A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filterin...A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents.展开更多
The method using pulsed eddy currents to determine the thickness of a conduction plate is extended to enable the simultaneous measurement of the plate thickness and material properties. For optimal performance, a prob...The method using pulsed eddy currents to determine the thickness of a conduction plate is extended to enable the simultaneous measurement of the plate thickness and material properties. For optimal performance, a probe must be designed depending on the thickness range that should be accessible. The need for a calibration of the material properties of a conducting plate to enable the measurement of its thickness has been removed. All that is needed is a probe with known dimensions and suitable hardware to create a current pulse and measure a transient magnetic induction.展开更多
Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz...Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.展开更多
Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic nois...Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic noise level of measuring instruments.This leads to the need for multiple measurements with subsequent statistical processing.In this paper,the digital algorithms are proposed for the automatic measurement of the JJ parameters by IVC.These algorithms make it possible to implement multiple measurements and check these JJ parameters in an automatic mode with the required accuracy.The complete sufficient statistics are used to minimize the root-mean-square error of parameter measurement.A sequence of current pulses with slow rising and falling edges is used to drive JJ,and synchronous current and voltage readings at JJ are used to realize measurement algorithms.The algorithm performance is estimated through computer simulations.The significant advantage of the proposed algorithms is the independence from current source noise and intrinsic noise of current and voltage meters,as well as the simple implementation in automatic digital measuring systems.The proposed algorithms can be used to control JJ parameters during mass production of superconducting integrated circuits,which will improve the production efficiency and product quality.展开更多
It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate t...It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate testing signals.This speed measurement method is complicated,and inevitable abrasion and occasional slippage will reduce the measurement accuracy.In order to solve this problem,based on eddy current effect due to the relative movement,a speed measurement method is proposed,which is contactless and simple.In the high-speed MFL testing,eddy current induced in the specimen will cause an obvious modification to the applied field.This modified field,which is measured by Hall sensor,can be utilized to reflect the moving speed.Firstly,the measurement principle is illustrated based on Faraday’s law.Then,dynamic finite element simulations are conducted to investigate the modified magnetic field distribution.Finally,laboratory experiments are performed to validate the feasibility of the proposed method.The results show that Bmz(r1)and Bmx(r2)have a linear relation with moving speed,which could be used as an alternative measurement parameter.展开更多
Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts...Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy.展开更多
In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capa...In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capacity of therestraint to the identification error caused by the non-random D.C.drift of the mul-ti-input excitation with the ORRS in the multivariate system is also discussed.Thevalidity of the method described in this paper is proved by the modelling tests of themulti-plate rotor system.展开更多
A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put fo...A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put forward here. The design and some experimental results are given.展开更多
A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field duri...A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation.展开更多
Direct measurements of current velocity and water temperature were undertaken at the mooring Sta. M (125°29.38' N, 31°49.70' E) on the continental shelf area in the East China Sea in June 1999 by R/V...Direct measurements of current velocity and water temperature were undertaken at the mooring Sta. M (125°29.38' N, 31°49.70' E) on the continental shelf area in the East China Sea in June 1999 by R/V Xiangyanghong 14. The relationship between various time series of oceanic fluctuations is calculated by spectral analysis. The major results are as follows: (1) an average (u,v) of (6.9,-3.0 cm/s) at the 30 m depth is obtained during the 9-day observation, and that at the 45 m depth is (3.7,-1.1 cm/s), i. e., the mean flows are southeastward at both the 30 and 45 m depths;the currents become stronger gradually during the observation period; this may be mainly attributed to the transition of the tidal currents from neap to spring; (2)semidiurnal fluctuation is the most dominant in the current fluctuations, and rotates mainly clockwise; in the next place, there is also diurnal fluctuation;the local inertial period is close to the period of diurnal fluctuation, and an inertial motion is clockwise; thus, local inertial motion combines with diurnal fluctuation, and makes the spectral peaks in clockwise components much higher than those in counterclockwise ones; except for the fluctuations of above main periods, there