期刊文献+
共找到7,222篇文章
< 1 2 250 >
每页显示 20 50 100
A Physical Security Technology Based upon Doubly Multiple Parameters Weighted Fractional Fourier Transform
1
作者 Li Yong Sun Teng +2 位作者 Sha Xuejun Song Zhiqun Wang Bin 《China Communications》 SCIE CSCD 2024年第10期200-209,共10页
Enhancing the security of the wireless communication is necessary to guarantee the reliable of the data transmission, due to the broadcast nature of wireless channels. In this paper, we provide a novel technology refe... Enhancing the security of the wireless communication is necessary to guarantee the reliable of the data transmission, due to the broadcast nature of wireless channels. In this paper, we provide a novel technology referred to as doubly multiple parameters weighted fractional Fourier transform(DMWFRFT), which can strengthen the physical layer security of wireless communication. This paper introduces the concept of DM-WFRFT based on multiple parameters WFRFT(MP-WFRFT), and then presents its four properties. Based on these properties, the parameters decryption probability is analyzed in terms of the number of parameters. The number of parameters for DM-WFRFT is more than that of the MP-WFRFT,which indicates that the proposed scheme can further strengthen the the physical layer security. Lastly, some numerical simulations are carried out to illustrate that the efficiency of proposed DM-WFRFT is related to preventing eavesdropping, and the effect of parameters variety on the system performance is associated with the bit error ratio(BER). 展开更多
关键词 doubly multiple parameters weighted fractional Fourier transform(DM-WFRFT) physical layer security transform parameters variety
下载PDF
Interaction between systemic iron parameters and left ventricular structure and function in the preserved ejection fraction population:a two-sample bidirectional Mendelian randomization study 被引量:1
2
作者 Xiong-Bin MA Yong-Ming LIU +1 位作者 Yan-Lin LV Lin QIAN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第1期64-80,共17页
BACKGROUND Left ventricular(LV)remodeling and diastolic function in people with heart failure(HF)are correlated with iron status;however,the causality is uncertain.This Mendelian randomization(MR)study investigated th... BACKGROUND Left ventricular(LV)remodeling and diastolic function in people with heart failure(HF)are correlated with iron status;however,the causality is uncertain.This Mendelian randomization(MR)study investigated the bidirectional causal relationship between systemic iron parameters and LV structure and function in a preserved ejection fraction population.METHODS Transferrin saturation(TSAT),total iron binding capacity(TIBC),and serum iron and ferritin levels were extracted as instrumental variables for iron parameters from meta-analyses of public genome-wide association studies.Individuals without myocardial infarction history,HF,or LV ejection fraction(LVEF)<50%(n=16,923)in the UK Biobank Cardiovascular Magnetic Resonance Imaging Study constituted the outcome dataset.The dataset included LV end-diastolic volume,LV endsystolic volume,LV mass(LVM),and LVM-to-end-diastolic volume ratio(LVMVR).We used a two-sample bidirectional MR study with inverse variance weighting(IVW)as the primary analysis method and estimation methods using different algorithms to improve the robustness of the results.RESULTS In the IVW analysis,one standard deviation(SD)increased in TSAT significantly correlated with decreased LVMVR(β=-0.1365;95%confidence interval[CI]:-0.2092 to-0.0638;P=0.0002)after Bonferroni adjustment.Conversely,no significant relationships were observed between other iron and LV parameters.After Bonferroni correction,reverse MR analysis showed that one SD increase in LVEF significantly correlated with decreased TSAT(β=-0.0699;95%CI:-0.1087 to-0.0311;P=0.0004).No heterogeneity or pleiotropic effects evidence was observed in the analysis.CONCLUSIONS We demonstrated a causal relationship between TSAT and LV remodeling and function in a preserved ejection fraction population. 展开更多
关键词 FRACTION function parameters
下载PDF
Determination of uncertainties of geomechanical parameters of metamorphic rocks using petrographic analyses
3
作者 Behzad Dastjerdy Ali Saeidi Shahriyar Heidarzadeh 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第2期345-364,共20页
Geomechanical parameters of intact metamorphic rocks determined from laboratory testing remain highly uncertain because of the great intrinsic variability associated with the degrees of metamorphism.The aim of this pa... Geomechanical parameters of intact metamorphic rocks determined from laboratory testing remain highly uncertain because of the great intrinsic variability associated with the degrees of metamorphism.The aim of this paper is to develop a proper methodology to analyze the uncertainties of geomechanical characteristics by focusing on three domains,i.e.data treatment process,schistosity angle,and mineralogy.First,the variabilities of the geomechanical laboratory data of Westwood Mine(Quebec,Canada)were examined statistically by applying different data treatment techniques,through which the most suitable outlier methods were selected