A STUDY OF STRUCTURE AND PROPERTY CHANGES OF BIODEGRADABLE POLYGLYCOLIDE AND POLY(GLYCOLIDE-co-LACTIDE)FIBERS DURING PROCESSING AND IN VITRO DEGRADATION 被引量:10
1
作者 Bruce X.Fu Benjamin S.Hsiao +7 位作者 Gavin Chen Jack Zhou Susan Lin Jenny Yuan Ilya Koyfman Dennis D Jamiolkowski Edward Dormier 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2003年第2期159-167,共9页
Structure and properties of bioabsorbable polyglycolide (PGA) and poly(glycolide-co-lactide) (PGA-co-PLA)fibers were investigated during several industrial processing stages and in vitro degradation by means of wide-a... Structure and properties of bioabsorbable polyglycolide (PGA) and poly(glycolide-co-lactide) (PGA-co-PLA)fibers were investigated during several industrial processing stages and in vitro degradation by means of wide-angle X-raydiffraction (WAXD), dynamic mechanical analysis (DMA) and mechanical property tests. In the orientation stage, the PGAfibers were found to have higher degrees of crystallinity than corresponding PGA-co-PLA samples produced under similarconditions. In the hot-stretching and post-annealing stages, after fibers were braided, PGA samples were found to gain morecrystallinity and higher T_g than PGA-co-PLA samples. The higher crystallinity in PGA fibers resulted in a slower rate ofdegradation. DMA results showed that a great deal of internal stress that was built during orientation and hot-stretchingstages was released in the post-annealing stage for a1l PGA and PGA-co-PLA samples. During earlier stages of in vitrodegradation, both PGA and PGA-co-PLA samples exhibited the typical cleavage-induced crystallization mechanism. Theheat shrinkage in the glass transition area was found to disappear after 6-8 days of degradation for all PGA and PGA-co-PLAsamples, indicating the amorphous portions of the polymers lost orientation after a short period in the buffer solution, mostlikely due to relaxation of the cleaved chains. 展开更多
关键词 polyGLYCOLIDE poly(glycolide-co-lactide) BIOABSORBABLE Fiber processing in vitro Degradation
下载PDF