is also the peak at 3 d period for counterclockwise compo-nents in the upper and lower layers; (3) the calculation of cross spectra between two time series of current velocities at the 30 and 45 m depths shows that both the current fluctuations at the 30 and 45 m depths are much alike, i. e., they are synchro; this shows that the flow field here is rather vertically homogeneous; (4)power spectra of tempera-ture time series at both the 30 and 45 m depths show that the semidiurnal peak is the most predominant, and the second highest peak is the diurnal period; besides spectral peaks at above periods, there are also obvious spectral peaks at 6.8 h and 2 d; (5)plots of temperature time series at 16 , 30 , 35 , 45 and 50 m depths show that the temporal variations of temperature at these depths are synchro, which are like those in the velocity field; temperature records also show a gradual rise in temperature, which are also like those in the velocity field.展开更多
In eddy current testing, the law of attenuation of eddy current(EC) is of great concern. In conductive half space under the excitation of uniform magnetic field, the EC density decreases exponentially in the depth dir...In eddy current testing, the law of attenuation of eddy current(EC) is of great concern. In conductive half space under the excitation of uniform magnetic field, the EC density decreases exponentially in the depth direction. However, in conductor with finite thickness tested by coil, the distribution of EC in the depth direction is more complicated. This paper studies the characteristics of EC attenuation in metallic plate of finite thickness. Simulation results show that there is an EC reflection at the bottom of plate, which changes the law of EC attenuation. A new concept, namely the equivalent attenuation coefficient, is proposed to quantify the speed of EC attenuation. The characteristics of EC attenuation are utilized to explain the nonmonotonic relation between coil voltage and plate thickness. Procedure of selecting frequency is discussed. Thereafter, measurement of plate thickness is carried out and accurate result is obtained.展开更多
With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the uns...With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the unstable operating conditions brought by flexible operation.A vibration measuring method for the shrouded blades of a steam turbine based on eddy current sensors with high frequency response is proposed,meeting the requirements of non-contact heath monitoring.The eddy current sensors produce the signals which are related to the area changing of every blade’s shroud resulting from the rotation of stator.Then an improved blade tip timing(BTT)technique is proposed to detect the vibrations of shrouded blades by measuring the arrival time of each area changing signal.A structure of eddy current sensors is developed in steam turbines and an amplitude modulation/demodulation circuit is designed to improve the response bandwidth up to 250 kHz.Vibration tests for the last stage blades of a steam turbine were carried out and the results validate the efficiency of the improved BTT technique and the high frequency response of the eddy current sensors presented.展开更多
Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive mo...Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive model for errors calculation in an on-line measuring System of machining center have been built for the first time. Using this model, the errors can be compensated by soft.ware and the measuring accuracy can be enhanced without any more inveSt. This model can be used in all kinds of machining center.展开更多
Luquire et al. ' s impedance change model of a rectangular cross section probe coil above a structure with an arbitrary number of parallel layers was used to study the principle of measuring thicknesses of multi-l...Luquire et al. ' s impedance change model of a rectangular cross section probe coil above a structure with an arbitrary number of parallel layers was used to study the principle of measuring thicknesses of multi-layered structures in terms of eddy current testing voltage measurements. An experimental system for multi-layered thickness measurement was developed and several fitting models to formulate the relationships between detected impedance/voltage measurements and thickness are put forward using least square method. The determination of multi-layered thicknesses was investigated after inversing the voltage outputs of the detecting system. The best fitting and inversion models are presented.展开更多
Objective: To quantitatively identify and grade trigeminal sensory functions after 3 major surgical procedures of trigeminal neuralgia using a newly developed quantitative sensory testing technique, current perceptio...Objective: To quantitatively identify and grade trigeminal sensory functions after 3 major surgical procedures of trigeminal neuralgia using a newly developed quantitative sensory testing technique, current perception threshold measurement (CPTM). Methods: In the current study, there were 48 trigeminal neuralgia patients without history of prior surgical treatment. These patients received one of the following 3 surgical procedures, microvascular decompression (MVD), peripheral nerve block with alcohol (PNB), or percutaneous radiofrequency thermocoagulation (PRFT). The quantitative sensory testing measurement, CPTM, and conventional qualitative sensory testing measurements were performed preoperatively and postoperatively to evaluate and grade the trigeminal sensory functions All 3 major cutaneous sensory fiber types, large myelinated fibers (A beta), small myelinated fibers (A delta) and unmyelinated fibers(C) were allowed to quantitatively evaluate and grade by CPTM. The results of the measurements were statistically analyzed using a one-way analysis of variance (single factor). Each subject was his/her own control for comparison of the preoperative to postoperative state on the asymptomatic and symptomatic sides. Subjects were tested 48 h preoperatively and 4 weeks postoperatively. Results: PNB with alcohol and PRFT caused significant sensory dysfunction postoperatively in every fiber type, indicating damage to all fibers. On the contrary, the sensory function in all 3 fiber types was unchanged after MVD management. Conclusion: Among the 3 major surgical procedures tested, only MVD preserves sensory function in trigeminal system. CPTM is of quantitative nature on the evaluation of sensory functions of nerve fibers展开更多
On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real tim...On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real time.Here we describe the development and application of an automatic measurement system that incorporates PM_(2.5)sampling,thermal desorption,atmospheric pressure photoionization,and UHRMS analysis.Molecular formulas of detected organic compounds were deducted from the accurate(±10 ppm)molecular weights obtained at a mass resolution of 100,000,allowing the identification of small organic compounds in PM_(2.5).Detection efficiencies of 28 standard compounds were determined and we found a high sensitivity and selectivity towards organic amines with limits of detection below 10 pg.As a proof of principle,PM_(2.5)samples collected off-line in winter in the urban area of Beijing were analyzed using the Ionization Module and HRMS of the system.The automatic system was then applied to conduct on-line measurements during the summer time at a time resolution of 2 hr.The detected organic compounds comprised mainly CHON and CHN compounds below 350 m/z.Pronounced seasonal variations in elemental composition were observed with shorter carbon backbones and higher O/C ratios in summer than that in winter.This result is consistent with stronger photochemical reactions and thus a higher oxidation state of organics in summer.Diurnal variation in signal intensity of each formula provides crucial information to reveal its source and formation pathway.In summary,the automatic measurement system serves as an important tool for the on-line characterization and identification of organic species in PM_(2.5).展开更多
Magnetic sensor arrays are proposed to measure electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. Simulation techniques ar...Magnetic sensor arrays are proposed to measure electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. Simulation techniques are necessary to study the factors influencing the accuracy of current measurement. This paper presents a simulation method to estimate the impact of sensing area and position of sensors on the accuracy of current measurement. Several error models are built up to support computer-aided design of magnetic sensor arrays.展开更多
A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Performance tests show that the Rogowski coil ...A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Performance tests show that the Rogowski coil has both excellent dynamic and static characteristics. Calibrating results and the comparison between the standard current shunt and the developed Rogowski coil for the measurement of nanosecond discharge pulses demonstrate that the developed Rogowski coil can reproduce the actual waveform of the discharge current accurately.展开更多
The plasma current is modulated with an alternating current (ac) component in a frequency range of 90 Hz - 900 Hz in the plateau discharge phase in the CT-6B tokamak. A plasma electric conductivity profile in a form...The plasma current is modulated with an alternating current (ac) component in a frequency range of 90 Hz - 900 Hz in the plateau discharge phase in the CT-6B tokamak. A plasma electric conductivity profile in a form of (1 - r^2/a^2)^α with a parameter α which is fitted with the experimental data, can be determined. The effects of magnetic shear in a tokamak field configuration on the current penetration are taken into account in the numerical simulation. The measurement method and obtained results are discussed.展开更多
The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced...The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff.展开更多
基金supported by the Youth Science Foundation of Sichuan Province(Nos.2022NSFSC1230 and 2022NSFSC1231)the Science and Technology Innovation Seedling Project of Sichuan Province(No.MZGC20230080)+1 种基金the General project of the National Natural Science Foundation of China(No.12075039)the Key project of the National Natural Science Foundation of China(No.U19A2086)。
文摘A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents.
文摘The method using pulsed eddy currents to determine the thickness of a conduction plate is extended to enable the simultaneous measurement of the plate thickness and material properties. For optimal performance, a probe must be designed depending on the thickness range that should be accessible. The need for a calibration of the material properties of a conducting plate to enable the measurement of its thickness has been removed. All that is needed is a probe with known dimensions and suitable hardware to create a current pulse and measure a transient magnetic induction.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 12174446 and 61671458)。
文摘Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.
