An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is propose...An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges.展开更多
The frequency domain division theory of dyadic wavelet decomposition and wavelet packet decomposition (WPD) with orthogonal wavelet base frame are presented. The WPD coefficients of signals are treated as the outputs ...The frequency domain division theory of dyadic wavelet decomposition and wavelet packet decomposition (WPD) with orthogonal wavelet base frame are presented. The WPD coefficients of signals are treated as the outputs of equivalent bandwidth filters with different center frequency. The corresponding WPD entropy values of coefficients increase sharply when the discrete spectrum interferences (DSIs), frequency spectrum of which is centered at several frequency points existing in some frequency region. Based on WPD, an entropy threshold method (ETM) is put forward, in which entropy is used to determine whether partial discharge (PD) signals are interfered by DSIs. Simulation and real data processing demonstrate that ETM works with good efficiency, without pre-knowing DSI information. ETM extracts the phase of PD pulses accurately and can calibrate the quantity of single type discharge.展开更多
The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a nu...The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a number of simulations. The simulations were based on the well-known three capacitor model for partial discharge. An equivalent circuit was derived for partial discharge due to a single void in the insulation material of a power cable. The results obtained from the simulations will form the basis of the design proses of a non-intrusive condition monitoring technique. The technique is based on the classification of discharge activity according to five levels of PD. Future work will include the improvement of the simulation model by investigating the high frequency model of a power cable as well as the statistical nature of PD activity. This will improve the accuracy of the simulation results when compared to actual measurements. The work discussed in this paper will be used to construct and calibrate a practical model which will make use of PD measurements for non-intrusive condition monitoring of medium voltage electrical cables.展开更多
Expounds a partial discharge detection circuit and a microcomputer based partial discharge monitoring system. The importance of statistical phase position distribution of partial discharge events for failure diagnosi...Expounds a partial discharge detection circuit and a microcomputer based partial discharge monitoring system. The importance of statistical phase position distribution of partial discharge events for failure diagnosis of power transformer and discusses an artificial neural network trained with φ q patterns for pattern recognition of partial discharge is discussed in detail, which is proved to be effective for on line monitoring.展开更多
On-line partial discharge(PD)detection still remains a very challenging task because of the strong electromagnetic interferences.In this paper,a new method of de-noising,using complex Daubechies wavelet(CDW)transform,...On-line partial discharge(PD)detection still remains a very challenging task because of the strong electromagnetic interferences.In this paper,a new method of de-noising,using complex Daubechies wavelet(CDW)transform,has been proposed.It is a relatively recent enhancement to the real-valued wavelet transform because of tow important properties,which are nearly shift-invariant and availability of phase information.Those properties give CDW transform superiority over other real-valued wavelet transform,and then the construction algorithm of CDW is introduced in detail.Secondly,based on the real threshold algorithm of real-valued wavelet transform,complex threshold algorithm is devised.This algorithm take the different characteristics of real part and imaginary part of complex wavelet coefficients into account,it modifies the real and imaginary parts of complex wavelet coefficients respectively.Thirdly,to obtain a real de-noised signal,new combined information series is devised.By applying different combination of real part and imaginary part of de-noised complex signal,a real de-noised signal can be restored with higher peak signal-to-noise ratio(PSNR)and less distortion of original signals.Finally,On-site applications of extracting PD signals from noisy background by the optimal de-noising scheme based on CDW are illustrated.The on-site experimental results show that the optimal de-noising scheme is an effective way to suppress white noise in PD measurement.展开更多
Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the sta...Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.展开更多
To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD ...To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD UHF online monitoring in transformer is excessively large,therefore,it is not convenient for internal installation of transformer. Two types of compact UHF antennas with small sizes,a Hilbert fractal antenna and a small loop antenna are presented. PD experiments of three typically artificial insulation defects are executed and both antennas are used for PD measurement. The spectra of power via frequency of detected PD signals are analyzed and compared. The experimental results show that the Hilbert fractal antenna and small loop antenna are qualified for PD online UHF monitoring.展开更多
The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insu...The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited.展开更多
Exploitation of equipment with cross linked polyethylene (XLPE ) insulation requires its condition monitoring and diagnostic. Traditionally diagnostics of insulation is carried out by means of partial discharge detect...Exploitation of equipment with cross linked polyethylene (XLPE ) insulation requires its condition monitoring and diagnostic. Traditionally diagnostics of insulation is carried out by means of partial discharge detection. However, such identification of a defect, for example, void, inclusion or treeing, does not say about its danger from a point of view of full insulation gap breakdown and insulation construction failure. For this purpose a 29 kV CN-CV cable sample is studied. The experiment is based on research for determination of the dependencies between PD characteristics in XLPE upon time and three dimension PD patterns of corresponding treeing. The investigations were carried out by means of electrical measurement of PD current and simultaneous optical recording of treeing image. The needleplane electrode is applied as the electrode. As a result, -q-n PD patterns which are used as the bases to bush tree initialization and growth can be obtained. Test results show that PD pattern recognition can be applied as a powerful tool for recognizing electrical tree initialization and growth. This can make a good basis for on-line condition monitoring of high voltage power cable.展开更多
This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF...This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective.展开更多
文摘An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges.
