Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20...Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application.展开更多
Orthopedic bone plates are most commonly used for bone fracture fixation for more than 100 years.The bone plate design had evolved over time overcoming many challenges such as insufficient strength and excessive plate...Orthopedic bone plates are most commonly used for bone fracture fixation for more than 100 years.The bone plate design had evolved over time overcoming many challenges such as insufficient strength and excessive plate–bone contact affecting the blood circulation.However,it is only made of two materials,either stainless steel(AISI 316L)or titanium(Ti–6Al–4V).There are two main limitations of metallic bone implants,namely stress shielding and the problem of malocclusion caused by the displacement of the fracture site during healing.To overcome the two problems,a new bone plate design with the incorporation of auxetic structures is proposed in this work.This study aims to use auxetic structure section in the bone plate that would decrease the stiffness of the region,thereby mitigating the stress-shielding effect and at the same time act as a deformable section to enable intra-operative bending for effective alignment while having enough bending strength and stiffness.Two different auxetic structures namely re-entrant honeycomb and missing rib structures were considered.The auxetic structure incorporated bone plates were designed,finite element analysis was done,fabricated using direct metal laser sintering technique,and tested.The results indicate that the re-entrant honeycomb structure incorporated bone plates serve as an effective bone design compared to the conventional bone plate design,in terms of stress shielding and intra-operative bending while offering similar mechanical and bending strength.展开更多
BACKGROUND The epiphyseal growth plate is an important anatomical segment localized on the ends of a long bone.Despite the abovementioned atractive reasons for alendronate’s use,few data on the effect of alendronate ...BACKGROUND The epiphyseal growth plate is an important anatomical segment localized on the ends of a long bone.Despite the abovementioned atractive reasons for alendronate’s use,few data on the effect of alendronate during epiphyseal growth exist.AIM Verify the effect of alendronate on the growth epiphyseal plate,and compare its effect with the size of the femur during the double-staining of the immunolocalization of transforming growth factor-β1(TGF-β1)and bone morphogenetic protein-2(BMP2)in endochondral ossifing in specimens that have received alendronate.METHODS Forty newborn rats were randomly divided into two groups:a control group(were given applications of 1 mg/kg physiologic saline)and a group that received Alendronate(a dose of 2.5 mg/kg).These groups were then divided into two subgroups for euthanasia in two and 12 d of life.After euthanasia,the femurs were removed,and the femoral bones were measured linearly between the apex of the greater trochanter until the lower intercondylar midlle face to verify the probable bone growth between 3 and 12 d in control and alednroanto treated rats.Posteriorly,the surgical pieces were also sent to the histopathology laboratory to produce histological slides.The obtained slides were stained with hematoxylin and eosin to measure each of the cartilage zones in endochondral development.and other slides were immunohistochemically tested for anti-TGF-β1 and BMP-2 antibodies to investigate the immunolocalization of these proteins in the epiphyseal plaque area.RESULTS On the third day,some diferences between the control group and specimens treated with alendronate were verified.Macroscopiccaly,we found similarities in size between the femoral bones when we compared the control group with the specimens that received alendronate.On the 12^th day,the bone size of the mice receiving the drug was significantly smaller than those of the control group.These results coincide with changes in the TGF-β1 and BMP-2 expression.In the specimens that received alendronate,the TGF-β1 was expressed in some sites of trabecular bone that was neoformed,peripherally to the bone marrow area.The BMP-2 was also positive in proliferative chondrocytes and hypertrofic chondrocytes.On the 12^th day,all layers of chondrocytes exhibited positivity for BMP-2 in the specimens that received alendronate.In the interface between the trabecular bone and cartilage,an area of disorganized bone deposition was evident.Neoformed bone also appeared to be different at 12 d.In the control group,BMP-2 was positive in an intense area of bone trabeculae,whereas the alendronate-treated group showed TGF-β1 positive trabeculae and a greater bone area.CONCLUSION Alendronate alters the immunolocalization of TGF-β1 and BMP-2 simultaneously,a condition that changes the usual histological aspects of the cartilage zone and impairs epiphysis growth and femur growth.展开更多
