期刊文献+
共找到139篇文章
< 1 2 7 >
每页显示 20 50 100
Bimodal imaging of proliferative diabetic retinopathy vascular features using swept source optical coherence tomography angiography 被引量:2
1
作者 Amal M Elbendary Hossam Youssef Abouelkheir 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第9期1528-1533,共6页
AIM: To categorize neovessels morphology and to detect response to anti-angiogenic therapy by using structural and angiographic modes of swept source optical coherence tomography(SS-OCT).METHODS: Thirty-two eyes w... AIM: To categorize neovessels morphology and to detect response to anti-angiogenic therapy by using structural and angiographic modes of swept source optical coherence tomography(SS-OCT).METHODS: Thirty-two eyes with neovessels at disc(NVD) and neovessels elsewhere(NVE)-as diagnosed by fluorescein angiography-were included. Cross sectional OCT images of disc and macular regions were registered to enface OCT angiography(OCTA), B-scan blood flow over lay and density maps. Three eyes received antiangiogenic treatment.RESULTS: Pin point registration of cross-sectional OCT and OCTA images differentiated active NVD with vascular elements from fibrous or equivalent fibrovascular elements. En face images delineated NVE as vascular tufts or area of filling while cross-sectional images differentiated NVE from microvascular intraretinal abnormality(IRMA). All cases were associated with enlargement of foveal avascular zone and or areas of capillary non perfusion. Regressed NVD appeared as ghost vessel or pruned vascular loops after injection.CONCLUSION: Structural and angiographic modes of SS-OCT can detect, characterize and categorize the pattern of wide spectrum of neovessels based on blood flow data and density maps. It is potentially useful to detect ischemic changes in the vascular bed and regression of NVD after therapeutic regimens providing substitute for invasive techniques. 展开更多
关键词 optical coherence tomography ANGIOGRAPHY swept proliferative diabetic retinopathy
下载PDF
Observation of the early blood vessels of cutaneous malignant melanoma using Swept Source Optical Coherence Tomography A ngiography(SS-OCTA) 被引量:1
2
作者 Jingxuan Liu Jinyu Fan +4 位作者 Quan Wang Wen He Caihua Dong Minxuan Sun Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2019年第4期105-115,共11页
Melanoma,characterized by high mortality,rapid development and accompanied with angio-genesis is the most typical malignant tumor in skin cancer.Hence,the detection of blood vessels is of much significanoe.The early v... Melanoma,characterized by high mortality,rapid development and accompanied with angio-genesis is the most typical malignant tumor in skin cancer.Hence,the detection of blood vessels is of much significanoe.The early vascular network has small scale.If we remove the tumor early and biopsy it,it will increase the spread of the cancer cells and infection and bleeding.In this case,we presented a new angiography method.A high-resolution OCT system for noninvasive an-giographic imaging of early skin melanoma-Swept Source Optical Coberence Tomography Angiography(SS-OCTA)is proposed.With a high lateral resolution of 10pm in vrivo tomographic angiography,SS-OCTA is used to image and identify the morphology of the early tumor blood vessels.In addition,a control group experiment is conducted to observe the growth of melanoma in the process of rupture,malormation of micro-vessels.The results of the analysis and statistical test(P<0.05)are statistically signifcant. 展开更多
