The effect of the circulation fan installed in fresh food compartment on energy consumption of natural convective refrigerator/freezers (RFs) was experimentally studied. Five different RF models with different cycles ...The effect of the circulation fan installed in fresh food compartment on energy consumption of natural convective refrigerator/freezers (RFs) was experimentally studied. Five different RF models with different cycles were tested. The experimental results showed that the energy consumption of the single-loop cycle RF increased by 2.4%~3.8%, that of the bypass two-circuit cycle RF decreased by 1.0%, and that of the two-circuit cycle RF with its evaporators in parallel when the geometry parameters of refrigeration system and the refrigerant charge were not changed after the circulation fan was installed decreased by 3.3%. When the optimization on the refrigerant charge and the evaporator was carried out, the energy consumption of the single-loop cycle RF , the bypass two-circuit cycle RF and the two-circuit cycle RF with its evaporators in parallel, decreased by 1.0%~6.4%, 3.25% and 3.26% respectively. The present conclusions will provide a guideline to the optimum design for the RF with the circulation fan.展开更多
为了开发高效的太阳能冷却技术,建立了一个由光伏(photovoltaic,PV)模块和基于范德华异质结构(van der Waals heterostructure,vdWH)的热离子制冷器(thermionic refrigerator,TIR)组成的新型耦合系统。在充分考虑内部和外部的不可逆因...为了开发高效的太阳能冷却技术,建立了一个由光伏(photovoltaic,PV)模块和基于范德华异质结构(van der Waals heterostructure,vdWH)的热离子制冷器(thermionic refrigerator,TIR)组成的新型耦合系统。在充分考虑内部和外部的不可逆因素的情况下,建立了耦合系统的理论模型,推导了关键性能指标的数学表达式。在此基础上,研究了耦合系统的一般性能特征,并确定了允许系统运行的电压区域。根据计算,最大制冷量和最大性能系数(coefficient of performance,COP)分别为75.88 W和0.49。此外,还进行了灵敏度分析,以得出关键参数对整体性能影响的规律和大小,包括太阳辐照度、有效肖特基势垒高度、层间热阻、外部热阻、热泄漏热阻和热库温度。所得结果可能有助于实际耦合系统的设计和运行。展开更多
文摘The effect of the circulation fan installed in fresh food compartment on energy consumption of natural convective refrigerator/freezers (RFs) was experimentally studied. Five different RF models with different cycles were tested. The experimental results showed that the energy consumption of the single-loop cycle RF increased by 2.4%~3.8%, that of the bypass two-circuit cycle RF decreased by 1.0%, and that of the two-circuit cycle RF with its evaporators in parallel when the geometry parameters of refrigeration system and the refrigerant charge were not changed after the circulation fan was installed decreased by 3.3%. When the optimization on the refrigerant charge and the evaporator was carried out, the energy consumption of the single-loop cycle RF , the bypass two-circuit cycle RF and the two-circuit cycle RF with its evaporators in parallel, decreased by 1.0%~6.4%, 3.25% and 3.26% respectively. The present conclusions will provide a guideline to the optimum design for the RF with the circulation fan.
文摘为了开发高效的太阳能冷却技术,建立了一个由光伏(photovoltaic,PV)模块和基于范德华异质结构(van der Waals heterostructure,vdWH)的热离子制冷器(thermionic refrigerator,TIR)组成的新型耦合系统。在充分考虑内部和外部的不可逆因素的情况下,建立了耦合系统的理论模型,推导了关键性能指标的数学表达式。在此基础上,研究了耦合系统的一般性能特征,并确定了允许系统运行的电压区域。根据计算,最大制冷量和最大性能系数(coefficient of performance,COP)分别为75.88 W和0.49。此外,还进行了灵敏度分析,以得出关键参数对整体性能影响的规律和大小,包括太阳辐照度、有效肖特基势垒高度、层间热阻、外部热阻、热泄漏热阻和热库温度。所得结果可能有助于实际耦合系统的设计和运行。