To improve the detection accuracy and robustness of crowd anomaly detection,especially crowd emergency evacuation detection,the abnormal crowd behavior detection method is proposed.This method is based on the improved...To improve the detection accuracy and robustness of crowd anomaly detection,especially crowd emergency evacuation detection,the abnormal crowd behavior detection method is proposed.This method is based on the improved statistical global optical flow entropy which can better describe the degree of chaos of crowd.First,the optical flow field is extracted from the video sequences and a 2D optical flow histogram is gained.Then,the improved optical flow entropy,combining information theory with statistical physics is calculated from 2D optical flow histograms.Finally,the anomaly can be detected according to the abnormality judgment formula.The experimental results show that the detection accuracy achieved over 95%in three public video datasets,which indicates that the proposed algorithm outperforms other state-of-the-art algorithms.展开更多
Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal ner...Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters.A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer(RNFL) thickness and the optic disc tomography by spectraldomain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma(POAG).Methods:.This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control(n=51, 98 eyes), suspected glaucoma(n=81,.146 eyes), and POAG groups(n=55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness,.disc area(DA), cup area(CA), rim area(RA), disc volume(DV),cup volume(CV), rim volume(RV), cup / disc area ratio(CA / DA), rim / disc area ratio(RA / DA), cup / disc volume ratio(CV / DV) and rim / disc volume ratio(RV / DV).Results: Superior, nasal, and mean RNFL parameters, DA,CA,RA, DV, CV, CA / DA, RA / DA, CV / DV and RV / DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group,.the maximum area under the ROC curve(AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA / DA(0.998), followed by CA / DA(0.997). The AROC of CA, RA, CV, and DV were all > 0.900.Conclusion:.OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG.展开更多
Detection of polystyrene beads with a diameter of 100 nm was conducted using an optical disk drive tester equipped with a laser of 405 nm wavelength and an objective lens with a numerical aperture of 0.65. The polysty...Detection of polystyrene beads with a diameter of 100 nm was conducted using an optical disk drive tester equipped with a laser of 405 nm wavelength and an objective lens with a numerical aperture of 0.65. The polystyrene beads were used to mimic the influenza virus. A grooved disk with a (ZnS)85(SiO2)15/SiO2 layered surface structure was used for the detection. The detection of influenza viruses (A/Udorn/307/1972) with Au nanoparticles was also demonstrated using the optical disk drive tester. In this case, a grooved disk with an indium tin oxide (ITO) film was used. The ITO film functioned both to tune the reflectance of the disk and as an electrically conductive layer for scanning electron microscopy. In both cases, the target substances were successfully recognized in a single scan with a high scanning speed of 4.9 m/s. The results indicate that this optical disk system can be used to detect 100 nm scale substances like influenza viruses, which are smaller than the diffraction limit of the system.展开更多
This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal dis...This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal disk. The three ways including MO media, recordingmethod and readout method for increasing the disk ca- pacity havebeen discussed. Moreover, the importance with the exchange-coupledeffect between the magnetic layers and recording domain morphology isemphasized.展开更多
Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 ...Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 eyes) of normal subjects, 17 cases (34 eyes) of patients with big-cupped disk and 19 cases (37 eyes) of patients with POAG underwent Heidelberg Retina Tomograph (HRT) examination to get topography images and stereometric parameters of optic nerve head.Results: The stereometric parameters of optic nerve head of the normal, patients with big-cupped disk and POAG were 1) disk area (mm2): 1. 995± 0. 501, 2. 407±0. 661 and 2. 248±0.498; 2) cup area (mm2): 0.573±0.264, 1. 095±0. 673 and 1. 340±0. 516; 3) cup/disk ratio: 0. 25±0. 095, 0. 428±0. 176 and 0. 589±0.195; 4) rim area (mm2): 1.461±0.328, 1.312±0.418 and 0. 905± 0.409; 5)cup volume (mm3): 0. 108±0. 073, 0. 347±0. 346 and 0. 550 ±0. 394; 6) rim volume (mm3): 0. 421±0. 111, 0. 378±0. 225 and 0. 224±0. 189; 7) mean cup展开更多
针对变电一次设备状态监测中普遍存在的异常数据问题,提出了一种基于点排序识别聚类结构(Ordering Points to Identify the Clustering Structure,OPTICS)的状态监测异常数据过滤算法。通过对一次设备状态监测的历史数据进行异常数据特...针对变电一次设备状态监测中普遍存在的异常数据问题,提出了一种基于点排序识别聚类结构(Ordering Points to Identify the Clustering Structure,OPTICS)的状态监测异常数据过滤算法。通过对一次设备状态监测的历史数据进行异常数据特征分析,建立了基于密度聚类的异常数据过滤机制。并以某110 k V变电站一次设备变压器油色谱以及GIS SF6密度微水实验为例,对该算法的异常数据检测效果进行了验证。该算法与传统异常数据过滤算法的对比试验结果表明,该算法能够准确地识别异常数据的特征,有效过滤状态监测中的异常数据,显著降低噪声干扰,从而提高数据的可靠性。展开更多
