期刊文献+
共找到96篇文章
< 1 2 5 >
每页显示 20 50 100
STUDY ON THE METHOD OF CONSTRUCTING RATIONAL CUBIC CURVES AND CURVED SURFACE INCLUDING CONTROLLING PARAMETERS
1
作者 孙兰凤 高天真 +1 位作者 梁艳书 陈健 《Transactions of Tianjin University》 EI CAS 1998年第1期31-36,共6页
By adopting the method of controlling parameters this paper describes the construction of various kinds of cubic curve segment and curved surface fragment with rational and non rational parameters, and discusses the ... By adopting the method of controlling parameters this paper describes the construction of various kinds of cubic curve segment and curved surface fragment with rational and non rational parameters, and discusses the relationship between controlling parameters, weighted factors and types, kinds and characteristics of curve segments and curved surface fragments. A mathematical method is provided for CAGD with abundant connotations, broad covering region, convenience, flexibility and direct simplicity. 展开更多
关键词 controlling parameter weighted factor rational and non rational curve segment curved surface fragment matrix of parametric coefficient
下载PDF
Self-adapting control parameters modifieddifferential evolution for trajectoryplanning of manipulators 被引量:12
2
作者 Lianghong WU Yaonan WANG Shaowu ZHOU 《控制理论与应用(英文版)》 EI 2007年第4期365-373,共9页
Control parameters of original differential evolution (DE) are kept fixed throughout the entire evolutionary process. However, it is not an easy task to properly set control parameters in DE for different optiinizat... Control parameters of original differential evolution (DE) are kept fixed throughout the entire evolutionary process. However, it is not an easy task to properly set control parameters in DE for different optiinization problems. According to the relative position of two different individual vectors selected to generate a difference vector in the searching place, a self-adapting strategy for the scale factor F of the difference vector is proposed. In terms of the convergence status of the target vector in the current population, a self-adapting crossover probability constant CR strategy is proposed. Therefore, good target vectors have a lower CFI while worse target vectors have a large CFI. At the same time, the mutation operator is modified to improve the convergence speed. The performance of these proposed approaches are studied with the use of some benchmark problems and applied to the trajectory planning of a three-joint redundant manipulator. Finally, the experiment results show that the proposed approaches can greatly improve robustness and convergence speed. 展开更多
关键词 Self-adapting control parameters Differential evolution Redundant manipulator Trajectory planning
下载PDF
Influence of Pre-injection Control Parameters on Main-injection Fuel Quantity for an Electronically Controlled Double-valve Fuel Injection System of Diesel Engine 被引量:3
3
作者 Enzhe Song Liyun Fan Chao Chen Quan Dong Xiuzhen Yun Bai 《Journal of Marine Science and Application》 2013年第3期366-373,共8页
A simulation model of an electronically controlled two solenoid valve fuel injection system for a diesel engine is established in the AMESim environment.The accuracy of the model is validated through comparison with e... A simulation model of an electronically controlled two solenoid valve fuel injection system for a diesel engine is established in the AMESim environment.The accuracy of the model is validated through comparison with experimental data.The influence of pre-injection control parameters on main-injection quantity under different control modes is analyzed.In the spill control valve mode,main-injection fuel quantity decreases gradually and then reaches a stable level because of the increase in multi-injection dwell time.In the needle control valve mode,main-injection fuel quantity increases with rising multi-injection dwell time;this effect becomes more obvious at high-speed revolutions and large main-injection pulse widths.Pre-injection pulse width has no obvious influence on main-injection quantity under the two control modes;the variation in main-injection quantity is in the range of 1 mm3. 展开更多
关键词 diesel engine double-valve fuel injection system pre-injection control parameters main-injection fuel quantity
下载PDF
IMPLICIT ITERATIVE METHODS WITH VARIABLE CONTROL PARAMETERS FOR ILL-POSED OPERATOR EQUATIONS 被引量:2
4
作者 贺国强 王新革 刘林先 《Acta Mathematica Scientia》 SCIE CSCD 2000年第4期485-494,共10页
This paper discusses a kind of implicit iterative methods with some variable parameters, which are called control parameters, for solving ill-posed operator equations. The theoretical results show that the new methods... This paper discusses a kind of implicit iterative methods with some variable parameters, which are called control parameters, for solving ill-posed operator equations. The theoretical results show that the new methods always lead to optimal convergence rates and have some other important features, especially the methods can be implemented parallelly. 展开更多
关键词 III-posed problems implicit iterative methods variable control parameters parallel algorith?
