期刊文献+
共找到613篇文章
< 1 2 31 >
每页显示 20 50 100
Dynamic Response of Sea-Crossing Rail-cum-Road Cable-Stayed Bridge Influenced by Random Wind–Wave–Undercurrent Coupling
1
作者 BIAN Chen-jie DU Li-ming +2 位作者 WANG Ga-ping LI Xin LI Wei-ran 《China Ocean Engineering》 SCIE EI CSCD 2023年第1期85-100,共16页
Sea-crossing bridges are affected by random wind–wave–undercurrent coupling loads, due to the complex marine environment. The dynamic response of long-span Rail-cum-Road cable-stayed bridges is particularly severe u... Sea-crossing bridges are affected by random wind–wave–undercurrent coupling loads, due to the complex marine environment. The dynamic response of long-span Rail-cum-Road cable-stayed bridges is particularly severe under their influence, potentially leading to safety problems. In this paper, a fluid–structure separation solution method is implemented using Ansys–Midas co-simulation, in order to solve the above issues effectively while using less computational resources. The feasibility of the method is verified by comparing the tower top displacement response with relevant experimental data. From time and frequency domain perspectives, the displacement and acceleration responses of the sea-crossing Rail-cum-Road cable-stayed bridge influenced by wave-only, wind–wave, and wind–wave–undercurrent coupling are comparatively studied. The results indicate that the displacement and acceleration of the front bearing platform top are more significant than those of the rear bearing platform. The dominant frequency under wind–wave–undercurrent coupling is close to the natural vibration frequencies of several bridge modes,such that wind–wave–undercurrent coupling is more likely to cause a resonance effect in the bridge. Compared with the wave-only and wind–wave coupling, wind–wave–undercurrent coupling can excite bridges to produce larger displacement and acceleration responses: at the middle of the main girder span, compared with the wave-only case, the maximum displacement in the transverse bridge direction increases by 23.58% and 46.95% in the wind–wave and wind–wave–undercurrent coupling cases, respectively;at the tower top, the variation in the amplitude of the displacement and acceleration responses of wind–wave and wind–wave–undercurrent coupling are larger than those in the wave-only case, where the acceleration change amplitude of the tower top is from-0.93 to 0.86 m/s^(2) in the waveonly case, from-2.2 to 2.1 m/s^(2) under wind–wave coupling effect, and from-2.6 to 2.65 m/s^(2) under wind–wave–undercurrent coupling effect, indicating that the tower top is mainly affected by wind loads, but wave and undercurrent loads cannot be neglected. 展开更多
关键词 random wind WAVE undercurrent coupling effect Rail-cum-Road cable-stayed bridge dynamic response
下载PDF
Process Monitoring and Terminal Verification of Cable-Stayed Bridges with Corrugated Steel Webs under Contruction
2
作者 Kexin Zhang Xinyuan Shen +1 位作者 Longsheng Bao He Liu 《Structural Durability & Health Monitoring》 EI 2023年第2期131-158,共28页
In this paper,the construction process of a cable-stayed bridge with corrugated steel webs was monitored.Moreover,the end performance of the bridge was verified by load test.Owing to the consideration of the bridge st... In this paper,the construction process of a cable-stayed bridge with corrugated steel webs was monitored.Moreover,the end performance of the bridge was verified by load test.Owing to the consideration of the bridge structure safety,it is necessary to monitor the main girder deflection,stress,construction error and safety state during construction.Furthermore,to verify whether the bridge can meet the design requirements,the static and dynamic load tests are carried out after the completion of the bridge.The results of construction monitoring show that the stress state of the structure during construction is basically consistent with the theoretical calculation and design requirements,and both meet the design and specification requirements.The final measured stress state of the structure is within the allowable range of the cable-stayed bridge,and the stress state of the structure is normal and meets the specification requirements.The results of load tests show that the measured deflection values of the mid-span section of the main girder are less than the theoretical calculation values.The maximum deflection of the girder is−20.90 mm,which is less than−22.00 mm of the theoretical value,indicating that the girder has sufficient structural stiffness.The maximum impact coefficient under dynamic load test is 1.08,which is greater than 1.05 of theoretical value,indicating that the impact effect of heavy-duty truck on this type of bridge is larger.This study can provide important reference value for construction and maintenance of similar corrugated steel web cable-stayed bridges. 展开更多
关键词 cable-stayed bridge corrugated steel web construction monitoring static load test dynamic load test
