Indentations onto crystalline silicon and copper with various indenter geometries, loading forces at room temperature belong to the widest interests in the field, because of the physical detection of structural phase ...Indentations onto crystalline silicon and copper with various indenter geometries, loading forces at room temperature belong to the widest interests in the field, because of the physical detection of structural phase transitions. By using the mathematically deduced F<sub>N</sub>h<sup>3/2 </sup>relation for conical and pyramidal indentations we have a toolbox for deciding between faked and experimental loading curves. Four printed silicon indentation loading curves (labelled with 292 K, 260 K, 240 K and 210 K) proved to be faked and not experimental. This is problematic for the AI (artificial intelligence) that will probably not be able to sort faked data out by itself but must be told to do so. High risks arise, when published faked indentation reports remain unidentified and unreported for the mechanics engineers by reading, or via AI. For example, when AI recommends a faked quality such as “no phase changes” of a technical material that is therefore used, it might break down due to an actually present low force, low transition energy phase-change. This paper thus installed a tool box for the distinction of experimental and faked loading curves of indentations. We found experimental and faked loading curves of the same research group with overall 14 authoring co-workers in three publications where valid and faked ones were next to each other and I can thus only report on the experimental ones. The comparison of Si and Cu with W at 20-fold higher physical hardness shows its enormous influence to the energies of phase transition and of their transition energies. Thus, the commonly preferred ISO14577-ASTM hardness values HISO (these violate the energy law and are simulated!) leads to almost blind characterization and use of mechanically stressed technical materials (e.g. airplanes, windmills, bridges, etc). The reasons are carefully detected and reported to disprove that the coincidence or very close coincidence of all of the published loading curves from 150 K to 298 K are constructed but not experimental. A tool-box for distinction of experimental from faked indentation loading curves (simulations must be indicated) is established in view of protecting the AI from faked data, which it might not be able by itself to sort them out, so that technical materials with wrongly attributed mechanical properties might lead to catastrophic accidents such as all of us know of. There is also the risk that false theories might lead to discourage the design of important research projects or for not getting them granted. This might for example hamper or ill-fame new low temperature indentation projects. The various hints for identifying faked claims are thus presented in great detail. The low-temperature instrumental indentations onto silicon have been faked in two consecutive publications and their reporting in the third one, so that these are not available for the calculation of activation energies. Conversely, the same research group published an indentation loading curve of copper as taken at 150 K that could be tested for its validity with the therefore created tools of validity tests. The physical algebraic calculations provided the epochal detection of two highly exothermic phase transitions of copper that created two polymorphs with negative standard energy content. This is world-wide the second case and the first one far above the 77 K of liquid nitrogen. Its existence poses completely new thoughts for physics chemistry and perhaps techniques but all of them are open and unprepared for our comprehension. The first chemical reactions might be in-situ photolysis and the phase transitions can be calculated from experimental curves. But several further reported low temperature indentation loading curves of silicon were tested for their experimental reality. And the results are compared to new analyses with genuine room temperature results. A lot is to be learned from the differences at room and low temperature.展开更多
The process of electron beam vacuum deposition of the Fe-(35-38 wt%)Ni alloys at substrate temperatures Ts from 300 to700 ℃ were used to produce vacuum-deposited foils with the FCC structure, differing by the size ...The process of electron beam vacuum deposition of the Fe-(35-38 wt%)Ni alloys at substrate temperatures Ts from 300 to700 ℃ were used to produce vacuum-deposited foils with the FCC structure, differing by the size of characteristic microstructural elements (grains and subgrains). It was shown that refinement of foil microstructural elements to nanoscale is accompanied by their microhardness increase up to 4-5 GPa. The change of the thermal expansion coefficient (TEC) of the nanostructured (NS) foil of the Fe-35.1Ni alloy within the temperature range from -50 to 150 ℃ has some deviation from that observed for cast Invar alloy of the same composition. It has been found that the main factors affecting the peculiarities of thermal expansion of the NS foil can be related to the presence of small fraction of BCC- phase in them, high level of crystalline lattice microstrains and inhomogeneous magnetic order in FCC- phase. It was shown that as a result of additional thermal treatment of NS foils their invar properties become similar to that observed for cast Invar alloy but mechanical properties remain on the same level.展开更多
文摘Indentations onto crystalline silicon and copper with various indenter geometries, loading forces at room temperature belong to the widest interests in the field, because of the physical detection of structural phase transitions. By using the mathematically deduced F<sub>N</sub>h<sup>3/2 </sup>relation for conical and pyramidal indentations we have a toolbox for deciding between faked and experimental loading curves. Four printed silicon indentation loading curves (labelled with 292 K, 260 K, 240 K and 210 K) proved to be faked and not experimental. This is problematic for the AI (artificial intelligence) that will probably not be able to sort faked data out by itself but must be told to do so. High risks arise, when published faked indentation reports remain unidentified and unreported for the mechanics engineers by reading, or via AI. For example, when AI recommends a faked quality such as “no phase changes” of a technical material that is therefore used, it might break down due to an actually present low force, low transition energy phase-change. This paper thus installed a tool box for the distinction of experimental and faked loading curves of indentations. We found experimental and faked loading curves of the same research group with overall 14 authoring co-workers in three publications where valid and faked ones were next to each other and I can thus only report on the experimental ones. The comparison of Si and Cu with W at 20-fold higher physical hardness shows its enormous influence to the energies of phase transition and of their transition energies. Thus, the commonly preferred ISO14577-ASTM hardness values HISO (these violate the energy law and are simulated!) leads to almost blind characterization and use of mechanically stressed technical materials (e.g. airplanes, windmills, bridges, etc). The reasons are carefully detected and reported to disprove that the coincidence or very close coincidence of all of the published loading curves from 150 K to 298 K are constructed but not experimental. A tool-box for distinction of experimental from faked indentation loading curves (simulations must be indicated) is established in view of protecting the AI from faked data, which it might not be able by itself to sort them out, so that technical materials with wrongly attributed mechanical properties might lead to catastrophic accidents such as all of us know of. There is also the risk that false theories might lead to discourage the design of important research projects or for not getting them granted. This might for example hamper or ill-fame new low temperature indentation projects. The various hints for identifying faked claims are thus presented in great detail. The low-temperature instrumental indentations onto silicon have been faked in two consecutive publications and their reporting in the third one, so that these are not available for the calculation of activation energies. Conversely, the same research group published an indentation loading curve of copper as taken at 150 K that could be tested for its validity with the therefore created tools of validity tests. The physical algebraic calculations provided the epochal detection of two highly exothermic phase transitions of copper that created two polymorphs with negative standard energy content. This is world-wide the second case and the first one far above the 77 K of liquid nitrogen. Its existence poses completely new thoughts for physics chemistry and perhaps techniques but all of them are open and unprepared for our comprehension. The first chemical reactions might be in-situ photolysis and the phase transitions can be calculated from experimental curves. But several further reported low temperature indentation loading curves of silicon were tested for their experimental reality. And the results are compared to new analyses with genuine room temperature results. A lot is to be learned from the differences at room and low temperature.
基金the financing support of the budget(022/11-B)of the G.V.Kurdyumov Institute for Metal Physics of NAS of Ukrainethe budget(1.6.3.13/33) of the E.O.Paton Electric Welding Institute of NAS of Ukraine
文摘The process of electron beam vacuum deposition of the Fe-(35-38 wt%)Ni alloys at substrate temperatures Ts from 300 to700 ℃ were used to produce vacuum-deposited foils with the FCC structure, differing by the size of characteristic microstructural elements (grains and subgrains). It was shown that refinement of foil microstructural elements to nanoscale is accompanied by their microhardness increase up to 4-5 GPa. The change of the thermal expansion coefficient (TEC) of the nanostructured (NS) foil of the Fe-35.1Ni alloy within the temperature range from -50 to 150 ℃ has some deviation from that observed for cast Invar alloy of the same composition. It has been found that the main factors affecting the peculiarities of thermal expansion of the NS foil can be related to the presence of small fraction of BCC- phase in them, high level of crystalline lattice microstrains and inhomogeneous magnetic order in FCC- phase. It was shown that as a result of additional thermal treatment of NS foils their invar properties become similar to that observed for cast Invar alloy but mechanical properties remain on the same level.