下载PDF
Development of a Novel Feedforward Neural Network Model Based on Controllable Parameters for Predicting Effluent Total Nitrogen 被引量:4
5
作者 Zihao Zhao Zihao Wang +5 位作者 Jialuo Yuan Jun Ma Zheling He Yilan Xu Xiaojia Shen Liang Zhu 《Engineering》 SCIE EI 2021年第2期195-202,共8页
The problem of effluent total nitrogen(TN)at most of the wastewater treatment plants(WWTPs)in China is important for meeting the related water quality standards,even under the condition of high energy consumption.To a... The problem of effluent total nitrogen(TN)at most of the wastewater treatment plants(WWTPs)in China is important for meeting the related water quality standards,even under the condition of high energy consumption.To achieve better prediction and control of effluent TN concentration,an efficient prediction model,based on controllable operation parameters,was constructed in a sequencing batch reactor process.Compared with previous models,this model has two main characteristics:①Superficial gas velocity and anoxic time are controllable operation parameters and are selected as the main input parameters instead of dissolved oxygen to improve the model controllability,and②the model prediction accuracy is improved on the basis of a feedforward neural network(FFNN)with algorithm optimization.The results demonstrated that the FFNN model was efficiently optimized by scaled conjugate gradient,and the performance was excellent compared with other models in terms of the correlation coefficient(R).The optimized FFNN model could provide an accurate prediction of effluent TN based on influent water parameters and key control parameters.This study revealed the possible application of the optimized FFNN model for the efficient removal of pollutants and lower energy consumption at most of the WWTPs. 展开更多
关键词 Feedforward neural network(FFNN) Algorithms controllable operation parameters Sequencing batch reactor(SBR) Total nitrogen(TN)
下载PDF
Design of cavern blasting based on controllable parameters 被引量:2
6
作者 王树理 王树仁 朱建明 《Journal of Coal Science & Engineering(China)》 2008年第2期235-238,共4页
After a thorough review of some controllable parameters,which included field investigations,cavern dimensions,explosive,rock strength etc.,cut,contour,lifters and stoping holes were introduced for blasting cavern of n... After a thorough review of some controllable parameters,which included field investigations,cavern dimensions,explosive,rock strength etc.,cut,contour,lifters and stoping holes were introduced for blasting cavern of nucleus submarine.These design were conducted using a U.Langefors and B.Kihlstrom theory. 展开更多
关键词 controllable parameters large cross-section cavern cavern blasting design
下载PDF
Integrated Optimization of Structure and Control Parameters for the Height Control System of a Vertical Spindle Cotton Picker 被引量:1
7
作者 Xingzheng Chen Congbo Li +2 位作者 Rui Hu Ning Liu Chi Zhang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2021年第6期405-416,共12页
Vertical picking method is a predominate method used to harvest cotton crop.However,a vertical picking method may cause spindle bending of the cotton picker if spindles collide with stones on the cotton field.Thus,how... Vertical picking method is a predominate method used to harvest cotton crop.However,a vertical picking method may cause spindle bending of the cotton picker if spindles collide with stones on the cotton field.Thus,how to realize a precise height control of the cotton picker is a crucial issue to be solved.The objective of this study is to design a height control system to avoid the collision.To design it,the mathematical models are established first.Then a multi-objective optimization model represented by structure parameters and control parameters is proposed to take the pressure of chamber without piston,response time and displacement error of the height control system as the opti-mization objectives.An integrated optimization approach that combines optimization via simulation,particle swarm optimization and simulated annealing is proposed to solve the model.Simulation and experimental test results show that the proposed integrated optimization approach can not only reduce the pressure of chamber without piston,but also decrease the response time and displacement error of the height control system. 展开更多
关键词 Cotton picker Height control system Structure parameters control parameters Integrated optimization
下载PDF
THE STUDY ON A KIND OF CONTROL SYSTEM WITH NONLINEAR PARABOLIC DISTRIBUTED PARAMETERS
8
作者 ZHOU Jian-jun(周建军) +1 位作者 XU Yan-hou(徐燕侯) 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2002年第2期178-186,共9页
