This paper focused on the impact of window shades’physical characteristics and opening modes on annual air conditioning energy consumption of residential buildings in China.Three building models with different window...This paper focused on the impact of window shades’physical characteristics and opening modes on annual air conditioning energy consumption of residential buildings in China.Three building models with different window layouts were proposed initially,and then validated by the dimensionless indicator annual energy performance(AEP)to determine the final building model adopted in this study.Harbin,Beijing,Guangzhou,Changsha and Kunming were selected to represent five different climate zones in China.The shading model has taken six physical characteristics of window shades,viz.outer emissivity,inner emissivity,solar transmittance,solar reflectance,thermal infrared transmittance,conductivity and two opening modes,viz.up&down mode as well as left&right mode,into consideration.Besides,the window shades operation schedule was summarized through 949 valid questionnaires.The annual air conditioning energy consumption was calculated via EnergyPlus software,and then the impact of the above different opening modes and parameters on energy use were investigated.The analysis results indicated that the top&bottom opening mode is better than the left&right mode when used in Harbin,and the effect of two different modes in air conditioning energy consumption in Kunming is similar.But in the other three cities,the left and right mode is preferred.Besides,the analysis results of the impact of different physical characteristics on air conditioning energy use in different climate zones could help improve the energy performance of window shades.展开更多
A full planar tunable band pass resonator is introduced, which is constructed by using novel symmetric step impedance resonator (SIR) and hyperabrupt varactors for wide bandwidth tuning and size reduction. The equiv...A full planar tunable band pass resonator is introduced, which is constructed by using novel symmetric step impedance resonator (SIR) and hyperabrupt varactors for wide bandwidth tuning and size reduction. The equivalent circuit model of the proposed resonator is set up. Theoretical analysis based on transmission line as well as odd and even-mode method is completed. The attractiveness of the approach presented lies in its simplicity. Based on the detailed analysis, a 6 GHz to 10 GHz varactor tuned resonator is designed, fabricated, and measured. It shows wideband tuning ability of 37%. The experimental results of the resonator have a good agreement with the analysis results.展开更多
Large space circular coal storage dome(LSCCSD)offers an environmental and dependable alternative to open stockpiles,and it has been consequently widely applied in China.However,due to the lack of scientific guidelines...Large space circular coal storage dome(LSCCSD)offers an environmental and dependable alternative to open stockpiles,and it has been consequently widely applied in China.However,due to the lack of scientific guidelines,its natural ventilation performance is lower than expected.Natural ventilation potential strongly depends on the roof geometry and opening mode,which have not yet been investigated for LSCCSD.This paper presents a detailed evaluation of the impact of dome geometry(rise span ratio),opening height,and opening modes on the ventilation performance of LSCCSD.The evaluation is based on computational fluid dynamics(CFD)methods and is validated by available wind tunnel testing.We employed three evaluation indicators,which are wind pressure coefficient,effective ventilation rate,and wind speed ratio.The results demonstrate that the rise span ratio has a significant effect on the wind pressure difference and the effective ventilation rate increases by approximately 9%–42%with a single-annular opening.When double-annular openings are set in a strong positive pressure zone,the effective ventilation rate increases by 100%and the average wind speed ratio increases by 50%.When it is compared with single one with similar opening height,the effective ventilation rate increases by 25%.The optimum natural ventilation performance for LSCCSD is achieved at a rise span ratio of 0.37.In addition,the lateral middle opening is kept higher than the ridge top of the coal pile.The proposed evaluation approach and design parameters provided instructive information in the building design and ventilation control for LSCCSDs.展开更多
基金the financial supports provided by the National Natural Science Foundation of China(Project no.51978252)China National Key R&D Program‘Solutions to heating and cooling of buildings in the Yangtze River region’(Grant no.2016YFC0700305).
文摘This paper focused on the impact of window shades’physical characteristics and opening modes on annual air conditioning energy consumption of residential buildings in China.Three building models with different window layouts were proposed initially,and then validated by the dimensionless indicator annual energy performance(AEP)to determine the final building model adopted in this study.Harbin,Beijing,Guangzhou,Changsha and Kunming were selected to represent five different climate zones in China.The shading model has taken six physical characteristics of window shades,viz.outer emissivity,inner emissivity,solar transmittance,solar reflectance,thermal infrared transmittance,conductivity and two opening modes,viz.up&down mode as well as left&right mode,into consideration.Besides,the window shades operation schedule was summarized through 949 valid questionnaires.The annual air conditioning energy consumption was calculated via EnergyPlus software,and then the impact of the above different opening modes and parameters on energy use were investigated.The analysis results indicated that the top&bottom opening mode is better than the left&right mode when used in Harbin,and the effect of two different modes in air conditioning energy consumption in Kunming is similar.But in the other three cities,the left and right mode is preferred.Besides,the analysis results of the impact of different physical characteristics on air conditioning energy use in different climate zones could help improve the energy performance of window shades.
文摘A full planar tunable band pass resonator is introduced, which is constructed by using novel symmetric step impedance resonator (SIR) and hyperabrupt varactors for wide bandwidth tuning and size reduction. The equivalent circuit model of the proposed resonator is set up. Theoretical analysis based on transmission line as well as odd and even-mode method is completed. The attractiveness of the approach presented lies in its simplicity. Based on the detailed analysis, a 6 GHz to 10 GHz varactor tuned resonator is designed, fabricated, and measured. It shows wideband tuning ability of 37%. The experimental results of the resonator have a good agreement with the analysis results.
文摘Large space circular coal storage dome(LSCCSD)offers an environmental and dependable alternative to open stockpiles,and it has been consequently widely applied in China.However,due to the lack of scientific guidelines,its natural ventilation performance is lower than expected.Natural ventilation potential strongly depends on the roof geometry and opening mode,which have not yet been investigated for LSCCSD.This paper presents a detailed evaluation of the impact of dome geometry(rise span ratio),opening height,and opening modes on the ventilation performance of LSCCSD.The evaluation is based on computational fluid dynamics(CFD)methods and is validated by available wind tunnel testing.We employed three evaluation indicators,which are wind pressure coefficient,effective ventilation rate,and wind speed ratio.The results demonstrate that the rise span ratio has a significant effect on the wind pressure difference and the effective ventilation rate increases by approximately 9%–42%with a single-annular opening.When double-annular openings are set in a strong positive pressure zone,the effective ventilation rate increases by 100%and the average wind speed ratio increases by 50%.When it is compared with single one with similar opening height,the effective ventilation rate increases by 25%.The optimum natural ventilation performance for LSCCSD is achieved at a rise span ratio of 0.37.In addition,the lateral middle opening is kept higher than the ridge top of the coal pile.The proposed evaluation approach and design parameters provided instructive information in the building design and ventilation control for LSCCSDs.