期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Study on Over-Voltage of 220 kV Transformer's Neutrals and Protection Strategy
1
作者 H.P. Yu S.M. Chen +2 位作者 P.C. Yang H. Yin G.L. Wu 《Journal of Energy and Power Engineering》 2011年第11期1102-1108,共7页
In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Current... In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Currently the value of over-voltage on transformer neutral point and the corresponding protection strategy is based on theoretical formula. This article uses the PSCAD/EMTDC software to calculate the over-voltage on the neutral point of 4 ungrounded power transformers in Chongqing 220 kV power grid. The result shows that the power frequency transient over-voltage on the neutrals may reach 178 kV. If the single-phase grounding fault occurs in ungrounded power system, the power frequency over-voltage on the neutrals will be more serious and rise to 138.6 kV. Non-full phase operation may cause serious ferro-resonance over-voltage on the neutrals of no-load transformer, which may last for seconds and may rise to 723.7 kV, causing serious threat to the transformer neutrals and line-side equipment. The article also studies the gap parameter which should be taken on the neutrals of 220 kV transformers at the end. 展开更多
关键词 Neutral point power transformer ARRESTER GAP power frequency over-voltage lightning over-voltage.
下载PDF
Simulation Research of Transient Over-voltage on High-voltage Shunt Capacitor Banks
2
作者 HU Quan-wei ZHOU Xing-xing +3 位作者 SI Wen-rong ZHANG Yang LI Jun-hao LI Yan-ming 《高压电器》 CAS CSCD 北大核心 2011年第9期37-43,共7页
With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor b... With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor banks will bear large numbers of over-voltage inevitably.If the over-voltage exceeds certain amplitude,the capacitor will be damaged.This paper aims at the capacitor banks in the 35 kV side of Shanghai Xu-xing 500 kV substation,and applies ATP-EMTP to simulate the over-voltages generated by operating the switches under different angles of the source.Finally,according to the results of simulation and theoretical analysis,a best choice(i.e.angles of the source) to switch on capacitor banks is proposed.In this case the over-voltage on the capacitor will be limited to lowest. 展开更多
关键词 capacitor banks operating over-voltage EMTP SIMULATION
下载PDF
The Study on New Solid-State Breaker and Its Over-voltage Suppression Technique
3
作者 Longji Zhu Yan Zheng 《Energy and Power Engineering》 2013年第4期1249-1252,共4页
A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, t... A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, to the IGCT’s over-voltage sensitivity problem, a new technique of reducing the over-voltage is introduced, which releases the elect romantics energy of faulty line by a capacitive current branch to reduce the amplitude of over-voltage. Secondly, the principle of over-voltage suppression with current release branch is analyzed, and the overall control scheme of solid- state breaker is put forward. Finally, the simulation results also demonstrate its obvious effectiveness in over-voltage suppression after adding a current release branch into the SSB. 展开更多
关键词 SOLID-STATE BREAKER IGCT over-voltage SUPPRESSION Current RELEASE Circuit
下载PDF
AN APPLICATION OF BIFURCATION OF PERIODIC SOLUTIONS TO FERRORESONANCE OVER-VOLTAGE IN POWER SYSTEMS 被引量:2
4
作者 赖定文 王政贤 《Chinese Science Bulletin》 SCIE EI CAS 1991年第19期1601-1605,共5页
Ferroresonance over-voltage is a destructive factor in power systems and keeps on causing accidents. So far no correct approaches have been found in the theoretical analysis of this complex physical process. In order ... Ferroresonance over-voltage is a destructive factor in power systems and keeps on causing accidents. So far no correct approaches have been found in the theoretical analysis of this complex physical process. In order to avoid difficulties, people usually explain the mechanism of ferroresonance over-voltage with the help of the knowledge about resonance in nonlinear oscillating systems with single degree of freedom. From this point of view, some measures of removing ferroresonance over-voltage have been proposed. However, power systems are not definitely the systems with single degree of freedom, the aforementioned explana- 展开更多
关键词 BIFURCATION of periodic solution integral MANIFOLD FERRORESONANCE over-voltage.
原文传递
The Mechanism of Eliminating Harmonic Resonance with Controllers and Application to the Power Systems
5
作者 吴琼 计国君 +1 位作者 宋文忠 戴先中 《Journal of Southeast University(English Edition)》 EI CAS 2002年第2期164-172,共9页
The phenomenon of anti-symmetrical bifurcation of periodic solutionsoccurring near an integral manifold is the intrinsic cause resulting in harmonic resonanceover-voltage in power systems. Due to this discovery, the p... The phenomenon of anti-symmetrical bifurcation of periodic solutionsoccurring near an integral manifold is the intrinsic cause resulting in harmonic resonanceover-voltage in power systems. Due to this discovery, the principle of eliminating resonance byusing anti-bifurcation technique is presented, which makes that the theoretical bases of verymeasure to eliminate resonance are unified firstly from a point of view of basic theory. Ourdiscussion models depend on a class of nonlinear control model. Using the direct Lyapunov method, acomplete theoretical proof is given in accordance with the measure of eliminating resonance byconnecting nonlinear resistor in series to the neutral point of P. T., and the feedback control lawbeing applied. It comprises the action of parameters of resistor to eliminate resonance and theactual process of eliminating resonance, i.e., to go against bifurcation process which forces thebig harmonic solutions to retreat to the integral manifold gradually and disappear eventually, whichby using the nonlinear controllers. This makes it sure that the intrinsic cause of resonance iseliminated thoroughly. The obtained theory results and computing results are better than thepresented results. 展开更多
关键词 eliminate resonance feedback control law over-voltage BIFURCATION MANIFOLD
下载PDF
Large-Scale Renewable Energy Transmission by HVDC: Challenges and Proposals 被引量:11
6
作者 Weisheng Wang Guanghui Li Jianbo Guo 《Engineering》 SCIE EI CAS 2022年第12期252-267,共16页
Renewable energy transmission by high-voltage direct current(HVDC)has attracted increasing attention for the development and utilization of large-scale renewable energy under the Carbon Peak and Carbon Neutrality Stra... Renewable energy transmission by high-voltage direct current(HVDC)has attracted increasing attention for the development and utilization of large-scale renewable energy under the Carbon Peak and Carbon Neutrality Strategy in China.High-penetration power electronic systems(HPPESs)have gradually formed at the sending end of HVDC transmission.The operation of such systems has undergone profound changes compared with traditional power systems dominated by synchronous generators.New stability issues,such as broadband oscillation and transient over-voltage,have emerged,causing tripping accidents in large-scale renewable energy plants.The analysis methods and design principles of traditional power systems are no longer suitable for HPPESs.In this paper,the mechanisms of broadband oscillation and transient over-voltage are revealed,and analytical methods are proposed for HPPESs,including small-signal impedance analysis and electromagnetic transient simulation.Validation of the theoretical research has been accomplished through its application in several practical projects in north,northwest,and northeast region of China.Finally,suggestions for the construction and operation of the future renewable-energy-dominated power system are put forward. 展开更多
关键词 Broadband oscillation Future power system HVDC transmission Renewable energy generation Transient over-voltage
下载PDF
Repeated Strike Process During Disconnector Operation in Ultra-High Voltage Gas-Insulated Switchgear 被引量:1
7
作者 关永刚 蔡元纪 +4 位作者 陈维江 刘卫东 李志兵 岳功昌 张俊民 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期247-253,共7页
Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investiga... Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO. 展开更多
关键词 disconnector (DS) repeated strike process DISCHARGE statistical breakdowncharacteristics ultra-high voltage (UHV) very fast transient over-voltage (VFTO)
下载PDF
Research on Reverse Recovery Transient of Parallel Thyristors for Fusion Power Supply
8
作者 查烽炜 宋执权 +2 位作者 傅鹏 董琳 王敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第7期716-720,共5页
In nuclear fusion power supply systems, the thyristors often need to be connected in parallel for sustaining large current. However, research on the reverse recovery transient of parallel thyristors has not been repor... In nuclear fusion power supply systems, the thyristors often need to be connected in parallel for sustaining large current. However, research on the reverse recovery transient of parallel thyristors has not been reported yet. When several thyristors are connected in parallel,they cannot turn-off at the same moment, and thus the turn-off model based on a single thyristor is no longer suitable. In this paper, an analysis is presented for the reverse recovery transient of parallel thyristors. Parallel thyristors can be assumed as one virtual thyristor so that the reverse recovery current can be modeled by an exponential function. Through equivalent transformation of the rectifier circuit, the commutating over-voltage can be calculated based on Kirchhoff’s equation. The reverse recovery current and commutation over-voltage waveforms are measured on an experiment platform for a high power rectifier supply. From the measurement results, it is concluded that the modeling method is acceptable. 展开更多
关键词 parallel thyristors reverse recovery transient commutating over-voltage high power rectifier
下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
9
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
A modular multilevel power flow controller for meshed HVDC grids 被引量:5
10
作者 XU Feng XU Zheng 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第9期1773-1784,共12页
Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of me... Based on the comparison of existing power flow controllers(PFC)in meshed HVDC grids,the full-bridge modular multilevel converter based PFC(MMPFC)is proposed.At first,the general branch current calculation method of meshed HVDC grids with the PFC is presented,and then,the issue of over-voltage on the thyristor based PFC is described and analyzed.Through the analysis of different operating modes of the full-bridge sub-module,the mechanism of over-voltage ride through of the MMPFC is indicated.The control strategy of the MMPFC,which is used to control branch current and keep capacitor voltage balancing,is elaborated.Finally,the performance on current regulation,bidirectional operation and over-voltage ride through is simulated and verified in a built model with PSCAD/EMTDC. 展开更多
关键词 meshed HVDC grids multi-terminal HVDC modular multilevel power flow controller (MMPFC) bidirectional operation over-voltage ride through full-bridge sub-module
原文传递
Protection Distance of Surge Protective Devices in Low Voltage Distribution Systems 被引量:1
11
作者 张栋 傅正财 +1 位作者 赵刚 孙伟 《Journal of Shanghai Jiaotong university(Science)》 EI 2008年第4期477-481,共5页
Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage... Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method. 展开更多
关键词 over-voltage protection surge protective devices (SPDs) effective protection distance lumped-parameter circuit
原文传递
A novel algorithm for frequency dependent modeling of ferrite ring and its optimum design to study VFTO behaviors within GIS
12
作者 Mehrdad MAJIDI Hamid JAVADI Moein MANBACHI 《Frontiers in Energy》 SCIE CSCD 2014年第1期90-100,共11页
One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order ... One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemen- ted on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios. 展开更多
关键词 comsol multiphysics EMTP-RV ferrite ring gas insulated substations (GIS) transient over-voltage insulation coordination
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部