关键词 MELANOMA swept source optical coberence tomography angiography early vessels
下载PDF
Renal function and choroidal thickness using swept-source optical coherence tomography in diabetic patients
3
作者 Antonio Manuel Garrido-Hermosilla Mariola Méndez-Muros +6 位作者 Estanislao Gutiérrez-Sánchez Cristóbal Morales-Portillo María Jesús Díaz-GrANDa Eduardo Esteban-González Isabel Relimpio-López María Asunción Martínez-Brocca Enrique Rodríguez-de-la-Rúa-Franch 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第6期985-989,共5页
AIM: To assess the relationship between choroidal thickness and renal function in diabetic patients. METHODS: Cross-sectional retrospective clinical study of 42 eyes of 21 ocular treatment-na?ve diabetic patients. Dem... AIM: To assess the relationship between choroidal thickness and renal function in diabetic patients. METHODS: Cross-sectional retrospective clinical study of 42 eyes of 21 ocular treatment-na?ve diabetic patients. Demographic data included: age, sex, type and course of diabetes. Ocular data included: severity of diabetic retinopathy;retinal thickness at the central macular region, as well as choroidal thickness at the central and paracentral quadrants, using automatically generated maps by swept-source optical coherence tomography;presence of cystic macular edema;and ocular axial length(AXL). Lab-test parameters included: glycated hemoglobin(HbA1c), albuminuria, albumin/creatinine ratio in urine, and glomerular filtration rate. RESULTS: A significant negative correlation was mainly observed between several choroidal thicknesses, age(P<0.020) and ocular AXL(P<0.030). On the contrary, a significant positive correlation was found between all choroidal thicknesses, HbA1 c(P<0.035) and albuminuria(P<0.040). CONCLUSION: Choroidal thickness can represent an additional tool to help clinicians predicting the renal status in ocular treatment-na?ve diabetic patients. 展开更多
关键词 choroidal thickness renal function swept-source optical coherence tomography SPECTRAL-DOMAIN optical coherence tomography diabetes MELLITUS
下载PDF
High-Speed Optical Coherence Tomography System Using a 200-kHz Swept Light Source with a KTN Deflector
4
作者 Yuichi Okabe Yuzo Sasaki +4 位作者 Masahiro Ueno Takashi Sakamoto Seiji Toyoda Junya Kobayashi Masato Ohmi 《Optics and Photonics Journal》 2013年第2期190-193,共4页
We demonstrate a high-speed swept-source optical coherence tomography (SS-OCT) system, which is based on a high-speed swept light source and a Mach-Zehnder interferometer with a high-speed photodetector. The light sou... We demonstrate a high-speed swept-source optical coherence tomography (SS-OCT) system, which is based on a high-speed swept light source and a Mach-Zehnder interferometer with a high-speed photodetector. The light source is an external-cavity laser tuned by a KTN electro-optic deflector, which exhibits a very fast response and large deflection. The scanning wavelength range is almost 80 nm up to 200 kHz with a ±400-V deflector driving voltage. The system acquires 1 mm × 1 mm images consisting of 200 × 200 pixels within few milliseconds. We present preliminary SS-OCT images of an in-vitro human nail and an in-vivo finger pad. 展开更多