for each parameter using multiple decision-making criteria and engineering judgment.Results indicated that some methods exhibited better performance in identifying the possible outliers,although several others were unsuccessful because of their limitation in large sample size.The well-known boxplot method might not be the best outlier method for most geomechanical parameters because its calculated confidence range was not acceptable according to engineering judgment.However,several approaches,including adjusted boxplot,2MADe,and 2SD,worked very well in the detection of true outliers.Also,the statistical tests indicate that the best-fitting probability distribution function for geomechanical intact parameters might not be the normal distribution,unlike what is assumed in most geomechanical studies.Moreover,the negative effects of schistosity angle on the uniaxial compressive strength(UCS)variabilities were reduced by excluding the samples within a specific angle range where the UCS data present the highest variation.Finally,a petrographic analysis was conducted to assess the associated uncertainties such that a logical link was found between the dispersion and the variabilities of hard and soft minerals. 展开更多
关键词 Intact rock parameters Natural variabilities Outlier detection methods UNCERTAINTIES Westwood mine MINERALOGY
下载PDF
Spatiotemporal variations of parameters of internal solitary waves in the northern South China Sea
4
作者 Yu’ang LIU Yifei JIANG +3 位作者 Xiaojiang ZHANG Zhiyuan WANG Yu CAO Huizan WANG 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第2期421-438,共18页
The dynamic parameters for internal solitary waves(ISWs)derived from the extended Korteweg-de Vries(eKdV)equation play an important role in the understanding and prediction of ISWs.The spatiotemporal variations of the... The dynamic parameters for internal solitary waves(ISWs)derived from the extended Korteweg-de Vries(eKdV)equation play an important role in the understanding and prediction of ISWs.The spatiotemporal variations of the dynamic parameters of the ISWs in the northern South China Sea(SCS)were studied based on the reanalysis of long-term temperature and salinity datasets.The results for spectrum analysis show that there are definite geographical differences for the periodic variation of the parameters:in shallow water,all parameters vary with a wave period of one year,while in deep water wave components of the parameters at other frequencies exist.Using wavelet analysis,the wavelet power spectral densities in deep water exhibited an inter-annual variation pattern.For example,the wave component of the dispersion coefficient with a wave period of about half a year reached its power peak once every two years.Based on previous work,this inter-annual variation pattern was deduced to be caused by dynamic processes.In further work on the regulatory mechanisms,empirical orthogonal function(EOF)decomposition was performed.It was found that the modes of the dispersion coefficient have different geographical distributions,explaining the reason why the wave components in different frequencies appeared in different locations.The numerical simulation results confirm that the variations in the parameters of the ISWs derived from the eKdV equation could affect the waveforms significantly because of changes in the polarity of the ISWs.Therefore,the periodic variations of the dynamic parameters are related to the geographical location because of dynamic processes operating. 展开更多
关键词 internal solitary waves(ISWs) dynamic parameters eKdV equation spatiotemporal variation polarity empirical orthogonal function(EOF)decomposition
下载PDF
The effects of deformation parameters and cooling rates on the aging behavior of AZ80+0.4%Ce
5
作者 Yongbiao Yang Jinxuan Guo +6 位作者 Cuiying Wang Ting Yan Zhang Wenxuan Jiang Zhimin Zhang Qiang Wang Guojun Li Jun Wang 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第2期639-658,共20页
The extruded AZ80+0.4%Ce magnesium alloy was twisted in the temperature range of 300-380℃by using a Gleeble 3500 thermal simulation test machine with a torsion unit.The deformed cylindrical specimens were cooled at a... The extruded AZ80+0.4%Ce magnesium alloy was twisted in the temperature range of 300-380℃by using a Gleeble 3500 thermal simulation test machine with a torsion unit.The deformed cylindrical specimens were cooled at a cooling rate of 10℃/s or 0.1℃/s,respectively,and aged at 170℃.The microstructure analysis results showed that the grain size decreased with increasing specimen radial position from center(SRPC),and that the strong initial basal texture of the extruded magnesium alloy was weakened.Both continuous and discontinuous dynamic recrystallization mechanisms were involved in contributing to the grain refinement for all specimens investigated.And a novel extension twinning induced dynamic recrystallization mechanism was proposed for specimen deformed at 300℃.For the specimens deformed at 300℃and 340℃followed by a slow cooling rate(0.1℃/s),precipitates of various shapes(β-Mg_(17)Al_(12)),with the dominant precipitates being on the grains boundaries,appeared on the surface