基金Funded by the of the Key Teachers Foundation under the State Ministry Education.
文摘The frequency domain division theory of dyadic wavelet decomposition and wavelet packet decomposition (WPD) with orthogonal wavelet base frame are presented. The WPD coefficients of signals are treated as the outputs of equivalent bandwidth filters with different center frequency. The corresponding WPD entropy values of coefficients increase sharply when the discrete spectrum interferences (DSIs), frequency spectrum of which is centered at several frequency points existing in some frequency region. Based on WPD, an entropy threshold method (ETM) is put forward, in which entropy is used to determine whether partial discharge (PD) signals are interfered by DSIs. Simulation and real data processing demonstrate that ETM works with good efficiency, without pre-knowing DSI information. ETM extracts the phase of PD pulses accurately and can calibrate the quantity of single type discharge.
文摘The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a number of simulations. The simulations were based on the well-known three capacitor model for partial discharge. An equivalent circuit was derived for partial discharge due to a single void in the insulation material of a power cable. The results obtained from the simulations will form the basis of the design proses of a non-intrusive condition monitoring technique. The technique is based on the classification of discharge activity according to five levels of PD. Future work will include the improvement of the simulation model by investigating the high frequency model of a power cable as well as the statistical nature of PD activity. This will improve the accuracy of the simulation results when compared to actual measurements. The work discussed in this paper will be used to construct and calibrate a practical model which will make use of PD measurements for non-intrusive condition monitoring of medium voltage electrical cables.
文摘Expounds a partial discharge detection circuit and a microcomputer based partial discharge monitoring system. The importance of statistical phase position distribution of partial discharge events for failure diagnosis of power transformer and discusses an artificial neural network trained with φ q patterns for pattern recognition of partial discharge is discussed in detail, which is proved to be effective for on line monitoring.
基金Project Supported by National Natural Science Foundation China(50577069), National Grid Company (2004-SGKJ).
文摘On-line partial discharge(PD)detection still remains a very challenging task because of the strong electromagnetic interferences.In this paper,a new method of de-noising,using complex Daubechies wavelet(CDW)transform,has been proposed.It is a relatively recent enhancement to the real-valued wavelet transform because of tow important properties,which are nearly shift-invariant and availability of phase information.Those properties give CDW transform superiority over other real-valued wavelet transform,and then the construction algorithm of CDW is introduced in detail.Secondly,based on the real threshold algorithm of real-valued wavelet transform,complex threshold algorithm is devised.This algorithm take the different characteristics of real part and imaginary part of complex wavelet coefficients into account,it modifies the real and imaginary parts of complex wavelet coefficients respectively.Thirdly,to obtain a real de-noised signal,new combined information series is devised.By applying different combination of real part and imaginary part of de-noised complex signal,a real de-noised signal can be restored with higher peak signal-to-noise ratio(PSNR)and less distortion of original signals.Finally,On-site applications of extracting PD signals from noisy background by the optimal de-noising scheme based on CDW are illustrated.The on-site experimental results show that the optimal de-noising scheme is an effective way to suppress white noise in PD measurement.
