The development,application,communication protocol and system structure of an airborne data bus system are discussed in this paper with emphasis on the design of hardware, software and optical fiber transmission syste...The development,application,communication protocol and system structure of an airborne data bus system are discussed in this paper with emphasis on the design of hardware, software and optical fiber transmission system of the bus controller and remote terminal. Some experiments and their results are also given in this paper.展开更多
In this paper, we present a comparison of different light-emitting diodes (LEDs) as the light source for long path differential optical absorption spectroscopy (LP-DOAS) atmospheric trace gas measurements. In our ...In this paper, we present a comparison of different light-emitting diodes (LEDs) as the light source for long path differential optical absorption spectroscopy (LP-DOAS) atmospheric trace gas measurements. In our study, we use a fiberoptic design, where high power LEDs used as the light source are coupled into the telescope using a Y shape fiber bundle. Two blue and one ultraviolet (UV) LEDs with different emission wavelength ranges are tested for NO2 and SO2 measurements. The detailed description of the instrumental setup, the NO2 and SO2 retrieval procedure, the error analysis, and the preliminary results from the measurements carried out in Science Island, Hefei, Anhui, China are presented. Our first measurement results show that atmospheric NO2 and SO2 have strong temporal variations in that area and that the measurement accuracy is strongly dependent on the visibility conditions. The measured NO2 and SO2 data are compared to the Ozone Monitoring Instrument (OMI) satellite observations. The results show that the OMI NO2 product underestimates the ground level NO2 by 45%, while the OMI SO2 data are highly influenced by clouds and aerosols, which can lead to large biases in the ground level concentrations. During the experiment, the mixing ratios of the atmospheric NO2 and SO2 vary from 8 ppbv to 36 ppbv and from 3 ppbv to 18 ppbv, respectively.展开更多
A CWDM is proposed for fiber optic communication networks. The OADM is designed based on SOI structure. The scheme for CWDM optical signal protection is presented.
This paper describes a new design for the test light source of an L/U-band extended optical fiber line testing system and the side-band suppresser ratio of the test light should be more than 70 dB.
文摘The development,application,communication protocol and system structure of an airborne data bus system are discussed in this paper with emphasis on the design of hardware, software and optical fiber transmission system of the bus controller and remote terminal. Some experiments and their results are also given in this paper.
基金Project supported by the National High-Technology Research and Development Program of China (Grant No. 2009AA063006)the National Natural Science Foundation of China (Grant No. 60808034)
文摘In this paper, we present a comparison of different light-emitting diodes (LEDs) as the light source for long path differential optical absorption spectroscopy (LP-DOAS) atmospheric trace gas measurements. In our study, we use a fiberoptic design, where high power LEDs used as the light source are coupled into the telescope using a Y shape fiber bundle. Two blue and one ultraviolet (UV) LEDs with different emission wavelength ranges are tested for NO2 and SO2 measurements. The detailed description of the instrumental setup, the NO2 and SO2 retrieval procedure, the error analysis, and the preliminary results from the measurements carried out in Science Island, Hefei, Anhui, China are presented. Our first measurement results show that atmospheric NO2 and SO2 have strong temporal variations in that area and that the measurement accuracy is strongly dependent on the visibility conditions. The measured NO2 and SO2 data are compared to the Ozone Monitoring Instrument (OMI) satellite observations. The results show that the OMI NO2 product underestimates the ground level NO2 by 45%, while the OMI SO2 data are highly influenced by clouds and aerosols, which can lead to large biases in the ground level concentrations. During the experiment, the mixing ratios of the atmospheric NO2 and SO2 vary from 8 ppbv to 36 ppbv and from 3 ppbv to 18 ppbv, respectively.
文摘A CWDM is proposed for fiber optic communication networks. The OADM is designed based on SOI structure. The scheme for CWDM optical signal protection is presented.
文摘This paper describes a new design for the test light source of an L/U-band extended optical fiber line testing system and the side-band suppresser ratio of the test light should be more than 70 dB.