PGLA降解产物对材料降解性能影响的体外研究 被引量:7
2
作者 孙皎 郭尚春 何伟 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2006年第5期1062-1065,共4页
为了探讨PGLA材料的降解产物对材料本体降解性能的影响,本研究设计了体外两种浸泡体系——磷酸缓冲液(PBS)和人工血浆,分别在替换和不替换浸泡介质两组不同条件下,分析材料的质量损耗情况,并将不替换组的各时间段降解液进行pH值... 为了探讨PGLA材料的降解产物对材料本体降解性能的影响,本研究设计了体外两种浸泡体系——磷酸缓冲液(PBS)和人工血浆,分别在替换和不替换浸泡介质两组不同条件下,分析材料的质量损耗情况,并将不替换组的各时间段降解液进行pH值的测定,以判断环境的酸碱度对材料本体降解的作用。实验降解周期分别为2、3、4、6、8、10周。结果显示:在浸泡初期,人工血浆和PBS降解液中的质量损耗两者间无显著性差异(P〉0.05);大约从2周到6周,不替液组中材料在两种介质内的降解速度显著快于相对应的同期换液组(P〈0.01);不替换液组材料在PBS液中的降解快于在人工血浆中的降解,而且在整个降解周期内PBS降解液的pH值基本保持稳定(pH≈7.0~7.4),而人工血浆降解液中的pH值随着降解过程的不断进行,其pH值由7.5逐渐降到5.7左右,两种降解液pH值变化之间的差异具有显著的统计学意义(P〈0.01)。由此提示:在不替换浸泡介质的条件下,降解液中持续存在的降解产物显然影响材料本体的降解速度,PGLA材料的降解产物具有加速材料质量损耗的作用;环境的酸碱度对材料的降解会产生一定的影响,pH值越低,材料的降解速度越缓慢。 展开更多
关键词 聚乙交酯丙交酯 降解产物 酸碱度 体外降解
下载PDF
PGLA牙周引导组织再生片体外降解性能实验研究 被引量:2
3
作者 何伟 孙皎 《实用口腔医学杂志》 CAS CSCD 北大核心 2003年第5期466-469,共4页
目的 :研究PGLA牙周引导组织再生片体外的降解周期 ,并对影响其降解动力学的各种因素作出评价。方法 :通过质量损耗率、相对分子质量测定及形态学观察 (电镜 )等手段分别对PGLA牙周片在体外静态水溶液环境中的降解性能进行研究。结果 :P... 目的 :研究PGLA牙周引导组织再生片体外的降解周期 ,并对影响其降解动力学的各种因素作出评价。方法 :通过质量损耗率、相对分子质量测定及形态学观察 (电镜 )等手段分别对PGLA牙周片在体外静态水溶液环境中的降解性能进行研究。结果 :PGLA膜在体外的降解周期大约为 9~ 10周。材料在模拟体液中的降解速率比在PBS溶液中快 ;降解介质pH值越大 ,材料质量损耗也越快 ;不同尺寸牙周片在各降解周期的质量损耗率均无显著性差异。结论 :PGLA牙周引导组织再生片体外降解主要是化学降解过程 ,通过酯键的水解来进行。降解介质的不同和pH值的改变都会对材料降解动力学产生影响 。 展开更多
关键词 pgla 生物降解 实验研究 牙周引导组织再生术 GTR 手术
下载PDF
PGA,PLA,PGLA碱处理改性及降解性能 被引量:6
4
作者 房美函 王碧峤 +1 位作者 吕志前 张佩华 《东华大学学报(自然科学版)》 CAS CSCD 北大核心 2012年第4期390-395,共6页
采用NaOH对聚乙交酯(polyglycolic acid,PGA)、聚丙交酯(polylactic acid,PLA)及聚乙交酯丙交酯(poly(L-lactide-co-glycolide),PGLA)纤维进行处理.将一定量的试样纤维置于温度为37℃和pH值为7.4的磷酸盐缓冲溶液(PBS)中进行3周的体外... 采用NaOH对聚乙交酯(polyglycolic acid,PGA)、聚丙交酯(polylactic acid,PLA)及聚乙交酯丙交酯(poly(L-lactide-co-glycolide),PGLA)纤维进行处理.将一定量的试样纤维置于温度为37℃和pH值为7.4的磷酸盐缓冲溶液(PBS)中进行3周的体外降解试验.通过测定纤维熔点、接触角、质量损失、强力损失以及纤维表面形态,对PGA,PLA及PGLA纤维碱处理后的热力学降解性能进行研究探讨.研究表明,碱处理后PLA的熔点略有升高,PGA和PGLA的熔点略有降低,3种纤维的水接触角、质量和强力减小;降解过程中PGA和PGLA的质量损失和强力损失显著,而PLA变化很小. 展开更多
关键词 聚乙交酯(PGA) 聚丙交酯(PLA) 聚乙交酯丙交酯(pgla) 碱处理改性 体外降解 性能
下载PDF
应用PGLA膜治疗股骨骨折创伤后膝关节功能障碍临床研究 被引量:2
5
作者 董恒纲 张志宏 +2 位作者 李泽芹 胡泊 穆亮 《天津医科大学学报》 2009年第3期505-507,共3页
