao Sun Hong-Bing Li San-Yi Yuan Xian Wei Li-Deng Gan Xiao-Feng Dai Qiang Ge Peng-Peng Wei Hui-Qing Zhang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期162-181,共20页
Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and... Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and time-lapse seismic surveillance of both conventional and unconventional reservoir and overburden performances.A Seismic Elastic Moduli Module has been developed,based on the forced-oscillations method,to experimentally investigate the frequency dependence of Young's modulus and Poisson's ratio,as well as the inferred attenuation,of cylindrical samples under different confining pressure conditions.Calibration with three standard samples showed that the measured elastic moduli were consistent with the published data,indicating that the new apparatus can operate reliably over a wide frequency range of f∈[1-2000,10^(6)]Hz.The Young's modulus and Poisson's ratio of the shale and the tight sandstone samples were measured under axial stress oscillations to assess the frequency-and pressure-dependent effects.Under dry condition,both samples appear to be nearly frequency independent,with weak pressure dependence for the shale and significant pressure dependence for the sandstone.In particular,it was found that the tight sandstone with complex pore microstructure exhibited apparent dispersion and attenuation under brine or glycerin saturation conditions,the levels of which were strongly influenced by the increased effective pressure.In addition,the measured Young's moduli results were compared with the theoretical predictions from a scaled poroelastic model with a reasonably good agreement,revealing that the combined fluid flow mechanisms at both mesoscopic and microscopic scales possibly responsible for the measured dispersion. 展开更多
关键词 Low-frequency measurements Dispersion and attenuation Rock physics Fluid flow
下载PDF
A fast forward computational method for nuclear measurement using volumetric detection constraints
15
作者 Qiong Zhang Lin-Lv Lin 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期47-63,共17页
Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sour... Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sources,the detector response can reflect various types of information of the medium.The Monte Carlo method is one of the primary methods used to obtain nuclear detection responses in complex environments.However,this requires a computational process with extensive random sampling,consumes considerable resources,and does not provide real-time response results.Therefore,a novel fast forward computational method(FFCM)for nuclear measurement that uses volumetric detection constraints to rapidly calculate the detector response in various complex environments is proposed.First,the data library required for the FFCM is built by collecting the detection volume,detector counts,and flux sensitivity functions through a Monte Carlo simulation.Then,based on perturbation theory and the Rytov approximation,a model for the detector response is derived using the flux sensitivity function method and a one-group diffusion model.The environmental perturbation is constrained to optimize the model according to the tool structure and the impact of the formation and borehole within the effective detection volume.Finally,the method is applied to a neutron porosity tool for verification.In various complex simulation environments,the maximum relative error between the calculated porosity results of Monte Carlo and FFCM was 6.80%,with a rootmean-square error of 0.62 p.u.In field well applications,the formation porosity model obtained using FFCM was in good agreement with the model obtained by interpreters,which demonstrates the validity and accuracy of the proposed method. 展开更多
关键词 Nuclear measurement Fast forward computation Volumetric constraints
下载PDF
Fast compressed sensing spectral measurement with adaptive gradient multiscale resolution
16
作者 蓝若明 刘雪峰 +1 位作者 李天平 白成杰 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期298-304,共7页
We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement ti... We propose a fast,adaptive multiscale resolution spectral measurement method based on compressed sensing.The method can apply variable measurement resolution over the entire spectral range to reduce the measurement time by over 75%compared to a global high-resolution measurement.Mimicking the characteristics of the human retina system,the resolution distribution follows the principle of gradually decreasing.The system allows the spectral peaks of interest to be captured dynamically or to be specified a priori by a user.The system was tested by measuring single and dual spectral peaks,and the results of spectral peaks are consistent with those of global high-resolution measurements. 展开更多
关键词 SPECTROMETER compressed sensing adaptive gradient multiscale resolution fast measurement
下载PDF
Finesse measurement for high-power optical enhancement cavity
17
作者 陆心怡 柳兴 +3 位作者 田其立 王焕 汪嘉俊 颜立新 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期414-421,共8页
Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the a... Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the advantages, disadvantages, and potential limitations of several main methods from both theoretical and practical perspectives. A variant of the existing method called the free spectral range(FSR) modulation method is proposed and compared with three other finesse measurement methods, i.e., the fast-switching cavity ring-down(CRD) method, the rapidly swept-frequency(SF) CRD method, and the ringing effect method. A high-power OEC platform with a high finesse of approximately 16000 is built and measured with the four methods. The performance of these methods is compared, and the results show that the FSR modulation method and the fast-switching CRD method are more suitable and accurate than the other two methods for high-finesse OEC measurements. The CRD method and the ringing effect method can be implemented in open loop using simple equipment and are easy to perform. Additionally, recommendations for selecting finesse measurement methods under different conditions are proposed, which benefit the development of OEC and its applications. 展开更多
关键词 optical enhancement cavity finesse measurement cavity ring-down ringing effect
下载PDF
Initial measurement of ultrafast charge exchange recombination spectroscopy on the EAST tokamak
18
作者 蒋军 李颖颖 +5 位作者 陈冉 符佳 吕波 余羿 徐国盛 叶民友 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期40-46,共7页
Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here... Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here,we report the preliminary diagnostic measurements after relative sensitivity calibration.The measurement results show a much higher temporal resolution compared with conventional CXRS,benefiting from the usage of a prismcoupled,high-dispersion volume-phase holographic transmission grating and a high quantum efficiency,high-gain detector array.Utilizing the UF-CXRS diagnostic,the fast evolutions of the ion temperature and rotation velocity during a set of high-frequency small-amplitude edgelocalized modes(ELMs)are obtained on the EAST tokamak,which are then compared with the case of large-amplitude ELMs. 展开更多
关键词 ultrafast charge exchange recombination spectroscopy EAST diagnostic measurements
下载PDF
Statistical Channel Modeling for Indoor VLC Communications Based on Channel Measurements
19
作者 Shuo Liu Pan Tang +5 位作者 Jianhua Zhang Yue Yin Yu Tong Baobao Liu Guangyi Liu Liang Xia 《China Communications》 SCIE CSCD 2024年第1期131-147,共17页
Visible light communication(VLC)has attracted much attention in the research of sixthgeneration(6G)systems.Furthermore,channel modeling is the foundation for designing efficient and robust VLC systems.In this paper,we... Visible light communication(VLC)has attracted much attention in the research of sixthgeneration(6G)systems.Furthermore,channel modeling is the foundation for designing efficient and robust VLC systems.In this paper,we present extensive VLC channel measurement campaigns in indoor environments,i.e.,an office and a corridor.Based on the measured data,the large-scale fading characteristics and multipath-related characteristics,including omnidirectional optical path loss(OPL),K-factor,power angular spectrum(PAS),angle spread(AS),and clustering characteristics,are analyzed and modeled through a statistical method.Based on the extracted statistics of the above-mentioned channel characteristics,we propose a statistical spatial channel model(SSCM)capable of modeling multipath in the spatial domain.Furthermore,the simulated statistics of the proposed model are compared with the measured statistics.For instance,in the office,the simulated path loss exponent(PLE)and the measured PLE are 1.96and 1.97,respectively.And,the simulated medians of AS and measured medians of AS are 25.94°and 24.84°,respectively.Generally,the fact that the simulated results fit well with measured results has demonstrated the accuracy of our SSCM. 展开更多
关键词 channel characteristics channel measurement channel modeling 6G spatial lobe VLC
下载PDF
Non-Kramers doublet ground state in a quaternary cubic compound PrRu_(2)In_(2)Zn_(18) investigated by ultrasonic measurements
20
作者 张化远 Kazuhei Wakiya +2 位作者 Mitsuteru Nakamura Masahito Yoshizawa Yoshiki Nakanish 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第6期405-411,共7页
We performed ultrasonic measurements on a quaternary cubic compound PrRu_(2)In_(2)Zn_(18) to explore the ground state properties derived from non-Kramers Γ_(3) doublet of Pr^(3+).PrRu_(2)In_(2)Zn_(18) is a quaternary... We performed ultrasonic measurements on a quaternary cubic compound PrRu_(2)In_(2)Zn_(18) to explore the ground state properties derived from non-Kramers Γ_(3) doublet of Pr^(3+).PrRu_(2)In_(2)Zn_(18) is a quaternary derivative of the ternary compound PrRu_(2)Zn_(20) that exhibits a structural phase transition at T_S=138 K.In PrRu_(2)In_(2)Zn_(18),the Zn atoms at the 16c site in PrRu_(2)Zn_(20) are selectively replaced by In atoms.A monotonic increase was observed in the temperature dependence of elastic constants C_L=(C_(11)+2C_(12)+4C_(44))/3 and C_(T)=(C_(11)-C_(12)+C_(44))/3 in the temperature range around T_(S) to which an elastic softening was observed in(C_(11)-C_(12))/2 for PrRu_(2)Zn_(20).The disappearance of the softening indicates that the structural transition in PrRu_(2)Zn_(20) is suppressed by the substitution of Zn ions by In ones with a larger ionic radius.Alternatively,the C_(T) of PrRu_(2)In_(2)Zn_(18) exhibits a precursor Curie-type elastic softening toward low temperatures being responsible for the non-Kramers Γ_(3) ground state.We discuss the ground state and the evolution of the elastic properties of the different single-crystal samples of PrRu_(2)In_(2)Zn_(18) grown under different conditions. 展开更多
关键词 ultrasonic measurements non-Kramers doublet structural phase transition crystalline electric field effect
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部