section.For specimen deformed at 380℃,lamellar precipitates(LPS)in the interiors of the grains were predominant.After aging,the LPS still dominated for specimens twisted at 380℃;however,the LPS gradually decreased with decreasing deformation temperatures from 380℃to 300℃.Dynamically precipitatedβ,especially those decorating the grain boundaries,changed the competition pictures for the LPS and precipitates of other shapes after aging.Interestingly,LPS dominated the areas for the center section of the specimens after aging regardless of deformation temperatures.Low temperature deformation with high SRPC followed by rapid cooling rate increased the micro hardness of the alloy after aging due to refined grain,reduced precipitates size,decreased lamellar spacing as well as strain hardening. 展开更多
关键词 AZ80+0.4%Ce magnesium alloy Hot torsion Deformation parameters Cooling rate Aging Micro hardness
下载PDF
Analysis and comparison of retinal vascular parameters under different glucose metabolic status based on deep learning
6
作者 Yan Jiang Di Gong +7 位作者 Xiao-Hong Chen Lin Yang Jing-Jing Xu Qi-Jie Wei Bin-Bin Chen Yong-Jiang Cai Wen-Qun Xi Zhe Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1581-1591,共11页
AIM:To develop a deep learning-based model for automatic retinal vascular segmentation,analyzing and comparing parameters under diverse glucose metabolic status(normal,prediabetes,diabetes)and to assess the potential ... AIM:To develop a deep learning-based model for automatic retinal vascular segmentation,analyzing and comparing parameters under diverse glucose metabolic status(normal,prediabetes,diabetes)and to assess the potential of artificial intelligence(AI)in image segmentation and retinal vascular parameters for predicting prediabetes and diabetes.METHODS:Retinal fundus photos from 200 normal individuals,200 prediabetic patients,and 200 diabetic patients(600 eyes in total)were used.The U-Net network served as the foundational architecture for retinal arteryvein segmentation.An automatic segmentation and evaluation system for retinal vascular parameters was trained,encompassing 26 parameters.RESULTS:Significant differences were found in retinal vascular parameters across normal,prediabetes,and diabetes groups,including artery diameter(P=0.008),fractal dimension(P=0.000),vein curvature(P=0.003),C-zone artery branching vessel count(P=0.049),C-zone vein branching vessel count(P=0.041),artery branching angle(P=0.005),vein branching angle(P=0.001),artery angle asymmetry degree(P=0.003),vessel length density(P=0.000),and vessel area density(P=0.000),totaling 10 parameters.CONCLUSION:The deep learning-based model facilitates retinal vascular parameter identification and quantification,revealing significant differences.These parameters exhibit potential as biomarkers for prediabetes and diabetes. 展开更多
关键词 deep learning retinal vascular parameters segmentation model DIABETES PREDIABETES
下载PDF
Effects of gravel on the water absorption characteristics and hydraulic parameters of stony soil
7
作者 MA Yan WANG Youqi +2 位作者 MA Chengfeng YUAN Cheng BAI Yiru 《Journal of Arid Land》 SCIE CSCD 2024年第7期895-909,共15页
The eastern foothills of the Helan Mountains in China are a typical mountainous region of soil and gravel,where gravel could affect the water movement process in the soil.This study focused on the effects of different... The eastern foothills of the Helan Mountains in China are a typical mountainous region of soil and gravel,where gravel could affect the water movement process in the soil.This study focused on the effects of different gravel contents on the water absorption characteristics and hydraulic parameters of stony soil.The stony soil samples were collected from the eastern foothills of the Helan Mountains in April 2023 and used as the experimental materials to conduct a one-dimensional horizontal soil column absorption experiment.Six experimental groups with gravel contents of 0%,10%,20%,30%,40%,and 50%were established to determine the saturated hydraulic conductivity(K_(s)),saturated water content(θ_(s)),initial water content(θ_(i)),and retention water content(θ_(r)),and explore the changes in the wetting front depth and cumulative absorption volume during the absorption experiment.The Philip model was used to fit the soil absorption process and determine the soil water absorption rate.Then the length of the characteristic wetting front depth,shape coefficient,empirical parameter,inverse intake suction and soil water suction were derived from the van Genuchten model.Finally,the hydraulic parameters mentioned above were used to fit the soil water characteristic curves,unsaturated hydraulic conductivity(K_(θ))and specific water capacity(C(h)).The results showed that the wetting front depth and cumulative absorption volume of each treatment gradually decreased with increasing gravel content.Compared with control check treatment with gravel content of 0%,soil water absorption rates in the treatments with gravel contents of 10%,20%,30%,40%,and 50%decreased by 11.47%,17.97%,25.24%,29.83%,and 42.45%,respectively.As the gravel content increased,inverse intake suction gradually increased,and shape coefficient,K_(s),θ_(s),andθ_(r)gradually decreased.For the same soil water content,soil water suction and K_(θ)gradually decreased with increasing gravel content.At the same soil water suction,C(h)decreased with increasing gravel content,and the water use efficiency worsened.Overall,the water holding capacity,hydraulic conductivity,and water use efficiency of stony soil in the eastern foothills of the Helan Mountains decreased with increasing gravel content.This study could provide data support for improving soil water use efficiency in the eastern foothills of the Helan Mountains and other similar rocky mountainous areas. 展开更多
