The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam,...X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam, mechanical and background vibration, the actual accuracy will inevitably be degraded by these time-dependent fluctuations. Therefore,not only spatial position, but also temporal features of the speckle patterns need to be considered in order to maintain the superiority of the speckle-based methods. In this paper, we propose a parallel acquisition method with advantages of real time and high accuracy, which has potential applicability to dynamic samples imaging as well as on-line beam monitoring.Through simulations, we demonstrate that the proposed method can reduce the phase error caused by the fluctuations to1% at most compared with current speckle tracking methods. Meanwhile, it can keep the accuracy deterioration within0.03 nrad, making the high theoretical accuracy a reality. Also, we find that waveforms of the incident beam have a little impact on the phase retrieved and will not influence the actual accuracy, which relaxes the requirements for speckle-based experiments.展开更多
We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microsco...We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging.展开更多
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa...X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.展开更多
A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a stro...A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified.展开更多
In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of...In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.展开更多
A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1)....A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1). The time resolution reaches 2 μs. A 10.6 μm CO_2 laser is expanded to a beam with a diameter of 30 mm and injected into the plasma as an incident beam,injecting into plasma. The emerging scattered and unscattered beams are contrasted by a phase plate. The ideas of optical path design are presented in this paper, together with the parameters of the main optical components. The whole optical path of PCI is not only carefully designed, but also constructed on HL-2 A. First calibration results show the ability of this system to catch plasma turbulence in a wide frequency domain.展开更多
System validation and density fluctuation calibration of phase contrast imaging(PCI) on an HL-2 A tokamak are presented. Signals from different channels show not only a pronounced modulation of an incident laser beam ...System validation and density fluctuation calibration of phase contrast imaging(PCI) on an HL-2 A tokamak are presented. Signals from different channels show not only a pronounced modulation of an incident laser beam induced by a sound wave, but also an excellent magnification and low image distortion of optics. The frequencywavenumber spectrum is achieved by using two-dimensional Fourier transform of time series signals. The conversion coefficient between detected signal amplitude and chord integral plasma density fluctuation is 2.35 × 1013m-2/mV, which promises a suitable signal level at the order of volts of the PCI in typical HL-2 A discharges.展开更多
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens...In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging.展开更多
Compared with the conventional X-ray absorption imaging, the X-ray phase-contrast imaging shows higher contrast on samples with low attenuation coefficient like blood vessels and soft tissues. Among the modalities of ...Compared with the conventional X-ray absorption imaging, the X-ray phase-contrast imaging shows higher contrast on samples with low attenuation coefficient like blood vessels and soft tissues. Among the modalities of phase-contrast imaging, the grating-based phase contrast imaging has been widely accepted owing to the advantage of wide range of sample selections and exemption of coherent source. However, the downside is the substantially larger amount of data generated from the phase-stepping method which slows down the reconstruction process. Graphic processing unit(GPU) has the advantage of allowing parallel computing which is very useful for large quantity data processing. In this paper, a compute unified device architecture(CUDA) C program based on GPU is introduced to accelerate the phase retrieval and filtered back projection(FBP) algorithm for grating-based tomography. Depending on the size of the data, the CUDA C program shows different amount of speed-up over the standard C program on the same Visual Studio 2010 platform. Meanwhile, the speed-up ratio increases as the size of data increases.展开更多
The wavefront shaping based technique has been introduced to detect the edges of amplitude objects through complex media,but the extraction of the boundary information of invisible phase objects through complex media ...The wavefront shaping based technique has been introduced to detect the edges of amplitude objects through complex media,but the extraction of the boundary information of invisible phase objects through complex media has not been demonstrated yet.Here,we present a phase contrast imaging technique to overcome the scattering,aiming to achieve the edge detection of the phase object through the complex media.An operator based on the experimentally measured transmission matrix is obtained by numerically adding a spiral phase in the Fourier domain.With the inverse of the filtered transmission matrix,we can directly reconstruct the edge enhanced images for both amplitude object and phase object beyond scattering.Experimentally,both digital and real objects are imaged,and the results verify that isotropic edge detection can be achieved with our technique.Our work could benefit the detection of invisible phase objects through complex media.展开更多