下载PDF
Renewal Design of Pedestrian Bridges from the Perspective of Environmental Behaviors
3
作者 DONG Lili LIU Zhen JIANG Yawei 《Journal of Landscape Research》 2023年第2期32-38,共7页
With the continuous deepening of urbanization,the focus of urban construction has shifted to internal renewal,and the phenomenon of decreased vitality caused by the spatial limitations of pedestrian bridges with a sin... With the continuous deepening of urbanization,the focus of urban construction has shifted to internal renewal,and the phenomenon of decreased vitality caused by the spatial limitations of pedestrian bridges with a single transportation function as the main focus has gradually emerged.Based on this,environmental behavior theory is used to seek the convergence point between the material space and behavioral activities of pedestrian bridges to solve this dilemma.In this paper,the pedestrian bridge of Southwest Hospital of Army Medical University is taken as an example.Starting from the three types of spaces of pedestrian bridges,through behavior observation,interview research,and data analysis,the correlation between the material space of pedestrian bridges and the behavioral characteristics of the population is analyzed,stimulating the spatial vitality of pedestrian bridges,and providing reference for the sustainable development,construction,and renovation of pedestrian bridges. 展开更多
关键词 Environmental behavior pedestrian bridge Urban renewal Chongqing City
下载PDF
Semi-active control of a cable-stayed bridge under multiple-support excitations 被引量:6
4
作者 代泽兵 黄金枝 王红霞 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2004年第3期68-76,共9页
This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are pr... This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are proposed as control devices, a LQG-clipped-optimal control algorithm is employed. An active control strategy, shown in previous researches to perform well at controlling the benchmark bridge when uniform earthquake motion was assumed, is also used in this study to control this benchmark bridge with consideration of multiple-support excitations. The performance of active control system is compared to that of the presented semi-active control strategy. Because the MR fluid damper is a con-trollable energy- dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. The numerical results demonstrated that the performance of the presented control design is nearly the same as that of the active control system; and that the MR dampers can effectively be used to control seismically excited cable-stayed bridges with multiple-support excitations. 展开更多
关键词 cable-stayed bridge Multiple-support excitation MR damping SEMI-ACTIVE control
下载PDF
Numerical simulation of dynamic characteristics of a cable-stayed aqueduct bridge 被引量:8
5
作者 LiYuchun Di Qingshuang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第4期569-579,共11页
In this paper, a full-scale 3-D finite element model of the Jundushan cable-stayed aqueduct bridge is established with ANSYS Code. The shell, fluid, tension-only spar and beam elements are used for modeling the aquedu... In this paper, a full-scale 3-D finite element model of the Jundushan cable-stayed aqueduct bridge is established with ANSYS Code. The shell, fluid, tension-only spar and beam elements are used for modeling the aqueduct deck, filled water, cables and support towers, respectively. A multi-element cable formulation is introduced to simulate the cable vibration. The dry (without water) and wet (with water) modes of the aqueduct bridge are both extracted and investigated in detail. The dry modes of the aqueduct bridge are basically similar to those of highway cable-stayed bridges. A dry mode may correspond to two types of wet modes, which are called the in-phase (with lower frequency) and out-of-phase (with higher frequency) modes. When the water-structure system vibrates in the in-phase/out-of-phase modes, the aqueduct deck moves and water sloshes in the same/opposite phase-angle, and the sloshing water may take different surface-wave modes. The wet modes of the system reflect the properties of interaction among the deck, towers, cables and water. The in-phase wet frequency generally decreases as the water depth increases, and the out-of-phase wet frequency may increase or decrease as the water depth increases. 展开更多
关键词 cable-stayed aqueduct bridge dynamic characteristics fluid-structure interaction numerical simulation
下载PDF
Ground motion spatial variability effects on seismic response control of cable-stayed bridges 被引量:10
6
作者 Shehata E. Abdel Raheem Toshiro Hayashikawa Uwe Dorka 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第1期37-49,共13页