关键词 stony soil gravel content water absorption characteristics hydraulic parameters one-dimensional horizontal soil column absorption experiment van Genuchten model eastern foothills of Helan Mountains
下载PDF
Effect of Types and Orders of Electromagnetic Field Finite Element Meshes on Power Communication Harmonic Parameters Calculation Results of Tubular Hydrogenerators
8
作者 Fan Zhennan Chen Jie +1 位作者 Zhou Zhiting Yang Yong 《China Communications》 SCIE CSCD 2024年第10期288-300,共13页
In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication q... In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication quality.Tubular hydrogenerators are considered the optimal generator for exploiting low-head,high-flow hydro resources,and they have seen increasingly widespread application in China's power systems recent years.However,owing to the compact and constrained internal space of such generators,their internal magnetic-field harmonics are pronounced.Therefore,accurate calculation of their THD and THF is crucial during the analysis and design stages to ensure the quality of power communication.Especially in the electromagnetic field finite element modeling analysis of such generators,the type and order of the finite element meshes may have a significant impact on the THD and THF calculation results,which warrants in-depth research.To address this,this study takes a real 34 MW large tubular hydrogenerator as an example,and establishes its electromagnetic field finite element model under no-load conditions.Two types of meshes,five mesh densities,and two mesh orders are analyzed to reveal the effect of electromagnetic field finite element mesh types and orders on the calculation results of THD and THF for such generators. 展开更多
关键词 calculation results electromagnetic field finite element meshes power communication harmonic parameters tubular hydrogenerator types and orders
下载PDF
Digital measuring the ocular morphological parameters of guinea pig eye in vivo with Python
9
作者 Yue Di Zhong-Bao Qiao +4 位作者 Hai-Yun Ye Xin-Yue Li Wen-Ting Luo Wang-Yi Fang Tong Qiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期239-246,共8页
AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtai... AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtain the horizontal,coronal,and sagittal planes respectively.The corresponding photo pixels-actual length ratio was acquired by a proportional scale.The edge coordinates were identified artificially by ginput function.Circle and conic curve fitting were applied to fit the contour of the eyeball in the sagittal,coronal and horizontal view.The curvature,curvature radius,eccentricity,tilt angle,corneal diameter,and binocular separation angle were calculated according to the geometric principles.Next,the eyeballs were removed,canny edge detection was applied to identify the contour of eyeball in vitro.The results were compared between in vivo and in vitro.RESULTS:Regarding the corneal curvature and curvature radius on the horizontal and sagittal planes,no significant differences were observed among results in vivo,in vitro,and the keratometer.The horizontal and vertical binocular separation angles were 130.6°±6.39°and 129.8°±9.58°respectively.For the corneal curvature radius and eccentricity in vivo,significant differences were observed between horizontal and vertical planes.CONCLUSION:The Graphical interface window of Python makes up the deficiency of edge detection,which requires too much definition in Matlab.There are significant differences between guinea pig and human beings,such as exotropic eye position,oblique oval eyeball,and obvious discrepancy of binoculus.This study helps evaluate objectively the ocular morphological parameters of small experimental animals in emmetropization research. 展开更多
关键词 ocular morphological parameters guinea pig digital measurement PYTHON
下载PDF
An empirical method for joint inversion of wave and wind parameters based on SAR and wave spectrometer data
10
作者 Yong Wan Xiaona Zhang +2 位作者 Shuyan Lang Ennan Ma Yongshou Dai 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2024年第5期133-144,共12页
