期刊文献+
共找到17,390篇文章
< 1 2 250 >
每页显示 20 50 100
Utilising continuous glucose monitoring for glycemic control in diabetic kidney disease
1
作者 Vamsidhar Veeranki Narayan Prasad 《World Journal of Diabetes》 SCIE 2024年第10期2006-2009,共4页
In this editorial,we comment on the article by Zhang et al.Chronic kidney disease(CKD)presents a significant challenge in managing glycemic control,especially in diabetic patients with diabetic kidney disease undergoi... In this editorial,we comment on the article by Zhang et al.Chronic kidney disease(CKD)presents a significant challenge in managing glycemic control,especially in diabetic patients with diabetic kidney disease undergoing dialysis or kidney transplantation.Conventional markers like glycated haemoglobin(HbA1c)may not accurately reflect glycemic fluctuations in these populations due to factors such as anaemia and kidney dysfunction.This comprehensive review discusses the limitations of HbA1c and explores alternative methods,such as continuous glucose monitoring(CGM)in CKD patients.CGM emerges as a promising technology offering real-time or retrospective glucose concentration measure-ments and overcoming the limitations of HbA1c.Key studies demonstrate the utility of CGM in different CKD settings,including hemodialysis and peritoneal dialysis patients,as well as kidney transplant recipients.Despite challenges like sensor accuracy fluctuation,CGM proves valuable in monitoring glycemic trends and mitigating the risk of hypo-and hyperglycemia,to which CKD patients are prone.The review also addresses the limitations of CGM in CKD patients,emphasizing the need for further research to optimize its utilization in clinical practice.Altogether,this review advocates for integrating CGM into managing glycemia in CKD patients,highlighting its superiority over traditional markers and urging clinicians to consider CGM a valuable tool in their armamentarium. 展开更多
关键词 Chronic kidney disease Diabetic kidney disease Glycemic control Continuous glucose monitoring Glycated hemoglobin Glycemic variability
下载PDF
Development and application of ocean station auto monitoring data on-line quality control system
2
作者 WANG Qisong FANG Shulin +1 位作者 YIN Danni ZHAO Yueru 《Marine Science Bulletin》 2021年第1期71-79,共9页
The quality control of ocean observation data is conducted by monthly review,yet no on-line quality control system is deployed.An on-line quality control system is provided by this article.The threshold of extreme and... The quality control of ocean observation data is conducted by monthly review,yet no on-line quality control system is deployed.An on-line quality control system is provided by this article.The threshold of extreme and rate of change is created by analyzing the character of observation items.The alert will be triggered to remind the operator if the system detects data out of threshold.therefore the on-line data quality control is accomplished. 展开更多
关键词 ocean station DATA on-line quality control
下载PDF
Development and Application of On-Line Corrosion Monitoring Device for Condenser Tube 被引量:1
3
作者 曹杰玉 宋敬霞 +2 位作者 汪德良 龙国军 孙本达 《Electricity》 2004年第2期31-35,共5页
This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te... This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate. 展开更多
关键词 condenser tube CORROSION on-line monitoring INSTRUMENTATION
下载PDF
On-Line Monitoring of Cutting Tool Fracture & Wear
4
作者 王信义 肖定国 宋新民 《Journal of Beijing Institute of Technology》 EI CAS 1992年第2期139-150,共12页
A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The te... A technique of detecting cutting tool fracture and ultimate wear by si- multaneously monitoring both the spindle motor current and cutting process related acoustic emission(AE)in the cutting process is reported.The technique can detect breakage of drills having diameter over 0.8mm,turning cutter crack of area over 0.2mm,and the ultimate wear.The principle,system construction,experimental method and result of the technique are discussed.The ratio of success in detection approaches 96% or higher. 展开更多
关键词 on-line monitoring acoustic emission/tool fracture motor current
下载PDF
Continuous glucose monitoring metrics in pregnancy with type 1 diabetes mellitus
5
作者 Mohammad Sadiq Jeeyavudeen Mairi Crosby Joseph M Pappachan 《World Journal of Methodology》 2024年第1期6-17,共12页
Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level mon... Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level monitoring and periodic HbA1c tests,the advent of continuous glucose monitoring(CGM)systems has revolutionized the approach.These devices offer a safe and reliable means of tracking glucose levels in real-time,benefiting both women with diabetes during pregnancy and the healthcare providers.Moreover,CGM systems have shown a low rate of side effects and high feasibility when used in pregnancies complicated by diabetes,especially when paired with continuous subcutaneous insulin infusion pump as hybrid closed loop device.Such a combined approach has been demonstrated to improve overall blood sugar control,lessen the occurrence of preeclampsia and neonatal hypoglycaemia,and minimize the duration of neonatal intensive care unit stays.This paper aims to offer a comprehensive evaluation of CGM metrics specifically tailored for pregnancies impacted by type 1 diabetes mellitus. 展开更多
