Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this...Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.展开更多
The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type r...The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type relay is proposed. The setting of the trip time for this relay is performed by determining the shortest trip time and the longest trip time, respectively. The results of analysis show that with the new time function, the inverse-time overcurrent relay is easy to coordinate with other relays and has a comparatively shorter trip time, and that the fault happens in the protective zone.展开更多
The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integra...The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integrated protection equipment, OC protection setting table must be converted to be a microcomputer algorithm. This paper first intro-duced a method of the fitting OC protection setting table to be OC relay inverse time characteristics equations using MATLAB least square fitting. On the basis of analyzing these fitting equations, a notion, “integral limit rate” was put forward initially and a OC in-verse time digital algorithm was developed. MATLAB simulation results and a digital signal processor (DSP) based digital integrated protection equipment running test indicate that this algorithm has less calculation amount, less taking up memory, high control accuracy, implements the no-grade setting of OC delay values, suits for all kinds of low-middle mi-crocomputer system implementation.展开更多
This paper presents a study on protection coordination of over current relays (OCRs) in a distributed system by considering its different operating modes. Two different case studies which are considered in present wor...This paper presents a study on protection coordination of over current relays (OCRs) in a distributed system by considering its different operating modes. Two different case studies which are considered in present work for protection coordination include: (i) DG interfaced distribution system in grid connected mode and (ii) DG interfaced distribution system in islanded mode of operation. The proposed approach is tested on the Canadian urban benchmark distribution system consisting of 9 buses. On the occurrence of fault, level of fault current changes which in turn changes the operating time of various OCRs. Therefore, it is important to calculate and suggest method of the relay setting in order to minimize the operating time of relays and also to avoid its mal-operation. In this paper, the protection scheme is optimally designed by taking into account the above mentioned conditions. The operating time of relays can be decreased and, at the same time, coordination can be maintained by considering the optimum values of time dial setting (TDS). Genetic Algorithm (GA) has been used for determining the optimum values of TDS and hence operating time.展开更多
继电保护装置是电力系统的核心部分,其定值整定直接关系到继电保护的动作。只有充分发挥继电保护装置的作用,在电网发生故障时能快速、正确地做出反应,才能保证整个电网的安全运行。在过电流继电器(Over current relay,OCR)的保护整定中...继电保护装置是电力系统的核心部分,其定值整定直接关系到继电保护的动作。只有充分发挥继电保护装置的作用,在电网发生故障时能快速、正确地做出反应,才能保证整个电网的安全运行。在过电流继电器(Over current relay,OCR)的保护整定中,整定值通常通过试错法获得,往往导致整定值不够准确。因此,提出一种基于数值计算算法的新程序,通过在实际电气系统中反时限过电流保护时间常数整定值(Time dial setting,TDS)和时间-电流特性(Time-current characteristic,TCC)曲线来整定反时限过电流继电器,简单而准确地获取OCR设定值。结果表明,数值计算算法程序计算结果与实际电力系统中的值非常接近,还可以优化TDS和TCC曲线。展开更多
文摘Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains.
基金TheNationalNaturalScienceFoundationofChina (No .6 9774 0 2 4 )
文摘The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type relay is proposed. The setting of the trip time for this relay is performed by determining the shortest trip time and the longest trip time, respectively. The results of analysis show that with the new time function, the inverse-time overcurrent relay is easy to coordinate with other relays and has a comparatively shorter trip time, and that the fault happens in the protective zone.
文摘The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integrated protection equipment, OC protection setting table must be converted to be a microcomputer algorithm. This paper first intro-duced a method of the fitting OC protection setting table to be OC relay inverse time characteristics equations using MATLAB least square fitting. On the basis of analyzing these fitting equations, a notion, “integral limit rate” was put forward initially and a OC in-verse time digital algorithm was developed. MATLAB simulation results and a digital signal processor (DSP) based digital integrated protection equipment running test indicate that this algorithm has less calculation amount, less taking up memory, high control accuracy, implements the no-grade setting of OC delay values, suits for all kinds of low-middle mi-crocomputer system implementation.
文摘This paper presents a study on protection coordination of over current relays (OCRs) in a distributed system by considering its different operating modes. Two different case studies which are considered in present work for protection coordination include: (i) DG interfaced distribution system in grid connected mode and (ii) DG interfaced distribution system in islanded mode of operation. The proposed approach is tested on the Canadian urban benchmark distribution system consisting of 9 buses. On the occurrence of fault, level of fault current changes which in turn changes the operating time of various OCRs. Therefore, it is important to calculate and suggest method of the relay setting in order to minimize the operating time of relays and also to avoid its mal-operation. In this paper, the protection scheme is optimally designed by taking into account the above mentioned conditions. The operating time of relays can be decreased and, at the same time, coordination can be maintained by considering the optimum values of time dial setting (TDS). Genetic Algorithm (GA) has been used for determining the optimum values of TDS and hence operating time.