A novel vapor-liquid distributor was developed on the basis of sufficient study on the existing distributors applied in hydroprocessing reactors. The cold model test data showed that the fluid distribution performance...A novel vapor-liquid distributor was developed on the basis of sufficient study on the existing distributors applied in hydroprocessing reactors. The cold model test data showed that the fluid distribution performance of the novel vapor-liquid distributor was evidently better than the traditional one. Com- mercial tests of the new distributor were carded out in the 300 kt/a gas oil hydrotreating reactor at SINOPEC Changling Branch Company, showing that the new vapor-liquid distributor could improve the fluid distribution, promote the hydrotreating efficiency and lead to better performance than the traditional one.展开更多
Short residence time of the sorbent in the gas stream and formation of a dense layer of reaction product surrounding its surface influence the sulfur removal efficiency. A practical means of improving the process perf...Short residence time of the sorbent in the gas stream and formation of a dense layer of reaction product surrounding its surface influence the sulfur removal efficiency. A practical means of improving the process performance is to employ fluidized bed reaction in replacement of entrained bed reaction on normally used in cool side desulfurizaiton. This paper describes cold modeling study of a circulating fluidized bed reactor. Several aspects of the problem are discussed: fluidization behavior of CaO, attrition of the sorbent and solids entrainment from the fluidized bed. Mechanisms and key controlling parameters are identified, and an integral model based on rate of attrition and mass balance is developed for predicting steady state mass flows and particle size distributions of the system. A process flow scheme is finally presented for conducting desulfurization tests in the second stage of the study.展开更多
This paper discusses the results obtained during an investigation of WWER-1000 Nuclear Power Plant (NPP) behavior at shutdown reactor during maintenance. For the purpose of the analysis is selected a plant operating s...This paper discusses the results obtained during an investigation of WWER-1000 Nuclear Power Plant (NPP) behavior at shutdown reactor during maintenance. For the purpose of the analysis is selected a plant operating state with unsealed primary circuit by removing the MCP head. The reference nuclear power plant is Unit 6 at Kozloduy NPP (KNPP) site. RELAP5/ MOD3.2 computer code has been used to simulate the transient for WWER-1000/V320 NPP model. A model of WWER-1000 based on Unit 6 of KNPP has been developed for the RELAP5/MOD3.2 code at the Institute for Nuclear Research and Nuclear Energy-Bulgarian Academy of Sciences (INRNE-BAS), Sofia. The plant modifications performed in frame of modernization program have been taken into account for the investigated conditions for the unsealed primary circuit. The most specific in this analysis compared to the analyses of NPP accidents at full power is the unavailability of some important safety systems. For the purpose of the present investigation two scenarios have been studied, involving a different number of safety systems with and without operator actions. The selected initiating event and scenarios are used in support of analytical validation of Emergency Operating Procedures (EOP) at low power and they are based on the suggestions of leading KNPP experts and are important in support of analytical validation of EOP at low power.展开更多
文摘A novel vapor-liquid distributor was developed on the basis of sufficient study on the existing distributors applied in hydroprocessing reactors. The cold model test data showed that the fluid distribution performance of the novel vapor-liquid distributor was evidently better than the traditional one. Com- mercial tests of the new distributor were carded out in the 300 kt/a gas oil hydrotreating reactor at SINOPEC Changling Branch Company, showing that the new vapor-liquid distributor could improve the fluid distribution, promote the hydrotreating efficiency and lead to better performance than the traditional one.
文摘Short residence time of the sorbent in the gas stream and formation of a dense layer of reaction product surrounding its surface influence the sulfur removal efficiency. A practical means of improving the process performance is to employ fluidized bed reaction in replacement of entrained bed reaction on normally used in cool side desulfurizaiton. This paper describes cold modeling study of a circulating fluidized bed reactor. Several aspects of the problem are discussed: fluidization behavior of CaO, attrition of the sorbent and solids entrainment from the fluidized bed. Mechanisms and key controlling parameters are identified, and an integral model based on rate of attrition and mass balance is developed for predicting steady state mass flows and particle size distributions of the system. A process flow scheme is finally presented for conducting desulfurization tests in the second stage of the study.
文摘This paper discusses the results obtained during an investigation of WWER-1000 Nuclear Power Plant (NPP) behavior at shutdown reactor during maintenance. For the purpose of the analysis is selected a plant operating state with unsealed primary circuit by removing the MCP head. The reference nuclear power plant is Unit 6 at Kozloduy NPP (KNPP) site. RELAP5/ MOD3.2 computer code has been used to simulate the transient for WWER-1000/V320 NPP model. A model of WWER-1000 based on Unit 6 of KNPP has been developed for the RELAP5/MOD3.2 code at the Institute for Nuclear Research and Nuclear Energy-Bulgarian Academy of Sciences (INRNE-BAS), Sofia. The plant modifications performed in frame of modernization program have been taken into account for the investigated conditions for the unsealed primary circuit. The most specific in this analysis compared to the analyses of NPP accidents at full power is the unavailability of some important safety systems. For the purpose of the present investigation two scenarios have been studied, involving a different number of safety systems with and without operator actions. The selected initiating event and scenarios are used in support of analytical validation of Emergency Operating Procedures (EOP) at low power and they are based on the suggestions of leading KNPP experts and are important in support of analytical validation of EOP at low power.