Effect of preload forces on multidimensional signal dynamic behaviours for battery early safety warning
1
作者 Kuijie Li Jiahua Li +10 位作者 Xinlei Gao Yao Lu Depeng Wang Weixin Zhang Weixiong Wu Xuebing Han Yuan-cheng Cao Languang Lu Jinyu Wen Shijie Cheng Minggao Ouyang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第5期484-498,共15页
Providing early safety warning for batteries in real-world applications is challenging.In this study,comprehensive thermal abuse experiments are conducted to clarify the multidimensional signal evolution of battery fa... Providing early safety warning for batteries in real-world applications is challenging.In this study,comprehensive thermal abuse experiments are conducted to clarify the multidimensional signal evolution of battery failure under various preload forces.The time-sequence relationship among expansion force,voltage,and temperature during thermal abuse under five categorised stages is revealed.Three characteristic peaks are identified for the expansion force,which correspond to venting,internal short-circuiting,and thermal runaway.In particular,an abnormal expansion force signal can be detected at temperatures as low as 42.4°C,followed by battery thermal runaway in approximately 6.5 min.Moreover,reducing the preload force can improve the effectiveness of the early-warning method via the expansion force.Specifically,reducing the preload force from 6000 to 1000 N prolongs the warning time(i.e.,227 to 398 s)before thermal runaway is triggered.Based on the results,a notable expansion force early-warning method is proposed that can successfully enable early safety warning approximately 375 s ahead of battery thermal runaway and effectively prevent failure propagation with module validation.This study provides a practical reference for the development of timely and accurate early-warning strategies as well as guidance for the design of safer battery systems. 展开更多
关键词 Lithium-ion battery Thermal runaway preload force Expansionforce Early warning Multidimensional signal
下载PDF
Research on Optimal Preload Method of Controllable Rolling Bearing Based on Multisensor Fusion
2
作者 Kuosheng Jiang Chengrui Han Yasheng Chang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第6期3329-3352,共24页
Angular contact ball bearings have been widely used in machine tool spindles,and the bearing preload plays an important role in the performance of the spindle.In order to solve the problems of the traditional optimal ... Angular contact ball bearings have been widely used in machine tool spindles,and the bearing preload plays an important role in the performance of the spindle.In order to solve the problems of the traditional optimal preload prediction method limited by actual conditions and uncertainties,a roller bearing preload test method based on the improved D-S evidence theorymulti-sensor fusion method was proposed.First,a novel controllable preload system is proposed and evaluated.Subsequently,multiple sensors are employed to collect data on the bearing parameters during preload application.Finally,a multisensor fusion algorithm is used to make predictions,and a neural network is used to optimize the fitting of the preload data.The limitations of conventional preload testing methods are identified,and the integration of complementary information frommultiple sensors is used to achieve accurate predictions,offering valuable insights into the optimal preload force.Experimental results demonstrate that the multi-sensor fusion approach outperforms traditional methods in accurately measuring the optimal preload for rolling bearings. 展开更多
关键词 MULTI-SENSOR information fusion neural network preload force
下载PDF
Near resonance vibration isolation on a levered-dual response(LEDAR)Coulomb-damped system by differential preloads/offsets in linear springs
3
作者 T.I.TOLUWALOJU C.K.THEIN D.HALIM 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第6期1033-1050,共18页
The levered-dual response(LEDAR)Coulomb-damped system attains near resonant vibration isolation by differential preloads/offsets in linear springs.It takes the advantages of both the preloads/offsets in linear springs... The levered-dual response(LEDAR)Coulomb-damped system attains near resonant vibration isolation by differential preloads/offsets in linear springs.It takes the advantages of both the preloads/offsets in linear springs and the guiderail friction for realizing different levels of vibration isolation.The isolation capacities are investigated on the strategies with both the horizontal and vertical guiderails,with the horizontal rail only,and without guiderails.The compressive preloads generally result in the consumption of most of the initial excitation energy so as to overcome the potential threshold.The isolation onsets at the frequency ratio of 1∓0.095 on the left-hand side(LHS)and the right-hand side(RHS)of the lever are relative to the load plate connector.The observed near resonant isolation thus makes the LEDAR system a candidate for the isolation of the mechanical systems about resonance while opening a path for simultaneous harvesterisolation functions and passive functions at extreme frequencies. 展开更多
