A new type of double function optical circulator for double fibers is proposed in this paper. Two fiber tips and lens twice are employed in this kind of device as the coupling system for what is believed to be the fir...A new type of double function optical circulator for double fibers is proposed in this paper. Two fiber tips and lens twice are employed in this kind of device as the coupling system for what is believed to be the first time. Because two fiber tips and lens twice are used, the function of optical circulator is duplicated in comparison with conventional optical circulator with single fiber tip. Thus the optical circulator has a low cost and a small volume comparatively. Excess loss of the coupling system and the misalignment of the lens twice in angular error and the position error to the developed circulator are analyzed and discussed by using Gauss wave and double integral in theory. The analysis results show that the excess loss is zero when each distance is equal to f between every adjacent: fraction and without misalignment error in the coupling system. In addition, the excess loss is increasing with increment of the distance error and the angular error. The errors of the angular of the optical axis to lens and the distance between the SL to lens are the main source of the excess loss. The higher the errors are, the higher the excess loss is. It's very important for reducing the misalignment errors in the coupling system with high ratio of coupling to achieve low excess loss. Details of design and excess loss in the coupling system of this circulator are presented.展开更多
文摘A new type of double function optical circulator for double fibers is proposed in this paper. Two fiber tips and lens twice are employed in this kind of device as the coupling system for what is believed to be the first time. Because two fiber tips and lens twice are used, the function of optical circulator is duplicated in comparison with conventional optical circulator with single fiber tip. Thus the optical circulator has a low cost and a small volume comparatively. Excess loss of the coupling system and the misalignment of the lens twice in angular error and the position error to the developed circulator are analyzed and discussed by using Gauss wave and double integral in theory. The analysis results show that the excess loss is zero when each distance is equal to f between every adjacent: fraction and without misalignment error in the coupling system. In addition, the excess loss is increasing with increment of the distance error and the angular error. The errors of the angular of the optical axis to lens and the distance between the SL to lens are the main source of the excess loss. The higher the errors are, the higher the excess loss is. It's very important for reducing the misalignment errors in the coupling system with high ratio of coupling to achieve low excess loss. Details of design and excess loss in the coupling system of this circulator are presented.