Synthetic aperture radar(SAR)and wave spectrometers,crucial in microwave remote sensing,play an essential role in monitoring sea surface wind and wave conditions.However,they face inherent limitations in observing sea... Synthetic aperture radar(SAR)and wave spectrometers,crucial in microwave remote sensing,play an essential role in monitoring sea surface wind and wave conditions.However,they face inherent limitations in observing sea surface phenomena.SAR systems,for instance,are hindered by an azimuth cut-off phenomenon in sea surface wind field observation.Wave spectrometers,while unaffected by the azimuth cutoff phenomenon,struggle with low azimuth resolution,impacting the capture of detailed wave and wind field data.This study utilizes SAR and surface wave investigation and monitoring(SWIM)data to initially extract key feature parameters,which are then prioritized using the extreme gradient boosting(XGBoost)algorithm.The research further addresses feature collinearity through a combined analysis of feature importance and correlation,leading to the development of an inversion model for wave and wind parameters based on XGBoost.A comparative analysis of this model with ERA5 reanalysis and buoy data for of significant wave height,mean wave period,wind direction,and wind speed reveals root mean square errors of 0.212 m,0.525 s,27.446°,and 1.092 m/s,compared to 0.314 m,0.888 s,27.698°,and 1.315 m/s from buoy data,respectively.These results demonstrate the model’s effective retrieval of wave and wind parameters.Finally,the model,incorporating altimeter and scatterometer data,is evaluated against SAR/SWIM single and dual payload inversion methods across different wind speeds.This comparison highlights the model’s superior inversion accuracy over other methods. 展开更多
关键词 synthetic aperture radar(SAR) wave spectrometer extreme gradient boosting(XGBoost) joint inversion method wave and wind parameters
下载PDF
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
11
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
下载PDF
Time-varying parameters estimation with adaptive neural network EKF for missile-dual control system
12
作者 YUAN Yuqi ZHOU Di +1 位作者 LI Junlong LOU Chaofei 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第2期451-462,共12页
In this paper, a filtering method is presented to estimate time-varying parameters of a missile dual control system with tail fins and reaction jets as control variables. In this method, the long-short-term memory(LST... In this paper, a filtering method is presented to estimate time-varying parameters of a missile dual control system with tail fins and reaction jets as control variables. In this method, the long-short-term memory(LSTM) neural network is nested into the extended Kalman filter(EKF) to modify the Kalman gain such that the filtering performance is improved in the presence of large model uncertainties. To avoid the unstable network output caused by the abrupt changes of system states,an adaptive correction factor is introduced to correct the network output online. In the process of training the network, a multi-gradient descent learning mode is proposed to better fit the internal state of the system, and a rolling training is used to implement an online prediction logic. Based on the Lyapunov second method, we discuss the stability of the system, the result shows that when the training error of neural network is sufficiently small, the system is asymptotically stable. With its application to the estimation of time-varying parameters of a missile dual control system, the LSTM-EKF shows better filtering performance than the EKF and adaptive EKF(AEKF) when there exist large uncertainties in the system model. 展开更多
关键词 long-short-term memory(LSTM)neural network extended Kalman filter(EKF) rolling training time-varying parameters estimation missile dual control system
下载PDF
A Data-Oriented Method to Optimize Hydraulic Fracturing Parameters of Tight Sandstone Reservoirs
13
作者 Zhengrong Chen Mao Jiang +2 位作者 Chuanzhi Ai Jianshu Wu Xin Xie 《Energy Engineering》 EI 2024年第6期1657-1669,共13页
Based on the actual data collected from the tight sandstone development zone, correlation analysis using theSpearman method was conducted to determine the main factors influencing the gas production rate of tightsands... Based on the actual data collected from the tight sandstone development zone, correlation analysis using theSpearman method was conducted to determine the main factors influencing the gas production rate of tightsandstone fracturing. An integrated model combining geological engineering and numerical simulation of fracturepropagation and production was completed. Based on data analysis, the hydraulic fracture parameters wereoptimized to develop a differentiated fracturing treatment adjustment plan. The results indicate that the influenceof geological and engineering factors in the X1 and X2 development zones in the study area differs significantly.Therefore, it is challenging to adopt a uniform development strategy to achieve rapid production increase. Thedata analysis reveals that the variation in gas production rate is primarily affected by the reservoir thickness andpermeability parameters as geological factors. On the other hand, the amount of treatment fluid and proppantaddition significantly impact the gas production rate as engineering factors. Among these factors, the influence ofgeological factors is more pronounced in block X1. Therefore, the main focus should be on further optimizing