关键词 lever ratio Coulomb damping preload tension/compression isolation band/depth offset potential
下载PDF
Strength characteristics of rock anchored by NPR bolt with different preloads
4
作者 SUN Xiao-ming CUI Li +2 位作者 ZHANG Yong WANG Lei JIANG Ming 《Journal of Mountain Science》 SCIE CSCD 2023年第3期834-844,共11页
This study compares the strength characteristics of rocks anchored by NPR bolts and ordinary bolts with varied preloads,based on the mechanical properties of NPR bolts(with a negative Poisson’s ratio).The results sho... This study compares the strength characteristics of rocks anchored by NPR bolts and ordinary bolts with varied preloads,based on the mechanical properties of NPR bolts(with a negative Poisson’s ratio).The results show that the uniaxial compressive stress-strain curve of ordinary anchored rocks exhibits noticeable abrupt changes.After reaching peak strength,the bolt breaks,whereas the stress-strain curve of NPR-anchored rocks is smoother.The NPR bolt enters the stage of continuous resistance after reaching maximal strength and does not break.As the preload increases,the strength of the anchored rock grows linearly.A calculation equation for the strength of the anchored rock is proposed based on the preload.The theoretical equation fits the test results well,and the fitted parameters show that NPR bolts can better increase the strength of the rock.The concept of dynamic toughness UC of anchored rock is proposed to reflect the comprehensive mechanical properties of anchored rock,including strength and plasticity.As the preload increases,the UC of ordinary anchored rock first decreases and then increases,while the UC of the NPR anchored rock does not change significantly with the preload when the strain is small,and the UC increases with the increase of the preload when the strain is large. 展开更多
关键词 NPR bolt Anchored rock Rock bolt Uniaxial compression preload Strength characteristics
下载PDF
Numerical Simulation of Vacuum Preloading for Chemically Conditioned Municipal Sludge
5
作者 Wenwei Li Xinjie Zhan +1 位作者 Baotian Wang Jinyu Zuo 《Journal of Renewable Materials》 SCIE EI 2023年第1期363-378,共16页
Municipal sludge is a sedimentation waste produced during the wastewater process in sewage treatment plants.Among recent studies,pilot and field tests showed that chemical conditioning combined with vacuum preloading ... Municipal sludge is a sedimentation waste produced during the wastewater process in sewage treatment plants.Among recent studies,pilot and field tests showed that chemical conditioning combined with vacuum preloading can effectively treat municipal sludge.To further understand the drainage and consolidation characteristics of the conditioning sludge during vacuum preloading,a large deformation nonlinear numerical simulation model based on the equal strain condition was developed to simulate and analyze the pilot and field tests,whereas the simulation results were not satisfactory.The results of the numerical analysis of the pilot test showed that the predicted consolidation degree was greater than that measured by the field tests,which is attributed to the relatively low permeability layer formed during the preloading process of the prefabricated vertical drain.To better reflect the consolidation process of the conditioned sludge,a simplified analysis method considering the low permeability layer around the prefabricated vertical drain was proposed.The initial permeability coefficient of the low permeability layer is determined via numerical simulations using finite difference method.The predicted settlement curve was in good agreement with the measured results,which indicated that the numerical simulation based on the equal strain condition considering the relatively low permeability layer can better analyze the consolidation process of ferric chloride-conditioning sludge with vacuum preloading. 展开更多
关键词 Sludge treatment large deformation numerical simulation chemical conditioning-combined vacuum preloading low permeability coefficient back analysis
下载PDF
A New Method of Combination of Electroosmosis, Vacuum and Surcharge Preloading for Soft Ground Improvement 被引量:21
6
作者 刘汉龙 崔允亮 +1 位作者 沈扬 丁选明 《China Ocean Engineering》 SCIE EI CSCD 2014年第4期511-528,共18页