AIM: To determine whether use of a precontoured olecranon plate provides adequate fixation to withstand supraphysiologic force in a comminuted olecranon fracture model.METHODS: Five samples of fourth generation compos...AIM: To determine whether use of a precontoured olecranon plate provides adequate fixation to withstand supraphysiologic force in a comminuted olecranon fracture model.METHODS: Five samples of fourth generation composite bones and five samples of fresh frozen human cadaveric left ulnae were utilized for this study. The cadaveric specimens underwent dual-energy X-ray absorptiometry(DEXA) scanning to quantify the bone quality. The composite and cadaveric bones were prepared by creating a comminuted olecranon fracture and fixed with a pre-contoured olecranon plate with locking screws. Construct stiffness and failure load were measured by subjecting specimens to cantilever bending moments until failure. Fracture site motion was measured with differential variable resistance transducer spanning the fracture. Statistical analysis was performed with two-tailed Mann-Whitney-U test with Monte Carlo Exact test.RESULTS: There was a significant difference in fixation stiffness and strength between the composite bones and human cadaver bones. Failure modes differed in cadaveric and composite specimens. The load to failure for the composite bones(n = 5) and human cadaver bones(n = 5) specimens were 10.67 nm(range 9.40-11.91 nm) and 13.05 nm(range 12.59-15.38 nm) respectively. This difference was statistically significant(P ? 0.007, 97% power). Median stiffness for composite bones and human cadaver bones specimens were 5.69 nm/mm(range 4.69-6.80 nm/mm) and 7.55 nm/mm(range 6.31-7.72 nm/mm). There was a significant difference for stiffness(P ? 0.033, 79% power) between composite bones and cadaveric bones. No correlation was found between the DEXA results and stiffness. All cadaveric specimens withstood the physiologic load anticipated postoperatively. Catastrophic failure occurred in all composite specimens. All failures resulted from composite bone failure at the distal screw site and not hardware failure. There were no catastrophic fracture failures in the cadaveric specimens. Failure of 4/5 cadaveric specimens was defined when a fracture gap of 2 mm was observed, but 1/5 cadaveric specimens failed due to a failure of the triceps mechanism. All failures occurred at forces greater than that expected in postoperative period prior to healing.CONCLUSION: The pre-contoured olecranon plate provides adequate fixation to withstand physiologic force in a composite bone and cadaveric comminuted olecranon fracture model.展开更多
The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a ...The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a bone/metal interface in biointegration after implanted into the mandible of dog. Though a bone/metal interface in osseointegration was also formed on the surface of uncoated 317L plate screw after implantation, a smal1 space was seen between the bone and surface of the screw, indicating that the tissue compatibility of titanium-coated 317L plate screw may be better than that of the non-coated screw.展开更多
The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the funct...The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.展开更多
Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with R...Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with Robinson 2A and 2B middle clavicular fractures admitted to our hospital between March 2017 and January 2019 were divided into the control group(n=41)receiving conventional kirschner wire internal fixation and the observation group(n=39)receiving locking compression plate internal fixation according to the operation plans.The differences in serum contents of inflammatory factors,oxidative stress indexes and bone metabolism indexes were compared between the two groups of patients before patients entered operating room,24 h after surgery and 48 h after surgery.Results:Before patients entered operating room,there were no statistically significant differences in the serum contents of inflammatory factors,oxidative stress indexes or bone metabolism indexes between the two groups(P>0.05).At 24 h and 48 h after surgery,serum inflammatory factors interleukin-1(IL-1),interleukin-17(IL-17),high-sensitivity C-reactive protein(hs-CRP)and tumor necrosis factorα(TNF-α)contents in the observation group were lower than those in the control group;serum reactive oxygen species(ROS)and lipid hydroperoxide(LHP)contents were lower than those in the control group,while catalase(CAT)and glutathione peroxidase(GSH-Px)contents were higher than those in the control group;serum N-terminal propeptide of procollagen type I(PINP),bone gla protein(BGP)and alkaline phosphatase(ALP)contents were higher than those in the control group,while N-telopeptide of typeⅠcollagen(NTX),C-telopeptide of typeⅠcollagen(CTX)and tartrate-resistant acid phosphatase 5b(TRACP5b)contents were lower than those in the control group(P<0.05).Conclusion:Locking compression plate internal fixation can reduce the postoperative trauma extent and help promote the fracture healing in patients with Robinson 2A and 2B middle clavicular fracture.展开更多
