The aim of this study is to assess the performance objectives defined in the Iraqi Seismic Code (ISC) in order to make a realistic evaluation related to Performance-Based Seismic Design (PBSD) of multi-story reinforce...The aim of this study is to assess the performance objectives defined in the Iraqi Seismic Code (ISC) in order to make a realistic evaluation related to Performance-Based Seismic Design (PBSD) of multi-story reinforced concrete buildings and also to compare and evaluate structural response demands obtained from nonlinear static analysis procedures according to two versions of the capacity spectrum method (CSM) which are recommended in ATC 40 and ATC 55. Two groups of three-dimensional RC buildings with different heights, designed according to Iraqi Building Code Requirements for Reinforced Concrete (IBC), are investigated. Pushover analyses are carried out to determine the nonlinear behavior of the buildings under three different seismic hazard levels, for two Iraqi seismic zones, of earthquake loads. In order to determine performance levels of the buildings, maximum inter-story drift demands and plasticizing sequence are determined and compared with the related limits using the CSM recommended in ATC 40 and ATC 55. From the results of this research, it can be concluded that RC buildings designed according to the Iraqi codes sufficiently provide the performance objectives stipulated in the ISC. Comparing structural response quantities obtained from the two versions of CSM, effects on performance evaluations of the buildings are investigated comparatively, as well.展开更多
In past two decades earthquake disasters in the world have shown that significant damage occurred even when the buildings were designed as per the conventional earthquake-resistant design philosophy (force-based appro...In past two decades earthquake disasters in the world have shown that significant damage occurred even when the buildings were designed as per the conventional earthquake-resistant design philosophy (force-based approach) exposing the inability of the codes to ensure minimum performance of the structures under design earthquake. The performance based seismic design (PBSD), evaluates how the buildings are likely to perform under a design earthquake. As compared to force-based approach, PBSD provides a methodology for assessing the seismic performance of a building, ensuring life safety and minimum economic losses. The non-linear static procedures also known as pushover analysis are used to analyze the performance of structure under lateral loads. Pushover analysis gives pattern of the plastic hinge formations in structural members along with other structural parameters which directly show the performance of member after an earthquake event. In this paper, a four-storey RC building is modelled and designed as per IS 456:2000 and analyzed for life safety performance level in SAP2000 v17. Analysis is carried out as per ATC 40 to find out storey drift, pushover curve, capacity spectrum curve, performance point and plastic hinges as per FEMA 273 in SAP2000 v17. From the analysis, it is checked that the performance level of the building is as per the assumption.展开更多
文摘The aim of this study is to assess the performance objectives defined in the Iraqi Seismic Code (ISC) in order to make a realistic evaluation related to Performance-Based Seismic Design (PBSD) of multi-story reinforced concrete buildings and also to compare and evaluate structural response demands obtained from nonlinear static analysis procedures according to two versions of the capacity spectrum method (CSM) which are recommended in ATC 40 and ATC 55. Two groups of three-dimensional RC buildings with different heights, designed according to Iraqi Building Code Requirements for Reinforced Concrete (IBC), are investigated. Pushover analyses are carried out to determine the nonlinear behavior of the buildings under three different seismic hazard levels, for two Iraqi seismic zones, of earthquake loads. In order to determine performance levels of the buildings, maximum inter-story drift demands and plasticizing sequence are determined and compared with the related limits using the CSM recommended in ATC 40 and ATC 55. From the results of this research, it can be concluded that RC buildings designed according to the Iraqi codes sufficiently provide the performance objectives stipulated in the ISC. Comparing structural response quantities obtained from the two versions of CSM, effects on performance evaluations of the buildings are investigated comparatively, as well.
文摘In past two decades earthquake disasters in the world have shown that significant damage occurred even when the buildings were designed as per the conventional earthquake-resistant design philosophy (force-based approach) exposing the inability of the codes to ensure minimum performance of the structures under design earthquake. The performance based seismic design (PBSD), evaluates how the buildings are likely to perform under a design earthquake. As compared to force-based approach, PBSD provides a methodology for assessing the seismic performance of a building, ensuring life safety and minimum economic losses. The non-linear static procedures also known as pushover analysis are used to analyze the performance of structure under lateral loads. Pushover analysis gives pattern of the plastic hinge formations in structural members along with other structural parameters which directly show the performance of member after an earthquake event. In this paper, a four-storey RC building is modelled and designed as per IS 456:2000 and analyzed for life safety performance level in SAP2000 v17. Analysis is carried out as per ATC 40 to find out storey drift, pushover curve, capacity spectrum curve, performance point and plastic hinges as per FEMA 273 in SAP2000 v17. From the analysis, it is checked that the performance level of the building is as per the assumption.
基金the National Key Research and Development Program of China under Grant No.2016YFC0802205the Department of Science and Technology of Sichuan Province under Grant No.2019YJ0221.