Online Capacitor Voltage Transformer Measurement Error State Evaluation Method Based on In-Phase Relationship and Abnormal Point Detection
1
作者 Yongqi Liu Wei Shi +2 位作者 Jiusong Hu Yantao Zhao Pang Wang 《Smart Grid and Renewable Energy》 2024年第1期34-48,共15页
The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the... The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the power grid. This paper advances an online CVT error state evaluation method, anchored in the in-phase relationship and outlier detection. Initially, this method leverages the in-phase relationship to obviate the influence of primary side fluctuations in the grid on assessment accuracy. Subsequently, Principal Component Analysis (PCA) is employed to meticulously disentangle the error change information inherent in the CVT from the measured values and to compute statistics that delineate the error state. Finally, the Local Outlier Factor (LOF) is deployed to discern outliers in the statistics, with thresholds serving to appraise the CVT error state. Experimental results incontrovertibly demonstrate the efficacy of this method, showcasing its prowess in effecting online tracking of CVT error changes and conducting error state assessments. The discernible enhancements in reliability, accuracy, and sensitivity are manifest, with the assessment accuracy reaching an exemplary 0.01%. 展开更多
关键词 Capacitor voltage transformer Measurement Error Online Monitoring Principal Component Analysis Local Outlier Factor
下载PDF
Over Voltage Fault due to Disconnection of Consumer’s Transformer Neutral Wire
2
作者 Erdene Adiyasuren Enkh-Od Erdene +1 位作者 Sergelen Byambaa Shagdarsuren Gantumur 《Journal of Energy and Power Engineering》 2023年第1期11-14,共4页
Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected fr... Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected from the neutral of power supply source,then there will be some trouble and failure occurred.The current in the neutral wire drops down to zero when the neutral wire is cut off and the phase currents of all three-phase equal to each other since there was no return wire.The currents are equal but the voltages at the phase consumers are different.Especially for residential single-phase consumers,the voltage at the consumers of the phase varies differently for three phase systems when the neutral wire was disconnected at consumer side and even the voltage at the consumers one or two of those three phases becomes over nominal voltage or reaches nearly line voltage.In this case,the electronic appliances in that phase will be fed by high voltage than the rated value and they can be broken down.In the power system of UB(Ulaanbaatar)city,there are some occasional such kind of failures every year.Obviously,many electronic appliances were broken down due to high voltage and the electricity utility companies respond for service charge of damaged parts. 展开更多
关键词 Neutral connection and neutral wire phase and line voltage single-phase residential consumer transformer neutral cut off asymmetric load current protective earth
下载PDF
Optical fiber-based power and data delivery system for high voltage electronic current transformer
3
作者 邱红辉 段雄英 邹积岩 《Journal of Shanghai University(English Edition)》 CAS 2008年第3期268-273,共6页
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi... This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request. 展开更多
关键词 high voltage electronic current transformer (ECT) optical power supply delivery system photovoltaic powerconverters supervisory functions
下载PDF
Optimal PV Allocation&Minimal tap-Changing Transformers Achieving Best Distribution Voltage Profile&Minimum Losses in active distribution networks
4
作者 Hisham M.Soliman Abdelsalam Elhaffar Mohammed Albadi 《Electrical Science & Engineering》 2019年第2期32-36,共5页
In distribution systems,voltage levels of the various buses should be maintained within the permissible limits for satisfactory operation of all electrical installations and equipment.The task of voltage control is cl... In distribution systems,voltage levels of the various buses should be maintained within the permissible limits for satisfactory operation of all electrical installations and equipment.The task of voltage control is closely associated with fluctuating load conditions and corresponding requirements of reactive power compensation.The problem of load bus voltage optimization in distribution systems that have distributed generation(DG)has recently become an issue.In Oman,the distribution code limits the load bus voltage variations within±6%of the nominal value.Several voltage control methods are employed in active distribution systems with a high share of photovoltaic systems(PV)to keep the voltage levels within the desirable limits.In addition to the constraint of targeting the best voltage profile,another constraint has to be achieved which is the minimum loss in the distribution network.An optimised solution for voltage of load busses with on-load tap-changing(OLTC)tarnsformers and PV sources is presented in this paper.This study addresses the problem of optimizing the injected power from PV systems associated with the facilities of tap-changing transformers,as it is an important means of controlling voltage throughout the system.To avoid violating tap-changing constraints,a method is depicted for determining the minimal changes in transformer taps to control voltage levels with distributed PV sources.The taps of a range+5 to-15%,can be achieved by tap-changing transformers.The OLTC operation was designed to keep the secondary bus within the voltage standard for MV networks. 展开更多