Introduction: Pseudarthrosis (PSA) of the diaphysis of long bones still remains a current problem, despite improvements in the treatment of these fractures. Our study aims to study the epidemiological and therapeutic ...Introduction: Pseudarthrosis (PSA) of the diaphysis of long bones still remains a current problem, despite improvements in the treatment of these fractures. Our study aims to study the epidemiological and therapeutic aspects of PSA of the diaphysis of long bones. Method: This retrospective work concerns 30 cases of non-union of the diaphysis of long bones treated in the orthopedic and trauma surgery department at Donka National Hospital, during a period of 18 months from January 1, 2019 to June 30, 2020. Results: We recruited 30 patients, 80% of whom were male, with an average age of 39.9 years. Public road accidents (AVP) represented the main cause of fractures of the diaphysis of long bones 87%, they were open in 25 cases or 83%. The fractures were located in the middle 1/3 of the diaphysis of the long bones in 50% of cases. Treatment of initial fractures was traditional in 21 cases, orthopedic in 2 cases and surgical in 7 cases. It was aseptic nonunion in 28 cases (93%) and septic nonunion in 2 cases. They were hypertrophic in 7 cases, slightly hypertrophic in 5 cases, oligotrophic in 11 cases, atrophic in 6 cases and with bone defect in 1 case. The treatment was based on osteosynthesis including 16 cases of screwed “PV” plate: 7 cases of centromedullary “ECM” nailing, 2 cases of external fixator, 1 case of broaching and 4 cases of Plastering. The results according to ASAMI criteria on an anatomical level were excellent in 19 cases, good in 3 cases and poor in 3 cases, with a union rate of 76%. And 5 patients undergoing consolidation. Conclusion: Based on the literature data and the experience of our department, the true treatment of PSA requires correct management of the initial fracture without forgetting the interest in preventing AVP which appears to be an element essential, making it possible to reduce the incidence of fractures of the diaphysis.展开更多
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin...To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab.展开更多
Acetabular component revision in the presence of severe bone loss is difficult for reconstructing an acetabular component in the anatomical hip center. Various treatment options are available, although often the aceta...Acetabular component revision in the presence of severe bone loss is difficult for reconstructing an acetabular component in the anatomical hip center. Various treatment options are available, although often the acetabular defect cannot be corrected with a single option alone. Precise assessment of the bone loss and a suitable combination of methods are needed. Here we report a case of multiple failures with impaction bone grafting reconstruction for an acetabular bone defect of American Academy of Orthopedic Surgeons classification type III. We finally reconstructed the acetabulum with three femoral head allografts and a Kerboull-type acetabular reinforcement device. The allograft was a casted, jet-type helmet-like shape. A year later the patient was able to walk without a cane and perform light agricultural work. Accurate evaluation of the acetabular bone loss and appropriate reconstruction is important.展开更多
<b><span>Purpose</span></b><b><span>: </span></b><span>The purpose </span><span>of </span><span>this study was to define a treatment protoc...<b><span>Purpose</span></b><b><span>: </span></b><span>The purpose </span><span>of </span><span>this study was to define a treatment protocol in which a non-vascularized endosteal fibular strut graft, a corticocancellous grafts and a locking plate construct </span><span>are</span><span> used for stabilization of the delayed and neglected proximal humerus fractures and to report its outcome. </span><b><span>Patients & Methods</span></b><b><span>:</span></b><b><span> </span></b><span>Eleven patients (6 females and 5 males) with delayed, neglected proximal humerus fractures were included in this study,</span><span> </span><span>conducted between March 2015 </span><span>and </span><span>December 2019.