A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imagin...A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imaging and the improved image contrast.By using this theory,several key parameters of phase contrast imaging can be predicted,for instance,the fringe visibility and period,and the conversion condition from the differential phase imaging(DPI)to the phase difference imaging(PDI).Additionally,numerical simulations are performed with certain x-ray optical components and imaging geometry.Comparison with the available experimental measurement[Appl.Phys.Lett.113063105(2018)]demonstrates the accuracy of this developed quantitative analysis method of x-ray phase-sensitive microscope imaging.展开更多
Non-interferometric X-ray quantitative phase imaging(XQPI),much simpler than the interferometric scheme,has provided high-resolution and reliable phase-contrast images.We report on implementing the volumetric XQPI ima...Non-interferometric X-ray quantitative phase imaging(XQPI),much simpler than the interferometric scheme,has provided high-resolution and reliable phase-contrast images.We report on implementing the volumetric XQPI images using concurrent-bidirectional scanning of the orthogonal plane on the optical axis of the Foucault differential filter;we then extracted data in conjunction with the transport-intensity equation.The volumetric image of the laminate microstructure of the gills of a fish was successfully reconstructed to demonstrate our XQPI method.The method can perform 3D rendering without any rotational motion for laterally extended objects by manipulating incoherent X-rays using the pinhole array.展开更多
Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different...Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.展开更多
Phase contrast imaging technique has been improved promptly in recent years. Among these techniques in-line phase-contrast imaging is widely used. Various algorithms for in-line phase retrieval have been proposed so f...Phase contrast imaging technique has been improved promptly in recent years. Among these techniques in-line phase-contrast imaging is widely used. Various algorithms for in-line phase retrieval have been proposed so far such as TIE(transport of intensity equation), CTF(contrast transfer function), first born-approximations, GSF(Gerchberg-Saxton-Fienup), etc. Bronnikov's algorithm(BA) is a type of linear algorithm that is simple and efficient. But it can only be used without absorption situations. In this paper, an improved algorithm based on BA was presented. The approach adds Δφ(x,y) to the phase map φ_b(x,y) retrieved by BA to make the reconstructed phase map more precise. Further, the approach was evaluated on simulated images and confirmed to be accurate at higher absorption rates.展开更多
TRISO (tristructural-isotropic) fuel is a type of micro fuel particles used in high-temperature gas-cooled reactors (HTGRs). Among the quality evaluation methods for such particles, inqine phase contrast imaging t...TRISO (tristructural-isotropic) fuel is a type of micro fuel particles used in high-temperature gas-cooled reactors (HTGRs). Among the quality evaluation methods for such particles, inqine phase contrast imaging technique (PCI) is more feasible for nondestructive measurement. Due to imaging hardware limitations, high noise level is a distinct feature of PCI images, and as a result, the dimensional measurement accuracy of TRISO-coated fuel particles decreases. Therefore, we propose an improved denoising hybrid model named as NL P-M model which introduces non-local theory and retains the merits of the Perona-Malik (P-M) model. The improved model is applied to numerical simulation and practical PCI images. Quanti- tative analysis proves that this new anisotropic diffusion model can preserve edge or texture information effectively, while ruling out noise and distinctly decreasing staircasing artifacts. Especially during the process of coating layer thickness measurement, the NL P-M model makes it easy to obtain continuous contours without noisy points or fake contour segments, thus enhancing the measurement accuracy. To address calculation complexity, a graphic processing unit (GPU) is adopted to realize the acceleration of the NL P-M denoising.展开更多
X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low- Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) ite...X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low- Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging (DEI-CT). An Ordered Subsets (OS) technique is used to accelerate the ART reconstruction. Few-view reconstruction is also studied, and a partial differential equation (PDE) type filter which has the ability of edge-preserving and denoising is used to improve the image quality and eliminate the artifacts. The proposed algorithm is validated with both the numerical simulations and the experiment at the Beijing synchrotron radiation facility (BSRF).展开更多
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
基金supported by the National Natural Science Foundation of China (Grant Nos. 11675253 and 11505278)。
文摘X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam, mechanical and background vibration, the actual accuracy will inevitably be degraded by these time-dependent fluctuations. Therefore,not only spatial position, but also temporal features of the speckle patterns need to be considered in order to maintain the superiority of the speckle-based methods. In this paper, we propose a parallel acquisition method with advantages of real time and high accuracy, which has potential applicability to dynamic samples imaging as well as on-line beam monitoring.Through simulations, we demonstrate that the proposed method can reduce the phase error caused by the fluctuations to1% at most compared with current speckle tracking methods. Meanwhile, it can keep the accuracy deterioration within0.03 nrad, making the high theoretical accuracy a reality. Also, we find that waveforms of the incident beam have a little impact on the phase retrieved and will not influence the actual accuracy, which relaxes the requirements for speckle-based experiments.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11174019,61322509 and 11121091the National Basic Research Program of China under Grant No 2013CB921904
文摘We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging.
基金supported by the National Natural Science Foundation of China(Grant Nos.11275204,11475175,and 11405175)the China Postdoctoral Science Foundation(Grant No.2017M612097)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)
文摘X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61101175,61571305,and 61227802)
文摘A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11074172 and 11674232)the National Key Basic Research Program,China(Grant No.2012CB825804)the National Special Foundation for Major Science Instrument,China(Grant No.61227802)
文摘In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.
基金supported by the National Magnetic Confinement Fusion Energy Research Project(Grant Nos.2015GB120002,2013GB107000,2012GB101001)National Natural Science Foundation of China(Grant Nos.11375053,11535013)the Natural Science Foundation of Anhui Province(Grant No.1608085MA08)
文摘A phase contrast imaging(PCI) diagnostic has recently been developed on HL-2 A tokamak. It can diagnose plasma density fluctuations with maximum wave number of 15 cm^(-1) and wave number resolution of 2 cm^(-1). The time resolution reaches 2 μs. A 10.6 μm CO_2 laser is expanded to a beam with a diameter of 30 mm and injected into the plasma as an incident beam,injecting into plasma. The emerging scattered and unscattered beams are contrasted by a phase plate. The ideas of optical path design are presented in this paper, together with the parameters of the main optical components. The whole optical path of PCI is not only carefully designed, but also constructed on HL-2 A. First calibration results show the ability of this system to catch plasma turbulence in a wide frequency domain.
基金supported by the National Magnetic Confinement Fusion Energy Research Project(No.2015GB120002)the National Key Research and Development Program of China(No.2017YFE0300405)the National Natural Science Foundation of China(Nos.11705052,11575055,and 11611130164)
文摘System validation and density fluctuation calibration of phase contrast imaging(PCI) on an HL-2 A tokamak are presented. Signals from different channels show not only a pronounced modulation of an incident laser beam induced by a sound wave, but also an excellent magnification and low image distortion of optics. The frequencywavenumber spectrum is achieved by using two-dimensional Fourier transform of time series signals. The conversion coefficient between detected signal amplitude and chord integral plasma density fluctuation is 2.35 × 1013m-2/mV, which promises a suitable signal level at the order of volts of the PCI in typical HL-2 A discharges.
基金Project supported by the National Natural Science Foundation of China (Grant No 10475044).
文摘In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging.
基金the National Basic Research Program(973) of China(No.2010CB834300)the Biomedical Engineering Cross-Research Fund of Shanghai Jiao Tong University(Nos.YG2011MS49 and YG2013MS65)
文摘Compared with the conventional X-ray absorption imaging, the X-ray phase-contrast imaging shows higher contrast on samples with low attenuation coefficient like blood vessels and soft tissues. Among the modalities of phase-contrast imaging, the grating-based phase contrast imaging has been widely accepted owing to the advantage of wide range of sample selections and exemption of coherent source. However, the downside is the substantially larger amount of data generated from the phase-stepping method which slows down the reconstruction process. Graphic processing unit(GPU) has the advantage of allowing parallel computing which is very useful for large quantity data processing. In this paper, a compute unified device architecture(CUDA) C program based on GPU is introduced to accelerate the phase retrieval and filtered back projection(FBP) algorithm for grating-based tomography. Depending on the size of the data, the CUDA C program shows different amount of speed-up over the standard C program on the same Visual Studio 2010 platform. Meanwhile, the speed-up ratio increases as the size of data increases.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFA0705000)the National Natural Science Foundation of China(NSFC)(Nos.12004219,120742251,2192254,91750201,and 11974218)+1 种基金the Innovation Group of Jinan(No.2018GXRC010)the Local Science and Technology Development Project of the Central Government(No.YDZX20203700001766).
文摘The wavefront shaping based technique has been introduced to detect the edges of amplitude objects through complex media,but the extraction of the boundary information of invisible phase objects through complex media has not been demonstrated yet.Here,we present a phase contrast imaging technique to overcome the scattering,aiming to achieve the edge detection of the phase object through the complex media.An operator based on the experimentally measured transmission matrix is obtained by numerically adding a spiral phase in the Fourier domain.With the inverse of the filtered transmission matrix,we can directly reconstruct the edge enhanced images for both amplitude object and phase object beyond scattering.Experimentally,both digital and real objects are imaged,and the results verify that isotropic edge detection can be achieved with our technique.Our work could benefit the detection of invisible phase objects through complex media.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.12027812 and 11804356)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(Grant No.2021362).
