Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltag...Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios.展开更多
The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments wi...The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.展开更多
For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.Ho...For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.展开更多
HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics...HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics of HFO-1234 ze(E)/N2 mixtures were studied using the gas insulation test platform.The PD inception voltage of insulating gas under positive and negative half cycles of power frequency was tested.Using SF6/N2 mixtures as a control group,the effects of electrode spacing,mixing ratio and pressure on the insulation performance of HFO-1234 ze(E)/N2 mixtures were explored.The test results show that the PD inception voltage of the negative half-cycle of pure HFO-1234 ze(E)under short electrode spacing can reach 0.96-1.04 times of pure SF6 under different pressures;the PD inception voltage of40%HFO-1234 ze(E)/60%N2 mixtures at 0.3 MPa is 0.67-0.89 times that of SF6/N2 mixtures under the same conditions,which has great application prospect.展开更多
Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of ...Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of high voltage IGBT modules are insufficient;for example,partial discharge resistance under DC voltage blocking condition is not considered.In this paper,a new test was proposed to allow the measurement of partial discharges in all the components of IGBT modules under DC voltage.The topology of the measuring circuit is arranged in the polarity discrimination way to exclude the interference,and the voltage and discharge current waveforms during the partial discharge process are measured by the wideband time domain measurement technique.According to the proposed test,the discharge phenomenon of the IGBT modules below the rating voltage were detected.A comprehensive waveform analysis on the voltage and discharge current was performed,and the influence of the applied voltage on the waveform parameters was obtained.The waveform parameters are influenced by the applied voltage and insulation structure,which enables the discrimination of the causes of the observed partial discharge in the IGBT module under DC voltage by the waveform analysis technique.Based on the waveform analysis technique,the types and causes of the observed partial discharges were discussed and inferred,and the correctness of the inference was further verified by observation.The proposed test and waveform analysis technique provide the possibility to evaluate and distinguish partial discharges in the high voltage IGBT module under DC voltage,which may be helpful to insulation performance evaluation and insulation defect diagnosis in high voltage IGBT module.展开更多
Due to overvoltage produced by inverter output,inverter-fed motor insulation systems often experience fast electrical aging process,especially when partial discharge(PD) is incepted.Before putting into use,the PD dete...Due to overvoltage produced by inverter output,inverter-fed motor insulation systems often experience fast electrical aging process,especially when partial discharge(PD) is incepted.Before putting into use,the PD detection should be performed on inverter-fed motors at repetitive square voltages to avoid the PD caused insulation deterioration when the motors are collected to inverters having specific characteristics.However,unlike PD tests at AC/DC voltages proposed in IEC 60270,the PD detection at repetitive square voltages is much more complex because of serious interference generated by impulse generator.To solve the problem,ultra-high frequency(UHF) method seems recommendable for its preferable signal-to-noise ratio(SNR).The chief aim of this study is to investigate PD pulse and statistical characteristics of turn-to-turn insulation for inverter-fed traction motors.A square-shaped Archimedes antenna,specially designed for the PD detection at repetitive square voltages of fast rise times,was used to perform PD tests on turn-to-turn insulation models.Time and frequency analysis results indicate that energy component of generator disturbance and PD pulses are mainly distributed in the 0-0.5 GHz and 0.6-1.5 GHz range,respectively.Based on the results,suitable filter was designed for power disturbance suppression.Additionally,resorting to the sensor unit(i.e.antenna and filter) and the PD test system,the PD statistical features at square voltages of different frequencies were obtained.Experimental results show that higher frequency will give rise,statistically,to PD of lower magnitudes distributing at smaller phases.A reasonable interpretation of this phenomenon was presented.Lastly,according to the PD statistical features,some suggestions for the PD detection system design,generator parameter optimization and the PD pulse extracting were given.The results of this work would be beneficial to the increase of the sensitivity when performing the PD detection on insulation systems for inverter-fed motors at repetitive square voltages and thus,improving the reliability of inverter-fed motors.展开更多
The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges fro...The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of considerations for PD measurements on inverter-fed motors were provided to improve the sensitivity of the PD test system and to obtain high objective insulation lifetime test results, which are used to assess the insulation status of inverter-fed motors.展开更多