</span><span> </span><span>Average age of the patients was 57 years (range: 41 to 67 yrs). All patients were treated with the debridement, decortication and shingling of the bone at the site of the fracture followed by using an endosteal fibular strut graft, corticocancellous bone grafts and stabilization with locking plate. The patients were followed</span><span> </span><span>up for a mean time of 16.3 months (range: 13 </span><span>to </span><span>40 months). The patient outcomes were evaluated using the Disabilities of the Arm, Shoulder, and Hand Questionnaire, and the modified scoring system of Constant and Murley. </span><b><span>Results</span></b><b><span>:</span></b><b><span> </span></b><span>Union at the fracture site was achieved in all patients at a mean </span><span>of </span><span>8.5 months (range: 6 to 11 months). The DASH score improved from an average pre-operative score of 71.1 (range: 64 to 78) to an average post-operative score of 25.2 (range: 21 to 35) at the final follow-up. Albeit with a small sample size of n</span><span> </span><span>=</span><span> </span><span>11, this difference was found to be statistically significant (p</span><span> </span><span><</span><span> </span><span>0.05). The CM score improved from an average pre-operative score of 33.2 (range: 20 to 48) to an average post-operative score of 66.8 (range: 59 to 72) at the final follow-up. This difference was also found to be statistically significant in this patient cohort (p</span><span> </span><span><</span><span> </span><span>0.05). The results were excellent in 3 patients, good in 6 and moderate in 2. </span><b><span>Conclusions</span></b><b><span>:</span></b><b><span> </span></b><span>An endosteal fibular strut, subperiosteally placed cortico-cancellous grafts with a locking plate fixation helps in biological healing of neglected fractures of proximal humerus.</span>展开更多
Background: Chondrocytes in the growth plate(GP) undergo increases in volume during different cascades of cell differentiation during longitudinal bone growth. The volume increase is reported to be the most significan...Background: Chondrocytes in the growth plate(GP) undergo increases in volume during different cascades of cell differentiation during longitudinal bone growth. The volume increase is reported to be the most significant variable in understanding the mechanism of long bone growth.Methods: Forty-five postnatal Sprague-Dawley rat pups, 7-15 days old were divided into nine age groups(P7-P15). Five pups were allocated to each group. The rats were sacrificed and tibia and metatarsal bones were harvested. Bone lengths were measured after 0, 24, 48, and 72 hours of ex vivo incubation. Histology of bones was carried out, and GP lengths and chondrocyte densities were determined.Results: There were significant differences in bone length among the age groups after 0 and 72 hours of incubation. Histological sectioning was possible in metatarsal bone from all age groups, and in tibia from 7-to 13-day-old rats. No significant differences in tibia and metatarsal GP lengths were seen among different age groups at 0 and 72 hours of incubation. Significant differences in chondrocyte densities along the epiphyseal GP of the bones between 0 and 72 hours of incubation were observed in most of the age groups.Conclusion: Ex vivo growth of tibia and metatarsal bones of rats aged 7-15 days old is possible, with percentage growth rates of 23.87 ± 0.80% and 40.38 ± 0.95%measured in tibia and metatarsal bone, respectively. Histological sectioning of bones was carried out without the need for decalcification in P7-P13 tibia and P7-P15 metatarsal bone. Increases in chondrocyte density along the GP influence overall bone elongation.展开更多
文摘Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application.
文摘Orthopedic bone plates are most commonly used for bone fracture fixation for more than 100 years.The bone plate design had evolved over time overcoming many challenges such as insufficient strength and excessive plate–bone contact affecting the blood circulation.However,it is only made of two materials,either stainless steel(AISI 316L)or titanium(Ti–6Al–4V).There are two main limitations of metallic bone implants,namely stress shielding and the problem of malocclusion caused by the displacement of the fracture site during healing.To overcome the two problems,a new bone plate design with the incorporation of auxetic structures is proposed in this work.This study aims to use auxetic structure section in the bone plate that would decrease the stiffness of the region,thereby mitigating the stress-shielding effect and at the same time act as a deformable section to enable intra-operative bending for effective alignment while having enough bending strength and stiffness.Two different auxetic structures namely re-entrant honeycomb and missing rib structures were considered.The auxetic structure incorporated bone plates were designed,finite element analysis was done,fabricated using direct metal laser sintering technique,and tested.The results indicate that the re-entrant honeycomb structure incorporated bone plates serve as an effective bone design compared to the conventional bone plate design,in terms of stress shielding and intra-operative bending while offering similar mechanical and bending strength.