关键词 Type 1 diabetes mellitus Continuous glucose monitoring PREGNANCY Glycaemic control Continuous glucose monitoring system
下载PDF
A HybridManufacturing ProcessMonitoringMethod Using Stacked Gated Recurrent Unit and Random Forest
6
作者 Chao-Lung Yang Atinkut Atinafu Yilma +2 位作者 Bereket Haile Woldegiorgis Hendrik Tampubolon Hendri Sutrisno 《Intelligent Automation & Soft Computing》 2024年第2期233-254,共22页
This study proposed a new real-time manufacturing process monitoring method to monitor and detect process shifts in manufacturing operations.Since real-time production process monitoring is critical in today’s smart ... This study proposed a new real-time manufacturing process monitoring method to monitor and detect process shifts in manufacturing operations.Since real-time production process monitoring is critical in today’s smart manufacturing.The more robust the monitoring model,the more reliable a process is to be under control.In the past,many researchers have developed real-time monitoring methods to detect process shifts early.However,thesemethods have limitations in detecting process shifts as quickly as possible and handling various data volumes and varieties.In this paper,a robust monitoring model combining Gated Recurrent Unit(GRU)and Random Forest(RF)with Real-Time Contrast(RTC)called GRU-RF-RTC was proposed to detect process shifts rapidly.The effectiveness of the proposed GRU-RF-RTC model is first evaluated using multivariate normal and nonnormal distribution datasets.Then,to prove the applicability of the proposed model in a realmanufacturing setting,the model was evaluated using real-world normal and non-normal problems.The results demonstrate that the proposed GRU-RF-RTC outperforms other methods in detecting process shifts quickly with the lowest average out-of-control run length(ARL1)in all synthesis and real-world problems under normal and non-normal cases.The experiment results on real-world problems highlight the significance of the proposed GRU-RF-RTC model in modern manufacturing process monitoring applications.The result reveals that the proposed method improves the shift detection capability by 42.14%in normal and 43.64%in gamma distribution problems. 展开更多
关键词 Smart manufacturing process monitoring quality control gated recurrent unit neural network random forest
下载PDF
Determination of Monitoring Control Value for Concrete Gravity Dam Spatial Deformation Based on POT Model
7
作者 Zhiwen Xie Tiantang Yu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第6期2119-2135,共17页
Deformation can directly reflect the working behavior of the dam,so determining the deformation monitoring control value can effectively monitor the safety of dam operation.The traditional dam deformation monitoring c... Deformation can directly reflect the working behavior of the dam,so determining the deformation monitoring control value can effectively monitor the safety of dam operation.The traditional dam deformation monitoring control value only considers the single measuring point.In order to overcome the limitation,this paper presents a new method to determine the monitoring control value for concrete gravity dam based on the deformations of multi-measuring points.A dam’s comprehensive deformation displacement is determined by the measured values at different measuring points on the positive inverted vertical line and the corresponding weight of eachmeasuring point.The projection pursuit method(PPM)combined with the grey wolf optimization(GWO)algorithm is used to determine the weight of each measuring point according to the spatial correlation distribution characteristics of dam deformation.The peaks over threshold(POT)model based on the extreme value theory is adopted to determine the monitoring control value with the obtained dam comprehensive deformation displacement.In addition,the POTmodel is improved with the automatic threshold determinationmethod based on the 3σcriterion in probability theory and the GWO algorithm,which can avoid subjectivity and randomness in determining the threshold.The results of the engineering application show the feasibility and applicability of the proposed method. 展开更多
关键词 Concrete gravity dam DEFORMATION monitoring control value PPM GWO POT
下载PDF
On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor 被引量:4
8
作者 崔有为 王淑莹 李晶 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2009年第3期484-492,共9页