基金Project supported by National Basic Research Program of China (973 Program) (2011CB 209400)State Key Laboratory of Control and Simulation of Power Systems and Generation Equipments (SKLD10M09)Program for ±1 100 kV UHVDC Technology
文摘Direct current (DC) partial discharge (PD) test has drawn extensive attention from world-wide electric power research institutes in recent years. However, presently, no DC PD detection device on the market has the statistical function. Thus, we developed a test system for PD detection under DC voltage, which is characterized by strong anti-jamming capability, continuous high-speed real-time data acquisi- tion and effective, complete detection of DC PD signals. The DC PD mechanism, as well as the measuring principles, software system, and hardware design of the test equipment were introduced. Adopting typical electrode pairs, we tested the statistical spectrum of PD under DC voltage. The main difference in statistical spectrums between parallel plate electrodes and needle-plate electrodes was that the time interval between two consecutive discharges for needle-plate electrodes has obviously larger variation range than that for parallel plate electrodes, which could be the convincing proof for distinguishing the type of electrodes under DC PD. Practical results indicate that the proposed sys- tem can measure time domain signals of DC PD of oil-paper insulation effectively and promptly, and it can be used to determine and detect defects in DC power transmission equipment.
基金Project Supported by New Century ExcellentTalents of the Ministry of Education (NCET-06-0763)the Foundation of the Key Project of the Science and Technology Depart ment inChongqing (CSTC2005AA6003)
文摘To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD UHF online monitoring in transformer is excessively large,therefore,it is not convenient for internal installation of transformer. Two types of compact UHF antennas with small sizes,a Hilbert fractal antenna and a small loop antenna are presented. PD experiments of three typically artificial insulation defects are executed and both antennas are used for PD measurement. The spectra of power via frequency of detected PD signals are analyzed and compared. The experimental results show that the Hilbert fractal antenna and small loop antenna are qualified for PD online UHF monitoring.
基金Project supported by National High-tech Research and Development Program of China (863 Program) (2011AA05A121)
文摘The understanding of the excitation mechanism of ultra high frequency (UHF) electromagnetic waves (EW) is essential for ap- plying UHF method to partial discharge (PD) detection. Since the EW induced by PD in gas insulated switchgear (GIS) contains not only transverse electromagnetic (TEM) wave, but also high-order transverse electric (TE) and high-order transverse magnetic (TM) waves, we analyzed the proportions between the TEM wave and the high order waves, as well as the influence of the PD position on this proportion, using the finite different time domain (FDTD) method. According to the unique characteristics of the waves, they are separated only ap- proximately. It is found that the high-order mode is the main component, more than 70%, of the electric field around the enclosure of GIS, and that with the increasing distance between PD source and inner conductors, the low frequency ( below about 800 MHz) component of EW decreases, but the high frequency component (above 1 GHz) increases, meanwhile the proportion of high-order components in EW could reach 77% from 70%. It concluded that the closer the PD source to the enclosure is, the easier high order EW may be excited.
基金The project supported by the Science and Engineering Reserch Fund of Southwest JiaotongUniversity(1999 XM02) and the Startup F
文摘Exploitation of equipment with cross linked polyethylene (XLPE ) insulation requires its condition monitoring and diagnostic. Traditionally diagnostics of insulation is carried out by means of partial discharge detection. However, such identification of a defect, for example, void, inclusion or treeing, does not say about its danger from a point of view of full insulation gap breakdown and insulation construction failure. For this purpose a 29 kV CN-CV cable sample is studied. The experiment is based on research for determination of the dependencies between PD characteristics in XLPE upon time and three dimension PD patterns of corresponding treeing. The investigations were carried out by means of electrical measurement of PD current and simultaneous optical recording of treeing image. The needleplane electrode is applied as the electrode. As a result, -q-n PD patterns which are used as the bases to bush tree initialization and growth can be obtained. Test results show that PD pattern recognition can be applied as a powerful tool for recognizing electrical tree initialization and growth. This can make a good basis for on-line condition monitoring of high voltage power cable.
文摘This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective.