A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, wmcn has a sensluve area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce ...A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, wmcn has a sensluve area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a 55Fe X-ray source and a 200 MeV/u ^12C beam from CSRm. A position resdution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.展开更多
基金Supported by National Natural Science Foundation of China(11079044)
文摘A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, wmcn has a sensluve area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a 55Fe X-ray source and a 200 MeV/u ^12C beam from CSRm. A position resdution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.