关键词 Distributed generation voltage control Tap-changing transformerS Non-linear constrained optimization ACTIVE distribution networks
下载PDF
Impedance Model for Instability Analysis of LCC-HVDCs Considering Transformer Saturation
5
作者 Qin Jiang Ruiting Xu +4 位作者 Baohong Li Xiang Chen Yue Yin Tianqi Liu Frede Blaabjerg 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1309-1319,共11页
In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the trans-former saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power ... In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the trans-former saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power system.How-ever,the nonlinear characteristics of the power grids introduced by the transformer saturation considerably limit the application of the conventional analysis methods.To address the issue,this paper derives a linear model for the transformer saturation caused by the DC current due to the converter modulation.Af-terwards,the nonlinear characteristics of power grids with the transformer saturation is described by a complex valued imped-ance matrix.Based on the derived impedance matrix,the sys-tem harmonic stability is analyzed and the mechanism of the transformer saturation induced harmonic instability is revealed.Finally,the sensitivity analysis is conducted to find the key fac-tors that influence the system core saturation instability.The proposed impedance model is verified by the electromagnetic transient simulation,and the simulation results corroborate the effectiveness of the proposed impedance model.Index TermsLine commutated converter based high voltage direct current(LCC-HVDC),transformer saturation,harmonic instability,impedance model. 展开更多
关键词 Line commutated converter based high voltage direct current(LCC-HVDC) transformer saturation harmonic instability impedance model
原文传递
Smart Transformer-based Medium Voltage Grid Support by Means of Active Power Control 被引量:5
6
作者 Stefano Giacomuzzi Marius Langwasser +2 位作者 Giovanni De Carne Giuseppe Buja Marco Liserre 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期285-294,共10页
In the last decades the voltage regulation has been challenged by the increase of power variability in the electric grid,due to the spread of non-dispatchable generation sources.This paper introduces a Smart Transform... In the last decades the voltage regulation has been challenged by the increase of power variability in the electric grid,due to the spread of non-dispatchable generation sources.This paper introduces a Smart Transformer(ST)-based Medium Voltage(MV)grid support by means of active power control in the ST-fed Low Voltage(LV)grid.The aim of the proposed strategy is to improve the voltage profile in MV grids before the operation of On-Load Tap Changer in the primary substation transformer,which needs tens of seconds.This is realized through reactive power injection by the AC/DC MV converter and simultaneous decrease of the active power consumption of voltage-dependent loads in ST-fed LV grid,controlling the ST output voltage.The last feature has two main effects:the first is to reduce the active power withdrawn from MV grid,and consequently the MV voltage drop caused by the active current component.At the same time,higher reactive power injection capability in the MV converter is unlocked,due to the lower active power demand.As result,the ST increases the voltage support in MV grid.The analysis and simulation results carried out in this paper show improvements compared to similar solutions,i.e.the only reactive power compensation.The impact of the proposed solution has been finally evaluated under different voltage-dependence of the loads in the LV grid. 展开更多
关键词 Smart transformer Solid State transformers Load Control voltage Support
下载PDF
Development of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer 被引量:1
7
作者 Ahmad El Shafei Saban Ozdemir +2 位作者 Necmi Altin Garry Jean-Pierre Adel Nasiri 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期95-104,共10页