The spatial variability of input ground motion at supporting foundations plays a key role in the structural response of cable-stayed bridges (CSBs); therefore, spatial variation effects should be included in the ana... The spatial variability of input ground motion at supporting foundations plays a key role in the structural response of cable-stayed bridges (CSBs); therefore, spatial variation effects should be included in the analysis and design of effective vibration control systems. The control of CSBs represents a challenging and unique problem, with many complexities in modeling, control design and implementation, since the control system should be designed not only to mitigate the dynamic component of the structural response but also to counteract the effects of the pseudo-static component of the response. The spatial variability effects on the feasibility and efficiency of seismic control systems for the vibration control of CSBs are investigated in this paper. The assumption of uniform earthquake motion along the entire bridge may result in quantitative and qualitative differences in seismic response as compared with those produced by uniform motion at all supports. A systematic comparison of passive and active system performance in reducing the structural responses is performed, focusing on the effect of the spatially varying earthquake ground motion on the seismic response of a benchmark CSB model with different control strategies, and demonstrates the importance of accounting for the spatial variability of excitations. 展开更多
关键词 cable-stayed bridge vibration control earthquake spatial variation seismic design semi-active control
下载PDF
Optimization of Dead Load State in Earth-Anchored Cable-Stayed Bridges 被引量:4
7
作者 Bin Sun Rucheng Xiao 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第3期87-94,共8页
In order to determine the reasonable completed dead load state in earth-anchored cable-stayed bridges,a practical method is proposed. The method is based on the rigidly supported continuous beam method and the feasibl... In order to determine the reasonable completed dead load state in earth-anchored cable-stayed bridges,a practical method is proposed. The method is based on the rigidly supported continuous beam method and the feasible zone method,emphasizing on the mutual effect between the self-anchored structural parts and the earth-anchored ones. Three cable-stayed bridge models are designed with the main spans of 1 400 m,including a partially earth-anchored cable-stayed bridge,a cable-stayed-suspension bridge and a fully selfanchored cable-stayed bridge,in which the C50 concrete and Q345 steel are adopted. The partially earthanchored cable-stayed bridge and the cable-stayed-suspension bridge secure lower compressive force in the girder than the fully self-anchored cable-stayed bridge by 25 percent at least. The same is for the material consumption of the whole bridge. Furthermore,the anchor volume is more than 20% lower in the partially earthanchored cable-stayed bridge than that in the cable-stayed-suspension bridge. Consequently,the practical span of cable-stayed bridges can be accordingly extended. 展开更多
关键词 cable-stayed bridge partially earth-anchored cable-stayed bridge cable-stayed-suspension bridge REASONABLE completed dead load STATE
下载PDF
Comparative Study on Structural Redundancy of Cable-Stayed and Extradosed Bridges Through Safety Assessment of Their Stay Cables 被引量:5
8
作者 Khawaja Ali Hiroshi Katsuchi Hitoshi Yamada 《Engineering》 SCIE EI 2021年第1期111-123,共13页
This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use... This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use of inclined cables;however,the international standards for bridge design stipulate different safety factors for stay cables of both types of bridges.To address this misconception,a comparative study was carried out on the safety factors of stay cables under fatigue and ultimate limit states by considering the effects of various untoward and damaging factors,such as overloading,cable loss,and corrosion.The primary goal of this study is to describe the structural disparities between both types of bridges and evaluate their structural redundancies by employing deterministic and nondeterministic methods.To achieve this goal,three-dimensional finite-element models of both bridges were developed based on the current design guidelines for stay cables in Japan.After the balanced states of the bridge models were achieved,static analyses were performed for different safety factors of stay cables in a parametric manner.Finally,the first-order reliability method and Monte Carlo method were applied to determine the reliability index of stay cables.The analysis results show that cable-stayed and extradosed bridges exhibit different structural redundancies for different safety factors under the same loading conditions.Moreover,a significant increase in structural redundancy occurs with an incremental increase in the safety factors of stay cables. 展开更多
关键词 cable-stayed bridge Extradosed bridge REDUNDANCY Stay cable Safety factor Reliability analysis
下载PDF
Infl uence of structural parameters on dynamic characteristics and wind-induced buffeting responses of a super-long-span cable-stayed bridge 被引量:5
