The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the ...The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design.展开更多
Current research on pilot-operated relief valve stability is primarily conducted from the perspective of system dynamics or stability criteria,and most of the existing conclusions focus on the spool shape,damping hole...Current research on pilot-operated relief valve stability is primarily conducted from the perspective of system dynamics or stability criteria,and most of the existing conclusions focus on the spool shape,damping hole size,and pulsation frequency of the pump.However,the essential factors pertaining to the unstable vibration of relief valves remain ambiguous.In this study,the dynamic behavior of a pilot-operated relief valve is investigated using the frequency-domain method.The result suggests that the dynamic pressure feedback orifice is vital to the dynamic characteristics of the valve.A large orifice has a low flow resistance.In this case,the fluid in the main spring chamber flows freely,which is not conducive to the stability of the relief valve.However,a small orifice may create significant flow resistance,thus restricting fluid flow.In this case,the oil inside the main valve spring chamber is equivalent to a high-stiffness liquid spring.The main mass-spring vibration system has a natural frequency that differs significantly from the operating frequency of the relief valve,which is conducive to the stability of the relief valve.Good agreement is obtained between the theoretical analysis and experiments.The results indicate that designing a dynamic pressure feedback orifice of an appropriate size is beneficial to improving the stability of hydraulic pilot-operated relief valves.In addition,the dynamic pressure feedback orifice reduces the response speed of the relief valve.This study comprehensively considers the stability,rapidity,and immunity of relief valves and expands current investigations into the dynamic characteristics of relief valves from the perspective of classical control theory,thus revealing the importance of different parameters.展开更多
The possibility of pressure control with the structural change of a safety valve is investigated Safety valve is commonly used as safety devices for numerous applications which include boilers,ships,industrial plant...The possibility of pressure control with the structural change of a safety valve is investigated Safety valve is commonly used as safety devices for numerous applications which include boilers,ships,industrial plants,and piping Setting and stopping pressures of a safety valve, p set and p sto ,are traditionally adjusted with a fine tuning of seat ring and valve ring heights, h sr and h vr However, it is not easy to achieve the proper setting and stopping pressures of a safety valve in practice The depth of inside and outside grooves in a valve, d i and d o are modified and their effects on setting and stopping pressures of a safety vlave are tested The most appropriate values appear 1 0 mm in d i and 0 5~1 0 mm in d o,respectively The valve ring height, h vr ,shows that the best results can be achieved at 2 3 mm for setting pressures of 0 1~0 4 MPa and 1 0 mm for setting pressures of 0 5~1 0 MPa The stopping pressures increases with the increase of seat ring height, h sr , upto certain h sr value and then becomes independent to the seat ring height This implies that there exists the optimum h sr ,which provides the largest flow rate and the proper stopping pressure Stopping pressures of a safety valve are adjusted with the seat ring and valve ring heights This study,however,demonstrated that the modification of value grooves also changes setting and stopping pressures of a safety valve Therefore,the proper selection in dimensions of the inside and outside grooves should be considered for the safety valve design展开更多
In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The...In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve.展开更多
BACKGROUND Lack of mobilization and prolonged stay in the intensive care unit(ICU)are major factors resulting in the development of ICU-acquired muscle weakness(ICUAW).ICUAW is a type of skeletal muscle dysfunction an...BACKGROUND Lack of mobilization and prolonged stay in the intensive care unit(ICU)are major factors resulting in the development of ICU-acquired muscle weakness(ICUAW).ICUAW is a type of skeletal muscle dysfunction and a common complication of patients after cardiac surgery,and may be a risk factor for prolonged duration of mechanical ventilation,associated with a higher risk of readmission and higher mortality.Early mobilization in the ICU after cardiac surgery has been found to be low with a significant trend to increase over ICU stay and is also associated with a reduced duration of mechanical ventilation and ICU length of stay.Neuromuscular electrical stimulation(NMES)is an alternative modality of exercise in patients with muscle weakness.A major advantage of NMES is that it can be applied even in sedated patients in the ICU,a fact that might enhance early mobilization in these patients.AIM To evaluate safety,feasibility and effectiveness of NMES on functional capacity and muscle strength in patients before and after cardiac surgery.METHODS We performed a search on Pubmed,Physiotherapy Evidence Database(PEDro),Embase and CINAHL databases,selecting papers published between December 2012 and April 2023 and identified published randomized controlled trials(RCTs)that included implementation of NMES in patients before after cardiac surgery.RCTs were assessed for methodological rigor and risk of bias via the PEDro.The primary outcomes were safety and functional capacity and the secondary outcomes were muscle strength and function.RESULTS Ten studies were included in our systematic review,resulting in 703 participants.Almost half of them performed NMES and the other half were included in the control group,treated with usual care.Nine studies investigated patients after cardiac surgery and 1 study before cardiac surgery.Functional capacity was assessed in 8 studies via 6MWT or other indices,and improved only in 1 study before and in 1 after cardiac surgery.Nine studies explored the effects of NMES on muscle strength and function and,most of them,found increase of muscle strength and improvement in muscle function after NMES.NMES was safe in all studies without any significant complication.CONCLUSION NMES is safe,feasible and has beneficial effects on muscle strength and function in patients after cardiac surgery,but has no significant effect on functional capacity.展开更多
基金supported by the National Key R&D Program of China(No.2021YFB2402001)the Postgraduate Innovation and Entrepreneurship Practice Project of Anhui Province(No.2022cxcysj013)+2 种基金the China Postdoctoral Science Foundation(No.2022T150615)the Fundamental Research Funds for the Central Universities(No.WK5290000002)supported by Youth Innovation Promotion Association CAS(No.Y201768)。
文摘The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design.