关键词 swept-source optical coherence tomography KTN New Light source
下载PDF
Comparing imaging capabilities of spectral domain and swept source optical coherence tomography angiography in healthy subjects and central serous retinopathy 被引量:1
5
作者 Fupeng Wang Qinqin Zhang +2 位作者 Anthony J.Deegan Jun Chang Ruikang K.Wang 《Eye and Vision》 SCIE 2018年第1期182-190,共9页
Background:There are two forms of system implementation of optical coherence tomography angiography(OCTA)in ophthalmic imaging,i.e.,spectral domain(SD-)and swept source OCTA(SS-OCTA).The purpose of this paper is to co... Background:There are two forms of system implementation of optical coherence tomography angiography(OCTA)in ophthalmic imaging,i.e.,spectral domain(SD-)and swept source OCTA(SS-OCTA).The purpose of this paper is to compare the SD-OCTA and SS-OCTA for elucidating structural and vascular features associated with central serous retinopathy(CSR),and to evaluate the effects of CSR on SD-and SS-OCTA’s imaging capabilities.Methods:Normal subjects and CSR patients were imaged by SD-and SS-OCTA using 3×3 mm and 6×6 mm scan patterns.OCT signal strengths at the superficial retina,deep retina,Sattler’s layer and Haller’s layer were used to compare the ability of SD-and SS-OCTA to image structural features.In addition,the ability to acquire angiograms were discussed by evaluating retinal vessel density.Central serous volume(CSV)was measured and it was correlated with difference in signal strengths(ΔS)between two OCTA devices.Results:Seven normal eyes and seven diseased eyes were recruited.Results showed no significant differences between SD-and SS-OCT in detecting structural features of the retinal layer according to the paired t-test.However,when imaging the Sattler’s layer for normal eyes,a significant difference is found between SD-and SS-OCT(p<0.0001 for 3×3 mm scan,and p=0.0002 for 6×6 mm);while for CSR eyes,the corresponding values were p<0.0001 and p=0.0003,respectively.At Haller’s layer for normal eyes,the corresponding values were p=0.0004 and p=0.0014;and for CSR eyes,p=0.0004 and p<0.0001,respectively.A strong correlation betweenΔS and CSV was observed in the Sattler’s layer(3×3 mm–p=0.0031 and R^(2)=0.951;6×6 mm–p=0.0075 and R^(2)=0.911)and Haller’s layer(3×3 mm–p=0.0026 and R^(2)=0.955;6×6 mm–p=0.0013 and R^(2)=0.972).Conclusions:The results suggest no differences between SD-and SS-OCTA for imaging the retinal layers however,when imaging beyond retinal layers,SS-OCTA appears advantageous in detecting returning signals.In CSR cases,the CSV may have an impact on sub-CSR tissue imaging and appears to have more impact on SD-than SS-OCTA. 展开更多
关键词 optical coherence tomography Spectral domain OCTA swept source OCTA Central serous retinopathy Signal strength Central serous volume
原文传递
1.3μm broadband swept sources with enhanced nonlinear effects
6
作者 Panqiu Jiang Jiale Mu +2 位作者 Yuxing Liu Pinghe Wang Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第3期124-131,共8页