The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficie... The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems.The objective of this paper is to present the design,implementation,and testing of a compact multi-port solid-state transformer for microgrid integration applications.The proposed system has a four-port transformer and four converters connected to the ports.The transformer has four windings integrated on a single common core.Thus,it can integrate different renewable energy resources and energy storage systems.Each port has a rated power of 25 kW,and the switching frequency is pushed to 50 k Hz.The ports are chosen to represent a realistic industrial microgrid model consisting of grid,energy storage system,photovoltaic system,and load.The grid port is designed to operate at 4.16 k VAC corresponding to 7.2 kV DC bus voltage,while the other three ports operate at 500 VDC.Moreover,the grid,energy storage and photovoltaic ports are active ports with dual active bridge topologies,while the load port is a passive port with full bridge rectifier one.The proposed design is first validated with simulation results,and then the proposed transformer is implemented and tested.Experimental results show that the designed system is suitable for 4.16 k VAC medium voltage grid integration. 展开更多
关键词 CO-SIMULATION high frequency high power medium voltage MICROGRID MULTI-PORT solid state transformer
下载PDF
Analysis of output voltage on a planar insulating core transformer 被引量:3
8
作者 KANG Cheng LIU Yonghao LI Deming 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第1期15-18,共4页
Output voltage is an important performance characteristic of planar insulating core transformer (PICT).In PICT magnetic cores are insulated from their neighboring magnetic cores by solid insulating materials.Solid ins... Output voltage is an important performance characteristic of planar insulating core transformer (PICT).In PICT magnetic cores are insulated from their neighboring magnetic cores by solid insulating materials.Solid insulating materials can increase leakage flux.This results in a low generated voltage in secondary coils,especially on the upper stages.Connecting flux compensation capacitors to secondary coils can compensate the flux loss.Design equations to calculate the flux compensation capacitors value and relevant simulation by CST and Protel software were presented.Simulation results of an actual PICT showed that output voltage increased by 19% after being connected to flux compensation capacitors and the voltage on every stage was equally distributed.Results of simulation were consistent with the following experimental test,which revealed that flux compensation capacitors were effective. 展开更多
关键词 固体绝缘材料 输出电压 变压器 平面 PROTEL软件 补偿电容器 磁通补偿 二次线圈
下载PDF
Transformation optics for efficient calculation of transmembrane voltage induced on cells
9
作者 廖胤鸿 朱铧丞 +1 位作者 唐正明 黄卡玛 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期31-35,共5页
We present a novel efficient approach in calculating induced transmembrane voltage(ITV) on cells based on transformation optics. As cell membrane is much thinner than the dimension of a typical cell, discretizing th... We present a novel efficient approach in calculating induced transmembrane voltage(ITV) on cells based on transformation optics. As cell membrane is much thinner than the dimension of a typical cell, discretizing the membrane needs numerous meshes. Using an anisotropic medium based on transformation optics, the thickness of the membrane can be exaggerated by at least one order, which eliminates rigorous mesh refinement and reduces unknowns greatly. The accuracy and efficiency of the proposed method are verified by a cylindrical cell model. Moreover, the influence on ITV with bound water(BW) layers is also studied. The results show that when cells are exposed to nanosecond electric field, BW layers should be rigorously considered in calculating ITV. 展开更多
关键词 efficient calculation transmembrane voltage transformation optics anisotropic medium mem- brane bound water layer
下载PDF
Application of Voltage Response Method to Condition Assessment of Power Transformer 被引量:2
10
作者 ZHANG Tao CAI Jin-ding ZHANG Kong-lin 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2674-2680,共7页
Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and re... Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation. 展开更多
关键词 电压响应方法 电力变压器 评估 RVM 起始斜率 故障诊断
下载PDF
Analysis on the Influence Factors of Capacitor Voltage Transformer Dielectric Loss Measurement
11
作者 Yongdong Li Qing-da Meng +3 位作者 Po Yang Zheyuan Zhao Wei Zhang Zhuo Pan 《Energy and Power Engineering》 2013年第4期1240-1242,共3页
Capacitor voltage transformer (CVT), which is with simple structure, convenient maintenance, functional diversity and high impact pressure strength, is widely used. And its capacitance and dielectric loss Angle measur... Capacitor voltage transformer (CVT), which is with simple structure, convenient maintenance, functional diversity and high impact pressure strength, is widely used. And its capacitance and dielectric loss Angle measurement is an important test on testing the insulation of the equipment. This paper is mainly to introduce and discuss one of the CVT test methods——the “self excitation method”, combined with the actual situation encountered in the work, sums up and expounds the maintenance of CVT and preventive test of influence factors. 展开更多