For efficient energy consumption and control of effluent quality, the cycle duration for a sequencing batch reactor (SBR) needs to be adjusted by real-time control according to the characteristics and loading of waste... For efficient energy consumption and control of effluent quality, the cycle duration for a sequencing batch reactor (SBR) needs to be adjusted by real-time control according to the characteristics and loading of waste-water. In this study, an on-line information system for phosphorus removal processes was established. Based on the analysis for four systems with different ecological community structures and two operation modes, anaerobic-aerobic process and anaerobic-anaerobic process, the characteristic patterns of oxidation-reduction potential (ORP) and pH were related to phosphorous dynamics in the anaerobic, anoxic and aerobic phases, for determination of the end of phosphorous removal. In the operation mode of anaerobic-aerobic process, the pH profile in the anaerobic phase was used to estimate the relative amount of phosphorous accumulating organisms (PAOs) and glycogen accumulat-ing organisms (GAOs), which is beneficial to early detection of ecology community shifts. The on-line sensor val-ues of pH and ORP may be used as the parameters to adjust the duration for phosphorous removal and community shifts to cope with influent variations and maintain appropriate operation conditions. 展开更多
关键词 on-line monitoring phosphorus removal sequencing batch reactor PH oxidation-reduction potential
下载PDF
Tool Condition Monitoring Based on Nonlinear Output Frequency Response Functions and Multivariate Control Chart
9
作者 Yufei Gui Ziqiang Lang +1 位作者 Zepeng Liu Hatim Laalej 《Journal of Dynamics, Monitoring and Diagnostics》 2023年第4期243-251,共9页
Tool condition monitoring(TCM)is a key technology for intelligent manufacturing.The objective is to monitor the tool operation status and detect tool breakage so that the tool can be changed in time to avoid significa... Tool condition monitoring(TCM)is a key technology for intelligent manufacturing.The objective is to monitor the tool operation status and detect tool breakage so that the tool can be changed in time to avoid significant damage to workpieces and reduce manufacturing costs.Recently,an innovative TCM approach based on sensor data modelling and model frequency analysis has been proposed.Different from traditional signal feature-based monitoring,the data from sensors are utilized to build a dynamic process model.Then,the nonlinear output frequency response functions,a concept which extends the linear system frequency response function to the nonlinear case,over the frequency range of the tooth passing frequency of the machining process are extracted to reveal tool health conditions.In order to extend the novel sensor data modelling and model frequency analysis to unsupervised condition monitoring of cutting tools,in the present study,a multivariate control chart is proposed for TCM based on the frequency domain properties of machining processes derived from the innovative sensor data modelling and model frequency analysis.The feature dimension is reduced by principal component analysis first.Then the moving average strategy is exploited to generate monitoring variables and overcome the effects of noises.The milling experiments of titanium alloys are conducted to verify the effectiveness of the proposed approach in detecting excessive flank wear of solid carbide end mills.The results demonstrate the advantages of the new approach over conventional TCM techniques and its potential in industrial applications. 展开更多
关键词 intelligent manufacturing multivariate control chart Nonlinear Autoregressive with eXogenous Input modelling Nonlinear Output Frequency Response Functions tool condition monitoring
下载PDF
Research on Distribution of Electromagnetic Environment around Substations and Optimization Layout of On-line Monitoring 被引量:1
10
作者 Li Peiming Xiao Jun Wang Wenjin 《Meteorological and Environmental Research》 CAS 2019年第6期60-63,共4页
The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating... The characteristics and distribution law of electromagnetic environment around substations with different levels of voltage were studied,and the main influencing factors were discussed. Meanwhile,a scheme for locating monitoring points suitable for an on-line monitoring system of electromagnetic environment was proposed. 展开更多
关键词 on-line monitoring ELECTROMAGNETIC environment SUBSTATION Optimization layout
下载PDF
On-line monitoring of dissolved gas-in-oil with FTIR spectra 被引量:1
11
作者 XianyongLiu YunluoLiu LiYue 《Journal of University of Science and Technology Beijing》 CSCD 2003年第4期65-68,共4页