文摘BACKGROUND The epiphyseal growth plate is an important anatomical segment localized on the ends of a long bone.Despite the abovementioned atractive reasons for alendronate’s use,few data on the effect of alendronate during epiphyseal growth exist.AIM Verify the effect of alendronate on the growth epiphyseal plate,and compare its effect with the size of the femur during the double-staining of the immunolocalization of transforming growth factor-β1(TGF-β1)and bone morphogenetic protein-2(BMP2)in endochondral ossifing in specimens that have received alendronate.METHODS Forty newborn rats were randomly divided into two groups:a control group(were given applications of 1 mg/kg physiologic saline)and a group that received Alendronate(a dose of 2.5 mg/kg).These groups were then divided into two subgroups for euthanasia in two and 12 d of life.After euthanasia,the femurs were removed,and the femoral bones were measured linearly between the apex of the greater trochanter until the lower intercondylar midlle face to verify the probable bone growth between 3 and 12 d in control and alednroanto treated rats.Posteriorly,the surgical pieces were also sent to the histopathology laboratory to produce histological slides.The obtained slides were stained with hematoxylin and eosin to measure each of the cartilage zones in endochondral development.and other slides were immunohistochemically tested for anti-TGF-β1 and BMP-2 antibodies to investigate the immunolocalization of these proteins in the epiphyseal plaque area.RESULTS On the third day,some diferences between the control group and specimens treated with alendronate were verified.Macroscopiccaly,we found similarities in size between the femoral bones when we compared the control group with the specimens that received alendronate.On the 12^th day,the bone size of the mice receiving the drug was significantly smaller than those of the control group.These results coincide with changes in the TGF-β1 and BMP-2 expression.In the specimens that received alendronate,the TGF-β1 was expressed in some sites of trabecular bone that was neoformed,peripherally to the bone marrow area.The BMP-2 was also positive in proliferative chondrocytes and hypertrofic chondrocytes.On the 12^th day,all layers of chondrocytes exhibited positivity for BMP-2 in the specimens that received alendronate.In the interface between the trabecular bone and cartilage,an area of disorganized bone deposition was evident.Neoformed bone also appeared to be different at 12 d.In the control group,BMP-2 was positive in an intense area of bone trabeculae,whereas the alendronate-treated group showed TGF-β1 positive trabeculae and a greater bone area.CONCLUSION Alendronate alters the immunolocalization of TGF-β1 and BMP-2 simultaneously,a condition that changes the usual histological aspects of the cartilage zone and impairs epiphysis growth and femur growth.
文摘AIM: To determine whether use of a precontoured olecranon plate provides adequate fixation to withstand supraphysiologic force in a comminuted olecranon fracture model.METHODS: Five samples of fourth generation composite bones and five samples of fresh frozen human cadaveric left ulnae were utilized for this study. The cadaveric specimens underwent dual-energy X-ray absorptiometry(DEXA) scanning to quantify the bone quality. The composite and cadaveric bones were prepared by creating a comminuted olecranon fracture and fixed with a pre-contoured olecranon plate with locking screws. Construct stiffness and failure load were measured by subjecting specimens to cantilever bending moments until failure. Fracture site motion was measured with differential variable resistance transducer spanning the fracture. Statistical analysis was performed with two-tailed Mann-Whitney-U test with Monte Carlo Exact test.RESULTS: There was a significant difference in fixation stiffness and strength between the composite bones and human cadaver bones. Failure modes differed in cadaveric and composite specimens. The load to failure for the composite bones(n = 5) and human cadaver bones(n = 5) specimens were 10.67 nm(range 9.40-11.91 nm) and 13.05 nm(range 12.59-15.38 nm) respectively. This difference was statistically significant(P ? 0.007, 97% power). Median stiffness for composite bones and human cadaver bones specimens were 5.69 nm/mm(range 4.69-6.80 nm/mm) and 7.55 nm/mm(range 6.31-7.72 nm/mm). There was a significant difference for stiffness(P ? 0.033, 79% power) between composite bones and cadaveric bones. No correlation was found between the DEXA results and stiffness. All cadaveric specimens withstood the physiologic load anticipated postoperatively. Catastrophic failure occurred in all composite specimens. All failures resulted from composite bone failure at the distal screw site and not hardware failure. There were no catastrophic fracture failures in the cadaveric specimens. Failure of 4/5 cadaveric specimens was defined when a fracture gap of 2 mm was observed, but 1/5 cadaveric specimens failed due to a failure of the triceps mechanism. All failures occurred at forces greater than that expected in postoperative period prior to healing.CONCLUSION: The pre-contoured olecranon plate provides adequate fixation to withstand physiologic force in a composite bone and cadaveric comminuted olecranon fracture model.
文摘The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a bone/metal interface in biointegration after implanted into the mandible of dog. Though a bone/metal interface in osseointegration was also formed on the surface of uncoated 317L plate screw after implantation, a smal1 space was seen between the bone and surface of the screw, indicating that the tissue compatibility of titanium-coated 317L plate screw may be better than that of the non-coated screw.