Background:Alterations in macular thickness and vascular density before clinically visible diabetic retinopathy(DR)remain inconclusive.This study aimed to determine whether retinal manifestations in abnormal glucose m...Background:Alterations in macular thickness and vascular density before clinically visible diabetic retinopathy(DR)remain inconclusive.This study aimed to determine whether retinal manifestations in abnormal glucose metabolism(AGM)patients differ from those in the healthy individuals.Methods:PubMed,Embase,and Web of Science were searched between 2000 and 2021.The eligibility criteria were AGM patients without DR.Primary and secondary outcomes measured by optical coherence tomography(OCT)and OCT angiography(OCTA)were analyzed and expressed as standardized mean differences(SMDs)with 95%confidence intervals(CIs).A random-effects model was used in the data synthesis.The potential publication bias for the variables was evaluated using Egger’s test.Results:A total of 86 observational studies involving 13,773 participants and 15,416 eyes were included.OCT revealed that compared to healthy controls,the total macular thickness of AGM patients was thinner,including the thickness of fovea(-0.24,95%CI[-0.39,-0.08];P=0.002,I^(2)=87.7%),all regions of parafovea(-0.32,95%CI[-0.54,-0.11];P=0.003;I^(2)=71.7%)and the four quadrants of perifovea;the thickness of peripapillary retinal nerve fiber layer(pRNFL),macular retinal nerve fiber layer(mRNFL),and ganglion cell layer(GCL)also decreased.OCTA indicated that the superficial and deep vascular density decreased,the foveal avascular zone(FAZ)area enlarged,and the acircularity index(AI)reduced in AGM individuals.Conclusions:Retinal thinning and microvascular lesions have occurred before the advent of clinically detectable DR;OCT and OCTA may have the potential to detect these preclinical changes.Registration:PROSPERO;http://www.crd.york.ac.uk/prospero/;No.CRD42021269885.展开更多
In the practical magneto opticaldisk productionline,alloysputteringtargetisalwaysusedtosputter recording film , whileinlaid targetisrarely used .In ourlaboratory,a seriesof al loy targets forsputtering magneto- opti...In the practical magneto opticaldisk productionline,alloysputteringtargetisalwaysusedtosputter recording film , whileinlaid targetisrarely used .In ourlaboratory,a seriesof al loy targets forsputtering magneto- optical recording film were prepared and theeffect ofcomposition andsputtering parameterson magneto opticalpropertiesarestudied . Thesputter ing rateof Al,Siand Tb Fe Co( Mo) undertheconditionsof differentsputtering powerandN2 Argasflux weredetermined and baseontheresults,a variablecomposition andthickness of SiNcan beobtained by meansof regulating sputtering power and gasflux, kindsof Mosputtering filmsareobtained under differentsputtering power and gasflux, and Kerrloop lineofthese magneto opticalfilmsare measuredto acquiretheir propertiessuch as Kerrrota tion,then ,theeffectofsputteringtechnology on Kerrrotationisdiscussed .展开更多
Purpose:To report a case of Leber hereditary optic neuropathy combined with fibrous boney dysplasia. Methods: Case report. Results:A 16-year-old boy presented with painless vision loss in both eyes. He had a history o...Purpose:To report a case of Leber hereditary optic neuropathy combined with fibrous boney dysplasia. Methods: Case report. Results:A 16-year-old boy presented with painless vision loss in both eyes. He had a history of a right humerus fracture and right femoral fracture surgery after an uncomplicated fall.On examination in our clinic, his visual acuity was counting fingers at 20 cm OD and counting fingers at 40 cm OS.Both pupils reacted sluggishly to light.The findings on slit-lamp examination and funduscopy after pupillary dilation were all unremarkable. Computed tomography scans demonstrated fibrous dysplasia involving the right frontal, temporal, parietal, and occipital bones but no stenosis of either optic canal. His serum alkaline phosphatase was 522 U/L (reference range: 40-150 U/L). His vision showed no improvement after intravenous methylprednisolone pulse therapy.Finally,a 11778 mitochondrial DNA mutation was detected. He still had no visual recovery after treatment with oral coenzyme Q10,vitamin B1, and citicoline. Conclusion:Fibrous dysplasia of bone may be associated with Leber hereditary optic neuropathy,possibly due to the fact that it increases local oxygen consumption. (Eye Science 2013; 28:48-50)展开更多
基金National Natural Science Foundation of China(61701029)。
文摘To improve the detection accuracy and robustness of crowd anomaly detection,especially crowd emergency evacuation detection,the abnormal crowd behavior detection method is proposed.This method is based on the improved statistical global optical flow entropy which can better describe the degree of chaos of crowd.First,the optical flow field is extracted from the video sequences and a 2D optical flow histogram is gained.Then,the improved optical flow entropy,combining information theory with statistical physics is calculated from 2D optical flow histograms.Finally,the anomaly can be detected according to the abnormality judgment formula.The experimental results show that the detection accuracy achieved over 95%in three public video datasets,which indicates that the proposed algorithm outperforms other state-of-the-art algorithms.
