As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal...As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.展开更多
The specific heat capacity of working fluid is an important influence factor on heat transfer characteristic of the pulsating heat pipe(PHP).Due to the relatively large specific heat capacity of micro encapsulated pha...The specific heat capacity of working fluid is an important influence factor on heat transfer characteristic of the pulsating heat pipe(PHP).Due to the relatively large specific heat capacity of micro encapsulated phase change material(MEPCM) suspension,a heat transfer performance experimental facility of the PHP was established.The heat transfer characteristic with MEPCM suspension of different mass concentrations(0.5% and 1.0%) and ultra-pure water were compared experimentally.It was found that when the PHP uses MEPCM suspension as its working fluid,operating stability is impoverished under lower heating power and the operating stability is better under higher heating power.At the inclination angle of 90°,the temperature at heating side decreases compared to ultra-pure water and the temperature at heating side decreases with the raising of MEPCM suspension mass concentration.The heat transfer characteristic of the PHP is positively correlated with the inclination angle and the 90° is optimum.The unfavorable effect of the inclination angle decreases with heating power increasing.When the inclination angle is 90°,the PHP with MEPCM suspension at 1.0% of mass concentration has the lowest thermal transfer resistance and followed by ultra-pure water and MEPCM suspension at 0.5% of mass concentration has the highest thermal transfer resistance.When the inclination angles are 60° and30°,the effect of gravity on the flow direction is reduced to 86.6% and 50% of that on the inclination angle of 90°,respectively,and the promoting effect of gravity on the working fluid is further weakened as the inclination angle further decreases.Due to the high viscosity of MEPCM suspension,the PHP with ultra-pure water has the lowest heat transfer resistance.When the inclination angles is 60°,the thermal resistance with MEPCM suspension at0.5% of the mass concentration is lower than that at 1.0% at the heating power below 230 W.The thermal resistance of MEPCM suspension tends to be similar for heating power of 230-250 W.At the heating power above 270 W,the thermal resistance with MEPCM suspension at 1.0% of the mass concentration is lower than that at 0.5%.展开更多
In this study,a coupling model of fluid-conveying pipes made of functionally graded materials(FGMs)with NiTiNOL-steel(NiTi-ST)for vibration absorption is investigated.The vibration responses of the FGM fluid-conveying...In this study,a coupling model of fluid-conveying pipes made of functionally graded materials(FGMs)with NiTiNOL-steel(NiTi-ST)for vibration absorption is investigated.The vibration responses of the FGM fluid-conveying pipe with NiTi-ST are studied by the Galerkin truncation method(GTM)and harmonic balance method(HBM).The harmonic balance solutions and the numerical results are consistent.Also,the linearized stability of the structure is determined.The effects of the structure parameters on the absorption performance are also studied.The results show that the NiTi-ST is an effective means of vibration absorption.Furthermore,in studying the effect of the NiTi-ST,a closed detached response(CDR)is first observed.It is noteworthy that the CDR may dramatically change the vibration amplitude and that the parameters of the NiTi-ST may determine the emergence or disappearance of the CDR.This vibration absorption device can be extended to offer more general vibration control in engineering applications.展开更多
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant Nos.2021EEEVL0204 and 2018A02。
文摘As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
基金financially supported by National Natural Science Foundation of China (Grant No.52000008)supported by R&D Program of Beijing Municipal Education Commission(Grant No.KM202310016008)+1 种基金Beijing Natural Science Foundation (Grant No.3192042)the Fundamental Research Funds for Beijing University of Civil Engineering and Architecture (Grant No.X20058)。
文摘The specific heat capacity of working fluid is an important influence factor on heat transfer characteristic of the pulsating heat pipe(PHP).Due to the relatively large specific heat capacity of micro encapsulated phase change material(MEPCM) suspension,a heat transfer performance experimental facility of the PHP was established.The heat transfer characteristic with MEPCM suspension of different mass concentrations(0.5% and 1.0%) and ultra-pure water were compared experimentally.It was found that when the PHP uses MEPCM suspension as its working fluid,operating stability is impoverished under lower heating power and the operating stability is better under higher heating power.At the inclination angle of 90°,the temperature at heating side decreases compared to ultra-pure water and the temperature at heating side decreases with the raising of MEPCM suspension mass concentration.The heat transfer characteristic of the PHP is positively correlated with the inclination angle and the 90° is optimum.The unfavorable effect of the inclination angle decreases with heating power increasing.When the inclination angle is 90°,the PHP with MEPCM suspension at 1.0% of mass concentration has the lowest thermal transfer resistance and followed by ultra-pure water and MEPCM suspension at 0.5% of mass concentration has the highest thermal transfer resistance.When the inclination angles are 60° and30°,the effect of gravity on the flow direction is reduced to 86.6% and 50% of that on the inclination angle of 90°,respectively,and the promoting effect of gravity on the working fluid is further weakened as the inclination angle further decreases.Due to the high viscosity of MEPCM suspension,the PHP with ultra-pure water has the lowest heat transfer resistance.When the inclination angles is 60°,the thermal resistance with MEPCM suspension at0.5% of the mass concentration is lower than that at 1.0% at the heating power below 230 W.The thermal resistance of MEPCM suspension tends to be similar for heating power of 230-250 W.At the heating power above 270 W,the thermal resistance with MEPCM suspension at 1.0% of the mass concentration is lower than that at 0.5%.
基金Project supported by the National Natural Science Foundation of China(Nos.12272240 and12022213)。
文摘In this study,a coupling model of fluid-conveying pipes made of functionally graded materials(FGMs)with NiTiNOL-steel(NiTi-ST)for vibration absorption is investigated.The vibration responses of the FGM fluid-conveying pipe with NiTi-ST are studied by the Galerkin truncation method(GTM)and harmonic balance method(HBM).The harmonic balance solutions and the numerical results are consistent.Also,the linearized stability of the structure is determined.The effects of the structure parameters on the absorption performance are also studied.The results show that the NiTi-ST is an effective means of vibration absorption.Furthermore,in studying the effect of the NiTi-ST,a closed detached response(CDR)is first observed.It is noteworthy that the CDR may dramatically change the vibration amplitude and that the parameters of the NiTi-ST may determine the emergence or disappearance of the CDR.This vibration absorption device can be extended to offer more general vibration control in engineering applications.