Converter transformers are the core device in ultrahigh voltage direct current(UHVDC)transmission systems,and the oil-paper insulation at its rectifying valve side deals with the composite AC-DC voltage.A detailed inv...Converter transformers are the core device in ultrahigh voltage direct current(UHVDC)transmission systems,and the oil-paper insulation at its rectifying valve side deals with the composite AC-DC voltage.A detailed investigation of the partial discharge(PD)mechanism in the oil-paper insulation under the composite AC-DC voltage is,therefore,very important.The oilpaper insulated needle plate electrode simulation model for the electric field and charge distribution can be established using hydrodynamic drift-diffusion theory and bipolar charge carrier theory,and the simulation results can reflect the morphological changes of PD.The development characteristics of PD under composite AC-DC voltage are researched.In addition,the effects of simulation time,the AC-DC component proportion,and model parameters on PD are also explored.Results indicate that differences in applied voltage,interface charge,and geometry structure can cause changes in the electric field strength,which consequently influences the PD process in the simulation model.Oil-immersed paperboard is a type of liquid-immersed dielectric(LID).When the LID is arranged in perpendicular,only the positive streamers have narrow channels oriented toward the LID.When the LID is arranged in parallel,the PDs are in the form of creeping discharges and the negative streamers are more dispersed.The development characteristics of PD and its influencing factors reported here may provide theoretical and simulation support to explain the physical mechanism of PD at the rectifying valve side of the converter transformer.展开更多
High-voltage storage capacitors(hereinafter call capacitors for short)have been widely used in pulsed power technology.In accordance with the actual work conditions of capacitors,direct current partial discharge(DCPD)...High-voltage storage capacitors(hereinafter call capacitors for short)have been widely used in pulsed power technology.In accordance with the actual work conditions of capacitors,direct current partial discharge(DCPD)detection was put forward.The whole test system was based on the impedance balance circuit characterized by good configuration and anti-interference ability.Through DCPD detection on capacitors which contained four typical defects respectively,test results revealed that DCPD signals could well reflect the state of capacitor insulation.DCPD distribution spectra of capacitors containing four typical defects were obviously different.Defects in capacitors could be exactly judged by computer–aided pattern recognition based on support vector machine(SVM).展开更多
文摘Partial discharge test on a transformer is carried out according to the items in IEC 60. During the test, unproved measuring system is calibrated by proved system at a voltage no less than 50% the rated testing voltage. The result is then extrapolated linearly, leading to an error related to the distribution of stray capacitance, which varies with the testing frequency, especially to large transformers. In this paper a factor, named the capacitive rise fact, is introduced to assess the rise. The factor can be adjusted to some extent by changing the reactance that is connected to the LV side of the testing circuit to lower the capacity of the power source. However, the factor changes when the voltage divider on the high voltage side is removed after the voltage ratio has been calculated, and a great error is resulted under unfavorable conditios.
基金Project supported by National Basic Research Program of China(973 Program) (2011CB 209400)Program of State Key Laboratory of Power Systems for ±1 100 kV UHVDC Technology(SKLD10M09)
文摘The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.
基金supported by National High-tech Research and Development Program of China(863 Program)(2009AA04Z416) National Science Foundation of China(51021005) Scientific Innovation of Colleges and Universities(Project v-200704)
基金supported by National High-tech Research and Development Program of China(863 Program)(2009AA04Z416) National Science Foundation of China(51021005) Scientific Innovation of Colleges and Universities(200704)
基金supported by the National Key R&D Program of China(2017YFB0902704)the Science and Technology Project of SGCC(GY71-15-048)
文摘For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.
文摘HFO-1234 ze(E)(trans-1,3,3,3-tetrafluoropropene,chemical formula:C3H2F4)is an extremely environmentally friendly SF6 alternative gas with high electrical strength.In this paper,the partial discharge(PD)characteristics of HFO-1234 ze(E)/N2 mixtures were studied using the gas insulation test platform.The PD inception voltage of insulating gas under positive and negative half cycles of power frequency was tested.Using SF6/N2 mixtures as a control group,the effects of electrode spacing,mixing ratio and pressure on the insulation performance of HFO-1234 ze(E)/N2 mixtures were explored.The test results show that the PD inception voltage of the negative half-cycle of pure HFO-1234 ze(E)under short electrode spacing can reach 0.96-1.04 times of pure SF6 under different pressures;the PD inception voltage of40%HFO-1234 ze(E)/60%N2 mixtures at 0.3 MPa is 0.67-0.89 times that of SF6/N2 mixtures under the same conditions,which has great application prospect.
基金This work was supported by the National Natural Science Foundation of China-State Grid Corporation Joint Fund for Smart Grid(No.U1766219)the Fundamental Research Funds for the Central Universities(No.2017XS027).