As a rapid and effective ground improvement method is urgently required for the booming land reclamation in China's coastal area, this study proposes a new combined method of electroosmosis, vacuum preloading and sur... As a rapid and effective ground improvement method is urgently required for the booming land reclamation in China's coastal area, this study proposes a new combined method of electroosmosis, vacuum preloading and surcharge preloading. A new type of electrical prefabricated vertical drain (ePVD) and a new electroosmotic drainage system are suggested to allow the application of the new method. This combined method is then field-tested and compared with the conventional vacuum combined with surcharge preloading method. The monitoring and foundation test results show that the new method induces a settlement 20% larger than that of the conventional vacuum combined with surcharge preloading method in the same treatment period, and saves approximately half of the treatment time compared with the vacuum combined with surcharge preloading method according to the finite element prediction of the settlement. The proposed method also increases the vane shear strength of the soil significantly. The bearing capacity of the ground improved by use of the new proposed method raises 118%. In comparison, there is only a 75% rise when using the vacuum combined with surcharge preloading method during the same reinforcement period. All results indicate that the proposed combined method is effective and suitable for reinforcing the soft clay ground. Besides, the voltage applied between the anode and cathode increases exponentially versus treatment time when the output current of power supplies is kept constant. Most of the voltage potential in electroosmosis is lost at electrodes, leaving smaller than 50% of the voltage to be effectively transmitted into the soil. 展开更多
关键词 electroosmosis vacuum preloading surcharge preloading soft clay ground electrical resistivity
下载PDF
Preload Analysis of Screw Bolt Joints on the First Wall Graphite Tiles in EAST 被引量:1
7
作者 曹磊 宋云涛 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第9期850-854,共5页
The first wall in the Experimental Advanced Superconducting Tokamak (EAST) used graphite tiles to withstand high thermal energy. The graphite tiles are mounted on the heat sink using screw bolts which have been prel... The first wall in the Experimental Advanced Superconducting Tokamak (EAST) used graphite tiles to withstand high thermal energy. The graphite tiles are mounted on the heat sink using screw bolts which have been preloaded to produce a clamp force. The clamp force is very important to keep the graphite tiles tightly on the surface of the heat sink so that the heat flux crosses this contacting surface in a small thermal resistor. Without the clamp force, the small gap between the graphite tiles and the heat sink will make it impossible for thermal power to be carried away by cooling water. Some bolts may even fall off with the loss of clamp force. From the mathematical models, the loss process of the clamp force has been studied. Research results explain how the different thermal expansions of three members of the screw joint makes the clamp force decrease to zero under temperature rise and external force, and how the stiffness affects the relation between the clamp force and temperature. The research also gives the critical temperature at which the clamp force can remain above zero. Analysis results indicate that the current screw joints are almost destined to lose their clamp force during the running time of EAST, so the bolt joints should be redesigned in order to improve its reliability. 展开更多
关键词 clamp force preload residual preload thermal expansion
下载PDF
Laboratory model study of newly deposited dredger fills using improved multiple-vacuum preloading technique 被引量:9
8
作者 Jingjin Liu Huayang Lei +2 位作者 Gang Zheng Haizuo Zhou Xuelian Zhang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2017年第5期924-935,共12页
Problems continue to be encountered concerning the traditional vacuum preloading method in field during the treatment of newly deposited dredger fills.In this paper,an improved multiple-vacuum preloading method was de... Problems continue to be encountered concerning the traditional vacuum preloading method in field during the treatment of newly deposited dredger fills.In this paper,an improved multiple-vacuum preloading method was developed to consolidate newly dredger fills that are hydraulically placed in seawater for land reclamation in Lingang Industrial Zone of Tianjin City,China.With this multiplevacuum preloading method,the newly deposited dredger fills could be treated effectively by adopting a novel moisture separator and a rapid improvement technique without sand cushion.A series of model tests was conducted in the laboratory for comparing the results from the multiple-vacuum preloading method and the traditional one.Ten piezometers and settlement plates were installed to measure the variations in excess pore water pressures and moisture content,and vane shear strength was measured at different positions.The testing results indicate that water dischargeetime curves obtained by the traditional vacuum preloading method can be divided into three phases:rapid growth phase,slow growth phase,and steady phase.According to the process of fluid flow concentrated along tiny ripples and building of larger channels inside soils during the whole vacuum loading process,the fluctuations of pore water pressure during each loading step are divided into three phases:steady phase,rapid dissipation phase,and slow dissipation phase.An optimal loading pattern which could have a best treatment effect was proposed for calculating the water discharge and pore water pressure of soil using the improved multiple-vacuum preloading method.For the newly deposited dredger fills at Lingang Industrial Zone of Tianjin City,the best loading step was 20 kPa and the loading of 40-50 k Pa produced the highest drainage consolidation.The measured moisture content and vane shear strength were discussed in terms of the effect of reinforcement,both of which indicate that the multiple-vacuum preloading method has a better treatment effect not only in decreasing the moisture content and increasing the bearing capacity,but also in increasing the process uniformity at different depths of foundation. 展开更多
关键词 Model tests Vacuum preloading Ultra-soft soil Dredger fills Cost effectiveness
下载PDF
Improvement of silty clay by vacuum preloading incorporated with electroosmotic method 被引量:4
9
作者 M. Q. Vu 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE 2010年第4期365-372,共8页
A laboratory test was performed to assess the effectiveness of vacuum preloading incorporated with electroosmotic (EOM) treatment on silty clay (combined method) for reclamation projects like new disposal ponds, where... A laboratory test was performed to assess the effectiveness of vacuum preloading incorporated with electroosmotic (EOM) treatment on silty clay (combined method) for reclamation projects like new disposal ponds, where the horizontal electrode configurations beneath the soil layer were possible and the drainage pipes and the prefabricated vertical drains (PVDs) system could be easily installed in advance before the sludge dragged from sea bed or river bed was filled into the site. Three groups of tests were conducted on the silty clay from Qinhuai River in Nanjing, China. The model is able to apply vacuum pressure at the bottom of the soil layer and a direct current electric field simultaneously. It is also possible to measure the pore pressures at different depths of soil column, and the changes in settlement and volume with the elapsed time. In this study, the vacuum preloading method, vacuum preloading applied at the bottom (VAB method), was applied and the cathodes were installed beneath the soil layer. The results obtained indicate substantial reduction in water content, and increases in dry density and undrained shear strength in comparison with those obtained by the vacuum preloading only, particularly at the positions close to the anode. The combined method utilizes the vertical drainage flow created by the electroosmosis integrating the horizontal drainage flow created mostly by the vacuum pressure. The total drainage flow can be calculated as a result of the vertical drainage flow by electroosmosis only and the horizontal drainage flow by the vacuum preloading only. The way of placement of the cathode and the anode in the combined method also overcomes the disadvantage of EOM method itself, i.e. the appearance of cracks between the anode and the surrounding soil. Moreover, it is observed that the vacuum preloading plays a primary role in earlier stage in deduction of free pore water; meanwhile, the electroosmotic method is more efficient in later stage for absorbing water in the diffused double layers of soil. 展开更多
关键词 vacuum preloading VAB method soil improvement CONSOLIDATION pore pressure undrained shear strength dry density electroosmotic method
下载PDF
Efficacy of Different Fluids Preload on Propofol Injection Pain:A Randomized,Controlled,Double-blinded Study 被引量:1
10
作者 袁世荧 罗天元 +1 位作者 刘真 林云 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第2期249-253,共5页
Injection pain of propofol remains a common clinical problem. Previous studies demonstrated that propofol injection pain was alleviated by applying nitroglycerin ointment to the skin of injection site, which inspires ... Injection pain of propofol remains a common clinical problem. Previous studies demonstrated that propofol injection pain was alleviated by applying nitroglycerin ointment to the skin of injection site, which inspires us to test whether venous vasodilation induced by fluid preload could alleviate the pain. Different types or volumes of fluid preload were compared. 200 ASA Ⅰ-Ⅱ adult patients were randomly assigned to five groups of 40 each. A 20 G cannula was established on the dorsum or wrist of the hand. When fluid preload given with Plasma-Lyte A 100 m L(P100 group), 250 m L(P250 group), 500 m L(P500 group), 0.9% saline 500 m L(N500 group) or Gelofusine 500 m L(G500 group) was completed within 30 min, respectively, Propofol(0.5 mg/kg, 1%) was injected at a rate of 0.5 m L/s. A blind investigator assessed the pain using a four-point scale. Incidence of pain in P100, P250, and P500 groups was 87.5%, 57.5% and 35%, respectively(P〈0.05). The median pain intensity score was significantly lower in P500 group than that in P250 and P100 groups(P〈0.05 and P〈0.01, respectively). Comparison of the effect of different types of solution preload indicated that the highest incidence of pain was in N500 group(62.5%)(N500 vs. P500, P=0.014; N500 vs. G500, P=0.007). The median pain intensity score in N500 group was higher than that in P500 group(P〈0.05) and G500 group(P〈0.05). There was no significant difference between P500 and G500 groups. It is suggested that Plasma-Lyte A or Gelofusine preload with 500 m L before propofol injection is effective in alleviating propofol-induced pain. 展开更多
关键词 PROPOFOL injection pain Plasma-Lyte A fluid preload GELOFUSINE
下载PDF
Rigorous Axially Symmetric Consolidation Solution of Vacuum Combined Linear Loading Surcharge Preloading 被引量:1
11
作者 彭劼 蒋锐 田艳梅 《Journal of Donghua University(English Edition)》 EI CAS 2018年第4期279-284,共6页
Vacuum combined surcharge preloading is an effective method which has been used in ground treatment. This study presents the analytical solution of vertical drains with vacuum combined surcharge preloading. The surcha... Vacuum combined surcharge preloading is an effective method which has been used in ground treatment. This study presents the analytical solution of vertical drains with vacuum combined surcharge preloading. The surcharge was considered to be time-dependent preloading due to its reflection of the real situation.Moreover,the free strain,instead of equal strain hypothesis of the surface,was adopted for the mathematical rigor. Both vertical and horizontal drainages,along with the well resistance were considered.Besides,the time-dependent surcharge preloading was resolved with the impulse theorem which has been presented in the study,and the solutions for pore water pressure and degree of consolidation were derived by applying the approach of separation of variables.Furthermore,the solution is compared with previous solutions and numerical solutions,and the results verify the correctness of the proposed model. 展开更多
关键词 VACUUM COMBINED SURCHARGE preloadING time-dependentsurcharge CONSOLIDATION analytical SOLUTION
下载PDF
Analysis of ground deformation development and settlement prediction by air-boosted vacuum preloading 被引量:1
12
作者 Shuangxi Feng Huayang Lei Cheng Lin 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第1期272-288,共17页
Vacuum preloading has been widely used to improve soft soils in coastal areas of China.An increasing amount of evidence from field operations has shown that conventional vacuum preloading is prone to clogging in prefa... Vacuum preloading has been widely used to improve soft soils in coastal areas of China.An increasing amount of evidence from field operations has shown that conventional vacuum preloading is prone to clogging in prefabricated vertical drains(PVDs)and demands a large volume of sand fills.In recent years,air-boosted vacuum preloading has been developed to overcome these limitations;however,this method still requires more data to verify its performance.In this study,a field test for air-boosted vacuum preloading was conducted,and a large-strain two-dimensional(2D)finite element(FE)model was developed and validated against the field test data.Then,a series of FE parametric analyses was performed to assess key factors,i.e.the air injection pressure,the injection spacing,and the characteristics of cyclic injection,which affect the performance of the air-boosted vacuum preloading.The results showed that the ground settlement and lateral displacement of the soils increased due to an increase in the injection pressure,a decrease in the injection spacing,or increases in the number and duration of the injection cycles.Based on the parametric analyses,an empirical formula for ground settlement prediction was proposed and compared with a case history reported in the literature,showing good agreement. 展开更多
关键词 Air-boosted vacuum preloading Field test Numerical modeling SETTLEMENT Soft soils Ground improvement
下载PDF
Effect of a preload force on anchor system frequency 被引量:2
13
作者 Lu Aihong Xu Jinhai Liu Haishun 《International Journal of Mining Science and Technology》 SCIE EI 2013年第1期135-138,共4页
The interrelationship between preload forces and natural frequencies of anchors was obtained from the structure of an anchor and its mechanical characteristics. We established a numerical model for the dynamic analysi... The interrelationship between preload forces and natural frequencies of anchors was obtained from the structure of an anchor and its mechanical characteristics. We established a numerical model for the dynamic analysis of a bolt support system taking into consideration the working surroundings of the anchor. The natural frequency distribution of the system under various preload forces of the anchor was analyzed with ANSYS. Our results show that each order of the system frequency varied with an increase in preload forces. A single order frequency decreased with an increase in the preload force. A preload force affected low-order frequencies more than high-order frequencies. We obtained a functional relationship by fitting preload forces and fundamental frequencies, which was in agreement with our theretical considerations. This study provides theoretical support for the detection of preload forces. 展开更多