文摘A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imaging and the improved image contrast.By using this theory,several key parameters of phase contrast imaging can be predicted,for instance,the fringe visibility and period,and the conversion condition from the differential phase imaging(DPI)to the phase difference imaging(PDI).Additionally,numerical simulations are performed with certain x-ray optical components and imaging geometry.Comparison with the available experimental measurement[Appl.Phys.Lett.113063105(2018)]demonstrates the accuracy of this developed quantitative analysis method of x-ray phase-sensitive microscope imaging.
基金supported by the National Research Foundation of Korea(NRF)funded by the Korean government(MEST)(No.2021R1C1C200514).
文摘Non-interferometric X-ray quantitative phase imaging(XQPI),much simpler than the interferometric scheme,has provided high-resolution and reliable phase-contrast images.We report on implementing the volumetric XQPI images using concurrent-bidirectional scanning of the orthogonal plane on the optical axis of the Foucault differential filter;we then extracted data in conjunction with the transport-intensity equation.The volumetric image of the laminate microstructure of the gills of a fish was successfully reconstructed to demonstrate our XQPI method.The method can perform 3D rendering without any rotational motion for laterally extended objects by manipulating incoherent X-rays using the pinhole array.
基金Supported by the National Natural Science Foundation of China (10475090)
文摘Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.
基金Shanghai Synchrotron Radiation Facility(SSRF)National Natural Science Foundation of China+4 种基金grant number:NSFC11005074 and NSFC50725622Doctoral Fund of Ministry of Education of Chinagrant number:20100073120004National Basic Research Program of Chinagrant number:2010CB834300
文摘Phase contrast imaging technique has been improved promptly in recent years. Among these techniques in-line phase-contrast imaging is widely used. Various algorithms for in-line phase retrieval have been proposed so far such as TIE(transport of intensity equation), CTF(contrast transfer function), first born-approximations, GSF(Gerchberg-Saxton-Fienup), etc. Bronnikov's algorithm(BA) is a type of linear algorithm that is simple and efficient. But it can only be used without absorption situations. In this paper, an improved algorithm based on BA was presented. The approach adds Δφ(x,y) to the phase map φ_b(x,y) retrieved by BA to make the reconstructed phase map more precise. Further, the approach was evaluated on simulated images and confirmed to be accurate at higher absorption rates.
基金supported in part by the National Natural Science Foundation of China(NSFC)under Grants 11275019,21106158 and 61077011in part by the National State Key Laboratory of Multiphase Complex Systems under Grant MPCS-2011-D-03+4 种基金in part by the National Key Technology R&D Program of China under Grant 2011 BAI02B02supported in part by the National Research Foundation of Korea(NRF)grantfunded by the Korean government(MEST)(No.2011-0020024)in part by the R&D program of the Korea Institute of Energy Technology Evaluation and Planning(KETEP)grant funded by the Korean government Ministry of Knowledge Economy(No.20101020300730)the Defense Acquisition Program Administration and the Agency for Defense Development for the financial support provided by both institutions
文摘TRISO (tristructural-isotropic) fuel is a type of micro fuel particles used in high-temperature gas-cooled reactors (HTGRs). Among the quality evaluation methods for such particles, inqine phase contrast imaging technique (PCI) is more feasible for nondestructive measurement. Due to imaging hardware limitations, high noise level is a distinct feature of PCI images, and as a result, the dimensional measurement accuracy of TRISO-coated fuel particles decreases. Therefore, we propose an improved denoising hybrid model named as NL P-M model which introduces non-local theory and retains the merits of the Perona-Malik (P-M) model. The improved model is applied to numerical simulation and practical PCI images. Quanti- tative analysis proves that this new anisotropic diffusion model can preserve edge or texture information effectively, while ruling out noise and distinctly decreasing staircasing artifacts. Especially during the process of coating layer thickness measurement, the NL P-M model makes it easy to obtain continuous contours without noisy points or fake contour segments, thus enhancing the measurement accuracy. To address calculation complexity, a graphic processing unit (GPU) is adopted to realize the acceleration of the NL P-M denoising.
基金Supported by National Natural Science Foundation of China (10875066)Program for New Century Excellent Talents in University (NCET-05-0060)
文摘X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low- Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging (DEI-CT). An Ordered Subsets (OS) technique is used to accelerate the ART reconstruction. Few-view reconstruction is also studied, and a partial differential equation (PDE) type filter which has the ability of edge-preserving and denoising is used to improve the image quality and eliminate the artifacts. The proposed algorithm is validated with both the numerical simulations and the experiment at the Beijing synchrotron radiation facility (BSRF).