To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved ... To overcome the disadvantages of conventional DGA (dissolved gas-in-oil)analysis using gas chromatography and other electrochemical sensors, initial researches werecompleted to realize on-line monitoring of dissolved gas-in-oil of power transformers using FTIR(Fourier Transform InfraRed) spectroscopy. Gas cell method is used to determine the characteristicabsorption peaks of each diagnostic gas; simple and novel devices and procedures were designed inorder to get measurable samples and spectra of mixed diagnostic gases with known concentration aretaken using long optical path gas cell. The range of wavelength is estimated to be 3.0-13.9 mum fromexperimental spectra data. Hence the corresponding sampling frequency range should be in 536-4288Hz and usable optical materials are suggested. It is concluded that a resolution of 10 cm^(-1) maywell satisfy the monitoring of all diagnostic gases and water content except hydrogen, and thelowest detection limit may be as low as 2Xl0^(-8) to acetylene with a 2.4-meter-long optical length. 展开更多
关键词 FTIR power transformer dissolved gas-in-oil on-line monitoring INFRAREDSPECTRA
下载PDF
On-line Condition Monitoring and Diagnostic Network System for Rotating Machine Set 被引量:1
12
作者 Li Fucai, He Zhengjia, Zi Yanyang School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China 《International Journal of Plant Engineering and Management》 2000年第4期136-141,共6页
Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition.... Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition. Through analyzing running data, technicians can detect whether there exist faults and where they occur. To share and transmit the dynamic information of the turbo-generator sets, a distributed network system is introduced. NetWare network operating system is used in the LAN (Local Area Network) system. The LAN is extended to realize the sharing of data and remote transmission of information. Furthermore, functions of monitoring and diagnostic clients are listed. 展开更多
关键词 rotating machine set on-line monitoring and diagnostic network system
下载PDF
On-line monitoring of insulation quality of high voltage electric power equipment
13
作者 SUN He-yi, ZHAO Xue-zeng, NIE Peng, BAI Jing-feng, YANG Yan-zhu (Harbin Institute of Technology, Harbin 150001, China) 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2000年第S1期77-80,共4页
Discusses on-line monitoring of electric parameters, such as dielectric loss, divulging current, equivalent capacitance and running voltage, and presents an on-line monitoring system of insulation quality, based on mo... Discusses on-line monitoring of electric parameters, such as dielectric loss, divulging current, equivalent capacitance and running voltage, and presents an on-line monitoring system of insulation quality, based on monitoring divulging current and dielectric loss of high voltage equipment, and its advantages, such as helping people to discover the hidden problems in a timely manner, to reduce power cut and overhaul and to improve security of power supply. 展开更多
关键词 INSULATION CAPABILITY HIGH-VOLTAGE EQUIPMENT on-line monitoring data PROCESSING
下载PDF
Research Progress of On-line Monitoring Technology for Electromagnetic Environment of Power Transmission and Transformation Projects
14
作者 Li Peiming Zhou Jian +2 位作者 Xiao Jun Wang Wenjin Ge Xiaoyang 《Meteorological and Environmental Research》 CAS 2019年第6期67-71,共5页
Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home a... Based on the collection of relevant literature and cases,the research and application status of on-line monitoring technology for electromagnetic environment of power transmission and transformation projects at home and abroad were introduced.Moreover,the problems existing in the on-line monitoring of electromagnetic environment were expounded,and the development prospect was forecasted. 展开更多
关键词 on-line monitoring TECHNOLOGY ELECTROMAGNETIC environment Power TRANSMISSION and TRANSFORMATION PROJECT
下载PDF
An On-line Monitoring System for Partial Dischargefrom High Voltage Transformer
15
作者 王哲 陈学允 蔡惟铮 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第2期52-56,共5页
An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is propose... An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges. 展开更多
关键词 Partial DISCHARGE on-line monitoring technique DISCRETE FOURIER TRANSFORM (DFT) DISCRETE WAVELET transform(DWT)
下载PDF
Analysis and Application of the Synthetic Relative Measuring Method in On-Line Monitoring for Capacitive Equipment in Power Systems
16
作者 Qing Guo Li-Jun Qin Hua-Wei Jin 《Journal of Electronic Science and Technology》 CAS 2011年第3期270-277,共8页
On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings... On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice. 展开更多
关键词 Index Terms-Capacitive equipment dielectric loss angle on-line monitoring synthetic relative measuring method failure judgment matrix.