关键词 Capacitive voltage transformer DIELECTRIC LOSS the Influencing FACTORS
下载PDF
Voltage Profile Enhancement and Power Loss Reduction with Economic Feasibility Using Small Capacity Distribution Transformers
12
作者 Rasool M.Imran Mohammed R.Saeed +5 位作者 Mohammed Amer Mohammed Osama A.Suhry Ihsan H.Abdulqadder Hasan Wahhab Salih Mohammed R.Almallah Firas M.F.Flaih 《Energy Engineering》 EI 2022年第6期2447-2467,共21页
Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop f... Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop for different types of consumers.Reducing losses and improving voltage profiles in rural distribution networks are significant challenges for electricity distribution companies.However different solutions were proposed in the literature to overcome these challenges,most of them face difficulties when applied in the conventional distribution network.To address the above issues,an applicable solution is proposed in this paper by installing a number of small-capacity distribution transformers instead of every single large-capacity transformer in rural areas.The proposed approach is implemented in the branch network of Al-Hoqool village,which belongs to the Nineveh distribution network.The network has been inspected on-site,drawn,and analyzed using the electrical systems analysis program(ETAP).The analysis showed that using the single-phase pole-mounted transformers can improve the voltage in the network’s end by 29%and enhance the voltage profile for all consumers.The analysis has also demonstrated that the modification can reduce the total power losses by 78%compared to the existing network.Concerning the economic aspect,the payback period for the proposed network is assigned to be 20 months. 展开更多
关键词 Single-phase pole-mounted transformer three-phase transformer power losses voltage profile distribution networks
下载PDF
Research on resonance fault caused by dc magnetic biasing in ultra high voltage transformer with parallel static var compensator
13
作者 Yang Nan Zhu Zimin Yuan Tiejiang 《Journal of Southeast University(English Edition)》 EI CAS 2020年第3期301-312,共12页
For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing... For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid. 展开更多
关键词 static var compensator ultra-high voltage transformer magnetic biasing resonance fault
下载PDF
Analytical Solution for Evaluation of Voltage Surge Distribution along Transformer Windings through the Method of Residues
14
作者 Sergio H. L. Cabral Savio Leandro Bertoli 《Journal of Energy and Power Engineering》 2014年第6期1099-1103,共5页
Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation conce... Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation concerns. In consequence, studies based on analytical approach to basic studies of correlated problems have become even more important because they form the very basis of knowledge that is necessary to every transformer designer in view of taking all the advantages of computational analyses. On the other hand, one of the most important basic studies consists in the evaluation of voltage surge distribution along transformer windings for which the method of separation of variables has been extensively used thanks to some simplifying assumptions. With this aim, authors have developed and previously published works that show the applicability of an alternative and useful analytical method that is the method of the residues, which requires no simplification to be assumed. In this work, another important step is taken towards proofing the total applicability of this promising method that is through a practical problem. A comparison to the numerical method TLM (transmission line method) is also performed and concordance with TLM and experimental data confirms the proposal of the method of residues can be also applicable to several others problems of electromagnetism. 展开更多
关键词 transformer winding method of residues electrical transient voltage surge.
下载PDF
Establishment of continuous cooling transformation diagrams of aluminum alloys using in situ voltage measurement 被引量:1
15
作者 李红英 宾杰 +1 位作者 赵延阔 王晓峰 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第9期1944-1949,共6页
An effective method was proposed to establish the continuous cooling transformation(CCT) diagrams of aluminum alloys using in situ voltage measurement.The voltage change of samples with predefined dimension was reco... An effective method was proposed to establish the continuous cooling transformation(CCT) diagrams of aluminum alloys using in situ voltage measurement.The voltage change of samples with predefined dimension was recorded under the constant current state during continuous cooling.Solutionizing time,together with starting and finishing temperatures of phase transformation of the alloy can be obtained from relationships of voltage vs time and temperature.A critical cooling rate without detectable phase transition during continuous cooling can be determined.Continuous cooling transformation diagrams of tested samples can be established conveniently based on these results.Microstructure observation and differential scanning calorimetry(DSC) testing were applied to verify the reliability of continuous cooling transformation diagram. 展开更多
