期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Validation of Metformin Hydrochloride in Human Plasma by HPLC-Photo Diode Array (PDA) for Application of Bioequivalence Study
1
作者 Yahdiana Harahap Krisnasari Dianpratami Mahi Wulandari Rina Rahmawati 《Journal of Life Sciences》 2012年第1期20-27,共8页
A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consis... A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other. 展开更多
关键词 Metformin HCl DIAZEPAM HPLC sodium dodecyl sulphate (SDS) photo diode array pda detector bioequivalence(BE) study.
下载PDF
H_α/ D_α Measurements Based on Photo Diode Array in the HT-7 Tokamak 被引量:1
2
作者 刘建坤 吴振伟 +2 位作者 万宝年 张先梅 周倩 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第5期997-1004,共8页
Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is conve... Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed. 展开更多
关键词 Measurements Based on Photo Diode array in the HT-7 Tokamak HT pda
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部