thefracturing interval and adjusting the geological development well location. Given the existing well location, thereis limited potential for further optimizing fracture parameters to increase production. For block X2, the fracturingparameters should be optimized. Data screening was conducted to identify outliers in the entire dataset, and adata-driven fracturing parameter optimization method was employed to determine the basic adjustment directionfor reservoir stimulation in the target block. This approach provides insights into the influence of geological,stimulation, and completion parameters on gas production rate. Consequently, the subsequent fracturing parameteroptimization design can significantly reduce the modeling and simulation workload and guide field operations toimprove and optimize hydraulic fracturing efficiency. 展开更多
关键词 Data mechanism driven fracturing parameters gas production CORRELATION tight sandstone gas
下载PDF
Relationship between ultrasound parameters of the umbilical and middle cerebral arteries and intrauterine fetal distress
14
作者 Ji Chen Fei-Xue Liu Rui-Xue Tao 《World Journal of Clinical Cases》 SCIE 2024年第16期2745-2750,共6页
BACKGROUND By comprehensively analyzing the blood flow parameters of the umbilical and middle cerebral arteries,doctors can more accurately identify fetal intrauterine distress,as well as assess its severity,so that t... BACKGROUND By comprehensively analyzing the blood flow parameters of the umbilical and middle cerebral arteries,doctors can more accurately identify fetal intrauterine distress,as well as assess its severity,so that timely interventions can be implemented to safeguard the health and safety of the fetus.AIM To identify the relationship between ultrasound parameters of the umbilical and middle cerebral arteries and intrauterine distress.METHODS Clinical data of pregnant women admitted between January 2021 and January 2023 were collected and divided into the observation and control groups(n=50 each),according to the presence or absence of intrauterine distress.The ultrasound hemodynamic parameters of the uterine artery(UtA),fetal middle cerebral artery(MCA),and umbilical artery(UmA)were compared with neonatal outcomes and occurrence of intrauterine distress in the two groups.RESULTS Comparison of ultrasonic hemodynamic parameters,resistance index(RI),pulsatility index(PI),and systolic maximal blood flow velocity of UmA compared to diastolic blood flow velocity(S/D),revealed higher values of fetal MCA,PI,and S/D of UmA in pregnant women with UtA compared to controls(P<0.05),while there was no difference between the two groups in terms of RI(P<0.05)The incidence of a neonatal Apgar score of 8-10 points was lower in the observation group(66.7%)than in the control group(90.0%),and neonatal weight(2675.5±27.6 g)was lower than in the control group(3117.5±31.2 g).Further,cesarean section rate was higher in the observation group(70.0%)than in the control group(11.7%),and preterm labor rate was higher in the observation group(40.0%)than in the control group(10.0%).The incidence of fetal distress,neonatal growth restriction and neonatal asphyxia were also higher in the observation group(all P<0.05).CONCLUSION Fetal MCA,UmA,and maternal UtA hemodynamic abnormalities all develop in pregnant women with intrauterine distress during late pregnancy,which suggests that clinical attention should be paid to them,and monitoring should be strengthened to provide guidance for clinical intervention. 展开更多
关键词 Late pregnancy Fetal intrauterine distress Ultrasound blood flow parameters Uterine artery Middle cerebral artery Umbilical artery
下载PDF
Effect of process parameters on the morphology of aluminum/copper alloy lap joints by red and blue hybrid laser welding
15
作者 宋曜祥 肖梦智 +4 位作者 黄德才 张瑞华 尹燕 茹恩光 吴怡霖 《China Welding》 CAS 2024年第2期23-30,共8页
In order to overcome the problems of many pores,large deformation and unstable weld quality of traditional laser welded aluminumcopper alloy joints,a red-blue dual-beam laser source and a swinging laser were introduce... In order to overcome the problems of many pores,large deformation and unstable weld quality of traditional laser welded aluminumcopper alloy joints,a red-blue dual-beam laser source and a swinging laser were introduced for welding.T2 copper and 6063 aluminum thin plates were lap welded by coaxial dual-beam laser welding.The morphology of weld cross section was compared to explore the influence of process parameters on the formation of lap joints.The microstructure characteristics of the weld zone were observed and compared by optical microscope.The results show that the addition of laser beam swing can eliminate the internal pores of the weld.With the increase of the swing width,the weld depth decreases,and the weld width increases first and then decreases.The influence of welding speed on the weld cross section morphology is similar to that of swing width.With the increase of welding speed,the weld width increases first and then decreases,while the weld depth decreases all the time.This is because that the red laser is used as the main heat source to melt the base metals,with the increase of red laser power,the weld depth increases.As an auxiliary laser source,blue laser reduces the total energy consumption,consequently,the effective heat input increases and the spatter is restrained effectively.As a result,the increase of red laser power has an enhancement effect on the weld width and weld depth.When the swing width is 1.2 mm,the red laser power is 550 W,the blue laser power is 500 W,and the welding speed is 35 mm/s,the weld forming is the best.The lap joint of T2 copper and 6063 aluminum alloy thin plate can be connected stably with the hybrid of blue laser.The effect rules of laser beam swing on the weld formation were obtained,which improved the quality of the joints. 展开更多