基金the Ministry of Science and Higher Education of the Russian Federation under Grant No.FSUN-2023-0007.
文摘Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic noise level of measuring instruments.This leads to the need for multiple measurements with subsequent statistical processing.In this paper,the digital algorithms are proposed for the automatic measurement of the JJ parameters by IVC.These algorithms make it possible to implement multiple measurements and check these JJ parameters in an automatic mode with the required accuracy.The complete sufficient statistics are used to minimize the root-mean-square error of parameter measurement.A sequence of current pulses with slow rising and falling edges is used to drive JJ,and synchronous current and voltage readings at JJ are used to realize measurement algorithms.The algorithm performance is estimated through computer simulations.The significant advantage of the proposed algorithms is the independence from current source noise and intrinsic noise of current and voltage meters,as well as the simple implementation in automatic digital measuring systems.The proposed algorithms can be used to control JJ parameters during mass production of superconducting integrated circuits,which will improve the production efficiency and product quality.
基金supported in part by the National Natural Science Foundation of China(Grant No.92060114)in part by the Sichuan Science and Technology Program(Nos.2022YFS0524 and 2022YFG0044).
文摘It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate testing signals.This speed measurement method is complicated,and inevitable abrasion and occasional slippage will reduce the measurement accuracy.In order to solve this problem,based on eddy current effect due to the relative movement,a speed measurement method is proposed,which is contactless and simple.In the high-speed MFL testing,eddy current induced in the specimen will cause an obvious modification to the applied field.This modified field,which is measured by Hall sensor,can be utilized to reflect the moving speed.Firstly,the measurement principle is illustrated based on Faraday’s law.Then,dynamic finite element simulations are conducted to investigate the modified magnetic field distribution.Finally,laboratory experiments are performed to validate the feasibility of the proposed method.The results show that Bmz(r1)and Bmx(r2)have a linear relation with moving speed,which could be used as an alternative measurement parameter.
文摘Although near infrared (NIR) spectroscopy has been evaluated for numerous applications, the number of actual on-line or even on-site industrial applications seems to be very limited. In the present paper, the attempts to produce online predictions of the chemical oxygen demand (COD) in wastewater from a pulp and paper mill using NIR spectroscopy are described. The task was perceived as very challenging, but with a root mean square error of prediction of 149 mg/l, roughly corresponding to 1/10 of the studied concentration interval, this attempt was deemed as successful. This result was obtained by using partial least squares model regression, interpolated reference values for calibration purposes, and by evenly distributing the calibration data in the concentration space. This work may also represent the first industrial application of online COD measurements in wastewater using NIR spectroscopy.
文摘In this paper,a method of multipoint pseudorandom combined excita-tion with the orthogonal reciprocal repeated sequences(ORRS)is presented on thebackground of the on-line identification of multivariate system.The capacity of therestraint to the identification error caused by the non-random D.C.drift of the mul-ti-input excitation with the ORRS in the multivariate system is also discussed.Thevalidity of the method described in this paper is proved by the modelling tests of themulti-plate rotor system.
文摘A new approach to the on-line temperature rise measurement of submersible pump's motors is presented. A new method of power supply and signed transmission for the measurement device in the pump well is also put forward here. The design and some experimental results are given.
基金Reactor Pressure Boundary Materials Project !under the Nuclear R & D Program by MOST in Korea.
文摘A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation.
基金This work was supported by the National Natural Science Foundation of China under contract Nos 40176007 and 49736200the Major State Ba-Sic Research Program of China under contract No.G 1999043802.