关键词 Frequency preload force Anchor detection Numerical simulation
下载PDF
DYNAMIC BUCKLING OF STATICALLY PRELOADED RING-STIFFENED CYLINDRICAL SHELLS UNDER AXIAL FLUID-SOLID IMPACT LOADING 被引量:1
14
作者 Jiang Songqing Li Yongchi +1 位作者 Hu Xiuzhang Zheng Jijia 《Acta Mechanica Solida Sinica》 SCIE EI 2000年第3期189-197,共9页
The Initial Imperfection Amplified Criterion is applied toinvestigate the geometric nonlinear dynamic buckling of staticallypreloaded ring-stiffened cylindrical shells under axial fluid-solidimpact. Tak- ing account o... The Initial Imperfection Amplified Criterion is applied toinvestigate the geometric nonlinear dynamic buckling of staticallypreloaded ring-stiffened cylindrical shells under axial fluid-solidimpact. Tak- ing account of the effects of large deformation andinitial geometric imperfection, the governing equations are obtainedby the Galerkin method and solved by the Runge-Kutta method. Theeffects of static preloading (uniform external radial pressure) onthe buckling features and the load-carrying ability of ring-stiffenedcy- lindrical shells against axial impact are discussed. 展开更多
关键词 statically preloaded ring-stiffened cylindrical shells axial fluid-solidimpact loading
下载PDF
Simulation Vacuum Preloading Method by Tri-Axial Apparatus 被引量:1
15
作者 Ngo Trung Duong Wanchai Teparaksa Hiroyuki Tanaka 《International Journal of Geosciences》 2012年第1期211-221,共11页
It is very important to control any risk of instability of embankment during vacuum construction, the simulation vacuum preloading method using tri-axial apparatus is proposed to predict the behavior of soft soil impr... It is very important to control any risk of instability of embankment during vacuum construction, the simulation vacuum preloading method using tri-axial apparatus is proposed to predict the behavior of soft soil improvement in the laboratory, as well as to make this method become familiar and easier in the future. The tri-axial apparatus is used instead of the large-scale one, which has been performed by Bergado (1998) and Indaratna (2008). The tri-axial test on small size specimen can be carried out in one week compared to the large-scale apparatus takes one month for big specimen. In addition, the lateral deformation as well as the shear strength increase with time can determine accurately. 展开更多
关键词 Soft SOIL SOIL Improvement VACUUM preloadING Degree of CONSOLIDATION
下载PDF
Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial 被引量:1
16
作者 Byunghoon Chung Hun Lee +3 位作者 Moonjung Choi Kyoung Yul Seo Eung Kweon Kim Tae-im Kim 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第1期6-11,共6页
AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational ca... AIM: To compare characteristics of preloaded and nonpreloaded intraocular lens(IOL) delivery systems during IOL delivery procedures. METHODS: Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including i Sert250 NC60(NC60), En Vista MX60(MX60), Acry Sof IQ SN60 WF(SN60 WF), TECNIS ZCB00(ZCB00), and TECNIS PCB00(PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via nonpreloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device(OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodiumstained OVD. RESULTS: The average time for IOL implantation was 22.0 s for NC60, 43.2 s for MX60, 32.3 s for SN60 WF, 41.4 s for ZCB00, and 14.6 s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60 WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION: IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems. 展开更多
关键词 preloaded intraocular lens delivery system non-preloaded intraocular lens delivery system intraocular lens delivery time ophthalmic viscosurgical device
下载PDF
Numerical study of rheologic and soil damage for ground improvement by vacuum preloading
17
作者 吴跃东 郑世华 《Journal of Central South University》 SCIE EI CAS 2008年第S2期161-167,共7页
Based on the characteristics and reinforcement mechanism of vacuum preloading applied in high way soft foundation, the theoretical calculation method of vacuum preloading was presented. According to the equivalent met... Based on the characteristics and reinforcement mechanism of vacuum preloading applied in high way soft foundation, the theoretical calculation method of vacuum preloading was presented. According to the equivalent method derived from sand drain foundation subjected to plane and axisymmetric conditions, the three dimensional problem was transformed into plane strain problem. The modified Komala-Huang model was used to model the rheological behavior and the damage theory was also introduced to consider the effect of damage caused by construction disturbance. Numerical simulations were carried out for a high way test section. The results show that simulations of the viscoelastic-plastic-damage model are in good agreement with the field measurements. It suggests that the calculation method, simplified load and boundary condition used in this study are reasonable. 展开更多
关键词 VACUUM preloadING PLANE stain FEM RHEOLOGY DAMAGE consolidate
下载PDF
Preload-responsive adhesion of microfibre arrays to rough surfaces
18
作者 Yuchen ZHANG Linghui HE 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2017年第2期155-160,共6页
Adhesion of bio-inspired microfibre arrays to a rough surface is studied theoretically. The array consists of vertical elastic rods fixed on a rigid backing layer, and the surface is modeled by rigid steps with a norm... Adhesion of bio-inspired microfibre arrays to a rough surface is studied theoretically. The array consists of vertical elastic rods fixed on a rigid backing layer, and the surface is modeled by rigid steps with a normally distributed height. Analytical expressions are obtained for the adhesion forces in both the approach and retraction processes. It is shown that, with the increasing preload, the pull-off force increases at first and then attains a plateau value. The results agree with the previous experiments and are expected helpful in adhesion control of the array in practical applications. 展开更多
关键词 fibrillar adhesion rough surface preload pull-off force
下载PDF
Nitroglycerin reduces augmentation index and central blood pressure independent of effects on cardiac preload
19
作者 Mike Saddon Karen McNeil Philip Chowienczyk 《Journal of Pharmaceutical Analysis》 SCIE CAS 2009年第2期114-119,共6页
Objective To determine whether reduction in central pressure augmentation and central systolic blood pressure by nitroglycerine (NTG) results from effects on pre-load or is due to arterial dilation. Methods We compare... Objective To determine whether reduction in central pressure augmentation and central systolic blood pressure by nitroglycerine (NTG) results from effects on pre-load or is due to arterial dilation. Methods We compared effects of NTG with those of lower body negative pressure (LBNP). Hemodynamic measurements were made at rest,during LBNP (10,20 and 30 mmHg,each for 15 min) and after NTG (10,30 and 100 μg/min,each dose for 15 min) in ten healthy volunteers. Cardiac pre-load,stroke volume and cardiac output were assessed by echocardiography. Central pressure augmentation and central systolic pressure were obtained by radial tonometry using a transfer function. Results LBNP (20 mmHg) and NTG (30 μg/min) reduced pre-load (as measured by the peak velocity of the S wave in the superior vena cava) to a similar degree [by (26.8±3.8)% and (23.9±3.4)%,respectively]. Compared to LBNP,NTG reduced systemic vascular resistance [by (32.9±7.5)%,P<0.01],decreased peripheral and central pressure augmentation [by (20.8±3.4)% units and (12.9±2.9)% units,respectively,each P<0.01]. Conclusion These results suggest that a reduction in pre-load does not explain reduction in pressure augmentation and central systolic blood pressure by NTG and that these effects are mediated through arterial dilation. 展开更多
关键词 augmentation index central blood pressure NITROGLYCERINE cardiac preload lower body negative pressure
下载PDF
Competitive Failure of Bolt Loosening and Fatigue under Different Preloads
20
作者 Guangwu Yang Long Yang +2 位作者 Jingsong Chen Shoune Xiao Shilin Jiang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2021年第6期417-427,共11页
Existing research on the competitive failure relationship,failure mechanism,and influencing factors of bolt loosening and fatigue under different preloads is insufficient.This study analyzes the competitive failure re... Existing research on the competitive failure relationship,failure mechanism,and influencing factors of bolt loosening and fatigue under different preloads is insufficient.This study analyzes the competitive failure relationship between bolt loosening and fatigue under composite excitation through competitive failure tests of bolt loosening and fatigue under different preloads.The results indicated that the failure mode of the bolt is only related to the load ratio(R)and is unrelated to the initial preload and excitation amplitude,which only determine the failure life of the bolt.The small axial loads of composite excitation can restrain bolt failure,and the significant degree of this restraining effect is differ-ent for different preloads.Subsequently,a fracture analysis of the bolt was performed to verify the competitive failure relationship of the bolt from a microscopic perspective,and the competitive failure mechanism of the bolt was deter-mined.Based on the findings,we propose a calculation equation for the optimal preload of 8.8 grade high-strength bolts that can serve as a reference for engineering applications. 展开更多
关键词 BOLT preload LOOSENING FATIGUE Competitive failure