文摘The locking compression plates (LCP) are efficient tools in open reduction and internal fixation (ORIF), especially in osteoporotic bones. Two important factors of screw density and screw position can affect the functionality of the bone plate. Several studies have assessed the influence of the screw configurations on the bone-plate stiffness, but the effects of screw positions on the interfragmentary strain, εIF of LCP construct have not been investigated yet. In this study, finite element method was used to investigate the influence of screws number and position on the interfragmentary strain of LCP-femur system for a mid-shaft fracture. Results of this study showed that by insertion of screws closer to the fracture site, εIF decreases by 2nd degree polynomial function versus screw position, but by adding the screws from the ends of the plate, or by moving and placing the screws towards the fracture site, the reduction of εIF will be linear. Results of this study were compared and are in agreement with some studies in the literature, even though their scope was mostly stability of the bone-implant system, whereas our scope was focused on the interfragmentary strain.
基金Application and clinical characteristics of Ilizarov technique in the treatment of bone defect,No:20150802.
文摘Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with Robinson 2A and 2B middle clavicular fractures admitted to our hospital between March 2017 and January 2019 were divided into the control group(n=41)receiving conventional kirschner wire internal fixation and the observation group(n=39)receiving locking compression plate internal fixation according to the operation plans.The differences in serum contents of inflammatory factors,oxidative stress indexes and bone metabolism indexes were compared between the two groups of patients before patients entered operating room,24 h after surgery and 48 h after surgery.Results:Before patients entered operating room,there were no statistically significant differences in the serum contents of inflammatory factors,oxidative stress indexes or bone metabolism indexes between the two groups(P>0.05).At 24 h and 48 h after surgery,serum inflammatory factors interleukin-1(IL-1),interleukin-17(IL-17),high-sensitivity C-reactive protein(hs-CRP)and tumor necrosis factorα(TNF-α)contents in the observation group were lower than those in the control group;serum reactive oxygen species(ROS)and lipid hydroperoxide(LHP)contents were lower than those in the control group,while catalase(CAT)and glutathione peroxidase(GSH-Px)contents were higher than those in the control group;serum N-terminal propeptide of procollagen type I(PINP),bone gla protein(BGP)and alkaline phosphatase(ALP)contents were higher than those in the control group,while N-telopeptide of typeⅠcollagen(NTX),C-telopeptide of typeⅠcollagen(CTX)and tartrate-resistant acid phosphatase 5b(TRACP5b)contents were lower than those in the control group(P<0.05).Conclusion:Locking compression plate internal fixation can reduce the postoperative trauma extent and help promote the fracture healing in patients with Robinson 2A and 2B middle clavicular fracture.
文摘Introduction: Pseudarthrosis (PSA) of the diaphysis of long bones still remains a current problem, despite improvements in the treatment of these fractures. Our study aims to study the epidemiological and therapeutic aspects of PSA of the diaphysis of long bones. Method: This retrospective work concerns 30 cases of non-union of the diaphysis of long bones treated in the orthopedic and trauma surgery department at Donka National Hospital, during a period of 18 months from January 1, 2019 to June 30, 2020. Results: We recruited 30 patients, 80% of whom were male, with an average age of 39.9 years. Public road accidents (AVP) represented the main cause of fractures of the diaphysis of long bones 87%, they were open in 25 cases or 83%. The fractures were located in the middle 1/3 of the diaphysis of the long bones in 50% of cases. Treatment of initial fractures was traditional in 21 cases, orthopedic in 2 cases and surgical in 7 cases. It was aseptic nonunion in 28 cases (93%) and septic nonunion in 2 cases. They were hypertrophic in 7 cases, slightly hypertrophic in 5 cases, oligotrophic in 11 cases, atrophic in 6 cases and with bone defect in 1 case. The treatment was based on osteosynthesis including 16 cases of screwed “PV” plate: 7 cases of centromedullary “ECM” nailing, 2 cases of external fixator, 1 case of broaching and 4 cases of Plastering. The results according to ASAMI criteria on an anatomical level were excellent in 19 cases, good in 3 cases and poor in 3 cases, with a union rate of 76%. And 5 patients undergoing consolidation. Conclusion: Based on the literature data and the experience of our department, the true treatment of PSA requires correct management of the initial fracture without forgetting the interest in preventing AVP which appears to be an element essential, making it possible to reduce the incidence of fractures of the diaphysis.
文摘To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab.