In this work,a new structure is used to enhance the nonlinear effect in the cavity,which improvesthe performance of the 1.3μm broadband swept source.The swept source adopts a semiconductoroptical amplifier(SOA),a cir... In this work,a new structure is used to enhance the nonlinear effect in the cavity,which improvesthe performance of the 1.3μm broadband swept source.The swept source adopts a semiconductoroptical amplifier(SOA),a circulator,a coupler,and a tunable filter.In the structure,the lightpasses through the nonlinear medium(SOA)twice in two opposite directions,which excites thenonlinear ffect and increases the performance of the swept source.The tunable filter is based on apolygon rotating mirror and gratings.Traditionally,multiple SOAs are adopted to improve thesweep range and the optical power,which increases the cost and complexity of the swept source.The method proposed in this paper can improve the spectral range and optical power of the sweptsources without additional accessories.For the short-cavity swept source,the power increasesfrom 6 mW to 7.7 mW,and the sweep range increases from 98 nm to 120 nm.The broadband swept sources could have wide applications in biomedical imaging,sensor system,measurementand so on. 展开更多
关键词 optical coherence tomography swept source enhanced nonlinear effects
下载PDF
Effect of orthokeratology on precision and agreement assessment of a new sweptsource optical coherence tomography biometer 被引量:1
7
作者 Bao Shu Fangjun Bao +6 位作者 Giacomo Savini Weicong Lu Ruixue Tu Haisi Chen Benhao Song Qinmei Wang Jinhai Huang 《Eye and Vision》 SCIE CSCD 2020年第1期119-127,共9页
Background:To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography(SS-OCT)optical biometer(OA-2000),and agreement between its measuremen... Background:To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography(SS-OCT)optical biometer(OA-2000),and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry(PCI).Methods:This study recruited fifty-one eyes of 51 normal children(8–16 years).An operator took measurements with the two biometers.Then,a second operator took measurements with the SS-OCT biometer.After orthokeratology was performed for one month,the same operators repeated the same procedures.Axial length(AL),mean keratometry(Km)at 2.5 mm and 3.0 mm diameters(Km2.5 and Km3.0),central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT)and corneal diameter(CD)were analyzed.Results:With the SS-OCT optical biometer,the test-retest repeatability of AL measurements was<0.06 mm.For all parameters,the coefficients of variation were<1.23%and the intraclass correlation coefficients were>0.95.The 95%limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm.After orthokeratology,the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology,while the absolute values of difference for AL,Km2.5,ACD and CD measurements were comparable.Conclusions:Before and after orthokeratology,the SS-OCT biometer showed high repeatability and reproducibility for all measurements.Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements.The CD measurement showed poor agreement between the two devices. 展开更多
关键词 swept source optical coherence tomography ORTHOKERATOLOGY PRECISION AGREEMENT CHILDREN
原文传递
Fourier domain optical coherence tomography with ultralong depth range 被引量:2
8
作者 Zhihua DING Yi SHEN Wen BAO Peng LI 《Frontiers of Optoelectronics》 CSCD 2015年第2期163-169,共7页
The depth ranges of typical implementations of Fourier domain optical coherence tomography (FDOCT), including spectral domain OCT (SDOCT) and swept source OCT (SSOCT), are limited to several millimeters. To exte... The depth ranges of typical implementations of Fourier domain optical coherence tomography (FDOCT), including spectral domain OCT (SDOCT) and swept source OCT (SSOCT), are limited to several millimeters. To extend the depth range of current OCT systems, two novel systems with ultralong depth range were developed in this study. One is the orthogonal dispersive SDOCT (OD-SDOCT), and the other is the recirculated swept source (R-SS) interferometer/OCT. No compromise between depth range and depth resolution is required in both systems. The developed OD-SDOCT system realized the longest depth range (over 100 mm) ever achieved by SDOCT, which is ready to be modified for depth-encoded parallel imaging on multiple sites. The developed R-SS interferometer achieved submicron precision within a depth range of 30mm, holding potential in real-time contact-free on-axis metrology of complex optical sys- tems. 展开更多
关键词 optical coherence tomography (OCT) vir-tually-imaged phased array (VIPA) orthogonal dispersion swept source light recirculation parallel imaging dimen-sional metrology
原文传递
扫频源光学相干断层扫描血管成像在眼科临床中的应用进展 被引量:1
9
作者 王曦 黄潇颖 +1 位作者 周言 郑政 《国际眼科杂志》 2024年第2期255-259,共5页
扫频源光学相干断层扫描血管成像(SS-OCTA)检查是近几年提出的一种新型血管成像技术,具有非侵入性、快速、高分辨率、自动化血管分层成像等优势,在眼科相关疾病的早期诊断、疗效评估及监测疾病进展等方面具有很高的价值。基于OCTA的基础... 扫频源光学相干断层扫描血管成像(SS-OCTA)检查是近几年提出的一种新型血管成像技术,具有非侵入性、快速、高分辨率、自动化血管分层成像等优势,在眼科相关疾病的早期诊断、疗效评估及监测疾病进展等方面具有很高的价值。基于OCTA的基础,SS-OCTA采用快速调谐的激光器和1050 nm的波长,穿透力更强,对视网膜和脉络膜微血管系统进行无创深度分辨成像,加深了对多种眼部疾病(眼底病变、青光眼、神经退行性疾病等)特征的认识。此外,SS-OCTA也可用于研究眼前节结构,如角膜新生血管的深度和密度、虹膜新生血管治疗前后的变化等。该技术为眼科临床实践提供了一种新的手段。本文就SS-OCTA技术在眼科临床的应用进展进行综述。 展开更多
关键词 扫频源光学相干断层扫描血管成像 眼底血管造影 诊断 应用
下载PDF
基于扫频OCT测量的术前晶状体界面位置对于白内障术后人工晶状体真实位置的预测价值
10
作者 李晨 《眼科新进展》 CAS 北大核心 2024年第9期728-733,共6页
目的 探讨基于扫频OCT(SS-OCT)技术的光学生物测量仪IOLMaster 700获得的晶状体界面位置(IIP)对白内障术后人工晶状体(IOL)的真实位置(ALP)的预测价值。方法 回顾性描述性研究。选取2021年7月至2022年7月于苏州大学附属第一医院眼科接... 目的 探讨基于扫频OCT(SS-OCT)技术的光学生物测量仪IOLMaster 700获得的晶状体界面位置(IIP)对白内障术后人工晶状体(IOL)的真实位置(ALP)的预测价值。方法 回顾性描述性研究。选取2021年7月至2022年7月于苏州大学附属第一医院眼科接受白内障手术的年龄相关性白内障患者208例208眼为研究对象。根据植入的IOL不同分为2组:IQ组(80眼)术中植入IQ IOL;ZCB组(128眼)术中植入ZCB IOL。使用基于SS-OCT的生物测量仪IOLMaster 700在术前和术后3个月对患眼进行生物学参数的测量,获取ALP、术后前房深度(ACD)、IOL厚度等参数,并计算IOL位置误差。结果 白内障术后,208眼的绝对屈光度预测误差(ARPE)为(0.43±0.35) D,134眼(64.4%)的ARPE<0.50 D。与IQ组相比,ZCB组患眼的ALP和ALP2值更大(均为P<0.001)。与IQ组相比,ZCB组ARPE≥0.50 D患眼的IIP显著降低(P=0.028);在ZCB组患者中,与ARPE<0.50 D相比,ARPE≥0.50 D患眼的IIP显著降低(P=0.041)。两组患者的ALP与IIP均具有较好的相关性(IQ组:r=0.815,P<0.001;ZCB组:r=0.757,P<0.001);ALP2与IIP也均具有较好的相关性(IQ组:r=0.797,P<0.001;ZCB组:r=0.743,P<0.001)。通过IIP和术前参数可以获得线性表达式来预测ALP(IQ组、ZCB组的R^(2)分别为0.70、0.68)。结论 基于SS-OCT技术的IOL Master 700测量的IIP位置与白内障术后的ALP相关,可用于优化IOL度数计算。 展开更多
关键词 人工晶状体 扫频OCT 年龄相关性白内障 晶状体界面位置
下载PDF
不同程度DR对三维脉络膜血管指数变化的影响及其意义 被引量:1
11
作者 纪风涛 王慧 +4 位作者 李永蓉 戴维 魏科 王志敏 廖荣丰 《中华实验眼科杂志》 CAS CSCD 北大核心 2024年第8期736-743,共8页
目的采用扫频源光学相干断层扫描血管成像(SS-OCTA)测量糖尿病患者三维脉络膜血管指数(3D CVI)并评估其与不同程度糖尿病视网膜病变(DR)的关系。方法采用横断面研究方法,纳入2022年3—12月在合肥市第二人民医院就诊的139名受试者139眼,... 目的采用扫频源光学相干断层扫描血管成像(SS-OCTA)测量糖尿病患者三维脉络膜血管指数(3D CVI)并评估其与不同程度糖尿病视网膜病变(DR)的关系。方法采用横断面研究方法,纳入2022年3—12月在合肥市第二人民医院就诊的139名受试者139眼,包括糖尿病患眼115眼和无糖尿病对照眼24眼。根据早期治疗糖尿病视网膜病变研究标准七视野彩色眼底图像对DR进行分级,将糖尿病患眼分为无DR组34眼、非增生性糖尿病视网膜病变(NPDR)组42眼、NPDR合并糖尿病黄斑水肿(DME)组21眼和增生性糖尿病视网膜病变(PDR)组18眼。采用SS-OCTA扫描以黄斑中心凹为中心3 mm×3 mm区域,利用仪器内置软件分别测量黄斑中心凹1 mm(C1)及旁中心凹3 mm(C3)3D-CVI、脉络膜血管体积(CVV)、脉络膜间质体积和脉络膜厚度;旁中心凹进一步分为上方、下方、颞侧、鼻侧区域,测量其3D CVI。3D CVI定义为CVV与脉络膜总体积的比值。比较各组间不同区域脉络膜参数差异;采用多重线性回归分析评估3D CVI的影响因素。结果各组受检眼3D CVI-C1和3D CVI-C3总体比较差异均有统计学意义(F=3.103、3.036,均P<0.05),其中PDR组3D CVI-C1小于无DR组,3D CVI-C3小于对照组和无DR组,差异均有统计学意义(均P<0.05)。各组受检眼旁中心凹下方和鼻侧3D CVI总体比较差异均有统计学意义(F=2.714、4.020,均P<0.05),其中PDR组下方3D CVI小于无DR组,PDR组鼻侧3D CVI均小于对照组、无DR组、NPDR组和NPDR合并DME组,差异均有统计学意义(均P<0.05)。多重线性回归分析显示控制年龄、病程和糖化血红蛋白后,DR病变程度是中心凹及旁中心凹3D CVI的影响因素,PDR眼对中心凹及旁中心凹3D CVI影响最大,与无DR眼相比,PDR眼中心凹3D CVI降低0.019(95%CI:-0.031~-0.007,P=0.003),旁中心凹3D CVI降低0.019(95%CI:-0.030~-0.008,P=0.001);与无DR眼相比,NPDR合并DME眼中心凹3D CVI降低0.014(95%CI:-0.027~0.000,P=0.044)。结论黄斑中心凹3D CVI与DR严重程度有关,黄斑区脉络膜中大血管3D CVI的降低可能是DR加重的敏感指标。 展开更多
关键词 糖尿病 糖尿病视网膜病变 脉络膜 扫频源光学相干断层扫描血管成像 三维脉络膜血管指数
下载PDF
超广域SS-OCTA联合超广角激光扫描眼底成像对糖尿病视网膜病变的诊断价值 被引量:2
12
作者 毛明珠 黎梦宇 +4 位作者 韦丁杨 陈丽 刘逸 李杰 钟捷 《眼科新进展》 CAS 北大核心 2024年第4期291-296,共6页
目的 超广域扫频源光学相干断层扫描血管成像(UWF SS-OCTA)联合超广角激光扫描眼底成像(UWF SLO)对糖尿病视网膜病变(DR)患者病变的检出率以及对DR分级诊断价值的研究。方法 横断面研究。招募在四川省人民医院眼科就诊的糖尿病患者。所... 目的 超广域扫频源光学相干断层扫描血管成像(UWF SS-OCTA)联合超广角激光扫描眼底成像(UWF SLO)对糖尿病视网膜病变(DR)患者病变的检出率以及对DR分级诊断价值的研究。方法 横断面研究。招募在四川省人民医院眼科就诊的糖尿病患者。所有参与者都接受了UWF SS-OCTA、UWF SLO和荧光素眼底血管造影(FFA)检查,用于检测DR病变,包括微动脉瘤(MA)、视网膜内出血(IRH)、视网膜无灌注区(NPAs)、视网膜内微血管异常(IRMAs)、视网膜静脉串珠(VB)、视网膜新生血管(NVE)、视盘新生血管(NVD)及玻璃体积血(VH)。联合三类影像检查(以下简称三联影像)结果作为标准对照,对比不同影像两两联合对DR病变的检出率及对DR严重度分级的一致性。结果 共纳入101例175眼。与三联影像结果相比,UWF SS-OCTA联合UWF SLO对MA、IRH、NPAs、IRMAs、NVE、NVD及VH的检出率分别为91%、83%、77%、69%、27%、10%及12%,Kappa依次为0.812、1.000、1.000、1.000、0.986、0.970及1.000。与三联影像结果相比,UWF SS-OCTA联合UWF SLO对DR的严重度分级具有优异一致性(Kappa=0.943)。结论 UWF SS-OCTA联合UWF SLO能准确识别MA、IRH、NPAs、IRMAs、NVE、NVD及VH,对DR筛查及分级诊断准确性高,适用于临床上对DR的大规模筛查与管理。 展开更多
关键词 超广域扫频源光学相干断层扫描血管成像 超广角激光扫描眼底成像 荧光素眼底血管造影 糖尿病性视网膜病变
下载PDF
基于视网膜结构改变的机器学习对早期帕金森病诊断的预测价值研究 被引量:1
13
作者 梁可可 郭庆歌 +9 位作者 李晓欢 马建军 杨红旗 石小雪 范咏言 杨大伟 郭大帅 董琳瑞 古祺 李东升 《中国全科医学》 北大核心 2024年第9期1102-1108,共7页
背景帕金森病(PD)的诊断主要以临床症状为主,缺乏正确诊断的客观方法。目前已有关于视网膜结构改变作为PD早期诊断的生物标志的研究,但基于视网膜结构改变的机器学习对预测早期PD的研究尚少。目的基于视网膜结构改变的特征构建机器学习... 背景帕金森病(PD)的诊断主要以临床症状为主,缺乏正确诊断的客观方法。目前已有关于视网膜结构改变作为PD早期诊断的生物标志的研究,但基于视网膜结构改变的机器学习对预测早期PD的研究尚少。目的基于视网膜结构改变的特征构建机器学习模型,探索其在早期PD诊断中的预测价值,及探讨不同机器学习算法对PD早期诊断的准确性。方法选取2021年10月—2022年9月在河南省人民医院神经内科门诊就诊和住院治疗的年龄40~70岁的PD患者49例(PD组),并选取来医院体检的年龄及性别相匹配的39名健康者(健康对照组)为研究对象。所有研究对象行扫频源光学相关断层扫描和扫频源光学相干断层扫描血流成像检查,并定量分析黄斑区视网膜的厚度和血管密度。将88例受试者按7∶3的比例随机分为训练集62例和验证集26例,选择PD组与健康对照组差异有统计学意义的变量作为纳入机器学习模型的特征变量,并在训练集中分别构建Logistic回归(LR)、K-近邻算法(KNN)、决策树(DT)、随机森林(RF)和极端梯度提升(XGboost)模型。采用受试者工作特征(ROC)曲线下面积(AUC)、准确度、灵敏度和特异度评价基于视网膜改变的机器学习模型对早期PD诊断的预测价值。结果与健康对照组相比,PD组患者浅层毛细血管的上方外圈(A6)、颞侧外圈(A7)、下方外圈(A8)以及鼻侧外圈(A9)密度减少,视网膜层的上方内圈(A2)、颞侧内圈(A3)、下方内圈(A4)、鼻侧内圈(A5)、A6~A9厚度,节细胞复合体层的A9厚度,神经纤维层的A7厚度,视网膜外层的A2和A4~A9厚度变薄(P<0.05)。视网膜层A2厚度(OR=0.781,95%CI=0.659~0.926)、视网膜层A3厚度(OR=1.190,95%CI=1.019~1.390)、视网膜外层A2厚度(OR=0.748,95%CI=0.603~0.929)、视网膜外层A6厚度(OR=2.264,95%CI=1.469~3.490)、视网膜外层A8厚度(OR=0.723,95%CI=0.576~0.906)以及神经纤维层A7厚度变薄(OR=0.592,95%CI=0.454~0.773)及浅层毛细血管A7密度减少(OR=1.966,95%CI=1.399~2.765)为早期PD发生的独立危险因素(P<0.05)。将上述变量纳入并构建机器学习模型,结果显示,构建的5个模型中,LR模型整体性能最高,其AUC为0.841,而DT模型的准确度最高,其准确度为0.846。结论基于视网膜特征的机器学习模型可准确的预测早期PD,其中,DT模型对早期PD诊断具有较高的准确度。 展开更多
关键词 帕金森病 扫描源光学相干断层扫描 视网膜 机器学习 诊断 鉴别
下载PDF
SS-OCT在角膜成像中的应用进展
14
作者 赵丽丽 宋继科 +1 位作者 卢秀珍 毕宏生 《国际眼科杂志》 CAS 2024年第7期1058-1063,共6页
成像技术的进步彻底改变了眼科领域,改变了我们对眼科疾病的理解、诊断和治疗。扫频源光学相干断层扫描(SS-OCT)是一种最新的非接触式高分辨率成像技术。它进一步提高了成像深度和扫描速度,增加了新的算法和功能。SS-OCT允许对角膜结构... 成像技术的进步彻底改变了眼科领域,改变了我们对眼科疾病的理解、诊断和治疗。扫频源光学相干断层扫描(SS-OCT)是一种最新的非接触式高分辨率成像技术。它进一步提高了成像深度和扫描速度,增加了新的算法和功能。SS-OCT允许对角膜结构进行三维评估,提供角膜前、后表面的曲率和高度图以及角膜厚度图。这可以帮助眼科医生筛查和诊断角膜病变,如圆锥角膜、角膜营养不良和变性。SS-OCT更快、更精准和更灵敏的角膜测量有助于对即将进行角膜和屈光手术的患者做好术前计划和术后监测。文章总结SS-OCT技术的发展及其在角膜疾病中潜在的临床效用与在手术中的应用进展,以支持更多未来可能的研究和临床治疗。 展开更多
关键词 扫频源光学相干断层扫描(SS-OCT) 屈光手术 角膜移植 散光
下载PDF
基于SS-OCT/SS-OCTA探究玻璃体视网膜界面改变对2型糖尿病视网膜病变的影响
15
作者 卢佩瑶 陈若瑜 +1 位作者 曹丹 张良 《中山大学学报(医学科学版)》 CAS CSCD 北大核心 2024年第5期826-834,共9页
【目的】基于超广角扫频光学相干断层扫描(UWF SS-OCT)及超广角光学相干断层血管成像技术(UWF SS-OCTA)探讨玻璃体视网膜界面改变对2型糖尿病视网膜病变(DR)的影响。【方法】本研究以143例糖尿病患者作为研究对象,对258只眼睛的SS-OCT... 【目的】基于超广角扫频光学相干断层扫描(UWF SS-OCT)及超广角光学相干断层血管成像技术(UWF SS-OCTA)探讨玻璃体视网膜界面改变对2型糖尿病视网膜病变(DR)的影响。【方法】本研究以143例糖尿病患者作为研究对象,对258只眼睛的SS-OCT图像以及69个增殖期糖尿病视网膜病变(PDR)的SS-OCTA图像进行分析,运用Goodman-Kruskal’s Gamma方法评估玻璃体后脱离(PVD)与DR严重程度的关系,并统计不同PVD程度下PDR患眼视网膜新生血管的生长情况。【结果】随着DR严重程度进展,PVD的程度与DR的严重程度呈负相关(Gamma=-0.294,P<0.001),即玻璃体与视网膜粘连程度增加,DR程度更加严重。其中,糖尿病病程10年以上的患眼PVD程度与DR严重程度的负相关更加显著(Gamma=-0.620,P<0.001),且视网膜新生血管更倾向于在视网膜玻璃体粘连区域生长。【结论】玻璃体视网膜粘连程度与DR严重程度密切相关,在DR患者管理中运用SS-OCT评估玻璃体视网膜界面具有较高的应用价值。 展开更多
关键词 扫频源光学相干断层扫描/扫频源光学相干断层血管成像 糖尿病视网膜病变 玻璃体后脱离 玻璃体视网膜粘连 玻璃体视网膜界面
下载PDF
基于超广角SS-OCTA的高度近视患者脉络膜血管改变
16
作者 涂书 姚昱欧 +1 位作者 曾巧珠 赵明威 《中华实验眼科杂志》 CAS CSCD 北大核心 2024年第11期1020-1027,共8页
目的采用超广角扫频源光学相干断层扫描血管成像(SS-OCTA)评估高度近视患者三维脉络膜血管指数(3D-CVI)与脉络膜毛细血管血流密度(CCD)改变,进而探讨眼轴长度(AL)与高度近视脉络膜血管结构改变的关系。方法采用横断面研究设计,纳入2021... 目的采用超广角扫频源光学相干断层扫描血管成像(SS-OCTA)评估高度近视患者三维脉络膜血管指数(3D-CVI)与脉络膜毛细血管血流密度(CCD)改变,进而探讨眼轴长度(AL)与高度近视脉络膜血管结构改变的关系。方法采用横断面研究设计,纳入2021年11月至2022年10月于北京大学人民医院行24 mm×20 mm超广角SS-OCTA扫描的正常受试者168例168眼作为对照组及高度近视患者182例182眼作为高度近视组。比较高度近视组与对照组的全域平均及中央区3D-CVI和CCD,对AL与3D-CVI、CCD分别做相关分析及受试者工作特征曲线分析,并得出3D-CVI及CCD降低时的AL界值。结果高度近视组平均3D-CVI和中央区3D-CVI分别为(31.37±7.85)%和(29.63±9.00)%,均显著低于对照组的(32.86±4.25)%和(35.01±3.96)%,差异均有统计学意义(t=2.241、7.337,均P<0.05)。高度近视组平均CCD为(45.59±3.63)%,显著低于对照组的(46.47±1.36)%,差异有统计学意义(t=3.038,P=0.003)。相关分析结果提示高度近视组中平均3D-CVI、平均CCD均与AL呈负相关(r=-0.547,-0.657,均P<0.001)。进一步对AL和3D-CVI、CCD分别进行受试者工作特征曲线分析,结果提示平均3D-CVI降低的AL界值为28.93 mm,曲线下面积为0.883(P<0.001,灵敏度为0.690,特异度为0.944);平均CCD降低的AL界值为28.26 mm,曲线下面积为0.884(P<0.001,灵敏度为0.793,特异度为0.832)。结论高度近视患者3D-CVI和CCD均降低,随着AL增长,CCD早于3D-CVI发生改变。 展开更多
关键词 高度近视 脉络膜 扫频源光学相干断层扫描血管成像 脉络膜血管指数 脉络膜毛细血管
下载PDF
广域SS-OCTA下早期糖尿病性视网膜病黄斑区的改变
17
作者 蔡亚珍 方严 +2 位作者 崔腾 徐玥 谢驰 《安徽理工大学学报(自然科学版)》 CAS 2024年第4期89-98,共10页
目的基于广域扫频光学相干断层扫描血管成像(SS-OCTA)观察早期糖尿病性视网膜病变(DR)黄斑视网膜微循环的改变及神经节细胞内丛状层(GC-IPL)结构的变化及其相关性。方法于2023年07月至2023年08月在安徽理工大学第一附属医院眼科共招募10... 目的基于广域扫频光学相干断层扫描血管成像(SS-OCTA)观察早期糖尿病性视网膜病变(DR)黄斑视网膜微循环的改变及神经节细胞内丛状层(GC-IPL)结构的变化及其相关性。方法于2023年07月至2023年08月在安徽理工大学第一附属医院眼科共招募105例105眼DR患者,分为无DR组(NDR)53眼和轻至中度非增殖性DR组(NPDR)52眼两组,53例健康受试者作为对照组。采用SS-OCTA以黄斑为中心的12mm×12mm扫描成像并自动定量测算黄斑不同分区的浅层血管复合体(SVC)、深层血管复合体(DVC)的血管密度(VD)、灌注面积(PA),SVC的小血管密度(SVD)以及神经节细胞内从状层(GC-IPL)厚度,并进行相关性分析。结果与对照组相比,NDR组DVC中只有鼻侧象限PA差异有统计学意义(P=0.035);NPDR组除了SVC中VD的上、颞侧象限、PA的上象限、DVC中VD的鼻侧象限差异没有统计学意义(P=0.443、P=0.302、P=0.644、P=0.129),其余均有统计学意义(P<0.05)。与NDR组相比,NPDR组的SVC、DVC中平均VD、总PA以及各象限的和SVC中SVD平均以及各象限的差异均有统计学意义(P<0.05)。与对照组、NDR组相比,NPDR组鼻侧象限GC-IPL的差异均有统计学意义(P=0.020、P=0.003);与对照组相比,NDR组GC-IPL中的差异以及各象限无统计学意义(P=1.000)。在Spearman相关分析中,鼻侧象限GC-IPL与SVC中平均VD、总PA、SVD呈正相关性(r=0.438,P<0.001;r=0.417,P<0.001;r=0.439,P<0.001),中等相关;与DVC中平均VD、总PA呈正相关性(r=0.247,P=0.002;r=0.360,P<0.001),弱相关。结论随着DR进展,广域SS-OCTA可观察到视网膜微循环先代偿性增加后下降。浅层小血管的密度可作为临床前糖尿病视网膜病变早期客观检测影像学标志。早期DR视网膜微循环的改变和视网膜神经改变存在相关性。 展开更多