文摘Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters.A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer(RNFL) thickness and the optic disc tomography by spectraldomain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma(POAG).Methods:.This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control(n=51, 98 eyes), suspected glaucoma(n=81,.146 eyes), and POAG groups(n=55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness,.disc area(DA), cup area(CA), rim area(RA), disc volume(DV),cup volume(CV), rim volume(RV), cup / disc area ratio(CA / DA), rim / disc area ratio(RA / DA), cup / disc volume ratio(CV / DV) and rim / disc volume ratio(RV / DV).Results: Superior, nasal, and mean RNFL parameters, DA,CA,RA, DV, CV, CA / DA, RA / DA, CV / DV and RV / DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group,.the maximum area under the ROC curve(AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA / DA(0.998), followed by CA / DA(0.997). The AROC of CA, RA, CV, and DV were all > 0.900.Conclusion:.OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG.
文摘Detection of polystyrene beads with a diameter of 100 nm was conducted using an optical disk drive tester equipped with a laser of 405 nm wavelength and an objective lens with a numerical aperture of 0.65. The polystyrene beads were used to mimic the influenza virus. A grooved disk with a (ZnS)85(SiO2)15/SiO2 layered surface structure was used for the detection. The detection of influenza viruses (A/Udorn/307/1972) with Au nanoparticles was also demonstrated using the optical disk drive tester. In this case, a grooved disk with an indium tin oxide (ITO) film was used. The ITO film functioned both to tune the reflectance of the disk and as an electrically conductive layer for scanning electron microscopy. In both cases, the target substances were successfully recognized in a single scan with a high scanning speed of 4.9 m/s. The results indicate that this optical disk system can be used to detect 100 nm scale substances like influenza viruses, which are smaller than the diffraction limit of the system.
文摘This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal disk. The three ways including MO media, recordingmethod and readout method for increasing the disk ca- pacity havebeen discussed. Moreover, the importance with the exchange-coupledeffect between the magnetic layers and recording domain morphology isemphasized.
文摘Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 eyes) of normal subjects, 17 cases (34 eyes) of patients with big-cupped disk and 19 cases (37 eyes) of patients with POAG underwent Heidelberg Retina Tomograph (HRT) examination to get topography images and stereometric parameters of optic nerve head.Results: The stereometric parameters of optic nerve head of the normal, patients with big-cupped disk and POAG were 1) disk area (mm2): 1. 995± 0. 501, 2. 407±0. 661 and 2. 248±0.498; 2) cup area (mm2): 0.573±0.264, 1. 095±0. 673 and 1. 340±0. 516; 3) cup/disk ratio: 0. 25±0. 095, 0. 428±0. 176 and 0. 589±0.195; 4) rim area (mm2): 1.461±0.328, 1.312±0.418 and 0. 905± 0.409; 5)cup volume (mm3): 0. 108±0. 073, 0. 347±0. 346 and 0. 550 ±0. 394; 6) rim volume (mm3): 0. 421±0. 111, 0. 378±0. 225 and 0. 224±0. 189; 7) mean cup
文摘针对变电一次设备状态监测中普遍存在的异常数据问题,提出了一种基于点排序识别聚类结构(Ordering Points to Identify the Clustering Structure,OPTICS)的状态监测异常数据过滤算法。通过对一次设备状态监测的历史数据进行异常数据特征分析,建立了基于密度聚类的异常数据过滤机制。并以某110 k V变电站一次设备变压器油色谱以及GIS SF6密度微水实验为例,对该算法的异常数据检测效果进行了验证。该算法与传统异常数据过滤算法的对比试验结果表明,该算法能够准确地识别异常数据的特征,有效过滤状态监测中的异常数据,显著降低噪声干扰,从而提高数据的可靠性。
基金supported by the National Natural Science Foundation of China(81870665,82171063 to DC)the Natural Science Foundation of Sichuan Province(2022NSFSC1285 to XR).