关键词 laser welding aluminum/copper alloy dual beam process parameters weld morphology
下载PDF
Correlation between dose-volume parameters and rectal bleeding after 12 fractions of carbon ion radiotherapy for prostate cancer
16
作者 Takashi Ono Hiraku Sato +5 位作者 Yuya Miyasaka Yasuhito Hagiwara Natsuko Yano Hiroko Akamatsu Mayumi Harada Mayumi Ichikawa 《World Journal of Radiology》 2024年第7期256-264,共9页
BACKGROUND Carbon ion radiotherapy(CIRT)is currently used to treat prostate cancer.Rectal bleeding is a major cause of toxicity even with CIRT.However,to date,a correlation between the dose and volume parameters of th... BACKGROUND Carbon ion radiotherapy(CIRT)is currently used to treat prostate cancer.Rectal bleeding is a major cause of toxicity even with CIRT.However,to date,a correlation between the dose and volume parameters of the 12 fractions of CIRT for prostate cancer and rectal bleeding has not been shown.Similarly,the clinical risk factors for rectal bleeding were absent after 12 fractions of CIRT.AIM To identify the risk factors for rectal bleeding in 12 fractions of CIRT for prostate cancer.METHODS Among 259 patients who received 51.6 Gy[relative biological effectiveness(RBE)],in 12 fractions of CIRT,15 had grade 1(5.8%)and nine had grade 2 rectal bleeding(3.5%).The dose-volume parameters included the volume(cc)of the rectum irradiated with at least x Gy(RBE)(Vx)and the minimum dose in the most irradiated x cc normal rectal volume(Dx).RESULTS The mean values of D6cc,D2cc,V10 Gy(RBE),V20 Gy(RBE),V30 Gy(RBE),and V40 Gy(RBE)were significantly higher in the patients with rectal bleeding than in those without.The cutoff values were D6cc=34.34 Gy(RBE),D2cc=46.46 Gy(RBE),V10 Gy(RBE)=9.85 cc,V20 Gy(RBE)=7.00 cc,V30 Gy(RBE)=6.91 cc,and V40 Gy(RBE)=4.26 cc.The D2cc,V10 Gy(RBE),and V20 Gy(RBE)cutoff values were significant predictors of grade 2 rectal bleeding.CONCLUSION The above dose-volume parameters may serve as guidelines for preventing rectal bleeding after 12 fractions of CIRT for prostate cancer. 展开更多
关键词 Carbon ion radiotherapy Prostate cancer Rectal bleeding Dose volume parameters PREVENTION
下载PDF
Chronic Hepatitis B Virus Infection: Biological Parameters in Patients Treated with Tenofovir Disoproxil Fumarate
17
作者 Sanra Déborah Sanogo Moussa Y. Dicko +10 位作者 Lamine N’Diaye Ousmane Diarra Drissa Katilé Abdoulaye Maiga Ouatou Mallé Sabine Drabo Makan S. Tounkara Hourouma Sow Kadiatou Doumbia Anselme Konaté Moussa T. Diarra 《Open Journal of Gastroenterology》 CAS 2024年第4期145-151,共7页
Chronic hepatitis B causes a liver disease characterized by inflammation of the liver parenchyma. The aim of this study was to investigate the evolution of biological parameters in patients treated with Tenofovir for ... Chronic hepatitis B causes a liver disease characterized by inflammation of the liver parenchyma. The aim of this study was to investigate the evolution of biological parameters in patients treated with Tenofovir for chronic B infection at the Commune V referral health center in Bamako. We obtained a prevalence of 14.15%. The most represented age group was 31 - 40 years, with 36.8%. The sex ratio was 1.44 in favour of men. Viral load was undetectable after 18 months of treatment in 25 patients (42.37%). Tenofovir, the 1st-line drug in Mali, is effective on the biological parameters monitored in patients. 展开更多
关键词 Viral Hepatitis B TENOFOVIR Biological parameters
下载PDF
Effects of Fresh Cupressus sempervirens Leaves Infusion on Growth Performance, Intestinal Microbiota and Haemato-Biochemical Parameters in Broilers
18
作者 Donfack Mikael Noumbissi Marie Noël Bertine +7 位作者 Ciemeni Michelle Aimee Tindo Tsamene Romario Evelyn Ngwa Bih Djamen Tchantchou Chamberlin Nyembo Kondo Camile Tsafong Jeatsa Franklain Necdem Tsafack Boris Kana Jean Raphaël 《Open Journal of Animal Sciences》 2024年第2期70-87,共18页
