Nowadays,researchers are becoming increasingly concerned about developing a highly efficient emission free transportation and energy generation system for addressing the pressing issue of environmental crisis in the fo...Nowadays,researchers are becoming increasingly concerned about developing a highly efficient emission free transportation and energy generation system for addressing the pressing issue of environmental crisis in the form of pollution and climate change.The introduction of Electric Vehicles(EVs)solves the challenge of emission-free transportation while the necessity for decarbonized energy production is fulfilled by the installation and expansion of solar-powered Photovoltaic(PV)systems.Hence,this paper focuses on designing an effective PV based EV charging system that aids in stepping towards the achievement of a pollution free future.For overcoming the inherent intermittency associated with PV,a novel DC-DC converter is designed by integrating both Trans Z-source con-verter and Luo converter,which offers remarkable benefits of high conversion range,lesser voltage stress and excellent efficiency.A novel robust Lion Grey Wolf Optimized Proportional Integral(LGWO-PI)controller is designed for sig-nificantly strengthening the operation of the integrated converter in terms of peak overshoot,Total Harmonic Distortion(THD)and settling time.A 3’Voltage Source Inverter(VSI)is employed to convert the stable DC output from the PV sys-tem to AC,which is then used for driving the Brushless Direct Current Motor(BLDC)motor of EV.The speed of the BLDC is regulated using a PI controller.The BLDC motor gets the power supply from the grid during the unavailability of PV based power supply.The grid is integrated with the designed EV charging system through a 1’VSI and the process of grid voltage synchronization is carried out with the application of PI controller.The simulation for evaluating the operation of the presented EV charging system is done using MATLAB and the attained out-comes have validated that this introduced methodology delivers enhanced perfor-mance with optimal efficiency of 97.6%and lesser THD of 2.1%.展开更多
The Brushless DC Motor drive systems are used widely with renewable energy resources.The power converter controlling technique increases the performance by novel techniques and algorithms.Conventional approaches are m...The Brushless DC Motor drive systems are used widely with renewable energy resources.The power converter controlling technique increases the performance by novel techniques and algorithms.Conventional approaches are mostly focused on buck converter,Fuzzy logic control with various switching activity.In this proposed research work,the QPSO(Quantum Particle Swarm Optimization algorithm)is used on the switching state of converter from the generation unit of solar module.Through the duty cycle pulse from optimization function,the MOSFET(Metal-Oxide-Semiconductor Field-Effect Transistor)of the Boost converter gets switched when BLDC(Brushless Direct Current Motor)motor drive system requires power.Voltage Source three phase inverter and Boost converter is controlled by proportional-integral(PI)controller.Based on the BLDC drive,the load utilized from the solar generating module.Experimental results analyzed every module of the proposed grid system,which are solar generation utilizes the irradiance and temperature depends on this the Photovoltaics(PV)power is generated and the QPSO with Duty cycle switching state is determined.The Boost converter module is boost stage based on generation and load is obtained.Single Ended Primary Inductor Converter(SEPIC)and Zeta converter model is compared with the proposed logic;the proposed boost converter achieves the results.Three phase inverter control,PI,and BLDC motor drive results.Thus the proposed grid model is constructed to obtain the better performance results than most recent literatures.Overall design model is done by using MATLAB/Simulink 2020a.展开更多
Multi-port converters are considered as exceeding earlier period decade owing to function in a combination of different energy sources in a single processing unit.Renewable energy sources are playing a significant rol...Multi-port converters are considered as exceeding earlier period decade owing to function in a combination of different energy sources in a single processing unit.Renewable energy sources are playing a significant role in the modern energy system with rapid development.In renewable sources like fuel combustion and solar energy,the generated voltages change due to their environmental changes.To develop energy resources,electric power generation involved huge awareness.The power and output voltages are plays important role in our work but it not considered in the existing system.For considering the power and voltage,Gaussian PI Controller-Maxpooling Deep Convolutional Neural Network Classifier(GPIC-MDCNNC)Model is introduced for the grid-connected renewable energy system.The input information is collected from two input sources.After that,input layer transfer information to hidden layer 1 fuzzy PI is employed for controlling voltage in GPIC-MDCNNC Model.Hidden layer 1 is transferred to hidden layer 2.Gaussian activation is employed for determining the output voltage with help of the controller.At last,the output layer offers the last value in GPIC-MDCNNC Model.The designed method was confirmed using one and multiple sources by stable and unpredictable input voltages.GPIC-MDCNNC Model increases the performance of grid-connected renewable energy systems by enhanced voltage value compared with state-of-the-art works.The control technique using GPIC-MDCNNC Model increases the dynamics of hybrid energy systems connected to the grid.展开更多
This paper introduces an electrical drives control architecture combining a fractional-order controller and a setpoint pre-filter. The former is based on a fractional-order proportional-integral(PI) unit, with a non-i...This paper introduces an electrical drives control architecture combining a fractional-order controller and a setpoint pre-filter. The former is based on a fractional-order proportional-integral(PI) unit, with a non-integer order integral action, while the latter can be of integer or non-integer type. To satisfy robustness and dynamic performance specifications, the feedback controller is designed by a loop-shaping technique in the frequency domain. In particular, optimality of the feedback system is pursued to achieve input-output tracking. The setpoint pre-filter is designed by a dynamic inversion technique minimizing the difference between the ideal synthesized command signal(i.e., a smooth monotonic response) and the prefilter step response. Experimental tests validate the methodology and compare the performance of the proposed architecture with well-established control schemes that employ the classical PIbased symmetrical optimum method with a smoothing pre-filter.展开更多
