The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ...The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.展开更多
Beam signals captured from a button-type pickup contain multidimensional information including the bunch charge,transverse position,bunch length,and longitudinal phase.A bunch phase monitor,which retrieves longitudina...Beam signals captured from a button-type pickup contain multidimensional information including the bunch charge,transverse position,bunch length,and longitudinal phase.A bunch phase monitor,which retrieves longitudinal phase information from a pickup signal at a bunch-by-bunch rate,has been developed at the Shanghai Synchrotron Radiation Facility.This paper introduces the basic principles,system setup,data processing method,and preliminary experimental results of this system.The systematic measurement error introduced by the limited system bandwidth,bunch length,and bunch charge variation was studied using simulation data.The random measurement uncertainty was evaluated using experimental beam data.The experimental result shows that the longitudinal phase resolution of this system is better than 1.0 ps.The first application,measuring the relationship between the longitudinal phase and bunch charge to determine the energy loss factor,was implemented,and the preliminary result is also discussed.展开更多
文摘The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.
基金supported by the National Natural Science Foundation of China(Nos.11575282,11375255)
文摘Beam signals captured from a button-type pickup contain multidimensional information including the bunch charge,transverse position,bunch length,and longitudinal phase.A bunch phase monitor,which retrieves longitudinal phase information from a pickup signal at a bunch-by-bunch rate,has been developed at the Shanghai Synchrotron Radiation Facility.This paper introduces the basic principles,system setup,data processing method,and preliminary experimental results of this system.The systematic measurement error introduced by the limited system bandwidth,bunch length,and bunch charge variation was studied using simulation data.The random measurement uncertainty was evaluated using experimental beam data.The experimental result shows that the longitudinal phase resolution of this system is better than 1.0 ps.The first application,measuring the relationship between the longitudinal phase and bunch charge to determine the energy loss factor,was implemented,and the preliminary result is also discussed.