The accumulation of growth-promoting antibiotic residues in animal products and the resistance developed by bacteria in poultry farms has led to a search for natural compounds derived from plants. This study was desig... The accumulation of growth-promoting antibiotic residues in animal products and the resistance developed by bacteria in poultry farms has led to a search for natural compounds derived from plants. This study was designed to promote the production performance of broiler chickens using fresh Cupressus sempervirens leaves infusion. Fresh Cupressus sempervirens leaves were harvested, washed, chopped and ground to a paste using a blender and fermented for three days in a closed container at a rate of 500 g/L of water. The solution obtained was filtered and added at the rate of 2, 4, 6, 8 and 10 ml/L of drinking water. The chickens fed on the graded level of the solution were compared to a control ration without an additive and positive control group supplemented with 1 g antibiotic/kg feed. At the finisher phase and throughout the study period, water intake increased significantly (P < 0.05) with increasing levels of infusion. Feed intake decreased significantly (P < 0.05) with 2 and 4 ml of infusion/L drinking water. Live weight and weight gain were significantly (P < 0.05) higher with 6 ml/L, while feed conversion significantly (P < 0.05) decreased with the same treatment compared with the control treatment without additives (T0). Carcass characteristics were not significantly (P > 0.05) affected by the inclusion of Cupressus sempervirens infusion. Haematological parameters significantly (P < 0.05) increase independently of the rate of incorporation of the infusion into the drinking water, with the exception of RBCs, MCHT and PCT. Serum content in total protein, globulins, LDL cholesterol and triglycerides were significantly (P < 0.05) high with 8 and 10 ml Cupressus sempervirens infusion/litre drinking water as compared to all other treatments. AST, ALT, urea, creatine, albumin, total cholesterol and HDL-cholesterol were not significantly affected. The lactic acid bacteria load increased significantly (P E. coli and salmonella counts decreased significantly (P < 0.05) with infusion compared to the control without additive. In conclusion, 6 ml of Cupressus sempervirens infusion can be used as an alternative to antibiotic feed additives to promote growth performance in broilers. 展开更多
关键词 BROILERS Cupressus sempervirens Growth Performance Haemato-Biochemical parameters Intestinal Microbiota
下载PDF
Surface Water Quality Profiling Using Physicochemical Parameters in Open Defecation Free and Non-Open Defecation Free Local Government Areas in Benue State, Nigeria
19
作者 Moses T. Asoo Celestine U. Aguoru +1 位作者 Innocent O. Ogbonna Hyacinth O.A. Oluma 《Open Journal of Modern Hydrology》 CAS 2024年第3期174-191,共18页
Physicochemical parameters of surface water sources in the study of local government areas (LGAs) were assessed using standard procedures. The mean physicochemical parameters for pH (5.49), NO2 (0.23 mg/L), SO4 (0.77 ... Physicochemical parameters of surface water sources in the study of local government areas (LGAs) were assessed using standard procedures. The mean physicochemical parameters for pH (5.49), NO2 (0.23 mg/L), SO4 (0.77 mg/L), Na (28.72 mg/L), Ca (28.94 mg/L), Mg (17.50 mg/L), Cl (11.65 mg/L), TSS (6.27 mg/L), TDS (104.23 mg/L), BOD (2.83 mg/L) and F (0.87 mg/L) were below WHO standards irrespective of their defecation status. The values for electrical conductivity (EC) (2770.50 µs/cm, turbidity (481.24 NTU), dissolved oxygen (DO) (5.32 mg/L), chemical oxygen demand (COD) (445.50 mg/L), K (125.06 mg/L), PO4 (0.78 mg/L) and Fe (0.57 mg/L) were above the WHO limits for safe water. Higher EC and COD values obtained in the study is evidence of pollution of the water sources by organic matter. 展开更多
关键词 Open Defecation Surface Water Water Quality Standard Physicochemical parameters
下载PDF
Analysis of the Quality of Physical and Chemical Parameters of Groundwater in Three Localities in the Sub-Prefecture of Zanzra (Ivory Coast)
20
作者 Djedjess Essoh Jules-César Meledje Bi Irié Marc Gouli +3 位作者 Drissa Ouattara Kra Vanh Eric-Simon Zran Adjourma Konate Albert Trokourey 《Journal of Materials Science and Chemical Engineering》 2024年第4期1-17,共17页
The availability of groundwater of acceptable quality has become a difficult challenge to meet in many countries, particularly Côte d’Ivoire. The State of Côte d’Ivoire and rural populations are building h... The availability of groundwater of acceptable quality has become a difficult challenge to meet in many countries, particularly Côte d’Ivoire. The State of Côte d’Ivoire and rural populations are building hydraulic infrastructure for this purpose. However, the quality of water coming from these infrastructures remains to be determined. This study therefore aims to analyze certain physicochemical parameters of the groundwater of Gloazra, Kouezra and Trahonfla. These are temperature, pH, electrical conductivity, TDS, salinity level, hardness, alkalinity, chloride content and bicarbonate. To determine the pH, electrical conductivity, temperature, TDS, and salinity rate, an electrochemical analysis was carried out. The titrimetric analysis made it possible to determine the chloride and bicarbonate content, alkalinity, and hardness. The results indicate that the studied groundwater is soft and acidic with good mineralization. This water does not present a health hazard to consumers but can affect hydraulic equipment and household containers. 展开更多
关键词 Ivory Coast Gloazra Trahonfla Kouezra Physicochemical parameters Water WHO Standards
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部