In orthopaedic surgeries, permanent magnet DC motors are used to drill the bone and fix the screws. The Motor drive employs an inner current and outer speed control loop with a conventional or modern controller. To en...In orthopaedic surgeries, permanent magnet DC motors are used to drill the bone and fix the screws. The Motor drive employs an inner current and outer speed control loop with a conventional or modern controller. To enhance the performance of the drive, this paper proposes a Brain Emotional Logic Based Intelligent Controller based chopper drive. The proposed drive scheme has been simulated using Matlab/Simulink and physically realized for validation. A comparative analysis has been made between the conventional PI controller based drive and the proposed system in order to prove that the proposed scheme has an edge over the traditional PI controller scheme counterpart.展开更多
Greenhouse system (GHS) is the worldwide fastest growing phenomenon in agricultural sector. Greenhouse models are essential for improving control efficiencies. The Relative Gain Analysis (RGA) reveals that the GHS con...Greenhouse system (GHS) is the worldwide fastest growing phenomenon in agricultural sector. Greenhouse models are essential for improving control efficiencies. The Relative Gain Analysis (RGA) reveals that the GHS control is complex due to 1) high nonlinear interactions between the biological subsystem and the physical subsystem and 2) strong coupling between the process variables such as temperature and humidity. In this paper, a decoupled linear cooling model has been developed using a feedback-feed forward linearization technique. Further, based on the model developed Internal Model Control (IMC) based Proportional Integrator (PI) controller parameters are optimized using Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) to achieve minimum Integral Square Error (ISE). The closed loop control is carried out using the above control schemes for set-point change and disturbance rejection. Finally, closed loop servo and servo-regulatory responses of GHS are compared quantitatively as well as qualitatively. The results implicate that IMC based PI controller using PSO provides better performance than the IMC based PI controller using GA. Also, it is observed that the disturbance introduced in one loop will not affect the other loop due to feedback-feed forward linearization and decoupling. Such a control scheme used for GHS would result in better yield in production of crops such as tomato, lettuce and broccoli.展开更多
This paper presents a comparative study of different decoupling control schemes for a two-input, two-output(TITO) binary distillation column via proportional-integral(PI)controller. The key idea behind this paper is d...This paper presents a comparative study of different decoupling control schemes for a two-input, two-output(TITO) binary distillation column via proportional-integral(PI)controller. The key idea behind this paper is designing two novel fuzzy decoupling schemes that depend on human knowledge,instead of the system mathematical model used in conventional decoupling schemes. Based on conventional and inverted decoupling schemes, fuzzy and inverted fuzzy decoupling schemes are developed. The control effect is compared using simulation results for the proposed two schemes with conventional decoupling and inverted decoupling. The proposed fuzzy decoupling schemes are easy to realize and simple to design, besides they have a good decoupling capability. Two methods are used to prove asymptotic stability of each loop and the entire closed-loop system by applying the proposed fuzzy decoupling-based PI controller.The Wood and Berry model of a binary distillation column is used to illustrate the applicability of the proposed schemes.展开更多
The consensus problem for fractional multi-agent systems(MASs)with time delay is considered.The distributed fractional proportional-integral(PI)-type controller is designed so that the consensus of the proposed system...The consensus problem for fractional multi-agent systems(MASs)with time delay is considered.The distributed fractional proportional-integral(PI)-type controller is designed so that the consensus of the proposed systems is achieved.Moreover,explicit condition to determine the crossing directions is developed.The results show that with the increase of time delay,the closed-loop system has two different dynamic characteristics:From consensus to nonconsensus and consensus switching.Furthermore,delay margin within which consensus of MASs will always hold is determined.The results should provide useful guidelines in the consensus analysis and in the analytical design of the distributed controllers.展开更多
Open communication system in modern power systems brings concern about information staleness which may cause power system frequency instability.The information staleness is often characterized by communication delay.H...Open communication system in modern power systems brings concern about information staleness which may cause power system frequency instability.The information staleness is often characterized by communication delay.However,communication delay is a packet-centered metric and cannot reflect the requirement of information freshness for load frequency control(LFC).This paper introduces the age of information(AoI),which is more compre-hensive and informative than the conventional communication delay modeling method.An LFC controller and com-munication are integrated into the design for LFC performance improvement.An AoI-aware LFC model is formulated first,and considering each allowable update period of the smart sensor,different AoI-aware PI controllers are then designed according to the exponential decay rate.The right AoI-aware controller and update period are selected according to the degree of frequency fluctuation of the power system.Case studies are carried out on one-area and two-area power systems.The results show the superior performance of the AoI-aware controllers in comparison to the delay-dependent controllers.展开更多