9
作者 Wang Hao Chen Chunchao +1 位作者 Xing Chenxi Li Aiqun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第3期389-399,共11页
A 3D finite element (FE) model for the Sutong cable-stayed bridge (SCB) is established based on ANSYS. The dynamic characteristics of the bridge are analyzed using a subspace iteration method. Based on recorded wi... A 3D finite element (FE) model for the Sutong cable-stayed bridge (SCB) is established based on ANSYS. The dynamic characteristics of the bridge are analyzed using a subspace iteration method. Based on recorded wind data, the measured spectra expression is presented using the nonlinear least-squares regression method. Turbulent winds at the bridge site are simulated based on the spectral representation method and the FFT technique. The influence of some key structural parameters and measures on the dynamic characteristics of the bridge are investigated. These parameters include dead load intensity, as well as vertical, lateral and torsional stiffness of the steel box girder. In addition, the influence of elastic stiffness of the connection device employed between the towers and the girder on the vibration mode of the steel box girder is investigated. The analysis shows that all of the vertical, lateral and torsional buffeting displacement responses reduce gradually as the dead load intensity increases. The dynamic characteristics and the structural buffeting displacement response of the SCB are only slightly affected by the vertical and torsional stiffness of the steel box girder, and the lateral and torsional buffeting displacement responses reduce gradually as the lateral stiffness increases. These results provide a reference for dynamic analysis and design of super-long-span cable-stayed bridges. 展开更多
关键词 cable-stayed bridge dynamic characteristics finite element (FE) method wind field simulation buffetingresponse parameter effects elastic connection device
下载PDF
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations——I:Theory 被引量:4
10
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第3期295-306,共12页
In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limita... In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limitations for installing the control device in the tower and the effect of varying natural frequency of the towers during construction. First, the finite element model of the bridge during its construction and the basic equation of motion of the MSPMD are introduced. The equation of motion of the bridge with the MSPMD under along-wind excitation is then established. Finally, a numerical simulation and parametric study are conducted to assess the effectiveness of the control system for reducing the wind-induced vibration of the bridge towers during construction. The numerical simulation results show that the MSPMD is practical and effective for reducing the along-wind response of the single column tower, can be installed in a small area of the tower, and complies with the time-variant characteristics of the bridge during its entire construction stage. 展开更多
关键词 multi-stage pendulum mass damper cable-stayed bridge single column tower wind-induced vibration
下载PDF
Analysis on Deflection Characteristics of Steel Cable-Stayed Bridge 被引量:2
11
作者 Liu Xiaoling Huang Qiao Ren Yuan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第5期890-895,共6页
Various kinds of deflection characteristics on the steel cable-stayed bridge(Nanjing No.3 Yangtze River Bridge)are investigated by different mathematical statistical methods.Firstly,via Pearson correlation coefficient... Various kinds of deflection characteristics on the steel cable-stayed bridge(Nanjing No.3 Yangtze River Bridge)are investigated by different mathematical statistical methods.Firstly,via Pearson correlation coefficient calculation,it shows good consistency between the adjacent measuring point of side span or middle span.Secondly,taking mid-span deflection as an example,the correlation analysis of deflection and temperature is conducted.They are synchronous via cross correlation coefficient calculation but not completely linear and a"hysteresis loop"phenomenon of three stages is formed.The fitting result on the monitoring data at day time is consistent with the numerical value through the application of unit temperature difference between the cable and girder and the positive temperature gradient of girder in the finite element model.And the temperature effect is considerable.Vehicle loads effect is obtained from wavelet analysis.The extracted curve can indirectly reflect the change of traffic loads.Finally,the structural damage is analyzed through the trend fusion on the deflection,cable force and visual inspection from 2006 to 2015.Relevant conclusions can provide a basis for management departments to carry out special detection. 展开更多
关键词 steel cable-stayed bridge HEALTH monitoring DEFLECTION CHARACTERISTICS ANALYSIS
下载PDF