文摘Direct measurements of current velocity and water temperature were undertaken at the mooring Sta. M (125°29.38' N, 31°49.70' E) on the continental shelf area in the East China Sea in June 1999 by R/V Xiangyanghong 14. The relationship between various time series of oceanic fluctuations is calculated by spectral analysis. The major results are as follows: (1) an average (u,v) of (6.9,-3.0 cm/s) at the 30 m depth is obtained during the 9-day observation, and that at the 45 m depth is (3.7,-1.1 cm/s), i. e., the mean flows are southeastward at both the 30 and 45 m depths;the currents become stronger gradually during the observation period; this may be mainly attributed to the transition of the tidal currents from neap to spring; (2)semidiurnal fluctuation is the most dominant in the current fluctuations, and rotates mainly clockwise; in the next place, there is also diurnal fluctuation;the local inertial period is close to the period of diurnal fluctuation, and an inertial motion is clockwise; thus, local inertial motion combines with diurnal fluctuation, and makes the spectral peaks in clockwise components much higher than those in counterclockwise ones; except for the fluctuations of above main periods, there is also the peak at 3 d period for counterclockwise compo-nents in the upper and lower layers; (3) the calculation of cross spectra between two time series of current velocities at the 30 and 45 m depths shows that both the current fluctuations at the 30 and 45 m depths are much alike, i. e., they are synchro; this shows that the flow field here is rather vertically homogeneous; (4)power spectra of tempera-ture time series at both the 30 and 45 m depths show that the semidiurnal peak is the most predominant, and the second highest peak is the diurnal period; besides spectral peaks at above periods, there are also obvious spectral peaks at 6.8 h and 2 d; (5)plots of temperature time series at 16 , 30 , 35 , 45 and 50 m depths show that the temporal variations of temperature at these depths are synchro, which are like those in the velocity field; temperature records also show a gradual rise in temperature, which are also like those in the velocity field.
基金Supported by National Natural Science Foundation of China(Grant No.51277154)Xiamen Key Laboratory of Optoelectronic Transducer Technology+1 种基金Fujian Key Laboratory of Universities and Colleges for Transducer TechnologyInnovative Talents Program of Far East NDT New Technology&Application Forum
文摘In eddy current testing, the law of attenuation of eddy current(EC) is of great concern. In conductive half space under the excitation of uniform magnetic field, the EC density decreases exponentially in the depth direction. However, in conductor with finite thickness tested by coil, the distribution of EC in the depth direction is more complicated. This paper studies the characteristics of EC attenuation in metallic plate of finite thickness. Simulation results show that there is an EC reflection at the bottom of plate, which changes the law of EC attenuation. A new concept, namely the equivalent attenuation coefficient, is proposed to quantify the speed of EC attenuation. The characteristics of EC attenuation are utilized to explain the nonmonotonic relation between coil voltage and plate thickness. Procedure of selecting frequency is discussed. Thereafter, measurement of plate thickness is carried out and accurate result is obtained.
基金National Natural Science Foundation of China(No.51775377)National Key Research and Development Plan(No.2017YFF0204800)+2 种基金Natural Science Foundation of TianJin City(No.17JCQNJC01100)Young Elite Scientists Sponsorship Program by Cast of China(No.2016QNRC001)Open Project of Key Laboratory of Underwater Information and Control(No.6142218081811)
文摘With the development of power plants towards high power and intelligent operation direction,the vibrations or failures of blades,especially the last stage blades in steam turbines,happen more frequently due to the unstable operating conditions brought by flexible operation.A vibration measuring method for the shrouded blades of a steam turbine based on eddy current sensors with high frequency response is proposed,meeting the requirements of non-contact heath monitoring.The eddy current sensors produce the signals which are related to the area changing of every blade’s shroud resulting from the rotation of stator.Then an improved blade tip timing(BTT)technique is proposed to detect the vibrations of shrouded blades by measuring the arrival time of each area changing signal.A structure of eddy current sensors is developed in steam turbines and an amplitude modulation/demodulation circuit is designed to improve the response bandwidth up to 250 kHz.Vibration tests for the last stage blades of a steam turbine were carried out and the results validate the efficiency of the improved BTT technique and the high frequency response of the eddy current sensors presented.
文摘Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive model for errors calculation in an on-line measuring System of machining center have been built for the first time. Using this model, the errors can be compensated by soft.ware and the measuring accuracy can be enhanced without any more inveSt. This model can be used in all kinds of machining center.
文摘Luquire et al. ' s impedance change model of a rectangular cross section probe coil above a structure with an arbitrary number of parallel layers was used to study the principle of measuring thicknesses of multi-layered structures in terms of eddy current testing voltage measurements. An experimental system for multi-layered thickness measurement was developed and several fitting models to formulate the relationships between detected impedance/voltage measurements and thickness are put forward using least square method. The determination of multi-layered thicknesses was investigated after inversing the voltage outputs of the detecting system. The best fitting and inversion models are presented.