文摘Background:Alterations in macular thickness and vascular density before clinically visible diabetic retinopathy(DR)remain inconclusive.This study aimed to determine whether retinal manifestations in abnormal glucose metabolism(AGM)patients differ from those in the healthy individuals.Methods:PubMed,Embase,and Web of Science were searched between 2000 and 2021.The eligibility criteria were AGM patients without DR.Primary and secondary outcomes measured by optical coherence tomography(OCT)and OCT angiography(OCTA)were analyzed and expressed as standardized mean differences(SMDs)with 95%confidence intervals(CIs).A random-effects model was used in the data synthesis.The potential publication bias for the variables was evaluated using Egger’s test.Results:A total of 86 observational studies involving 13,773 participants and 15,416 eyes were included.OCT revealed that compared to healthy controls,the total macular thickness of AGM patients was thinner,including the thickness of fovea(-0.24,95%CI[-0.39,-0.08];P=0.002,I^(2)=87.7%),all regions of parafovea(-0.32,95%CI[-0.54,-0.11];P=0.003;I^(2)=71.7%)and the four quadrants of perifovea;the thickness of peripapillary retinal nerve fiber layer(pRNFL),macular retinal nerve fiber layer(mRNFL),and ganglion cell layer(GCL)also decreased.OCTA indicated that the superficial and deep vascular density decreased,the foveal avascular zone(FAZ)area enlarged,and the acircularity index(AI)reduced in AGM individuals.Conclusions:Retinal thinning and microvascular lesions have occurred before the advent of clinically detectable DR;OCT and OCTA may have the potential to detect these preclinical changes.Registration:PROSPERO;http://www.crd.york.ac.uk/prospero/;No.CRD42021269885.
文摘In the practical magneto opticaldisk productionline,alloysputteringtargetisalwaysusedtosputter recording film , whileinlaid targetisrarely used .In ourlaboratory,a seriesof al loy targets forsputtering magneto- optical recording film were prepared and theeffect ofcomposition andsputtering parameterson magneto opticalpropertiesarestudied . Thesputter ing rateof Al,Siand Tb Fe Co( Mo) undertheconditionsof differentsputtering powerandN2 Argasflux weredetermined and baseontheresults,a variablecomposition andthickness of SiNcan beobtained by meansof regulating sputtering power and gasflux, kindsof Mosputtering filmsareobtained under differentsputtering power and gasflux, and Kerrloop lineofthese magneto opticalfilmsare measuredto acquiretheir propertiessuch as Kerrrota tion,then ,theeffectofsputteringtechnology on Kerrrotationisdiscussed .
文摘Purpose:To report a case of Leber hereditary optic neuropathy combined with fibrous boney dysplasia. Methods: Case report. Results:A 16-year-old boy presented with painless vision loss in both eyes. He had a history of a right humerus fracture and right femoral fracture surgery after an uncomplicated fall.On examination in our clinic, his visual acuity was counting fingers at 20 cm OD and counting fingers at 40 cm OS.Both pupils reacted sluggishly to light.The findings on slit-lamp examination and funduscopy after pupillary dilation were all unremarkable. Computed tomography scans demonstrated fibrous dysplasia involving the right frontal, temporal, parietal, and occipital bones but no stenosis of either optic canal. His serum alkaline phosphatase was 522 U/L (reference range: 40-150 U/L). His vision showed no improvement after intravenous methylprednisolone pulse therapy.Finally,a 11778 mitochondrial DNA mutation was detected. He still had no visual recovery after treatment with oral coenzyme Q10,vitamin B1, and citicoline. Conclusion:Fibrous dysplasia of bone may be associated with Leber hereditary optic neuropathy,possibly due to the fact that it increases local oxygen consumption. (Eye Science 2013; 28:48-50)