A simplified design method for metallic dampers used in the transverse direction of cable-stayed bridges 被引量:2
12
作者 Niu Jiantao Ding Yang +1 位作者 Shi Yundong Li Zhongxian 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第2期483-497,共15页
The aseismic design of cable-stayed bridges in the transverse direction with newly proposed metallic dampers that can accommodate both longitudinal and transverse movement of the deck has recently been considered.This... The aseismic design of cable-stayed bridges in the transverse direction with newly proposed metallic dampers that can accommodate both longitudinal and transverse movement of the deck has recently been considered.This work focuses on developing a simplified method to design an appropriate metallic damper.The seismic performance of cablestayed bridges with different damper stiffness,main span lengths,tower shapes and types of deck in the transverse direction are investigated.The transverse displacement of the deck of a cable-stayed bridge increases significantly with the increment of the damper stiffness,which proves that the design of the damper stiffness is crucial.A simplified model considering the damper stiffness,cable system and tower in the transverse direction is developed to evaluate the period and lateral displacement of a complicated cable-stayed bridge.Based on the simplified model,a design method is proposed and assessed using two cable-stayed bridges as examples.The results show that metallic dampers can be designed with high efficiency,and the optimal ductility of the damper can be selected. 展开更多
关键词 cable-stayed bridge aseismic design simplified model METALLIC DAMPER TRANSVERSE direction
下载PDF
Dynamic Characteristics Evaluation of Innovative UHPC Pedestrian Cable Stayed Bridge 被引量:5
13
作者 Won Jong Chin Young Jin Kim +1 位作者 Jeong-Rae Cho Jong Sup Park 《Engineering(科研)》 2012年第12期869-876,共8页
KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and... KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and main- tenance costs of long-span bridges by 20% and double their lifetime through the exploitation of ultra-high performance concrete (UHPC). This paper presents the design and construction of the first pedestrian cable stayed bridge using UHPC developed by KICT. UHPC, compared to conventional concrete, has not only high compressive and tensile strengths but also high ductility. The UHPC developed at KICT is a steel fiber-reinforced cement compound presenting design compressive strength larger than 180 MPa and design tensile strength exceeding 10 MPa with water-to-binder ratio below 0.24 and admixing of 2 volume percentage of steel fiber. To show the applicability of UHPC to structures, a pedestrian cable stayed bridge (Super Bridge I) exploiting the characteristics of the developed UHPC has been planned, designed and erected at KICT. The dimension of UHPC deck is 2.7 m × 7 m as a precast segment with a typical thickness of deck of only 7 cm. However, harmful crack was observed in the deck at the time of the fabrication of the deck segments. Accordingly, new fabrication method was conceived and applied to prevent cracking of the UHPC slender deck. Four UHPC deck segments were fabricated successfully without any crack. After construction, the dynamic characteristics (natural frequencies and mode shapes) were evaluated through vibration tests since several users felt excess vibration. A vertical tuned mass damper (TMD) was proposed and installed on the parapet of the bridge. The TMD reduces the acceleration by about 30% from 0.0316 g to 0.0244 g when two pedestrians are crossing the bridge. 展开更多
关键词 UHPC pedestrian CABLE Stayed bridge Dynamic Characteristics Test TMD
下载PDF
Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge 被引量:5
14
作者 蒲黔辉 白光亮 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期95-101,共7页
Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure... Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load. 展开更多
关键词 Stud connector Experimental research Steel-concrete composite structure cable-stayed bridge Internal force distribution
下载PDF
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations—Ⅱ: Experiment 被引量:2
15
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第4期417-424,共8页
The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this... The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this work. In this paper, the performance of the MSPMD for reducing bridge tower vibration is studied experimentally. A MSPMD model and a tower model of the bridge with geometry scaling of 1:100 were designed and manufactured. Calibration of the MSPMD model with different wire lengths is conducted to verify the analytical model of the damper. A series of tests for the uncontrolled freestanding tower, tower with cables, and tower with MSPMD model are then performed under harmonic and white noise excitations. The experimental results show that the responses of the tower model significantly decrease with the installation of the MSPMD model, which demonstrates the effectiveness of the M SPMD to mitigate the vibration of the bridge tower. 展开更多