关键词 aluminum alloys in situ voltage measurement phase transformation CCT diagram MICROSTRUCTURE
下载PDF
配电网低频非线性振荡引发PT保险熔断的机理及抑制措施 被引量:1
16
作者 魏菊芳 姚创 +4 位作者 崔涵 于顺智 何潇 陈小月 郑智慧 《电力科学与技术学报》 CAS CSCD 北大核心 2024年第1期155-163,共9页
电缆的接入使配电网中性点不接地系统对地电容电流增大,产生由单相接地故障引发的低频非线性振荡,导致电磁式电压互感器(potential transformer,PT)保险熔断,严重影响系统安全运行。首先,分析了低频非线性振荡导致PT保险熔断的原理,并基... 电缆的接入使配电网中性点不接地系统对地电容电流增大,产生由单相接地故障引发的低频非线性振荡,导致电磁式电压互感器(potential transformer,PT)保险熔断,严重影响系统安全运行。首先,分析了低频非线性振荡导致PT保险熔断的原理,并基于ATP⁃EMTP平台对10 kV中性点不接地系统进行了仿真计算,计算表明,低频非线性振荡最大过电压小于2.0 p.u.,故障0.1 s后电流接近熔断器熔断电流,系统对地电容增大、零序电阻减小,保险熔断风险增大;然后,仿真验证了4PT接线和PT高压侧中性点串接压敏电阻抑制措施的有效性,并计算了零序电压测量误差;最后,建立10 kV系统的低频非线性振荡试验平台,验证仿真的有效性,对提高配电网PT运行安全性具有参考价值。 展开更多
关键词 电磁式电压互感器 低频非线性振荡 保险熔断 抑制措施
下载PDF
Equivalent Doping Transformation Method for Predicting Breakdown Voltage and Peak Field at Breakdown of Epitaxial-Diffused Punch-Through Junction
17
作者 何进 张兴 +1 位作者 黄如 王阳元 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2001年第3期256-260,共5页
Based on a new semi empirical analytical method, namely equivalent doping transformation, the breakdown voltage and the peak field of the epitaxial diffused punch through junction have been obtained. The basic prin... Based on a new semi empirical analytical method, namely equivalent doping transformation, the breakdown voltage and the peak field of the epitaxial diffused punch through junction have been obtained. The basic principle of this method is introduced and a set of breakdown voltage and peak field plots are provided for the optimum design of the low voltage power devices. It shows that the analytical results coincide with the previous numerical simulation well. 展开更多
关键词 epitaxial diffused punch through junction breakdown voltage peak field equivalent doping transformation
下载PDF
Prediction of Breakdown Voltage of Asymmetric Linearly-Graded Junction by Equivalent Doping Profile Transformation Method
18
作者 何进 张兴 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2002年第2期183-187,共5页
This report describes an equivalent doping profile transformation method with which the avalanche breakdown voltage of the asymmetric linearly graded junction was analytically predicted.The maximum breakdown voltage a... This report describes an equivalent doping profile transformation method with which the avalanche breakdown voltage of the asymmetric linearly graded junction was analytically predicted.The maximum breakdown voltage and the different depletion layer extension on the diffused side and substrate side are demonstrated in the report.The report shows the equivalent doping profile method is valid to predict the breakdown voltage of the complex P N junction.The analytical results agree with the experimental breakdown voltage in comparison with the abrupt junction and symmetric linearly graded junction approximations. 展开更多
关键词 P N junction asymmetric linearly graded junction breakdown voltage depletion layer extension equivalent doping profile transformation
下载PDF
Identification of voltage sag source location using S and TT transformed disturbance power 被引量:1
19
作者 Hussain Shareef Azah Mohamed Ahmad Asrul Ibrahim 《Journal of Central South University》 SCIE EI CAS 2013年第1期83-97,共15页
An alternative method was introduced for voltage sag source location based on S and TT transformed disturbance powers. It is done to avoid the wrong and inconclusive detection of conventional disturbance power method ... An alternative method was introduced for voltage sag source location based on S and TT transformed disturbance powers. It is done to avoid the wrong and inconclusive detection of conventional disturbance power method proposed in the literature. Unlike in the case of the traditional method, the proposed method first transforms the recorded voltage and current during the sag event to some special features before calculating the new version of disturbance powers. The effectiveness of the proposed method has been verified through simulation and actual data from an industrial power system. The results show that the presented method can correctly detect the location of voltage sag source. 展开更多
关键词 power quality voltage sag S transform TT transform signal processing
下载PDF
10 kV配网电压互感器PT铁磁谐振异常仿真模型研究 被引量:1
20
作者 卢晓宇 高岳达 赵哲 《粘接》 CAS 2024年第1期185-188,共4页
为了研究PT铁磁谐振所带来的影响,分析其影响因素,以10 kV低压配电网形成PT铁磁谐振过电压的基本原理为基础,利用EMTP-ATP计算机软件,构建中性点不接地系统仿真模型。以电压互感器的励磁特性、三相参数不平衡2大因素对铁磁谐振影响为例... 为了研究PT铁磁谐振所带来的影响,分析其影响因素,以10 kV低压配电网形成PT铁磁谐振过电压的基本原理为基础,利用EMTP-ATP计算机软件,构建中性点不接地系统仿真模型。以电压互感器的励磁特性、三相参数不平衡2大因素对铁磁谐振影响为例,进行仿真计算分析。仿真结果表明:PT铁磁特性较佳,可以减少谐振发生的概率,不过不能完全消除;此外,PT铁磁谐振产生较多的几率,受三相参数不平衡,或者对地电容大小不平衡等因素影响较大。基于仿真结果开展对各影响因素范围进行比较,进而为10 kV配网电压互感器PT铁磁谐振防治措施提供相关参考数据。 展开更多
关键词 10 kV配电网电压 互感器 pt铁磁谐振 电压仿真