下载PDF
Insulation State On-line Monitoring and Running Management of Large Generator
17
作者 Qiudong Sun Zhengxin Zhou Weiqin Guo 《Energy and Power Engineering》 2010年第3期203-207,共5页
This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF... This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective. 展开更多
关键词 Large GENERATOR PARTIAL DISCHARGE RADIO Frequency Technique on-line monitoring Running MANAGEMENT
下载PDF
Wireless Distributed Monitoring Terminal Used for On-Line Application
18
作者 Fenggui Wang Lin Zhang +1 位作者 Zhongmin Wang Yanbo Zhang 《Communications and Network》 2013年第3期549-553,共5页
A wireless distributed monitoring terminal was designed with embedded Linux used on the basis of ARM board, and an application program was developed for data collection, processing and transmission. Data were collecte... A wireless distributed monitoring terminal was designed with embedded Linux used on the basis of ARM board, and an application program was developed for data collection, processing and transmission. Data were collected from the surrounding environment and transmitted to a server via WLAN in the form of Extensible Markup Language (XML) stream, so the terminal had good flexibility to be compatible with different sensors, network devices and information systems from multiple manufacturers. 展开更多
关键词 on-line monitoring DISTRIBUTED monitoring Extensible MARKUP Language (XML) STREAM WIRELESS TERMINAL
下载PDF
On-line Batch Process Monitoring and Diagnosing Based on Fisher Discriminant Analysis
19
作者 赵旭 邵惠鹤 《Journal of Shanghai Jiaotong university(Science)》 EI 2006年第3期307-312,316,共7页
A new on-line batch process monitoring and diagnosing approach based on Fisher discriminant analysis (FDA) was proposed. This method does not need to predict the future observations of variables, so it is more sensi... A new on-line batch process monitoring and diagnosing approach based on Fisher discriminant analysis (FDA) was proposed. This method does not need to predict the future observations of variables, so it is more sensitive to fault detection and stronger implement for monitoring. In order to improve the monitoring performance, the variables trajectories of batch process are separated into several blocks. The key to the proposed approach for on-line monitoring is to calculate the distance of block data that project to low-dimension Fisher space between new batch and reference batch. Comparing the distance with the predefine threshold, it can be considered whether the batch process is normal or abnormal. Fault diagnosis is performed based on the weights in fault direction calculated by FDA. The proposed method was applied to the simulation model of fed-batch penicillin fermentation and the resuits were compared with those obtained using MPCA. The simulation results clearly show that the on-line monitoring method based on FDA is more efficient than the MPCA. 展开更多
关键词 batch process on-line process monitoring fault diagnosis Fisher discriminant analysis (FDA) multiway principal component analysis (MPCA)
下载PDF
Mechanics Analysis of Overhead Transmission Lines Based On-line Monitoring
20
作者 Lili Dai Yongli Zhu Zehui Liang 《Open Journal of Applied Sciences》 2013年第2期1-4,共4页
At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the p... At present, the on-line monitoring is widely applied to the power line monitoring. In this paper, a new mechanical calculation model is established according to the on-line monitoring. And this model is based on the parameters that tension sensors and angle sensors on suspended points detect, and combines with the parameters of the wire itself, and also considers the deflection angel of wires due to wind. In this model, mechanics parameters of wires are turned into the new coordinate plane after deflection angel of wires due to wind, or windage yaw plane. A statics tension balance equation is built in the vertical direction of the new windage yaw plane. According to the theoretical analysis and algorithm, we verify the accuracy of this newly developed mechanical calculation model. 展开更多
关键词 OVERHEAD Transmission Line on-line monitoring Mechanical ANALYSIS Tension ANGLE ICING Windage Yaw
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部