Grid frequency variation causes phase angle deviation in current with respect to voltage.This is sensed at the phase-locked loop in the controller.In past studies the effect of grid frequency variation is neglected wh...Grid frequency variation causes phase angle deviation in current with respect to voltage.This is sensed at the phase-locked loop in the controller.In past studies the effect of grid frequency variation is neglected while designing the controller for power quality restoration.When modern grids are connected to large numbers of non-linear loads and various types of distributed generation(DG),it results in continuous variation in grid frequency.Thus it is necessary to consider the grid frequency variation for effective power quality restoration.However,tuning of conventional PI controller gains considering frequency variation is very difficult.Thus it is necessary to develop an adaptive intelligent nonlinear controller to tackle the effects of frequency variation,voltage distortion and non-linear load simultaneously.This paper presents the importance of considering the effects of the frequency variation,grid voltage distortion and non-linear load,while designing and deploying a controller for power quality restoration.The proposed controller supplies power to local load as well as transferring surplus power to the grid from DG along with the additional ben-efit of improving grid power quality.A DG with an ANFIS optimized PI current controller for power quality enhance-ment is proposed.The method is economical as it requires no additional hardware.Results are compared with PI,PI-RC and fuzzy current controllers to validate the effectiveness of the proposed controller.展开更多
In practical applications of dynamic DNA nanotechnology,a biomolecular controller is required for maintaining the operation of the molecular actuator at a desired condition based on the information from molecular sens...In practical applications of dynamic DNA nanotechnology,a biomolecular controller is required for maintaining the operation of the molecular actuator at a desired condition based on the information from molecular sensors.By making use of the DNA strand displacement mechanism as a"programming language"in the controller design,a biomolecular PI controller has been proposed.However,this PI control system has been verified only at the simulation level,and a theoretical regulation analysis is still required.Accordingly,in this study,we perform a rigorous regulation analysis of the biomolecular PI control system.Specifically,we theoretically prove that the output signal approaches the target level at a quasi-steady state.To this end,we apply the concept of finite-time regulation property to the biomolecular PI control system.展开更多
This paper presents an auto-tuning method for a proportion plus integral(PI) controller for permanent magnet synchronous motor(PMSM) drives, which is supposed to be embedded in electro-mechanical actuator(EMA) c...This paper presents an auto-tuning method for a proportion plus integral(PI) controller for permanent magnet synchronous motor(PMSM) drives, which is supposed to be embedded in electro-mechanical actuator(EMA) control module in aircraft. The method, based on a relay feedback with variable delay time, explores different critical points of the system frequency response.The Nyquist points of the plant can then be derived from the delay time and filter time constant.The coefficients of the PI controller can then be obtained by calculation while shifting the Nyquist point to a specific position to obtain the required phase margin. The major advantage of the autotuning method is that it can provide a series of tuning results for different system bandwidths and damping ratios, corresponding to the specification for delay time and phase margin. Simulation and experimental results for the PMSM controller verify the performance of both the current loop and the speed loop auto-tuning.展开更多
This paper is dealing with the problem of tracking control for uncertain flexible joint manipulator robots driven by brushless direct current motor(BDCM). Flexibility of joint in the manipulator constitutes one of the...This paper is dealing with the problem of tracking control for uncertain flexible joint manipulator robots driven by brushless direct current motor(BDCM). Flexibility of joint in the manipulator constitutes one of the most important sources of uncertainties. In order to achieve high performance, all parts of the manipulator including actuator have been modeled. To cancel the tracking error, a hysteresis current controller and speed controllers have been developed. To evaluate the effectiveness of speed controllers, a comparative study between proportional integral(PI) and sliding mode controllers has been performed. Finally, simulation results carried out in the Matlab simulink environment demonstrate the high precision of sliding mode controller compared with PI controller in the presence of uncertainties of joint flexibility.展开更多
Based on a linearized TCP/AQM model,a new proportional integral(PI)controller design approach is proposed.This analytical approach applies H_(∞) optimization and internal model control(IMC)theory to design active que...Based on a linearized TCP/AQM model,a new proportional integral(PI)controller design approach is proposed.This analytical approach applies H_(∞) optimization and internal model control(IMC)theory to design active queue management(AQM)routers that support transmission control protocol(TCP)flows.The most important feature of the proposed scheme lies in that it can be explicitly tuned with a single parameter for the trade-off between performance and stability of the AQM control system.It is thus flexible and easy to use in design.The proposed method and the designed PI controller are verified and compared with other existing AQM schemes using ns-2 simulator.The results show the advantages of the new PI controller design approach for AQM routers supporting TCP flows.展开更多
Multilevel inverters are gaining popularity in high power applications. This paper proposes a new ladder type structure of cascaded three-phase multilevel inverter with reduced number of power semiconductor devices wh...Multilevel inverters are gaining popularity in high power applications. This paper proposes a new ladder type structure of cascaded three-phase multilevel inverter with reduced number of power semiconductor devices which is used to drive the induction motor. The ultimate aim of the paper is to produce multiple output levels with minimum number of semiconductor devices. This paper uses only 11 switches along with 3 diodes and 4 asymmetrical sources to produce an output voltage of 21 levels. The modulation technique plays a major role in commutation of the switches. Here we implement the multicarrier level shifting pulse width modulation technique to produce the commutation signals for the inverter. The proposed multilevel inverter is used to drive the three-phase induction motor. The mathematical modeling of three-phase induction motor is done using Simulink. Furthermore the PI and fuzzy logic controllers are also used to produce the reference waveform of the level shifting technique which in turn produces the commutation signals of the proposed multilevel converter. The controllers are used to control the speed of the induction motor. The effectiveness of the proposed system is proved with the help of simulation. The simulation is performed in MATLAB/Simulink. From the simulation results, it shows that the proposed multilevel inverter works properly to generate the multilevel output waveform with minimum number of semiconductor devices. The PI and fuzzy logic controller performances are evaluated using the results which indicate that with the help of controllers the harmonics has been reduced and the speed control of induction motor is achieved under different loading conditions.展开更多
In this study, we investigate the performance of a boost converter regulating its output voltage using two control methods: Proportional-Integral (PI) control and neural control. Both methods are implemented on a simu...In this study, we investigate the performance of a boost converter regulating its output voltage using two control methods: Proportional-Integral (PI) control and neural control. Both methods are implemented on a simulation platform (Matlab/Simulink) and evaluated in terms of accuracy, response speed, and robustness to disturbances. Indeed, the output voltage of converters exhibits imperfections that require a control method to optimize efficiency when applying a variable load. Results show that neural control offers superior performance in terms of accuracy and response time, with faster and more precise regulation of the output voltage. On the other hand, PI control proves to be more robust against disturbances. These findings can help guide the selection of the appropriate control method for a boost converter based on the specific requirements of each application.展开更多
This paper presents the design of a controller for the measurement and reduction of conducted Electro Magnetic Interference (EMI) caused in the power electronic circuits. The conducted EMI is also separating the Commo...This paper presents the design of a controller for the measurement and reduction of conducted Electro Magnetic Interference (EMI) caused in the power electronic circuits. The conducted EMI is also separating the Common Mode (CM) and Differential Mode (DM) simultaneously using Line Impedance Stabilization Network (LISN). EMI is mitigated by the fuzzy controller. By comparing common mode voltage with the standard reference value, the generated error can be minimized by using fuzzy controller. Fuzzy controller is varying the PWM signal of the power electronic switching devices for reducing the electromagnetic interference. In this paper, comparison of PI and fuzzy controller of the open loop and closed loop models are implemented using MATLAB<sup>®</sup></sup> SIMULINK for measurement and reduction of the EMI level;and also simulation results of the PI controller and fuzzy controller analysis are presented in this paper. The fuzzy controller is provided to achieve the EMI level of the inverter within the standard limit.展开更多
In this paper, the modified LCC type of series-parallel Resonant Converter (RC) was designed and state-space modeling analysis was implemented. In this proposed converter, one leg of full bridge diode rectifier is rep...In this paper, the modified LCC type of series-parallel Resonant Converter (RC) was designed and state-space modeling analysis was implemented. In this proposed converter, one leg of full bridge diode rectifier is replaced with Synchronous Rectifier (SR) switches. The proposed LCC converter is controlled using frequency modulation in the nominal state. During hold-up time, the SRswitches control is changed from in-phase to phase-shifted gate signal to obtain high DC voltage conversion ratio. Furthermore, the closed loop PI and fuzzy provide control on the output side without decreasing the switching frequency. The parameter such as conduction loss on primary and secondary side, switching loss, core and copper also reduced. Simultaneously, the efficiency is increased about 94.79 is realized by this scheme. The proposed converter with an input of 40 V is built to produce an output of 235 V with the help of ZVS boost converter [1] even under line and load disturbances. As a comparison, the closed loop fuzzy controller performance is feasible and less sensitive than PI controller.展开更多
The Legendre orthogonal functions are employed to design the family of PID controllers for a variety of plants. In the proposed method, the PID controller and the plant model are represented with their corresponding L...The Legendre orthogonal functions are employed to design the family of PID controllers for a variety of plants. In the proposed method, the PID controller and the plant model are represented with their corresponding Legendre series. Matching the first three terms of the Legendre series of the loop gain with the desired one gives the PID controller parameters. The closed loop system stability conditions in terms of the Legendre basis function pole(λ) for a wide range of systems including the first order, second order, double integrator, first order plus dead time, and first order unstable plants are obtained. For first order and double integrator plants, the closed loop system stability is preserved for all values of λ and for the other plants, an appropriate range in terms of λ is obtained. The optimum value of λ to attain a minimum integral square error performance index in the presence of the control signal constraints is achieved. The numerical simulations demonstrate the benefits of the Legendre based PID controller.展开更多
An excessive use of non-linear devices in industry results in current harmonics that degrades the power quality with an unfavorable effect on power system performance.In this research,a novel control techniquebased Hy...An excessive use of non-linear devices in industry results in current harmonics that degrades the power quality with an unfavorable effect on power system performance.In this research,a novel control techniquebased Hybrid-Active Power-Filter(HAPF)is implemented for reactive power compensation and harmonic current component for balanced load by improving the Power-Factor(PF)and Total–Hormonic Distortion(THD)and the performance of a system.This work proposed a soft-computing technique based on Particle Swarm-Optimization(PSO)and Adaptive Fuzzy technique to avoid the phase delays caused by conventional control methods.Moreover,the control algorithms are implemented for an instantaneous reactive and active current(Id-Iq)and power theory(Pq0)in SIMULINK.To prevent the degradation effect of disturbances on the system’s performance,PS0-PI is applied in the inner loop which generate a required dc link-voltage.Additionally,a comparative analysis of both techniques has been presented to evaluate and validate the performance under balanced load conditions.The presented result concludes that the Adaptive Fuzzy PI controller performs better due to the non-linearity and robustness of the system.Therefore,the gains taken from a tuning of the PSO based PI controller optimized with Fuzzy Logic Controller(FLC)are optimal that will detect reactive power and harmonics much faster and accurately.The proposed hybrid technique minimizes distortion by selecting appropriate switching pulses for VSI(Voltage Source Inverter),and thus the simulation has been taken in SIMULINK/MATLAB.The proposed technique gives better tracking performance and robustness for reactive power compensation and harmonics mitigation.As a result of the comparison,it can be concluded that the PSO-basedAdaptive Fuzzy PI system produces accurate results with the lower THD and a power factor closer to unity than other techniques.展开更多
文摘Nowadays,researchers are becoming increasingly concerned about developing a highly efficient emission free transportation and energy generation system for addressing the pressing issue of environmental crisis in the form of pollution and climate change.The introduction of Electric Vehicles(EVs)solves the challenge of emission-free transportation while the necessity for decarbonized energy production is fulfilled by the installation and expansion of solar-powered Photovoltaic(PV)systems.Hence,this paper focuses on designing an effective PV based EV charging system that aids in stepping towards the achievement of a pollution free future.For overcoming the inherent intermittency associated with PV,a novel DC-DC converter is designed by integrating both Trans Z-source con-verter and Luo converter,which offers remarkable benefits of high conversion range,lesser voltage stress and excellent efficiency.A novel robust Lion Grey Wolf Optimized Proportional Integral(LGWO-PI)controller is designed for sig-nificantly strengthening the operation of the integrated converter in terms of peak overshoot,Total Harmonic Distortion(THD)and settling time.A 3’Voltage Source Inverter(VSI)is employed to convert the stable DC output from the PV sys-tem to AC,which is then used for driving the Brushless Direct Current Motor(BLDC)motor of EV.The speed of the BLDC is regulated using a PI controller.The BLDC motor gets the power supply from the grid during the unavailability of PV based power supply.The grid is integrated with the designed EV charging system through a 1’VSI and the process of grid voltage synchronization is carried out with the application of PI controller.The simulation for evaluating the operation of the presented EV charging system is done using MATLAB and the attained out-comes have validated that this introduced methodology delivers enhanced perfor-mance with optimal efficiency of 97.6%and lesser THD of 2.1%.
文摘The Brushless DC Motor drive systems are used widely with renewable energy resources.The power converter controlling technique increases the performance by novel techniques and algorithms.Conventional approaches are mostly focused on buck converter,Fuzzy logic control with various switching activity.In this proposed research work,the QPSO(Quantum Particle Swarm Optimization algorithm)is used on the switching state of converter from the generation unit of solar module.Through the duty cycle pulse from optimization function,the MOSFET(Metal-Oxide-Semiconductor Field-Effect Transistor)of the Boost converter gets switched when BLDC(Brushless Direct Current Motor)motor drive system requires power.Voltage Source three phase inverter and Boost converter is controlled by proportional-integral(PI)controller.Based on the BLDC drive,the load utilized from the solar generating module.Experimental results analyzed every module of the proposed grid system,which are solar generation utilizes the irradiance and temperature depends on this the Photovoltaics(PV)power is generated and the QPSO with Duty cycle switching state is determined.The Boost converter module is boost stage based on generation and load is obtained.Single Ended Primary Inductor Converter(SEPIC)and Zeta converter model is compared with the proposed logic;the proposed boost converter achieves the results.Three phase inverter control,PI,and BLDC motor drive results.Thus the proposed grid model is constructed to obtain the better performance results than most recent literatures.Overall design model is done by using MATLAB/Simulink 2020a.
文摘Multi-port converters are considered as exceeding earlier period decade owing to function in a combination of different energy sources in a single processing unit.Renewable energy sources are playing a significant role in the modern energy system with rapid development.In renewable sources like fuel combustion and solar energy,the generated voltages change due to their environmental changes.To develop energy resources,electric power generation involved huge awareness.The power and output voltages are plays important role in our work but it not considered in the existing system.For considering the power and voltage,Gaussian PI Controller-Maxpooling Deep Convolutional Neural Network Classifier(GPIC-MDCNNC)Model is introduced for the grid-connected renewable energy system.The input information is collected from two input sources.After that,input layer transfer information to hidden layer 1 fuzzy PI is employed for controlling voltage in GPIC-MDCNNC Model.Hidden layer 1 is transferred to hidden layer 2.Gaussian activation is employed for determining the output voltage with help of the controller.At last,the output layer offers the last value in GPIC-MDCNNC Model.The designed method was confirmed using one and multiple sources by stable and unpredictable input voltages.GPIC-MDCNNC Model increases the performance of grid-connected renewable energy systems by enhanced voltage value compared with state-of-the-art works.The control technique using GPIC-MDCNNC Model increases the dynamics of hybrid energy systems connected to the grid.
基金partially supported by the Australian Research Council(DP160104994)
文摘This paper introduces an electrical drives control architecture combining a fractional-order controller and a setpoint pre-filter. The former is based on a fractional-order proportional-integral(PI) unit, with a non-integer order integral action, while the latter can be of integer or non-integer type. To satisfy robustness and dynamic performance specifications, the feedback controller is designed by a loop-shaping technique in the frequency domain. In particular, optimality of the feedback system is pursued to achieve input-output tracking. The setpoint pre-filter is designed by a dynamic inversion technique minimizing the difference between the ideal synthesized command signal(i.e., a smooth monotonic response) and the prefilter step response. Experimental tests validate the methodology and compare the performance of the proposed architecture with well-established control schemes that employ the classical PIbased symmetrical optimum method with a smoothing pre-filter.
文摘In orthopaedic surgeries, permanent magnet DC motors are used to drill the bone and fix the screws. The Motor drive employs an inner current and outer speed control loop with a conventional or modern controller. To enhance the performance of the drive, this paper proposes a Brain Emotional Logic Based Intelligent Controller based chopper drive. The proposed drive scheme has been simulated using Matlab/Simulink and physically realized for validation. A comparative analysis has been made between the conventional PI controller based drive and the proposed system in order to prove that the proposed scheme has an edge over the traditional PI controller scheme counterpart.
文摘Greenhouse system (GHS) is the worldwide fastest growing phenomenon in agricultural sector. Greenhouse models are essential for improving control efficiencies. The Relative Gain Analysis (RGA) reveals that the GHS control is complex due to 1) high nonlinear interactions between the biological subsystem and the physical subsystem and 2) strong coupling between the process variables such as temperature and humidity. In this paper, a decoupled linear cooling model has been developed using a feedback-feed forward linearization technique. Further, based on the model developed Internal Model Control (IMC) based Proportional Integrator (PI) controller parameters are optimized using Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) to achieve minimum Integral Square Error (ISE). The closed loop control is carried out using the above control schemes for set-point change and disturbance rejection. Finally, closed loop servo and servo-regulatory responses of GHS are compared quantitatively as well as qualitatively. The results implicate that IMC based PI controller using PSO provides better performance than the IMC based PI controller using GA. Also, it is observed that the disturbance introduced in one loop will not affect the other loop due to feedback-feed forward linearization and decoupling. Such a control scheme used for GHS would result in better yield in production of crops such as tomato, lettuce and broccoli.
文摘This paper presents a comparative study of different decoupling control schemes for a two-input, two-output(TITO) binary distillation column via proportional-integral(PI)controller. The key idea behind this paper is designing two novel fuzzy decoupling schemes that depend on human knowledge,instead of the system mathematical model used in conventional decoupling schemes. Based on conventional and inverted decoupling schemes, fuzzy and inverted fuzzy decoupling schemes are developed. The control effect is compared using simulation results for the proposed two schemes with conventional decoupling and inverted decoupling. The proposed fuzzy decoupling schemes are easy to realize and simple to design, besides they have a good decoupling capability. Two methods are used to prove asymptotic stability of each loop and the entire closed-loop system by applying the proposed fuzzy decoupling-based PI controller.The Wood and Berry model of a binary distillation column is used to illustrate the applicability of the proposed schemes.
基金supported in part by the National Natural Science Foundation of China under Grant Nos.61773207,62173183the Natural Science Fund for Distinguished Young Scholars of Jiangsu Province under Grant No.BK20190020.
文摘The consensus problem for fractional multi-agent systems(MASs)with time delay is considered.The distributed fractional proportional-integral(PI)-type controller is designed so that the consensus of the proposed systems is achieved.Moreover,explicit condition to determine the crossing directions is developed.The results show that with the increase of time delay,the closed-loop system has two different dynamic characteristics:From consensus to nonconsensus and consensus switching.Furthermore,delay margin within which consensus of MASs will always hold is determined.The results should provide useful guidelines in the consensus analysis and in the analytical design of the distributed controllers.
基金This work is carried out without the support of any funding agency.
文摘Open communication system in modern power systems brings concern about information staleness which may cause power system frequency instability.The information staleness is often characterized by communication delay.However,communication delay is a packet-centered metric and cannot reflect the requirement of information freshness for load frequency control(LFC).This paper introduces the age of information(AoI),which is more compre-hensive and informative than the conventional communication delay modeling method.An LFC controller and com-munication are integrated into the design for LFC performance improvement.An AoI-aware LFC model is formulated first,and considering each allowable update period of the smart sensor,different AoI-aware PI controllers are then designed according to the exponential decay rate.The right AoI-aware controller and update period are selected according to the degree of frequency fluctuation of the power system.Case studies are carried out on one-area and two-area power systems.The results show the superior performance of the AoI-aware controllers in comparison to the delay-dependent controllers.
文摘Grid frequency variation causes phase angle deviation in current with respect to voltage.This is sensed at the phase-locked loop in the controller.In past studies the effect of grid frequency variation is neglected while designing the controller for power quality restoration.When modern grids are connected to large numbers of non-linear loads and various types of distributed generation(DG),it results in continuous variation in grid frequency.Thus it is necessary to consider the grid frequency variation for effective power quality restoration.However,tuning of conventional PI controller gains considering frequency variation is very difficult.Thus it is necessary to develop an adaptive intelligent nonlinear controller to tackle the effects of frequency variation,voltage distortion and non-linear load simultaneously.This paper presents the importance of considering the effects of the frequency variation,grid voltage distortion and non-linear load,while designing and deploying a controller for power quality restoration.The proposed controller supplies power to local load as well as transferring surplus power to the grid from DG along with the additional ben-efit of improving grid power quality.A DG with an ANFIS optimized PI current controller for power quality enhance-ment is proposed.The method is economical as it requires no additional hardware.Results are compared with PI,PI-RC and fuzzy current controllers to validate the effectiveness of the proposed controller.
文摘In practical applications of dynamic DNA nanotechnology,a biomolecular controller is required for maintaining the operation of the molecular actuator at a desired condition based on the information from molecular sensors.By making use of the DNA strand displacement mechanism as a"programming language"in the controller design,a biomolecular PI controller has been proposed.However,this PI control system has been verified only at the simulation level,and a theoretical regulation analysis is still required.Accordingly,in this study,we perform a rigorous regulation analysis of the biomolecular PI control system.Specifically,we theoretically prove that the output signal approaches the target level at a quasi-steady state.To this end,we apply the concept of finite-time regulation property to the biomolecular PI control system.
基金part funding for this work from the Clean Sky JTI – Systems for Green Operations ITDsupported by the National Natural Science Foundation of China (No. 50807002)+1 种基金the Aeronautical Science Foundation of China (No. 2008ZC51045)the Beijing Nova Program (No. 2008B13)
文摘This paper presents an auto-tuning method for a proportion plus integral(PI) controller for permanent magnet synchronous motor(PMSM) drives, which is supposed to be embedded in electro-mechanical actuator(EMA) control module in aircraft. The method, based on a relay feedback with variable delay time, explores different critical points of the system frequency response.The Nyquist points of the plant can then be derived from the delay time and filter time constant.The coefficients of the PI controller can then be obtained by calculation while shifting the Nyquist point to a specific position to obtain the required phase margin. The major advantage of the autotuning method is that it can provide a series of tuning results for different system bandwidths and damping ratios, corresponding to the specification for delay time and phase margin. Simulation and experimental results for the PMSM controller verify the performance of both the current loop and the speed loop auto-tuning.
文摘This paper is dealing with the problem of tracking control for uncertain flexible joint manipulator robots driven by brushless direct current motor(BDCM). Flexibility of joint in the manipulator constitutes one of the most important sources of uncertainties. In order to achieve high performance, all parts of the manipulator including actuator have been modeled. To cancel the tracking error, a hysteresis current controller and speed controllers have been developed. To evaluate the effectiveness of speed controllers, a comparative study between proportional integral(PI) and sliding mode controllers has been performed. Finally, simulation results carried out in the Matlab simulink environment demonstrate the high precision of sliding mode controller compared with PI controller in the presence of uncertainties of joint flexibility.
基金supported by the Specialized Research Fund for the Doctoral Program of Higher Education (No.20070248010)NCET (No.04-0383)Australia-China Special Fund for Scientific&Technological Cooperation (No.071107037).
文摘Based on a linearized TCP/AQM model,a new proportional integral(PI)controller design approach is proposed.This analytical approach applies H_(∞) optimization and internal model control(IMC)theory to design active queue management(AQM)routers that support transmission control protocol(TCP)flows.The most important feature of the proposed scheme lies in that it can be explicitly tuned with a single parameter for the trade-off between performance and stability of the AQM control system.It is thus flexible and easy to use in design.The proposed method and the designed PI controller are verified and compared with other existing AQM schemes using ns-2 simulator.The results show the advantages of the new PI controller design approach for AQM routers supporting TCP flows.
文摘Multilevel inverters are gaining popularity in high power applications. This paper proposes a new ladder type structure of cascaded three-phase multilevel inverter with reduced number of power semiconductor devices which is used to drive the induction motor. The ultimate aim of the paper is to produce multiple output levels with minimum number of semiconductor devices. This paper uses only 11 switches along with 3 diodes and 4 asymmetrical sources to produce an output voltage of 21 levels. The modulation technique plays a major role in commutation of the switches. Here we implement the multicarrier level shifting pulse width modulation technique to produce the commutation signals for the inverter. The proposed multilevel inverter is used to drive the three-phase induction motor. The mathematical modeling of three-phase induction motor is done using Simulink. Furthermore the PI and fuzzy logic controllers are also used to produce the reference waveform of the level shifting technique which in turn produces the commutation signals of the proposed multilevel converter. The controllers are used to control the speed of the induction motor. The effectiveness of the proposed system is proved with the help of simulation. The simulation is performed in MATLAB/Simulink. From the simulation results, it shows that the proposed multilevel inverter works properly to generate the multilevel output waveform with minimum number of semiconductor devices. The PI and fuzzy logic controller performances are evaluated using the results which indicate that with the help of controllers the harmonics has been reduced and the speed control of induction motor is achieved under different loading conditions.
文摘In this study, we investigate the performance of a boost converter regulating its output voltage using two control methods: Proportional-Integral (PI) control and neural control. Both methods are implemented on a simulation platform (Matlab/Simulink) and evaluated in terms of accuracy, response speed, and robustness to disturbances. Indeed, the output voltage of converters exhibits imperfections that require a control method to optimize efficiency when applying a variable load. Results show that neural control offers superior performance in terms of accuracy and response time, with faster and more precise regulation of the output voltage. On the other hand, PI control proves to be more robust against disturbances. These findings can help guide the selection of the appropriate control method for a boost converter based on the specific requirements of each application.
文摘This paper presents the design of a controller for the measurement and reduction of conducted Electro Magnetic Interference (EMI) caused in the power electronic circuits. The conducted EMI is also separating the Common Mode (CM) and Differential Mode (DM) simultaneously using Line Impedance Stabilization Network (LISN). EMI is mitigated by the fuzzy controller. By comparing common mode voltage with the standard reference value, the generated error can be minimized by using fuzzy controller. Fuzzy controller is varying the PWM signal of the power electronic switching devices for reducing the electromagnetic interference. In this paper, comparison of PI and fuzzy controller of the open loop and closed loop models are implemented using MATLAB<sup>®</sup></sup> SIMULINK for measurement and reduction of the EMI level;and also simulation results of the PI controller and fuzzy controller analysis are presented in this paper. The fuzzy controller is provided to achieve the EMI level of the inverter within the standard limit.
文摘In this paper, the modified LCC type of series-parallel Resonant Converter (RC) was designed and state-space modeling analysis was implemented. In this proposed converter, one leg of full bridge diode rectifier is replaced with Synchronous Rectifier (SR) switches. The proposed LCC converter is controlled using frequency modulation in the nominal state. During hold-up time, the SRswitches control is changed from in-phase to phase-shifted gate signal to obtain high DC voltage conversion ratio. Furthermore, the closed loop PI and fuzzy provide control on the output side without decreasing the switching frequency. The parameter such as conduction loss on primary and secondary side, switching loss, core and copper also reduced. Simultaneously, the efficiency is increased about 94.79 is realized by this scheme. The proposed converter with an input of 40 V is built to produce an output of 235 V with the help of ZVS boost converter [1] even under line and load disturbances. As a comparison, the closed loop fuzzy controller performance is feasible and less sensitive than PI controller.
文摘The Legendre orthogonal functions are employed to design the family of PID controllers for a variety of plants. In the proposed method, the PID controller and the plant model are represented with their corresponding Legendre series. Matching the first three terms of the Legendre series of the loop gain with the desired one gives the PID controller parameters. The closed loop system stability conditions in terms of the Legendre basis function pole(λ) for a wide range of systems including the first order, second order, double integrator, first order plus dead time, and first order unstable plants are obtained. For first order and double integrator plants, the closed loop system stability is preserved for all values of λ and for the other plants, an appropriate range in terms of λ is obtained. The optimum value of λ to attain a minimum integral square error performance index in the presence of the control signal constraints is achieved. The numerical simulations demonstrate the benefits of the Legendre based PID controller.
基金This work was supported by the King Saud University,Riyadh,Saudi Arabia,through Researchers Supporting Project number RSP-2021/184.
文摘An excessive use of non-linear devices in industry results in current harmonics that degrades the power quality with an unfavorable effect on power system performance.In this research,a novel control techniquebased Hybrid-Active Power-Filter(HAPF)is implemented for reactive power compensation and harmonic current component for balanced load by improving the Power-Factor(PF)and Total–Hormonic Distortion(THD)and the performance of a system.This work proposed a soft-computing technique based on Particle Swarm-Optimization(PSO)and Adaptive Fuzzy technique to avoid the phase delays caused by conventional control methods.Moreover,the control algorithms are implemented for an instantaneous reactive and active current(Id-Iq)and power theory(Pq0)in SIMULINK.To prevent the degradation effect of disturbances on the system’s performance,PS0-PI is applied in the inner loop which generate a required dc link-voltage.Additionally,a comparative analysis of both techniques has been presented to evaluate and validate the performance under balanced load conditions.The presented result concludes that the Adaptive Fuzzy PI controller performs better due to the non-linearity and robustness of the system.Therefore,the gains taken from a tuning of the PSO based PI controller optimized with Fuzzy Logic Controller(FLC)are optimal that will detect reactive power and harmonics much faster and accurately.The proposed hybrid technique minimizes distortion by selecting appropriate switching pulses for VSI(Voltage Source Inverter),and thus the simulation has been taken in SIMULINK/MATLAB.The proposed technique gives better tracking performance and robustness for reactive power compensation and harmonics mitigation.As a result of the comparison,it can be concluded that the PSO-basedAdaptive Fuzzy PI system produces accurate results with the lower THD and a power factor closer to unity than other techniques.