关键词 experimental study cable-stayed bridge single column tower multi-stage pendulum mass damper vibration control
下载PDF
Proposing a New Model of Hangers in Pedestrian Suspension Bridges to Solve Hangers Slackness Problem 被引量:3
16
作者 Majid Barghian Hadi Moghadasi Faridani 《Engineering(科研)》 2011年第4期322-330,共9页
The hangers of suspension bridges can be placed in two forms: vertical or inclined form. Inclined hangers are more liable to fatigue. Vertical hangers are subjected to greater fluctuations of stress resulting from bri... The hangers of suspension bridges can be placed in two forms: vertical or inclined form. Inclined hangers are more liable to fatigue. Vertical hangers are subjected to greater fluctuations of stress resulting from bridge wind loads. To improve aerodynamic stability, inclined hangers can be used instead of vertical ones. Some inclined hangers show considerable signs of distress and some of them show slackness due to their location against loads. In this paper a pedestrian suspension bridge with vertical hangers has been studied as a case study. Then, the same bridge has been studied with inclined hangers. To reduce internal forces, fatigue and slackness in hangers, horizontal cables have been added to inclined hangers. This modification is proposed by the present authors. The added horizontal cables transfer the tensile load from overstressed hangers to adjacent slacked hangers. Three different hanger patterns have been analyzed under nonlinear static analysis for symmetrical and nonsymmetrical live load plus dead load. Results showed that the modified hanger system had been improved considerably in comparison with vertical or inclined hangers and wherever that there is no improvement some solutions have been proposed. 展开更多
关键词 pedestrian SUSPENSION bridge Vertical Hangers Inclined Hangers Modified Hangers (Suspenders) Nonlinear STATIC SLACKNESS
下载PDF
Conceptual Design of Hybrid Cable-Stayed Bridge with Central Span of 1000 m Using UHPC 被引量:3
17
作者 Hyejin Yoon Won Jong Chin +2 位作者 Hee Seok Kim Moon Seoung Keum Young Jin Kim 《Engineering(科研)》 2013年第9期744-750,共7页
Ultra-high performance concrete (UHPC) is featured by a compressive strength 5 times higher than that of ordinary concrete and by a high durability owing to the control of the chloride penetration speed by its dense s... Ultra-high performance concrete (UHPC) is featured by a compressive strength 5 times higher than that of ordinary concrete and by a high durability owing to the control of the chloride penetration speed by its dense structure. The high strength characteristics of UHPC offer numerous advantages like the reduction of the quantities of cables and foundations by the design of a lightweight superstructure in the case of the long-span bridge preserving its structural performance through axial forces and structures governed by compression. This study conducted the conceptual design of a hybrid cable-stayed bridge with central span of 1000 m and exploiting 200 MPa-class UHPC. The economic efficiency of the conceptual design results of the hybrid cable-stayed bridge with central span of 1000 m and of Sutong Bridge, the longest cable-stayed bridge in the world, was analyzed. 展开更多
关键词 Ultra-High Performance Concrete UHPC cable-stayed bridge 200 MPa-Class Sutong bridge
下载PDF
Study of Nonlinear Seismic Response and TMD Primary Control of the Cable-Stayed Bridge Section of the Third Macao-Taipa Bridge 被引量:1
18
作者 LongXiaohong LiLi 《Journal of China University of Geosciences》 SCIE CSCD 2004年第4期409-415,共7页
The practical design of the cable-stayed bridge of the 3rd Macao-Taipa bridge is investigated by the finite element analysis program ANSYS, and 3-D elements BEAM188 and BEAM4 are adopted to create a dynamic calculati... The practical design of the cable-stayed bridge of the 3rd Macao-Taipa bridge is investigated by the finite element analysis program ANSYS, and 3-D elements BEAM188 and BEAM4 are adopted to create a dynamic calculation model. In order to analyze the material nonlinear seismic response of the cable-stayed bridge, the nonlinear behaviors of the ductile plastic hinges of the bridge towers are taken into account by employing the nonlinear rotational spring element COMBIN40. To simulate a major earthquake, three earthquake records were chosen using a wave-choosing program and input into the bridge structure along longitudinal and transversal directions. Comparisons of the linear and nonlinear seismic responses of the cable-stayed bridge are performed. In addition, a study of TMD primary control is carried out using element MASS21 and element COMBIN14, and it is indicated that the effects of mitigation monitoring are evident. 展开更多
关键词 cable-stayed bridge time-history analysis method nonlinear seismic response TMD primary control.