The modelling of one kind of nonlinear parabolic distributed parameter control system with moving boundary, which had extensive applications was presented, Two methods were used to investigate the basic characteristic... The modelling of one kind of nonlinear parabolic distributed parameter control system with moving boundary, which had extensive applications was presented, Two methods were used to investigate the basic characteristics of the system: I) transforming the system it? the variable domain into that in the fixed domain; 2) transforming the distributed parameter system into the lumped parameter system. It is found that there are two critical values for the control variable : the larger one determines whether or not the boundary would move, while the smaller one determines whether or not the boundary, would atop automatically. For one-dimensional system of planar, cylindrical and spherical cases the definite solution problem can be expressed as a unified form. By means of the computer simulation the open-loop control system and close-cycle feedback control system have been investigated. Numerical results agree well with theoretical results. The computer simulation shows that the system is well posed, stable, measurable and controllable. 展开更多
关键词 distributed parameter control system NONLINEAR moving boundary stability MEASURABILITY controlLABILITY
下载PDF
Relative Content of Phenoxyethanol and p-Hydroxyacetophenone in Water Phase of Oil-water Systems and Teir Relevant Control Parameters 被引量:1
9
作者 Xiaoling Qiao Ping Cao +7 位作者 Yuanhua Cong Chunbo Feng Zhitao Chen Xuepu Li Lingling Zhang Qin Zhu Zheng Wang Xinran Li 《China Detergent & Cosmetics》 2016年第4期43-49,共7页
In emulsion system, micro-organisms survive in water phase, thus concentration of preservative in water phase directly reflects to anti-fungi efficacy. As preservative easily migrates into oil phase, it reduces preser... In emulsion system, micro-organisms survive in water phase, thus concentration of preservative in water phase directly reflects to anti-fungi efficacy. As preservative easily migrates into oil phase, it reduces preservative efficacy. A common solution is to increase preservative amount in the whole system. However this way always brings safety issues as preservative is a major allergen. Another effective but safety way is to prohibit preservative migrating into oil phase. In cosmetic research area, phenoxyethanol (PE) and p-Hydroxyacetophenone (p-HAP) pair gradually emerges to be a popular preservative candidate. Thus this new preservative system has been focused as the research object in this work. The relative contents (C) of both PE (CPE) and p-HAP (Cp-HAP) in water phase has been carefully determined. Eight commonly used oils have been further employed to check CPE and Cp-HAP in different oil-water system. The other infuence parameters such as polyols, processing parameters are also investigated. Results shows squalane, petrolatum, silicone oil and hydrogenated polyisobutene might be good oil phase candidates for formulation when using PE and p-HAP preservative system. In these oil systems, PE and p-HAP are mainly located in water phase. Besides, increasing percentage of 1, 3-butylene glycol, shortening homogenization time or adding preservatives at the end of processing under lower temperature could effectively increase effective content preservatives in water phase, either. 展开更多
关键词 PRESERVATIVE phenoxyethanol p-Hydroxyacetophenone relative content control parameter
下载PDF
Optimization of control parameters for petroleum waste composting
10
作者 MA Ying ZHANG Jia yao +1 位作者 WONG Ming Hung WU Wen zhong 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2001年第4期385-390,共6页
Composting is being widely employed in the treatment of petroleum waste. The purpose of this study was to find the optimum control parameters for petroleum waste in-vessel composting. Various physical and chemical par... Composting is being widely employed in the treatment of petroleum waste. The purpose of this study was to find the optimum control parameters for petroleum waste in-vessel composting. Various physical and chemical parameters were monitored to evaluate their influence on the microbial communities present in composting. The CO2 evolution and the number of microorganisms were measured as the activity of composting. The results demonstrated that the optimum temperature, pH and moisture content were 56.5 - 59.5 degreesC, 7.0 - 8.5 and 55 % - 60%, respectively. Under the optimum conditions, the removal efficiency of petroleum hydrocarbon reached 83.29% after 30 days composting. 展开更多
关键词 OPTIMIZATION control parameters petroleum waste COMPOSTING
下载PDF
Evolvement regularity of signal control parameters of urban road in cold region
11
作者 蒋贤才 苏小红 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第6期873-878,共6页