文摘Acetabular component revision in the presence of severe bone loss is difficult for reconstructing an acetabular component in the anatomical hip center. Various treatment options are available, although often the acetabular defect cannot be corrected with a single option alone. Precise assessment of the bone loss and a suitable combination of methods are needed. Here we report a case of multiple failures with impaction bone grafting reconstruction for an acetabular bone defect of American Academy of Orthopedic Surgeons classification type III. We finally reconstructed the acetabulum with three femoral head allografts and a Kerboull-type acetabular reinforcement device. The allograft was a casted, jet-type helmet-like shape. A year later the patient was able to walk without a cane and perform light agricultural work. Accurate evaluation of the acetabular bone loss and appropriate reconstruction is important.
文摘<b><span>Purpose</span></b><b><span>: </span></b><span>The purpose </span><span>of </span><span>this study was to define a treatment protocol in which a non-vascularized endosteal fibular strut graft, a corticocancellous grafts and a locking plate construct </span><span>are</span><span> used for stabilization of the delayed and neglected proximal humerus fractures and to report its outcome. </span><b><span>Patients & Methods</span></b><b><span>:</span></b><b><span> </span></b><span>Eleven patients (6 females and 5 males) with delayed, neglected proximal humerus fractures were included in this study,</span><span> </span><span>conducted between March 2015 </span><span>and </span><span>December 2019.</span><span> </span><span>Average age of the patients was 57 years (range: 41 to 67 yrs). All patients were treated with the debridement, decortication and shingling of the bone at the site of the fracture followed by using an endosteal fibular strut graft, corticocancellous bone grafts and stabilization with locking plate. The patients were followed</span><span> </span><span>up for a mean time of 16.3 months (range: 13 </span><span>to </span><span>40 months). The patient outcomes were evaluated using the Disabilities of the Arm, Shoulder, and Hand Questionnaire, and the modified scoring system of Constant and Murley. </span><b><span>Results</span></b><b><span>:</span></b><b><span> </span></b><span>Union at the fracture site was achieved in all patients at a mean </span><span>of </span><span>8.5 months (range: 6 to 11 months). The DASH score improved from an average pre-operative score of 71.1 (range: 64 to 78) to an average post-operative score of 25.2 (range: 21 to 35) at the final follow-up. Albeit with a small sample size of n</span><span> </span><span>=</span><span> </span><span>11, this difference was found to be statistically significant (p</span><span> </span><span><</span><span> </span><span>0.05). The CM score improved from an average pre-operative score of 33.2 (range: 20 to 48) to an average post-operative score of 66.8 (range: 59 to 72) at the final follow-up. This difference was also found to be statistically significant in this patient cohort (p</span><span> </span><span><</span><span> </span><span>0.05). The results were excellent in 3 patients, good in 6 and moderate in 2. </span><b><span>Conclusions</span></b><b><span>:</span></b><b><span> </span></b><span>An endosteal fibular strut, subperiosteally placed cortico-cancellous grafts with a locking plate fixation helps in biological healing of neglected fractures of proximal humerus.</span>
基金Ministry of Higher Education Malaysia,Grant/Award Number:FRGS/1/2012/SGO5/UPM/02/9
文摘Background: Chondrocytes in the growth plate(GP) undergo increases in volume during different cascades of cell differentiation during longitudinal bone growth. The volume increase is reported to be the most significant variable in understanding the mechanism of long bone growth.Methods: Forty-five postnatal Sprague-Dawley rat pups, 7-15 days old were divided into nine age groups(P7-P15). Five pups were allocated to each group. The rats were sacrificed and tibia and metatarsal bones were harvested. Bone lengths were measured after 0, 24, 48, and 72 hours of ex vivo incubation. Histology of bones was carried out, and GP lengths and chondrocyte densities were determined.Results: There were significant differences in bone length among the age groups after 0 and 72 hours of incubation. Histological sectioning was possible in metatarsal bone from all age groups, and in tibia from 7-to 13-day-old rats. No significant differences in tibia and metatarsal GP lengths were seen among different age groups at 0 and 72 hours of incubation. Significant differences in chondrocyte densities along the epiphyseal GP of the bones between 0 and 72 hours of incubation were observed in most of the age groups.Conclusion: Ex vivo growth of tibia and metatarsal bones of rats aged 7-15 days old is possible, with percentage growth rates of 23.87 ± 0.80% and 40.38 ± 0.95%measured in tibia and metatarsal bone, respectively. Histological sectioning of bones was carried out without the need for decalcification in P7-P13 tibia and P7-P15 metatarsal bone. Increases in chondrocyte density along the GP influence overall bone elongation.