文摘Objective: To quantitatively identify and grade trigeminal sensory functions after 3 major surgical procedures of trigeminal neuralgia using a newly developed quantitative sensory testing technique, current perception threshold measurement (CPTM). Methods: In the current study, there were 48 trigeminal neuralgia patients without history of prior surgical treatment. These patients received one of the following 3 surgical procedures, microvascular decompression (MVD), peripheral nerve block with alcohol (PNB), or percutaneous radiofrequency thermocoagulation (PRFT). The quantitative sensory testing measurement, CPTM, and conventional qualitative sensory testing measurements were performed preoperatively and postoperatively to evaluate and grade the trigeminal sensory functions All 3 major cutaneous sensory fiber types, large myelinated fibers (A beta), small myelinated fibers (A delta) and unmyelinated fibers(C) were allowed to quantitatively evaluate and grade by CPTM. The results of the measurements were statistically analyzed using a one-way analysis of variance (single factor). Each subject was his/her own control for comparison of the preoperative to postoperative state on the asymptomatic and symptomatic sides. Subjects were tested 48 h preoperatively and 4 weeks postoperatively. Results: PNB with alcohol and PRFT caused significant sensory dysfunction postoperatively in every fiber type, indicating damage to all fibers. On the contrary, the sensory function in all 3 fiber types was unchanged after MVD management. Conclusion: Among the 3 major surgical procedures tested, only MVD preserves sensory function in trigeminal system. CPTM is of quantitative nature on the evaluation of sensory functions of nerve fibers
基金supported by the National Natural Science Foundation of China(No.41805105)。
文摘On-line chemical characterization of atmospheric particulate matter(PM)with soft ionization technique and ultrahigh-resolution Mass Spectrometry(UHRMS)provides molecular information of organic constituents in real time.Here we describe the development and application of an automatic measurement system that incorporates PM_(2.5)sampling,thermal desorption,atmospheric pressure photoionization,and UHRMS analysis.Molecular formulas of detected organic compounds were deducted from the accurate(±10 ppm)molecular weights obtained at a mass resolution of 100,000,allowing the identification of small organic compounds in PM_(2.5).Detection efficiencies of 28 standard compounds were determined and we found a high sensitivity and selectivity towards organic amines with limits of detection below 10 pg.As a proof of principle,PM_(2.5)samples collected off-line in winter in the urban area of Beijing were analyzed using the Ionization Module and HRMS of the system.The automatic system was then applied to conduct on-line measurements during the summer time at a time resolution of 2 hr.The detected organic compounds comprised mainly CHON and CHN compounds below 350 m/z.Pronounced seasonal variations in elemental composition were observed with shorter carbon backbones and higher O/C ratios in summer than that in winter.This result is consistent with stronger photochemical reactions and thus a higher oxidation state of organics in summer.Diurnal variation in signal intensity of each formula provides crucial information to reveal its source and formation pathway.In summary,the automatic measurement system serves as an important tool for the on-line characterization and identification of organic species in PM_(2.5).
基金Supported by National High-Tech Industry Development Project (1883)
文摘Magnetic sensor arrays are proposed to measure electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. Simulation techniques are necessary to study the factors influencing the accuracy of current measurement. This paper presents a simulation method to estimate the impact of sensing area and position of sensors on the accuracy of current measurement. Several error models are built up to support computer-aided design of magnetic sensor arrays.
基金supported by National Natural Science Foundation of China (No.50477027)
文摘A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Performance tests show that the Rogowski coil has both excellent dynamic and static characteristics. Calibrating results and the comparison between the standard current shunt and the developed Rogowski coil for the measurement of nanosecond discharge pulses demonstrate that the developed Rogowski coil can reproduce the actual waveform of the discharge current accurately.
基金The project supported by the National Natural Science Foundation of China (Nos. 19789502 and 19889506)
文摘The plasma current is modulated with an alternating current (ac) component in a frequency range of 90 Hz - 900 Hz in the plateau discharge phase in the CT-6B tokamak. A plasma electric conductivity profile in a form of (1 - r^2/a^2)^α with a parameter α which is fitted with the experimental data, can be determined. The effects of magnetic shear in a tokamak field configuration on the current penetration are taken into account in the numerical simulation. The measurement method and obtained results are discussed.
文摘The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff.