A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosa...A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367 × 10(?4) to 2.789 × 10(?2) mol L(?1), the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4–106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples.展开更多
A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol coul...A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol could be transferred into a nitroso-compound by reacting with NaNO2. The titration end-point was obtained by the formation of a sharp cut in the oscillopolarographic with infinitesimal NaNO2 on double platinum electrodes. The results showed that phenol had an excellent linear relationship over the range of 4.82×10^-6 -9.65×10^-3 mol/L, the RSD of the proposed method was lower than 1.5%, and the spiked recoveries of three real water samples were in the range of 95.6%-106.9%.展开更多
文摘A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367 × 10(?4) to 2.789 × 10(?2) mol L(?1), the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4–106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples.
基金Project supported by the Creative Talented Person's Fund of Henan Province (High Teaching [2005]-126)the Natural Science Foundation of Henan Province (No. 0511053000)+1 种基金the Youth Science Foundation of Henan Normal University (No. 2004005)the Henan Key Laboratory for Environmental Pollution Control.
文摘A rapid, simple and sensitive method was demonstrated for the determination of phenolic compounds in water samples by alternating-current oscillopolarographic titration. With the presence of sulfuric acid, phenol could be transferred into a nitroso-compound by reacting with NaNO2. The titration end-point was obtained by the formation of a sharp cut in the oscillopolarographic with infinitesimal NaNO2 on double platinum electrodes. The results showed that phenol had an excellent linear relationship over the range of 4.82×10^-6 -9.65×10^-3 mol/L, the RSD of the proposed method was lower than 1.5%, and the spiked recoveries of three real water samples were in the range of 95.6%-106.9%.