基金Supported by National Natural Science Foundation of China(Grant No.52175059)National Key Research and Development Program of China(Grant No.2018YFB2001100).
文摘Current research on pilot-operated relief valve stability is primarily conducted from the perspective of system dynamics or stability criteria,and most of the existing conclusions focus on the spool shape,damping hole size,and pulsation frequency of the pump.However,the essential factors pertaining to the unstable vibration of relief valves remain ambiguous.In this study,the dynamic behavior of a pilot-operated relief valve is investigated using the frequency-domain method.The result suggests that the dynamic pressure feedback orifice is vital to the dynamic characteristics of the valve.A large orifice has a low flow resistance.In this case,the fluid in the main spring chamber flows freely,which is not conducive to the stability of the relief valve.However,a small orifice may create significant flow resistance,thus restricting fluid flow.In this case,the oil inside the main valve spring chamber is equivalent to a high-stiffness liquid spring.The main mass-spring vibration system has a natural frequency that differs significantly from the operating frequency of the relief valve,which is conducive to the stability of the relief valve.Good agreement is obtained between the theoretical analysis and experiments.The results indicate that designing a dynamic pressure feedback orifice of an appropriate size is beneficial to improving the stability of hydraulic pilot-operated relief valves.In addition,the dynamic pressure feedback orifice reduces the response speed of the relief valve.This study comprehensively considers the stability,rapidity,and immunity of relief valves and expands current investigations into the dynamic characteristics of relief valves from the perspective of classical control theory,thus revealing the importance of different parameters.
文摘The possibility of pressure control with the structural change of a safety valve is investigated Safety valve is commonly used as safety devices for numerous applications which include boilers,ships,industrial plants,and piping Setting and stopping pressures of a safety valve, p set and p sto ,are traditionally adjusted with a fine tuning of seat ring and valve ring heights, h sr and h vr However, it is not easy to achieve the proper setting and stopping pressures of a safety valve in practice The depth of inside and outside grooves in a valve, d i and d o are modified and their effects on setting and stopping pressures of a safety vlave are tested The most appropriate values appear 1 0 mm in d i and 0 5~1 0 mm in d o,respectively The valve ring height, h vr ,shows that the best results can be achieved at 2 3 mm for setting pressures of 0 1~0 4 MPa and 1 0 mm for setting pressures of 0 5~1 0 MPa The stopping pressures increases with the increase of seat ring height, h sr , upto certain h sr value and then becomes independent to the seat ring height This implies that there exists the optimum h sr ,which provides the largest flow rate and the proper stopping pressure Stopping pressures of a safety valve are adjusted with the seat ring and valve ring heights This study,however,demonstrated that the modification of value grooves also changes setting and stopping pressures of a safety valve Therefore,the proper selection in dimensions of the inside and outside grooves should be considered for the safety valve design
基金Supported by China Coal Research Institute Innovation Item(2007CX06)
文摘In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve.
文摘BACKGROUND Lack of mobilization and prolonged stay in the intensive care unit(ICU)are major factors resulting in the development of ICU-acquired muscle weakness(ICUAW).ICUAW is a type of skeletal muscle dysfunction and a common complication of patients after cardiac surgery,and may be a risk factor for prolonged duration of mechanical ventilation,associated with a higher risk of readmission and higher mortality.Early mobilization in the ICU after cardiac surgery has been found to be low with a significant trend to increase over ICU stay and is also associated with a reduced duration of mechanical ventilation and ICU length of stay.Neuromuscular electrical stimulation(NMES)is an alternative modality of exercise in patients with muscle weakness.A major advantage of NMES is that it can be applied even in sedated patients in the ICU,a fact that might enhance early mobilization in these patients.AIM To evaluate safety,feasibility and effectiveness of NMES on functional capacity and muscle strength in patients before and after cardiac surgery.METHODS We performed a search on Pubmed,Physiotherapy Evidence Database(PEDro),Embase and CINAHL databases,selecting papers published between December 2012 and April 2023 and identified published randomized controlled trials(RCTs)that included implementation of NMES in patients before after cardiac surgery.RCTs were assessed for methodological rigor and risk of bias via the PEDro.The primary outcomes were safety and functional capacity and the secondary outcomes were muscle strength and function.RESULTS Ten studies were included in our systematic review,resulting in 703 participants.Almost half of them performed NMES and the other half were included in the control group,treated with usual care.Nine studies investigated patients after cardiac surgery and 1 study before cardiac surgery.Functional capacity was assessed in 8 studies via 6MWT or other indices,and improved only in 1 study before and in 1 after cardiac surgery.Nine studies explored the effects of NMES on muscle strength and function and,most of them,found increase of muscle strength and improvement in muscle function after NMES.NMES was safe in all studies without any significant complication.CONCLUSION NMES is safe,feasible and has beneficial effects on muscle strength and function in patients after cardiac surgery,but has no significant effect on functional capacity.