下载PDF
Wavelet-Based Nonstationary Wind Speed Model in Dongting Lake Cable-Stayed Bridge 被引量:3
19
作者 Xuhui He Jun Fang +1 位作者 Andrew Scanlon Zhengqing Chen 《Engineering(科研)》 2010年第11期895-903,共9页
The wind-rain induced vibration phenomena in the Dongting Lake Bridge (DLB) can be observed every year, and the field measurements of wind speed data of the bridge are usually nonstationary. Nonstationary wind speed c... The wind-rain induced vibration phenomena in the Dongting Lake Bridge (DLB) can be observed every year, and the field measurements of wind speed data of the bridge are usually nonstationary. Nonstationary wind speed can be decomposed into a deterministic time-varying mean wind speed and a zero-mean stationary fluctuating wind speed component. By using wavelet transform (WT), the time-varying mean wind speed is extracted and a nonstationary wind speed model is proposed in this paper. The wind characteristics of turbulence intensity, integral scale and probability distribution of the bridge are calculated from the typical wind samples recorded by the two anemometers installed on the DLB using the proposed nonstationary wind speed model based on WT. The calculated results are compared with those calculated by the empirical mode decomposition (EMD) and traditional approaches. The compared results indicate that the wavelet-based nonstationary wind speed model is more reasonable and appropriate than the EMD-based nonstationary and traditional stationary models for characterizing wind speed in analysis of wind-rain-induced vibration of cables. 展开更多
关键词 TIME-VARYING Mean WIND SPEED NONSTATIONARY WIND SPEED Model cable-stayed bridge Wavelet Transform (WT) WIND Characteristic Wind-Rain-Induced Vibration
下载PDF
Damage Detection for Long-Span Cable-Stayed Bridge 被引量:1
20
作者 赵玲 李爱群 +1 位作者 缪长青 汪永兰 《Journal of Southwest Jiaotong University(English Edition)》 2006年第1期63-72,共10页
Based on the updated finite-element model of a cable-stayed bridge, this study investigates the technique of identifying damage existing in cable or girder by means of numerical simulation. The modal analysis is perfo... Based on the updated finite-element model of a cable-stayed bridge, this study investigates the technique of identifying damage existing in cable or girder by means of numerical simulation. The modal analysis is performed to identify the changes in modal fiequencies and curvatures caused by damage, and the static analysis is executed to detect the influence of damage on cable force. The results indicate a relatively significant decrease in frequencies of lower vertical bending modes due to the damage in cable and little change of frequencies due to damage in girder. Different sensitivities to the location of damaged cable are observed from the fiequency changes of different bending modes, which can be used to initially locate the damaged cable. The damage in either cable or girder can be further localized by the most significant change in curvature of girder. The damage occurred in a cable produces a remarkable change in force of nearby cables, whereas the damage in girder brings little change of cable forces. In addition, a pragmatic approach for localizing the damage in girder or cable is proposed based on a comprehensive utilization of the changes in frequency of vertical bending modes, modal curvature of girder, and force in cables. 展开更多
关键词 cable-stayed bridge Cable damage Girder damage Modal curvature Cable force
下载PDF
上一页 1 2 31 下一页 到第
使用帮助 返回顶部