目的:评价PGLA(聚乙交酯丙交酯)膜应用于股四头肌成形术中治疗股骨骨折创伤后膝关节功能障碍(PKJD)的临床价值。方法:对6例股骨骨折伴发PKJD患者采用直视下股四头肌成形术联合应用PGLA膜治疗,并评价其临床治疗效果。结果:所有患者随访1... 目的:评价PGLA(聚乙交酯丙交酯)膜应用于股四头肌成形术中治疗股骨骨折创伤后膝关节功能障碍(PKJD)的临床价值。方法:对6例股骨骨折伴发PKJD患者采用直视下股四头肌成形术联合应用PGLA膜治疗,并评价其临床治疗效果。结果:所有患者随访1年,其中4例于术后12周时膝关节活动接近正常,1例6个月时活动接近正常,平均屈膝角度为109.7°,总优良率为83.33%。结论:股四头肌成形术联合应用PGLA膜方法治疗PKJD效果满意,可以解决传统手术必须早期功能锻炼增加患者治疗痛苦的缺点,但由于临床应用例数有限,应进一步观察其疗效。 展开更多
关键词 聚乙交酯丙交酯 创伤后膝关节功能障碍 股四头肌成形术 股骨骨折
下载PDF
Effect of Chitosan Coating on the Properties of Poly(glycolic acid-lactic acid)Thread-Embedding Material 被引量:1
6
作者 徐晓霞 危惠敏 +1 位作者 赵俐 张佩华 《Journal of Donghua University(English Edition)》 EI CAS 2017年第6期722-725,共4页
Poly( glycolic acid-lactic acid)( PGLA) threadembedding material was modified by chitosan coating which could improve the rigidity,hydrophilicity and moisture absorption of the material,and produced better stimulation... Poly( glycolic acid-lactic acid)( PGLA) threadembedding material was modified by chitosan coating which could improve the rigidity,hydrophilicity and moisture absorption of the material,and produced better stimulation effect. Thus,this kind of thread-embedding materials which can be buried into acupuncture points to produce a long-time stimulation is popular in the acupuncture and moxibustion therapies. The variation tendencies of diameter,weight, hydrophilicity, and flexibility of the samples under the change of chitosan coating concentration,coating time and coating times were studied respectively. The results showed that the hydrophilicity,weight,and rigidity after coating rose in a certain range with the increase of coating time,coating times and coating concentration. The coating time had little influence on the diameter of fiber. 展开更多
关键词 poly(glycolic acid-latic acid)(pgla) thread-embedding chitosan coating HYDROPHILICITY FLEXIBILITY RIGIDITY
下载PDF
^(125)I籽源照射对壳聚糖涂层的聚乙丙交酯载体支架体外降解性能的影响 被引量:1
7
作者 陈红红 姜逊 +5 位作者 于雷 郯志清 胡昱兴 王文祖 程文英 邵春林 《辐射研究与辐射工艺学报》 EI CAS CSCD 北大核心 2006年第6期327-332,共6页
研究125I籽源持续低剂量率照射对壳聚糖涂层的聚乙丙交酯(Poly(glycolide-co-lactide),PGLA)薄层支架体外降解性能的影响。在离体条件下,模拟人体环境采用磷酸盐缓冲液(Phosphatebufferedsolution,PBS)作为降解介质,125I籽源单粒表观活... 研究125I籽源持续低剂量率照射对壳聚糖涂层的聚乙丙交酯(Poly(glycolide-co-lactide),PGLA)薄层支架体外降解性能的影响。在离体条件下,模拟人体环境采用磷酸盐缓冲液(Phosphatebufferedsolution,PBS)作为降解介质,125I籽源单粒表观活度为29.6MBq,在薄层支架中5粒125I籽源按一定规律排布。采用质量损耗、弹性回复率测试和扫描电镜观察等方法来评价PGLA薄层支架的体外降解性能。照射后第2周,PGLA薄层支架的质量损耗仅减少了10%左右,弹性保持率维持在60%以上,材料纤维结构保持完好,降解行为不明显;照射第4周时,材料受照剂量最高点处的累积剂量达2.2×103Gy,PGLA薄层支架质量损耗率未超过50%,弹性保持率仍有36%,扫描电镜观察显示,部分材料纤维开始出现裂纹和缝隙,较对照组明显,表明125I籽源持续低剂量率照射4周能使PGLA薄层支架降解速率有所加快,但仍维持了约59%质量和一定的弹性,形态结构保持较好,能有效维持125I籽源的空间分布。 展开更多
关键词 碘-125籽源薄层片 聚乙丙交酯 壳聚糖 生物降解 体外
下载PDF
微波消解-ICP-OES法测定乙交酯-丙交酯类共聚物中的锡
8
作者 陈天怡 白云 +3 位作者 许竞早 范晨亮 彭振磊 张育红 《广州化工》 CAS 2023年第24期60-62,86,共4页
聚乙交酯丙交酯类共聚物(PGLA)聚合工艺中,催化剂多采用锡基催化剂,过量的残留锡(Sn)会对人体造成生物毒害。因此,为有效监控聚合工艺中生产物料的Sn含量,需要建立一套准确并快速的检测方法。通过优化微波消解条件和配方,并配合电感耦... 聚乙交酯丙交酯类共聚物(PGLA)聚合工艺中,催化剂多采用锡基催化剂,过量的残留锡(Sn)会对人体造成生物毒害。因此,为有效监控聚合工艺中生产物料的Sn含量,需要建立一套准确并快速的检测方法。通过优化微波消解条件和配方,并配合电感耦合等离子体发射光谱(ICP-OES)法,建立了可用于测定PGLA产品中Sn含量的分析方法。称取0.10 g PGLA试样,以7 mL 65%~68%硝酸(HNO3)为消解液,消解温度最高为220℃。采用内标法进行定性定量分析,样品重复度好,RSD为3.65%。加标回收率在112%~115%,满足PGLA试样中的Sn含量分析需求,为工艺优化和产品质量控制提供了一种简单、实用的分析方法。 展开更多
关键词 微波消解 ICP-OES 乙交酯-丙交酯类共聚物 锡元素
下载PDF
微创埋线后PGLA线体对正常人体三阴交穴刺激效应的时效性观察 被引量:8
9
作者 聂红昉 侯珣瑞 +5 位作者 梁欣 李丽红 卢雨微 付宗英 李晶 陈静 《针刺研究》 CAS CSCD 北大核心 2019年第2期148-152,共5页
目的:探讨聚乙交酯-丙交酯(PGLA)线体对正常人体经穴刺激效应存在的客观性及时效性,为临床使用PGLA线体行微创埋线及其合理间隔周期提供理论依据。方法:应用医学影像学磁共振成像(MRI)技术采集8例正常人体左侧三阴交穴局部埋线前、后多... 目的:探讨聚乙交酯-丙交酯(PGLA)线体对正常人体经穴刺激效应存在的客观性及时效性,为临床使用PGLA线体行微创埋线及其合理间隔周期提供理论依据。方法:应用医学影像学磁共振成像(MRI)技术采集8例正常人体左侧三阴交穴局部埋线前、后多个时间点T2加权成像(T2WI)压脂及T2图(T2-Mapping)8回波系列图像,所得T2-Mapping 8回波序列图像利用相关软件生成T2-Mapping图后测量埋线局部T2值,分析PGLA线体微创埋线前、后三阴交穴局部T2WI压脂像信号强度及T2值随时间变化的特点。结果:1)埋线前T2WI压脂像上未见异常信号,埋线后各时间点T2WI压脂像上均见到局部高信号,其中埋线后8h、埋线后第3天、埋线后第7天局部信号强度之间无明显差异,埋线后第10天局部信号强度较前减弱,埋线后第14天局部信号强度较前明显减弱。2)与埋线前比较,埋线后各时间点T2值均显著升高(P<0.01);埋线后1周内各时间点T2值之间比较:埋线后8h、埋线后第3天、埋线后第7天之间差异无统计学意义(P>0.05);埋线1周后各时间点T2值之间比较:埋线后第10天与埋线后第7天相比T2值有所下降但差异无统计学意义(P>0.05),埋线后第14天(2周)与埋线后第7天(1周)相比T2值明显下降(P<0.01)。结论:PGLA线体对正常人体经穴局部的刺激效应客观存在且具有一定时效性,其有效刺激时间在14d左右,临床使用同规格型号的PGLA线体施行微创埋线时合理的埋植间隔周期应在14d左右。 展开更多
关键词 微创埋线 pgla线体 刺激效应 时效性 三阴交穴
原文传递