关键词 糖尿病性视网膜病变 广域扫频光学相干断层扫描血管成像 血管密度 血管复合体 神经节细胞内丛状层
下载PDF
高速扫频源光学相干断层血流成像不同扫描宽度对糖尿病视网膜病变病灶检测率的影响
18
作者 韦丁杨 陈丽 +5 位作者 毛明珠 黎梦宇 刘逸 王祎娅 郭楚云 李杰 《实用医院临床杂志》 2024年第6期124-128,共5页
目的探讨高速扫频源光学相干断层扫描血流成像(SS-OCTA)不同扫描宽度对糖尿病视网膜病变(DR)病灶检测率的影响。方法纳入2021年10月至2023年10月于四川省人民医院眼科就诊的糖尿病(DM)患者126例213眼,接受包括24 mm×20 mm高速广域S... 目的探讨高速扫频源光学相干断层扫描血流成像(SS-OCTA)不同扫描宽度对糖尿病视网膜病变(DR)病灶检测率的影响。方法纳入2021年10月至2023年10月于四川省人民医院眼科就诊的糖尿病(DM)患者126例213眼,接受包括24 mm×20 mm高速广域SS-OCTA扫描方案在内的全面眼科检查。从24 mm×20 mm的OCTA图像中提取一个中心区域记为“12 mm×12 mm中心区”,其余区域记为“12~24 mm环区”。记录并比较使用不同扫描区域的DR病灶检测率。结果共纳入126例参与者的213只眼(54只眼糖尿病无DR,53只眼轻度至中度非增殖性糖尿病视网膜病变(NPDR),54只眼重度NPDR,52只眼增殖性糖尿病视网膜病变(PDR))。24 mm×20 mm OCTA图像无灌注区(NP)检测率显著高于12 mm×12 mm中心区(P<0.05);12~24 mm环区的缺血指数(ISI)中位数明显高于12 mm×12 mm中心区(P<0.05);7眼视网膜新生血管(NV),10眼视网膜内微血管异常(IRMA)病变仅存在于12~24 mm环区域。结论高速广域SS-OCTA单次扫描可捕获24 mm×20 mm视网膜血管图像,更宽的扫描范围可以提高视网膜缺血程度检测的准确性和NV、IRMA的检测率。 展开更多
关键词 糖尿病视网膜病变 微动脉瘤 视网膜内微血管异常 视网膜新生血管 扫频源光学相干断层扫描血流成像术 毛细血管无灌注区
下载PDF
不同年龄段中心性浆液性脉络膜视网膜病变患者患眼与对侧眼的影像学特征
19
作者 肖蓓 宋艳萍 +2 位作者 叶娅 黄珍 闫明 《国际眼科杂志》 CAS 2024年第6期937-942,共6页
目的:观察不同年龄段中心性浆液性脉络膜视网膜病变(CSC)患者患眼及其无症状对侧眼的影像学特征。方法:回顾性研究。选取2023-04/09在我院眼科确诊的CSC患者76例88眼及单眼CSC患者无症状对侧眼35例35眼纳入研究。根据年龄分为中青年组(&... 目的:观察不同年龄段中心性浆液性脉络膜视网膜病变(CSC)患者患眼及其无症状对侧眼的影像学特征。方法:回顾性研究。选取2023-04/09在我院眼科确诊的CSC患者76例88眼及单眼CSC患者无症状对侧眼35例35眼纳入研究。根据年龄分为中青年组(<40岁)、中年组(40-50岁)和中老年组(>50岁),观察不同年龄段CSC患者患眼及其无症状对侧眼的影像学特征。结果:中青年组患者患眼中心凹下脉络膜厚度(SFCT)(487.30±83.33μm)明显大于中年组(414.17±96.02μm,P<0.05)和中老年组(409.4±107.42μm,P<0.05)。中老年组患者患眼脉络膜新生血管(CNV)发生率明显高于中年组(P<0.0167)。中青年组患者对侧眼SFCT(511.29±40.89μm)明显大于中老年组(364.76±82.26μm,P<0.05)。纳入患者患眼涡静脉吻合率高于90%,且对侧眼均存在涡静脉吻合或扩张。结论:不同年龄段CSC患者患眼及其无症状对侧眼影像学表现存在差异,SFCT普遍增厚,且随着年龄增长逐渐变薄,中老年患者患眼CNV发生率最高,同时,CSC患者患眼及其无症状对侧眼普遍存在涡静脉吻合及扩张。 展开更多
关键词 中心性浆液性脉络膜视网膜病变 年龄 脉络膜厚度 涡静脉 超广角扫频光学相干断层扫描 对侧眼
下载PDF
厚脉络膜新生血管病变与中心性浆液性脉络膜视网膜病变患者对侧眼脉络膜参数比较研究
20
作者 肖蓓 宋艳萍 +2 位作者 闫明 叶娅 黄珍 《眼科新进展》 CAS 北大核心 2024年第5期376-381,共6页
目的应用超广角扫频源光学相干断层扫描血管成像(UWF SS-OCTA)比较厚脉络膜新生血管病变(PNV)和中心性浆液性脉络膜视网膜病变(CSC)患者无症状对侧眼的脉络膜参数及形态学变化。方法前瞻性横断面观察研究,纳入2023年4月至2023年9月我院... 目的应用超广角扫频源光学相干断层扫描血管成像(UWF SS-OCTA)比较厚脉络膜新生血管病变(PNV)和中心性浆液性脉络膜视网膜病变(CSC)患者无症状对侧眼的脉络膜参数及形态学变化。方法前瞻性横断面观察研究,纳入2023年4月至2023年9月我院眼科23例CSC患者无症状对侧眼23眼和19例PNV患者无症状对侧眼19眼,以及年龄与性别匹配的22例健康人22眼作为研究对象,分别设为CSC对侧眼组、PNV对侧眼组及健康眼组。三组受试者年龄、男性比例及最佳矫正视力比较,差异均无统计学意义(均为P>0.05),具有可比性。所有研究对象均行UWF SS-OCTA成像检查及比较,记录颞上、上方、鼻上、颞侧、中心凹、鼻侧、颞下、下方、鼻下共9个分区的脉络膜厚度(CT)、脉络膜中大血管层血管密度(血流像素面积与目标区域总面积的比值)、脉络膜血管指数(CVI)(脉络膜血管管腔体积与脉络膜血管及基质总体积的比值)。同时检查并比较各组患者黄斑中心凹下视网膜厚度、黄斑中心凹下脉络膜厚度(SFCT)及涡静脉不对称扩张及吻合情况。结果三组人员SFCT比较,差异有统计学意义(P<0.01)。三组受试者涡静脉不对称扩张或吻合眼数比例比较,差异有统计学意义(P<0.001)。CSC对侧眼组鼻上及鼻侧分区CVI均大于PNV对侧眼组,差异均有统计学意义(均为P<0.05);CSC对侧眼组鼻上、颞侧、中心凹、下方、鼻下分区CVI及平均CVI均大于健康眼组,差异均有统计学意义(均为P<0.05);PNV对侧眼组颞侧、中心凹及下方分区CVI均大于健康眼组,差异均有统计学意义(均为P<0.05)。CSC对侧眼组在颞上、上方、鼻上、中心凹、颞下、平均脉络膜中大血管层血管密度均小于健康眼组,差异均有统计学意义(均为P<0.05);PNV对侧眼组各分区脉络膜中大血管层血管密度均小于健康眼组,差异均有统计学意义(均为P<0.001)。CSC对侧眼组颞上及鼻上分区CT均大于PNV对侧眼组,差异均有统计学意义(均为P<0.05);CSC对侧眼组颞上、上方、鼻上、颞侧、中心凹、下方及鼻下分区CT均大于健康眼组,差异均有统计学意义(均为P<0.05);PNV对侧眼组上方、颞侧、中心凹及下方分区CT均大于健康眼组,差异均有统计学意义(均为P<0.05)。结论本研究从对侧眼角度侧面提供了CSC和PNV可能不是同一疾病不同阶段的验证。CSC与PNV并非单眼疾病,而是单眼表现的双眼脉络膜疾病。 展开更多
关键词 中心性浆液性脉络膜视网膜病变 脉络膜血管指数 超广角扫频源光学相干断层扫描血管成像 涡静脉
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部