文摘Insulation performance of high voltage IGBT modules is one of the key attributes in power system applications.However,the existing standards of IGBT devices and research on the evaluation of insulation performance of high voltage IGBT modules are insufficient;for example,partial discharge resistance under DC voltage blocking condition is not considered.In this paper,a new test was proposed to allow the measurement of partial discharges in all the components of IGBT modules under DC voltage.The topology of the measuring circuit is arranged in the polarity discrimination way to exclude the interference,and the voltage and discharge current waveforms during the partial discharge process are measured by the wideband time domain measurement technique.According to the proposed test,the discharge phenomenon of the IGBT modules below the rating voltage were detected.A comprehensive waveform analysis on the voltage and discharge current was performed,and the influence of the applied voltage on the waveform parameters was obtained.The waveform parameters are influenced by the applied voltage and insulation structure,which enables the discrimination of the causes of the observed partial discharge in the IGBT module under DC voltage by the waveform analysis technique.Based on the waveform analysis technique,the types and causes of the observed partial discharges were discussed and inferred,and the correctness of the inference was further verified by observation.The proposed test and waveform analysis technique provide the possibility to evaluate and distinguish partial discharges in the high voltage IGBT module under DC voltage,which may be helpful to insulation performance evaluation and insulation defect diagnosis in high voltage IGBT module.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51177136,50377035)Zhuzhou Electric Motor Company of South China Locomotive & Rolling Stock Corporation Lim-ited
文摘Due to overvoltage produced by inverter output,inverter-fed motor insulation systems often experience fast electrical aging process,especially when partial discharge(PD) is incepted.Before putting into use,the PD detection should be performed on inverter-fed motors at repetitive square voltages to avoid the PD caused insulation deterioration when the motors are collected to inverters having specific characteristics.However,unlike PD tests at AC/DC voltages proposed in IEC 60270,the PD detection at repetitive square voltages is much more complex because of serious interference generated by impulse generator.To solve the problem,ultra-high frequency(UHF) method seems recommendable for its preferable signal-to-noise ratio(SNR).The chief aim of this study is to investigate PD pulse and statistical characteristics of turn-to-turn insulation for inverter-fed traction motors.A square-shaped Archimedes antenna,specially designed for the PD detection at repetitive square voltages of fast rise times,was used to perform PD tests on turn-to-turn insulation models.Time and frequency analysis results indicate that energy component of generator disturbance and PD pulses are mainly distributed in the 0-0.5 GHz and 0.6-1.5 GHz range,respectively.Based on the results,suitable filter was designed for power disturbance suppression.Additionally,resorting to the sensor unit(i.e.antenna and filter) and the PD test system,the PD statistical features at square voltages of different frequencies were obtained.Experimental results show that higher frequency will give rise,statistically,to PD of lower magnitudes distributing at smaller phases.A reasonable interpretation of this phenomenon was presented.Lastly,according to the PD statistical features,some suggestions for the PD detection system design,generator parameter optimization and the PD pulse extracting were given.The results of this work would be beneficial to the increase of the sensitivity when performing the PD detection on insulation systems for inverter-fed motors at repetitive square voltages and thus,improving the reliability of inverter-fed motors.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51177136, 50377035)the Zhuzhou Electric Motor Company of the South China Locomotive & Rolling Stock Corporation,Limited
文摘The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of considerations for PD measurements on inverter-fed motors were provided to improve the sensitivity of the PD test system and to obtain high objective insulation lifetime test results, which are used to assess the insulation status of inverter-fed motors.
基金This work was supported in part by the Science and Technology Project of State Grid Corporation of China(No.52060020002P).
文摘Converter transformers are the core device in ultrahigh voltage direct current(UHVDC)transmission systems,and the oil-paper insulation at its rectifying valve side deals with the composite AC-DC voltage.A detailed investigation of the partial discharge(PD)mechanism in the oil-paper insulation under the composite AC-DC voltage is,therefore,very important.The oilpaper insulated needle plate electrode simulation model for the electric field and charge distribution can be established using hydrodynamic drift-diffusion theory and bipolar charge carrier theory,and the simulation results can reflect the morphological changes of PD.The development characteristics of PD under composite AC-DC voltage are researched.In addition,the effects of simulation time,the AC-DC component proportion,and model parameters on PD are also explored.Results indicate that differences in applied voltage,interface charge,and geometry structure can cause changes in the electric field strength,which consequently influences the PD process in the simulation model.Oil-immersed paperboard is a type of liquid-immersed dielectric(LID).When the LID is arranged in perpendicular,only the positive streamers have narrow channels oriented toward the LID.When the LID is arranged in parallel,the PDs are in the form of creeping discharges and the negative streamers are more dispersed.The development characteristics of PD and its influencing factors reported here may provide theoretical and simulation support to explain the physical mechanism of PD at the rectifying valve side of the converter transformer.
基金Supported by the National Natural Science Foundation of China(Grant No.10476022)Doctoral Innovation Fund of Southwest Jiaotong University
文摘High-voltage storage capacitors(hereinafter call capacitors for short)have been widely used in pulsed power technology.In accordance with the actual work conditions of capacitors,direct current partial discharge(DCPD)detection was put forward.The whole test system was based on the impedance balance circuit characterized by good configuration and anti-interference ability.Through DCPD detection on capacitors which contained four typical defects respectively,test results revealed that DCPD signals could well reflect the state of capacitor insulation.DCPD distribution spectra of capacitors containing four typical defects were obviously different.Defects in capacitors could be exactly judged by computer–aided pattern recognition based on support vector machine(SVM).