In snow-icy road environment, the survey data indicate that the largest decrease in traffic flow running characters occurs when snow and ice begin to accumulate on the road surface. Saturation flow is decreased by 16%... In snow-icy road environment, the survey data indicate that the largest decrease in traffic flow running characters occurs when snow and ice begin to accumulate on the road surface. Saturation flow is decreased by 16% , speed is decreased by 30% , and start-up lost time is increased by 27%. Based on the signal control theory of HCM and Webster, the character values of traffic flow in different urban road environments were investigated, and the evolvement regularity of signal control parameters such as cycle, split, green time, offset, yellow time and red time in snow-icy road environment was analyzed. The impact factors and the changes in the scope of signal control parameters were achieved. Simulation results and practical application show that the signal control plan of road enviromnent without snow and ice will increase the vehicle delay, stop length and traffic congestion in snow-icy road environment. Thus, the traffic signal control system should address a suitable signal control plan based on different road environments. 展开更多
关键词 evolvement regularity of signal control parameter traffic simulation cold region urban road
下载PDF
Simulation Study on the Controllable Dielectrophoresis Parameters of Graphene
12
作者 Jian-Long Ji Ya-Li Liu +7 位作者 Yang Ge Sheng-Dong Xie Xi Zhang Sheng-Bo Sang Ao-Qun Jian Qian-Qian Duan Qiang Zhang Wen-Dong Zhang 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第4期71-74,共4页
The method of using dielectrophoresis (DEP) to assemble graphene between micro-electrodes has been proven to be simple and efficient. We present an optimization method for the kinetic formula of graphene DEP, and di... The method of using dielectrophoresis (DEP) to assemble graphene between micro-electrodes has been proven to be simple and efficient. We present an optimization method for the kinetic formula of graphene DEP, and discuss the simulation of the graphene assembly process based on the finite element method. The simulated results illustrate that the accelerated motion of graphene is in agreement with the distribution of the electric field squared gradient. We also conduct research on the controllable parameters of the DEP assembly such as the alternating current (AC) frequency, the shape of micro-electrodes, and the ratio of the gap between electrodes to the characteristic/geometric length of graphene (λ). The simulations based on the Clausius-Mossotti factor reveal that both graphene velocity and direction are influenced by the AC frequency. When graphene is close to the electrodes, the shape of micro-electrodes will exert great influence on the velocity of graphene. Also, λ has a great influence on the velocity of graphene. Generally, the velocity of graphene would be greater when λ is in the range of 0.4 0.6. The study is of a theoretical guiding significance in improving the precision and efficiency of the graphene DEP assembly. 展开更多
关键词 DEP Simulation Study on the controllable Dielectrophoresis parameters of Graphene
下载PDF
Research on Anti-Fluctuation Control of Winding Tension System Based on Feedforward Compensation
13
作者 Yujie Duan Jianguo Liang +4 位作者 Jianglin Liu Haifeng Gao Yinhui Li Jinzhu Zhang Xinyu Wen 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1239-1261,共23页
In the fiber winding process,strong disturbance,uncertainty,strong coupling,and fiber friction complicate the winding constant tension control.In order to effectively reduce the influence of these problems on the tens... In the fiber winding process,strong disturbance,uncertainty,strong coupling,and fiber friction complicate the winding constant tension control.In order to effectively reduce the influence of these problems on the tension output,this paper proposed a tension fluctuation rejection strategy based on feedforward compensation.In addition to the bias harmonic curve of the unknown state,the tension fluctuation also contains the influence of bounded noise.A tension fluctuation observer(TFO)is designed to cancel the uncertain periodic signal,in which the frequency generator is used to estimate the critical parameter information.Then,the fluctuation signal is reconstructed by a third-order auxiliary filter.The estimated signal feedforward compensates for the actual tension fluctuation.Furthermore,a time-varying parameters fractional-order PID controller(TPFOPID)is realized to attenuate the bounded noise in the fluctuation.Finally,TPFOPID is enhanced by TFO and applied to control a tension control system considering multi-source disturbances.The stability of the method is analyzed by using the Lyapunov theorem.Finally,numerical simulations verify that the proposed scheme improves the tracking ability and robustness of the system in response to tension fluctuations. 展开更多
关键词 Constant tension control anti-fluctuation strategy tension fluctuation observer time-varying parameters fractional-order PID controller feedforward compensate
下载PDF
ADAPTIVE GENETIC ALGORITHM BASED ON SIX FUZZY LOGIC CONTROLLERS 被引量:3
14
作者 朱力立 张焕春 经亚枝 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2003年第2期230-235,共6页
The performance of genetic algorithm(GA) is determined by the capability of search and optimization for satisfactory solutions. The new adaptive genetic algorithm(AGA) is built for inducing suitable search and optimiz... The performance of genetic algorithm(GA) is determined by the capability of search and optimization for satisfactory solutions. The new adaptive genetic algorithm(AGA) is built for inducing suitable search and optimization relationship. The use of six fuzzy logic controllers(6FLCs) is proposed for dynamic control genetic operating parameters of a symbolic-coded GA. This paper uses AGA based on 6FLCs to deal with the travelling salesman problem (TSP). Experimental results show that AGA based on 6FLCs is more efficient than a standard GA in solving combinatorial optimization problems similar to TSP. 展开更多
关键词 adaptive genetic algorithm fuzzy controller dynamic parameters control TSP
下载PDF
Planar morphology and controlling factors of the gullies in the Yuanmou Dry-hot Valley based on field investigation 被引量:3
15
作者 DENG Qingchun MIAO Fang +5 位作者 ZHANG Bin LUO Mingliang LIU Hui LIU Xiaojiao QIN Fachao LIU Gangcai 《Journal of Arid Land》 SCIE CSCD 2015年第6期778-793,共16页
The plane form of a gully can provide a basis for evaluating the gully volume and erosion rate, acting process, and evolutionary stage. For describing the planar characteristics of a permanent gully and understanding ... The plane form of a gully can provide a basis for evaluating the gully volume and erosion rate, acting process, and evolutionary stage. For describing the planar characteristics of a permanent gully and understanding their controlling factors, this study, utilizing a total station and GPS RTK, measured the shoulder lines and channel curves of 112 gullies in six sites of the Yuanmou Dry-hot Valley and then mapped them by Arc GIS software and calculated nine parameters. The results showed that the channel lengths range from 10.88 to 249.11 m; the widths range from 6.20 to 40.99 m; the perimeters range from 54.11 to 541.67 m; the gully areas range from 153.02 to 6,930.30 m2; the left-side areas range from 92.93 to 4,027.20 m2; and the right-side areas range from 63.65 to 3,539.77 m2. The slightly sinuous and straight gullies account for 73.21% of the total gullies; the quantity of the right skewed gullies is 8.93% greater than that of the left skewed ones based on the symmetry ratio; the shape ratios range from 1.12 to 1.40 and the morphology ratios from 0.038 to 1.294; the fractal dimension is 1.192. Gullies in different sites have diverse planar characteristics. Except for the symmetry index, which was close to a negatively skewed distribution, all of the other parameters had the characteristic of positively skewed distribution. The gully area is related to the length and width, but the gully length has a weak correlation with the width. The evolutionary stage, topographic conditions, strata, soil properties, and piping erosion played very important roles in the gully planar morphology. This study could provide useful information for controlling gully erosion and safeguarding human habitation and engineering buildings. 展开更多
关键词 gully plane form morphological parameters controlling factors Yuanmou Dry-hot Valley
下载PDF
Distributed Secondary Control and Optimal Power Sharing in Microgrids 被引量:14
16
作者 Gang Chen Ening Feng 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI 2015年第3期304-312,共9页
We address the control problem of microgrids and present a fully distributed control system which consists of primary controller, secondary controller, and optimal active power sharing controller. Different from the e... We address the control problem of microgrids and present a fully distributed control system which consists of primary controller, secondary controller, and optimal active power sharing controller. Different from the existing control structure in microgrids, all these controllers are implemented as local controllers at each distributed generator. Thus, the requirement for a central controller is obviated. The performance analysis of the proposed control systems is provided, and the finite-time convergence properties for distributed secondary frequency and voltage controllers are achieved. Moreover, the distributed control system possesses the optimal active power sharing property. In the end, a microgrid test system is investigated to validate the effectiveness of the proposed control strategies. © 2014 Chinese Association of Automation. 展开更多
关键词 control system analysis control systems Distributed parameter control systems Distributed parameter networks Electric power distribution
下载PDF
Controlled attenuation parameter for non-invasive assessment of hepatic steatosis in Chinese patients 被引量:56
17
作者 Feng Shen Rui-Dan Zheng +11 位作者 Yu-Qiang Mi Xiao-Ying Wang Qin Pan Guang-Yu Chen Hai-Xia Cao Ming-Li Chen Liang Xu Jian-Neng Chen Yi Cao Rui-Nan Zhang Lei-Ming Xu Jian-Gao Fan 《World Journal of Gastroenterology》 SCIE CAS 2014年第16期4702-4711,共10页
AIM: To evaluate the performance of a novel non-invasive controlled attenuation parameter (CAP) to assess liver steatosis.
关键词 Fatty liver NONALCOHOLIC controlled attenuation parameter Transient elastography Chronic hepatitis B
下载PDF
High value of controlled attenuation parameter predicts a poor antiviral response in patients with chronic hepatits B 被引量:11
18
作者 Jing Chen Meng-Lan Wang +2 位作者 Qin Long Lang Bai Hong Tang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2017年第4期370-374,共5页
BACKGROUND: Controlled attenuation parameter (CAP) is a non-invasive method for diagnosing hepatic steatosis based on vibration-controlled transient elastography. The objective of this study was to investigate the eff... BACKGROUND: Controlled attenuation parameter (CAP) is a non-invasive method for diagnosing hepatic steatosis based on vibration-controlled transient elastography. The objective of this study was to investigate the effect of high value of CAP on antiviral therapy in patients with chronic hepatitis B (CHB). METHODS: Patients with CHB receiving enticavir for initial antiviral therapy were studied; they were divided into the high CAP group and normal CAP group at baseline according to the CAP values. The effect of the antiviral therapy between the two groups were compared at week 12, 24 and 48. Patients with high CAP value at baseline were divided into three subgroups, mild, moderate and severe elevation; the therapeutic response were compared among patients with normal CAP and subgroups of patients with elevated CAP. RESULTS: A total of 153 patients were enrolled. Among them, 63 were in the high CAP group and 90 in the normal CAP group. Patients with high CAP had lower rates of ALT normalization and HBV DNA clearance in response to antiviral therapy compared with those with normal CAP at week 12, 24 and 48. Further analysis showed that the rate of ALT normalization in patients with mildly and moderately elevated CAP were significant lower than those with normal CAP at week 12 and 24; while the difference was not significant between the patients with normal CAP and those with severely elevated CAP. The rate of HBV DNA clearance was significantly lower in patients with severely elevated CAP compared with those with normal CAP at week 12, 24 and 48. CONCLUSION: CHB patients with high CAP had poor response to antiviral therapy. 展开更多
关键词 controlled attenuation parameter chronic hepatitis B TREATMENT
下载PDF
A novel methodology for constructing a multi-wing chaotic and hyperchaotic system with a unified step function switching control 被引量:3
19
作者 张朝霞 禹思敏 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期83-94,共12页
This paper aims at developing a novel method of constructing a class of multi-wing chaotic and hyperchaotic system by introducing a unified step function. In order to overcome the essential difficulties in iteratively... This paper aims at developing a novel method of constructing a class of multi-wing chaotic and hyperchaotic system by introducing a unified step function. In order to overcome the essential difficulties in iteratively adjusting multiple parameters of conventional multi-parameter control, this paper introduces a unified step function controlled by a single parameter for constructing various multi-wing chaotic and hyperchaotic systems. In particular, to the best of the authors' knowledge, this is also the first time to find a non-equilibrium multi-wing hyperchaotic system by means of the unified step function control. According to the heteroclinic loop Shilnikov theorem, some properties for multi-wing attractors and its chaos mechanism are further discussed and analyzed. A circuit for multi-wing systems is designed and implemented for demonstration, which verifies the effectiveness of the proposed approach. 展开更多
关键词 non-equilibrium multi-wing hyperchaotic system single parameter control unified step function circuit implementation
下载PDF
Controlled attenuation parameter for evaluating liver steatosis in chronic viral hepatitis 被引量:7
20
作者 Giovanna Ferraioli Carmine Tinelli +4 位作者 Raffaella Lissandrin Mabel Zicchetti Barbara Dal Bello Gaetano Filice Carlo Filice 《World Journal of Gastroenterology》 SCIE CAS 2014年第21期6626-6631,共6页
AIM: To assess the performance of controlled attenuation parameter (CAP) in patients with chronic viral hepatitis.
关键词 Liver steatosis Noninvasive techniques controlled attenuation parameter Transient elastography Chronic liver disease
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部